Water Resources Development Directorate Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Water Resources Development Directorate - WRDD Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date29 Feb 2024
Closing Date21 Mar 2024
Tender Amount₹ 23,11,921 
Notes
Download

Costs

Summary

Installation Of Gajalpur Mini Solar Rli Scheme In Suri-i Block

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
110 mm. dia P.V.C. pipe class-II ( with a loose matching coupler,class-II) marking IS No. 4985/ 2000 with latest amending with free solvent cement.

12

3408

284

... More
Coupler(Cl-II) for 140 mm. dia P.V.C. pipe ( extra) I.S. 10124/2009, Part- II with free solvent cement.

11

1430

130

... More
Coupler(Cl-II) for 110 mm. dia P.V.C. pipe ( extra) I.S. 10124/2009, Part- II with free solvent cement.

50

3350

67

... More
110x110x 110 mm. P.V.C. Tee (Part-V) with free solvent cement,I.S. 10124/2009 (Cl-II)

9

3123

347

... More
140x140x 140 mm. P.V.C. Tee (Part-V) with free solvent cement,I.S. 10124/2009 (Cl-II)

3

2136

712

... More
140 x 110 mm Reducer(cl-II) with free solvent cement,I.S. 10124/2009, Part-3.

4

1132

283

... More
140 mm. dia 900 bend (cl-II) ( IS. No. 10124/ 2009 Part- 8 with latest amendment ),with free solvent cement.

2

1294

647

... More
110 mm. dia 600 bend(cl-II) ( IS. No. 10124/ 2009 Part- 8 with latest amendment ) with free solvent cement.

6

2268

378

... More
110 mm. dia 900 bend(cl-II) ( IS. No. 10124/ 2009 Part- 8 with latest amendment ) with free solvent cement.

13

4914

378

... More
140 mm. dia IS. NO. 10124/ 2009 Part- 4 with latest amendment End cap (Cl-III) with free solvent cement.

1

330

330

... More
110 mm.dia IS.NO.10124/2009 Part-4 with latest amendment.PVC End Cap.(Cl-III) with free solvent cement.

2

460

230

... More
110 mm. dia ( IS. No 10124/2009 Part- 6 with latest amendment) F.T.P.(Cl-II) with free solvent cement.

9

2790

310

... More
140 mm. dia ( IS. No 10124/2009 Part- 6 with latest amendment) F.T.P.(Cl-II) with free solvent cement.

2

924

462

... More
100 mm dia. Flexible PVC Hose for Suction and Delivery line( IS. No 10124/2009)

60

46440

774

... More
Solvent cement extra (Medium duty)

3

1275

425

... More
G.I. Tripod set and Inlet & outlet Pipe Fittings(I No. for 2nd chamber of Drawing) as per drawing and Specification

1

202000

202000

... More
100 mm dia Galv. MS Flanged Pipe with flange as per IS 1239 (Part-I)/2004 & 6392/1971, table 17 Specification.

24

59376

2474

... More
150 mm. dia I.S.I. 14846/2000 Amd No. 1&2 mark and specification PN- 1.6 sluice valve .

2

19900

9950

... More
100 mm dia C.I. Sluice Valve I.S.I. 14846/2000 Amd No. 1&2 mark and specification PN- 1.6 sluice valve .

2

12600

6300

... More
Ф100 mm NTP /Alfa-Alfa Valve as per technical specification

9

29700

3300

... More
80X65mm M.S. flanged reducer

2

2762

1381

... More
100X80mm M.S. flanged reducer

4

6532

1633

... More
M.S Foundation Bolt for Pump Motor sets manufactured from 20 mm nominal diameter M.S Rod as per IS 2026/1992. Total length of bolts is 275+10 mm in length & 20 mm in nomonal diameter with Nuts & 2 nos washer,the average weight of such bolt 1.5 kg per bolt with tolerance in weight of each bolt @ +/-10%

8

1784

223

... More
Foundation Bolt, For Distrubution Chamber Quadruped (1.1 Kg each) manufactured from 20 mm nominal dia MS rod as per IS 2062/2002.Total length of the bolt is 375+_ 10mm having welded head 80+- 10 mm in length and 20 mm nominal dia with Nut & 2 Nos. Washer.

14

3122

223

... More
M.S. Hexagonal Head Bolts & Nuts conforming to IS-1363 (Part-I) 1992 product grade - C with latest ammedments for boths IS-1363 (Part-3) / 2002 of product grade C with latest amount for nuts properties / class for bolt 4.62 nuts for 4.5. ISI Marked.

-

-

-

... More
M-20 X 80 mm

50

8800

176

... More
M-20 X 100 mm

10

1760

176

... More
M-16 X 65 mm

40

7040

176

... More
M-16 X 80 mm

12

2112

176

... More
M-16 X 50 mm

18

3168

176

... More
Foot valve leather washer 100mm dia,

2

400

200

... More
Sal Sleeper (4ft X 6in X 4 in)

2

4400

2200

... More
4" Hose Clamp

9

1008

112

... More
Compresed Asbestos fibre jointing for Quadruped & Tripod set( for raised surface of Flange as per IS-6392)

-

-

-

... More
300mm.dia(Table-5)

2

2036

1018

... More
Rubber Insertion I.S. 638/1979 with latest amendment sheet 5 mm. 2 Ply. ( for raised surface of Flange as per IS-6392)

-

-

-

... More
150 m dia Ruber Insertion(Table-17)

25

4150

166

... More
150 m dia Ruber Insertion(Table-5)

12

1992

166

... More
100 m dia Ruber Insertion(Table-17)

21

2709

129

... More
80 m dia Ruber Insertion (Table-17)

11

1045

95

... More
3C X 4 sqmm copper cable conforming to IS 694 [Busbar to 32 A, TP Main switch and 32 A TP switch to Motor starter]

3

717

239

... More
2 X 3C X 2.5 sqmm copper cable conforming to IS 694 in 25 mm GI conduit (ISI-Medium quality)[ Star-Delta Motor starter to Motor]

10

3260

326

... More
Laying of Water Transmission Arrangement for Major RLI Scheme

-

-

-

... More
Earthwork in excavation of field trenches as per design section and alignment for laying of pipe lines(PVC,RCC,ACP etc) upto a depth of 1500 mm all sorts of soil including removing,spreading or stacking extra earth as directed.The item includes necessary trimming of sides trenches,levelling,dressing and ramming the bottom as required complete.

-

-

-

... More
For foundation Blocks of Quadrupped

3.4

336

99.01

... More
For spout Chambers

17

1683

99.01

... More
For Pipe Trenches etc.

1035

102475

99.01

... More
Earth work in filling in treches after laying pipelines (P.V.C, R.C.C, A.C.P etc) with good earth obtained from excavation of field trenches in layers not exceeding 225 mm, including watering and ramming etc layer by layer complete (Payment to be made on the basis of mesurement of finished quantity of work)

980

64689

66.01

... More
Laying of UPVC pipes of different diameters within field trenches in curve/ straight line including using UPVC fittings, Viz. Horizontal and Vertical Bends, riser pipes, Tee Reducer etc.and making leak proof joints with couplers after roghening the surface with wire brush and emery paper and applying solvent cement (The rate is inclusive of transport of pipes, fittigs and solvent cement to be supplied by deptt.) all complete asper direction of Engineer-In- charge.

-

-

-

... More
140 mm.OD.

252

2555

10.14

... More
110 mm. OD.

1200

10464

8.72

... More
Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand.

-

-

-

... More
For foundation Blocks of Quadrupped

3.5

931

266

... More
For spout Chamber

42

11172

266

... More
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm. as directed and consolidating same by thorough saturation with water ramming complete, including the cost of supply of sand. (Payment to be made on measurement of finished quantity)

-

-

-

... More
For foundation Blocks of Quadrupped

0.3

171

572.55

... More
For spout Chamber

5.7

3263

572.55

... More
Ordinary Cement Concrete (mix 1:1.5:3) with graded stone chips (20 mm. nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevent IS codes.Pakur Variety

-

-

-

... More
For foundation Blocks of tripod

0.52

2711

5213.91

... More
Ordinary Cement Concrete (mix 1:2:4) with graded stone chips (20 mm. normal size) excluding shuttering and reinforcement, if any, in ground floor. as per relevent IS Code. a) Pakur Variety

-

-

-

... More
For foundation Blocks of tripod

1.03

4784

4645.26

... More
For spout Chamber

4.45

20671

4645.26

... More
Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor). Above 30mm to 37 mm. thick wooden shuttering as per decision & direction of Engineer-in-charge.

-

-

-

... More
For foundation Blocks of tripod

5.2

1705

328

... More
For spout Chamber

12.75

4182

328

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor / upto 4m. (i) Tor steel/Mild steel(SAIL/TATA/RINL) i)For foundation Blocks of tripod

0.03

1765

55182.75

... More
Brick work in cement mortar (1 : 6) with first class kiln burnt bricks including racking out joints, scaffolding and other incidental works etc. complete in foundation and plinth. (a) In foundation & plinth

10

42430

4243

... More
125 mm. thick brickwork with 1st class bricks in cement mortar (1 : 4) in ground floor.

8.1

4795

592

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints, including throating, nosing and drip course, scaffolding/staging where necessary (ground floor) excluding cost of chipping over concrete surface.with (1:6) cement mortar, 15 mm. thick plaster

113

16837

149

... More
Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. NOTE : Cement 0.152 cu.m. per 100 sq.m.

113

3842

34

... More
Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.W. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of Engineer-in-Charge.150 mm. dia. ERW pipe.

-

-

-

... More
150 mm. dia. ERW pipe.

96

12944

134.84

... More
100 mm dia. NB ERW/MS Pipes

24

1980

82.51

... More
Erection, fitting, fixing of set of M S tripod inlet and outlet pipe fittings for MIDI RLI Scheme with 1st. And 2nd chamber.(Rate inclusive of transportation from departmental store to work site)

1

12466

12466.74

... More
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.

20

580

29

... More
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : With other than hi-gloss of approved quality- (iv) Two coats (with any shade except white)

20

1580

79

... More
Labour charges for fitting, fixing100 mm. Dia. Alfa-AIfa valve with 110 mm. dia. P.V.C. riser pipe with the help of flanged P.V.C. tail-piece by joining the P.V.C. End of Tail-piece and riser pipe with coupler and flanged end of Tail-piece and Alfa-Alfa valve with rubber insertion, nuts and bolts etc. complete.

9

975

108.44

... More
Labour charges for fitting, fixing (150 x 140) mm dia M S reducer with 140 mm dia UPVC pipe with the help of FTP (flanged tail piece) by joining the PVC end of the tail piece and 140 mm dia UPVC pipe with coupler and flanged end of tail piece and expander with rubber insertion, nuts and bolts etc. complete. (Rate inclusive of transportation from departmental store to work site).

2

216

108.44

... More
Labour charges for fitting, fixing 150 mm.& 100 mm Dia Sluice Valve with rubber insertion, nuts and bolts etc. complete.

4

218

54.69

... More
Supplying, fitting and fixing including transportation of sign board for identifing the exact location of Major RLI scheme (one at road side and other at site) the board will be made 3 mm thick MS plate of size 300 mm × 600 mm and fitted and fixed on 50 mm GI Pipe of IS 1239/90 (part-1) including cutting, welding and writting of both sides of Sign board. Base - Yellow, and ward Red. Both bottom end of the stands pipe will be grouted in 1:2:4 CC on a single brick flat soiling. This will include one materials and labour complete as per drawing and direction of EIC.

1

3677

3677.51

... More
Suppling 1 mtr x 0.6 m x 24 swg MS board contaning list of spout wise water users by making numbers of spout as directed by EIC. The board should have base colour - Black and words - White to be fitted and fixed on the wall of the pump house.

1

942

942.95

... More
Installation of Electro-Motor Pumping set of any make / brand and for RLI scheme on pump foundation over SAL sleeper by fixing nuts and bolts and making connection of suction hose and foot valve with necessary fittings at the inlet end of the water pump and fitting fixing of 90° M S priming bend, sluice valve and delivery hose with all necessary fittings at the delivery end of the water pump, duly connected with the pipe line, maintaining proper alignment and level including cutting holes on the wall of the pump house where necessary, mending good damages after completion of the works as per direction of Engineer-in-charge. . b) For Major R.L.I. Scheme.

2

1446

723.24

... More
Testing of pipe line system against leakages by filling the distribution chamber with water and supplying water through the entirepipe line net work for at least 4 (four) hour by running the departmental Deasel Engine pumping set, including supplying necessary fuels & lubricants and hiring and transporting tools and plants all complete as per direction of Engineer-in-Charge.

1

2494

2494.1

... More
Installation of Sloar Module and Accessories

-

-

-

... More
Solar Module: Supply , transport , installation and commissioning of ISI marked as per IS 14286 and IEC 61853(1), 61730(1&2), 61710 certified Solar Module of Multicrystaline/Monocrystalline/ Monocrystalline PERC/bifacial cell with min. efficiency of 15% and fill factor more than 70%, laminated between sheet of -Ethylene Vinyl Acetate (EVA) and high transmissivity 3.2/4.0 mm tempered glass , framed in anodized aluminium frame .The power output of individual PV modules used in the PV array, under STC, should be a minimum of 300 Watt peak, with adequate provision for measurement tolerances.Modules supplied with the SPV system should have warranty for output wattage, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Necessary test certificate also to be supplied.

-

-

-

... More
a) For 5 HP Off-grid Solar Water Pumping System with Polycrystalline SPV modules -5350-5700 Wp.(2X 16 nos@340Wp)

10880

322700

29.66

... More
Module Mounting Structure ( For 2HP, 3HP and 5HP Solar Water Pumping System): Supply , transportation & installation of G.I manual tracking structure made of MS hollow sections, pipes, plates, angles etc as per IS 1161/1239, 1079/2062, to hold min 300 Wp SPV Module as per drawing and specification of MNRE . The steel structure is to be protected with minimum 80 micron galvanisation(hot dip) and provided with dual axis manual tracking arrangement three times in a day and seasonal tilting are to be regulated to face the sun optimally. [The weight of the Module Mounting Structure holding 4 Modules should not be less than 195Kgs, holding 6 Modules should not be less than 210 Kg and holding 8 Modules should not be less than 245 Kg. (250Kg for 6 module structure]

1060

153700

145

... More
Foundation of Module Mounting Structure: Suitable and stable Reinforced Cement Concrete foundation for dual axis manual tracking SPV Module structure as per approved drawing.

-

-

-

... More
For 8 module structure

4

50787

12696.96

... More
Power conditioning unit with IP54 enclosure : Supply , transport , installation and commissioning of IP 54 protected enclosured Inverter Unit qualifying IEC 61683-Efficiency measurement and IEC 60068-2-Environment Standard , safety standard suitable for 3 Phase A.C. motor, IGBT based high voltage switching inverter with MPPT technology, to take care of the variation of Sun light and will be suitably mounted inside the metal enclosure. Inverter should have protection against Dry run, Over current, Under current, Over voltage, Under voltage, Short circuit etc. System should be able to run at low sunshine and minimum 7 to 8 hours a day run should be possible during normal sunshine.condition. Inverter should have option to auto start for any short trip off due to low light/ cloudy situation except for dry run. Inverter should be provided with a display to show the various parameter by the user such as Voltage, Current, Solar panel DC voltage, Inverter IGBT temperature, Out put AC voltage, Output frequency, Pump flow (direct or calculated method), Irradiation etc . The system should store the data at a set interval, be capable to transfer it to external storage device and support communication of its operational parameters and logs over Modbus protocol . It should also monitor and save total run time, total water pumped etc . There should be provision for interfacing GPRS based data transmission.

-

-

-

... More
For 5 HP capacity Pump-motor set

2

113764

56882

... More
Cable and Accessories : Supplying, fitting and fixings of UV rated Copper Cable laid inside HDPE conduit and other accessories as per followings with necessary connection with the Solar PV Module, MPPT etc. i. 4.0 Sq mm single core multi studs - 5m(for 2HP) & 20m(for 3/5 HP) ii. Lugs, HDPE Pipe, Flexible Pipe, Saddle, Cable tie etc

-

-

-

... More
for 2 or more Structure per Structure with 9 m distance between structures.

4

13736

3434

... More
Earthing: Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe including excavation of soil for installation of Earth Electrode and filling & ramming and connecting to individual structure to earth electrode including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.

4

10644

2661

... More
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of 8 swg on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.

80

1040

13

... More
a) Lighting System at Scheme: (with lighting Pole) : Dusk to dawn lighting arrangement of at 4 mts height above ground level, with Hot dip galvanised 80 mm x 50 mm , medium duty pipe, with 12 V, 15Ah 2-in-1 Lithium ion/ Ferro- Phosphate battery with in-built 7-11watt LED lamp , 50 Wp solar panel to cover the scheme area. The lighting system should be warranted for 5years from the date of installation.

1

19030

19030

... More
Lightning protection (Pole mounted): Lightning protection with 3" X 1.5" G.I pipe of 5m + 1 m height with base flange in proper RCC foundation and S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. Earthing with 65 mm dia GI pipe (Medium) 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. including connection to earth electrodes with 25 X 6mm G.I strip. (Provision of one lightning protection for each scheme as per drawing)

2

21366

10683

... More
Supply and installation of 3 phase electromotor pump-motor set suitable for Solar operation covering 5 years warranty for the following conditions including loading, unloading, transportation etc.:- c) 5 HP ISI marked 3 phase 415 V Pump-Motor set having discharge at required head as below:- i) Monoblock Surface Pump-motor set ISI marked as per IS: 9079 for mini RLI scheme with discharge of 13.8 Lps at 18 mts. total head with 100/80 mm dia. reinforced PVC suction pipe (20m) and delivery pipe(10mts), foot valve, nipple, priming bend Cable and all other required accessories to complete connection of suction and delivery side .

2

124812

62406

... More
Testing and commissioning of scheme after completion of all work

2

4000

2000

... More
Comprehensive maintenance charges for 4 years beyond 1 year warranty period (which cover monthly inspection, Yearly training to WUA, to attend breakdown within 3 days and to keep the scheme in operation without lapse of time) c) For 5 HP both for Submersible & Surface pump Note: Total comprehensive maintenance charge is to be withheld in addition to Securirty Deposit . Security Deposit will be released after expiry of warranty period of 1 year & Comprehensive maintenance charges will be released @ Rs.0.75 per Wp per year at the end of each maintenance period i.e.at the end of 2nd year, 3rd year, 4th year, 5th year. In case the “Bidder” does not provide service during the warranty & comprehensive maintenance period, the amount so held up will be forfeited

10880

32640

3

... More
Insurance @ 2% for Item No. 3.01,3.04,3.08, and 3.10 for a period of 5 years. Note:2 Ist year's Insurance charge is to be paid on production of Original Receipt of premium payment. Remaining 4 years Insurance payment is to be withheld which will be released during 2nd, 3rd , 4th & 5th year on production of Original Receipt of premium payment.

0.02

11606

580306.8

... More
Supplying, fitting and fixing including transportation of sign board for identifing the exact location of MINI RLI scheme (one at road side and other at site) the board will be made 3 mm thick MS plate of size 300 mm × 600 mm and fitted and fixed on 50 mm GI Pipe of IS 1239/90 (part-1) including cutting, welding and writting of both sides of Sign board. Base - Yellow, and ward Red. Both bottom end of the stands pipe will be grouted in 1:2:4 CC on a single brick flat soiling. This will include one materials and labour complete as per drawing and direction of EIC.

1

3677

3677.51

... More
Supply fitting and fixing of Hot dip Galvanised ( min 80 micron) / Powder Coat painted M.S Kiosk Box / Stainless Steel Kiosk of SS304 of 710(L) X 410(W) X 740(H) and total height with legs is 1670mm for mounting of motor-pump set including transportation, grouting in Cement Concrete.

2

28314

14157

... More
Remote monitoring for 5 years: Provision for remote monitoring for the pumps must be made in the pump controller through an integral arrangement having following basic functions: a. Controller must be assigned with a unique serial number and its live status must be observed remotely on online portal through login credentials. b. Live status must indicate whether controller is ON/OFF.The parameters i.e. the water output ,water flow rate , in fault condition,array input voltage/current,power and motor frequency should at logged at an interval of 10 minutes. c. Controller must have a back up to store the data locally(at least for 1 year)supply & installation of GSM/GPRS based Data Transmitter or Modem and to provide remote monitoring service to transmit the parameters to the central server from the solar pumping system with time stamp at user defined interval and report generation at the buyer end.(Refer Technical Specification)

2

43700

21850

... More
Carriage of 96 mtr 150 mm dia galv. ms flanged gi pipe with flange from store under kolkata(A-M) resources Division in burdwan to Suri (A-M) sub-division store (considering distance approximately equal to 110 km)

1

3244

3244.84

... More
Add Extra Carriage @4% from Item No.2.03 to 2.24

0.04

6872

171806.76

... More
Add GST @ 18 % on PWD and WRDD Items from Item No. 2.01 to 4.00

0.18

235192

1306627.11

... More
Add Cess @1% from Item No.2.01 to 5.00

0.01

15418

1541819.99



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.