Water Resources Development Directorate Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Water Resources Development Directorate - WRDD Tender
Civil And Construction
Excavation
Eprocure
Opening Date15 Mar 2024
Closing Date1 Apr 2024
Tender Amount₹ 55,96,871
Costs
EMD
₹ 1,11,937Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WRDD_686105_4Bid Award Id
ViewTender No
WRIDD/EEAI/BST/eNIT21/23-24Tender Authority
Water Resources Development Directorate ViewPurchaser Address
-Website
http://http://www.wbwridd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
ii) 150 mm dia UPVC Housing Pipe
252
25842
102.55
a) Supplying and filling up of the annular space between the Well Pipe and the bore hole by coarse sand including watering as necessary as per direction of Engineer-in-Charge.
32.03
23014
718.53
Supplying, fitting and fixing including supplying of suitable jointing compound for fixing in position, threading, if necessary etc. all complete. a) 100 mm dia CI/Steel cutter piece upto 450 mm long with socket.
7
2310
330.03
(b) 150 mm dia G.I. threaded top cap fixed in position.
7
3960
565.77
(c) 100 mm. X 150 mm. UPVC reducing socket.
7
3300
471.48
Supply of PVC pipes & fittings (medium duty) conforming to ASTMD -
1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (i) Nipple (300 mm long)
100 mm dia
7
2745
392.27
(ii) 150 mm dia
7
3333
476.19
Supplying, fitting & fixing of 150 mm dia ISI marked G.I. Short pipe (medium quality) of suitable length (0.60m to 1.0m) with both end screwed, one end to match with the 150 mm dia PVC Housing Pipe and other end match with the 150 mm dia MS top cap as per direction of the E.I.C.
7
10013
1430.46
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.
a) Pakur Variety
1.51
8658
5726.58
Washing and development by pumping with 30 cum per hour capacity pump for a period till sand free water comes out and the discharge is about 30 cum per hour, followed by final yield test; inclusive of all tools, plants and scaffolding and hire charge of submersible pump, generator etc. all complete
7
31947
4563.88
Charges for Mobilisation of drilling equipments, tools and plants etc. and transportation of departmental materials from Sub-divisional store to work site and returning excess departmental materials if any, to Sub-divisional store after completion of work.
7
12673
1810.46
Making arrangement and showing varticality test and sounding test including cost / hire charges of necessary tools and plants, scaffolding, labour etc. all complete as per direction of Engineer-in-Charge.
7
6006
858.08
Part- B : Solar Pumping System Solar Module: Supply , transport , installation and commissioning of ISI marked as per IS 14286 and IEC 61853(1), 61730(1&2), 61710 certified Solar Module of Multicrystaline/Monocrystalline/ Monocrystalline PERC/bifacial cell with min. efficiency of 15% and fill factor more than 70%, laminated between sheet of -Ethylene Vinyl Acetate (EVA) and high transmissivity 3.2/4.0 mm tempered glass , framed in anodized aluminium frame .The power output of individual PV modules used in the PV array, under STC, should be a minimum of 300 Watt peak, with adequate provision for measurement tolerances.Modules supplied with the SPV system should have warranty for output wattage, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Necessary test certificate also to be supplied. i)For 5 HP Off-grid Solar Water Pumping System with Polycrystalline SPV modules - 5350 - 5700 Wp. (16nos. @340Wp)
38080
1129452
29.66
Module Mounting Structure ( For1 HP, 2HP, 3HP, 5HP and 10 HP Solar Water Pumping System):Supply , transportation & installation of G.I manual tracking structure made of MS hollow sections, pipes, plates, angles etc as per IS 1161/1239, 1079/2062, to hold min 300 Wp SPV Module as per drawing and specification of MNRE . The steel structure is to be protected with minimum 80 micron galvanisation(hot dip) and provided with fixed arrangement or dual axis manual tracking arrangement for three times in a day and seasonal tilting are to be regulated to face the sun optimally.(as per requirement) ( 2 nos. 8 module str.)
3710
537950
145
Foundation of Module Mounting Structure: Suitable and stable Reinforced Cement Concrete foundation for dual axis manual tracking SPV Module structure as per drawing. For 8 module structure
14
182600
13042.87
Power conditioning unit with IP54 enclosure :
Supply , transport , installation and commissioning of IP 54 protected enclosured Inverter Unit qualifying IEC 61683-Efficiency measurement and IEC 60068-2-Environment Standard , safety standard suitable for 3 Phase A.C. motor, IGBT based high voltage switching inverter with MPPT technology, to take care of the variation of Sun light and will be suitably mounted inside the metal enclosure. Inverter should have protection against Dry run, Over current, Under current, Over voltage, Under voltage, Short circuit etc. System should be able to run at low sunshine and minimum 7 to 8 hours a day run should be possible during normal sunshine.condition. Inverter should have option to auto start for any short trip off due to low light/ cloudy situation except for dry run. Inverter should be provided with a display to show the various parameter by the user such as Voltage, Current, Solar panel DC voltage, Inverter IGBT temperature, Out put AC voltage, Output frequency, Pump flow (direct or calculated method), Irradiation etc . The system should store the data at a set interval, be capable to transfer it to external storage device and support communication of its operational parameters and logs over Modbus protocol . It should also monitor and save total run time, total water pumped etc. There should be provision for interfacing GPRS based data transmission. d) For 5 HP capacity Pump-motor set
7
398174
56882
Cable and Accessories :
Supplying, fitting and fixings of UV rated Copper Cable laid inside HDPE conduit and other accessories as per followings with necessary connection with the Solar PV Module, MPPT etc.
i. 4.0 Sq mm single core multi studs - 5m(for 2HP) & 26m(for 3/5 HP)
ii. Lugs, HDPE Pipe, Flexible Pipe, Saddle, Cable tie etc. b) For 2 or more structure per structure with 9m distance between sturctures.
14
48076
3434
Earthing: Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe including excavation of soil for installation of Earth Electrode and filling & ramming and connecting to individual structure to earth electrode including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
14
37254
2661
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of 8 swg on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
140
1285
9.18
a) Lighting System at Scheme: (with lighting Pole) :
Dusk to dawn lighting arrangement of at 4 mts height above ground level, with Hot dip galvanised 80 mm x 50 mm , medium duty pipe, with 12 V, 15Ah 2-in-1 Lithium ion/ Ferro- Phosphate battery with in-built 7-11watt LED lamp , 50 Wp solar panel to cover the scheme area. The lighting system should be warranted for 5years from the date of installation.
7
133210
19030
b) Lightning protection (Pole mounted): Lightning protection with 3" X 1.5" G.I pipe of 6m + 1 m height with base flange in proper RCC foundation and S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. Earthing with 65 mm dia GI pipe (Medium) 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. including connection to earth electrodes with 25 X 6mm G.I strip. (Provision of one lightning protection for each scheme as per drawing)
7
74781
10683
Supply and installation of 3 phase electromotor pump-motor set suitable for Solar operation covering 5 years warranty for the following conditions including loading, unloading, transportation etc.:- d) 5 HP ISI marked 3 phase 415 V Pump-Motor set having discharge at required head as below:- iii) Submersible Pump-motor set for LDTW ISI marked as per IS: 8034 with discharge of 7.5 Lps- 5.83 Lps at 30 mts.-35 mts. total head with cable(3m), cover plate, Socket, Flanged Nipple, Rubber Insertion, Nuts& bolts and all other accessories including transportation of Bend, Column Pipes, cable, sluice valve, lay flat hose pipe etc. from Deptt. Store to site within 100km.
7
324373
46339
Testing and commissioning of scheme after completion of all work
7
14000
2000
Comprehensive maintenance charges for 4 years beyond 1 year warranty period (which cover monthly inspection, Yearly training to WUA, to attend breakdown within 3 days and to keep the scheme in operation without lapse of time) c) For 5 HP both for Submersible & Surface pump Note:Total comprehensive maintenance charge is to be withheld in addition to Securirty Deposit. Comprehensive maintenance charges will be released @ i) Rs 0.80 for 2 HP, ii) Rs.0.80 for 3 HP, iii) Rs.0.60 for 5 HP & 10 HP Submersible & Surface per Wp per year at the end of each maintenance period i.e.at the end of 1st year, 2nd year, 3rd year, 4th year& 5th year. In case the “Bidder” does not provide service during the warranty & comprehensive maintenance period, the amount so held up will be forfeited.
38080
114240
3
Insurance @ 2% for Item No. 10, 13, 17 and 19 for a period of 5 years Note:2
Ist year's Insurance charge is to be paid on production of Original Receipt of premium payment. Remaining 4 years Insurance payment is to be withheld which will be released during 2nd, 3rd , 4th & 5th year on production of Original Receipt of premium payment.
0.02
39704
1985209.8
Supplying, fitting and fixing including transportation of sign board for identifying the exact location of MINI RLI scheme (one at road side and other at site) the board will be made 3 mm thick MS plate of size 300 mm x 600 mm and fitted and fixed on 50 mm GI Pipe of IS 1239/90 (part-1) including cutting, welding LS and writting of both sides of Sign board. Base - Yellow, and words - Red. Both bottom end of the stands pipe will be grouted in 1:2:4 CC on a single brick flat soling. This will include one materials and labour complete as per drawing and direction of E.I.C.
1
3677
3677.51
Supplying, fitting & fixing of MS Plateof size 20cmx20cm, 6 mm thick make of two halves(20 cmx10cm) placed over housing pipe of LDTW to rest the supporting clamps,with semi circlar hole of 90 mm dia at centre including locking arrangement between the two halves on both sides, including fitting, fixing of 25mm dia G.I. bend by making a hole on plate for passing submersible cable smoothly and complete in all respect.
7
2679
382.84
Supply of MS Hexagonal Head Bolts & Nuts bearing IS-1363 (Part-I)/ 1992 of product Grade-C with latest amendments for bolts & IS- 1363 (Part-3) / 1992 of Product Grade-C with latest amendments for Nuts properties / Class for Bolt-4.6 & Nuts-4.5. (Inspection at departmental store only).
21
4095
195
Part- C : Supply of materials for LDTW Supply of UPVC Pipes ISI marked IS- 4985 (i)150 mm N.B. PVC 7.5 mm thick Blank Pipe (IS 12818/1997) Medium Casing.
252
283248
1124
ii) Supply of 100 mm nominal dia 5.00 mm thick Blank Pipe (IS 12818/1997) Medium Casing
644
328440
510
iii) 100 mm. Nominal dia PVC 5.00 mm thick ribbed screen / strainer Pipe (IS 12818/1997)
84
68628
817
Supply of 80 mm (N.B) M.S. Column Pipe both screwed & one end socketed. (3 mtr long). Thickness of column pipe 4.0 mm Pipe & socket should be as per IS: 1239 (Part-I&II) & Socket should be as per IS: 554/1999 with latest amendments. BOTTOM
63
302400
4800
Supply of 80 mm (N.B) M.S. Column Pipe one end screwed & other end welded with 80 mm (NB) Standard Flange. Thickness of column pipe 4.0 mm Pipe & socket should be as per IS: 1239 (Part-I&II) & Socket should be as per IS: 554/1999 with latest amendments. TOP
7
38500
5500
Supply of 80 mm (N.B) M.S.Plate Flange duly ISI Marked as per IS-6392/1971
14
5329
380.65
MS HexagonalHead Bolts & Nuts bearing IS-1363 (Part-I)/ 1992 of product Grade-C with latest amendments for bolts & IS- 1363 (Part-3) / 1992 of Product Grade-C with latest amendments for Nuts properties / Class for Bolt-4.6 & Nuts-4.5. Both bolts & Nuts. M 16 x 65 mm
35
6825
195
Supply of Rubber Insertion 5 mm thick with proper reinforcement 2 Ply confirming to IS 638/79 with ISI Mark with latest ammendments suitable for raised surface of MS Flange as per IS 6392/71 (Table-5,11,17). 80 mm dia (Table-17)
21
1155
55
Supply of 80 mm Nominal Size (PD) ISI marked Sluice Valve Pressure designation P.N. 1.6 with hand wheel for water works purpose, C.I. Flanged type confirming to IS: 14846/2000 with Ammendment No. 1 & 2. Components / Parts of Sluice Valves shall be manufactured from basic materials given in Table 1 of IS: 14846 / 2000 with Amdt. 1 & 2. The Valves shall be tested for (Closed end test) against Hydrostatic test requirement.
7
33600
4800
Supply of 80 mm (NB) GI 90 degree Bend as per IS-1239 (Part-II)/1992 with latest amendments, both end welded with flange as per IS 6392/1971, table-17 with latest amendments. Both Bend and flange are duly ISI certification marked.
7
19600
2800
M.S holding Clamp
80 mm dia
7
15295
2185
100 mm dia lay flat Hose
700
119000
170
Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as quired,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all pecials. No separate payment will be made for accesories, pecials.ayment for painting will be made seperately). 80 mm dia. medium quality. (For Delivery pipe)
14
11452
818
3 Core Copper PVC insulated (heavy duty) flat weather proof Electric cable duly ISI certification mark IS:694/1990. 2.50 Sq mm
700
114100
163
SUB TOTAL WITH OUT TAX FOR PART A+B
1
4911834
4911834.32
Add GST@18%. On Item No. 01 to 30 + Item no 44
18
642891
3571619.22
Labour welfare cess @1% On Item No. 01 to 30 + Item no 44+Item No. 47
1
42145
4214510.68
GROSS AMOUNT INLCUDING GST+ CESS
1
5596870
5596870.89
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements