Water Resources Development Directorate Tender

... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Water Resources Development Directorate - WRDD Tender

Works
Energy, Oil and Gas
Electrical and Electronics
Solar Installation and Products
Electrical Works
Eprocure
Opening Date28 Mar 2025
Closing Date22 Apr 2025
Tender Amount₹ 25,36,995 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
110 mm. dia P.V.C. pipe class-II ( with a loose matching coupler,class-II) marking IS No. 4985/ 2000 with latest amending with free solvent cement.

12

284

3408

... More
Coupler(Cl-II) for 140 mm. dia P.V.C. pipe ( extra) I.S. 10124/2009, Part- II with free solvent cement.

11

130

1430

... More
Coupler(Cl-II) for 110 mm. dia P.V.C. pipe ( extra) I.S. 10124/2009, Part- II with free solvent cement.

50

67

3350

... More
110x110x 110 mm. P.V.C. Tee (Part-V) with free solvent cement,I.S. 10124/2009 (Cl-II)

9

347

3123

... More
140x140x 140 mm. P.V.C. Tee (Part-V) with free solvent cement,I.S. 10124/2009 (Cl-II)

3

712

2136

... More
140 x 110 mm Reducer(cl-II) with free solvent cement,I.S. 10124/2009, Part-3.

4

283

1132

... More
140 mm. dia 900 bend (cl-II) ( IS. No. 10124/ 2009 Part- 8 with latest amendment ),with free solvent cement.

2

647

1294

... More
110 mm. dia 600 bend(cl-II) ( IS. No. 10124/ 2009 Part- 8 with latest amendment ) with free solvent cement.

6

378

2268

... More
110 mm. dia 900 bend(cl-II) ( IS. No. 10124/ 2009 Part- 8 with latest amendment ) with free solvent cement.

13

378

4914

... More
140 mm. dia IS. NO. 10124/ 2009 Part- 4 with latest amendment End cap (Cl-III) with free solvent cement.

1

330

330

... More
110 mm.dia IS.NO.10124/2009 Part-4 with latest amendment.PVC End Cap.(Cl-III) with free solvent cement.

2

230

460

... More
110 mm. dia ( IS. No 10124/2009 Part- 6 with latest amendment) F.T.P.(Cl-II) with free solvent cement.

9

310

2790

... More
140 mm. dia ( IS. No 10124/2009 Part- 6 with latest amendment) F.T.P.(Cl-II) with free solvent cement.

2

462

924

... More
Solvent cement extra (Medium duty)

3

425

1275

... More
G.I. Tripod set and Inlet & outlet Pipe Fittings(I No. for 2nd chamber of Drawing) as per drawing and Specification

1

202000

202000

... More
150 mm dia Galv. MS Flanged Pipe with flange as per IS 1239 (Part-I)/2004 & 6392/1971, table 17 Specification.

48

3800

182400

... More
100 mm dia G.I E.R.W. Pipe with flange as per IS 1239 (Part-I)/2004 & 6392/1971, table 17 Specification.

12

2474

29688

... More
900 GI Bend (Both end Flanged) IS marked IS-1239, Galv IS 4736

2

8175

16350

... More
150 mm. dia I.S.I. 14846/2000 Amd No.1 & 2 mark and specification PN- 1.6 sluice valve .

2

9950

19900

... More
100 mm dia C.I. Sluice Valve I.S.I. 14846/2000 Amd No. 1&2 mark and specification PN- 1.6 sluice valve .

2

6300

12600

... More
Ф100 mm NTP /Alfa-Alfa Valve as per technical specification

9

3300

29700

... More
80X65mm M.S. flanged reducer

2

1381

2762

... More
100X80mm M.S. flanged reducer

4

1633

6532

... More
M.S Foundation Bolt for Pump Motor sets manufactured from 20 mm nominal diameter M.S Rod as per IS 2026/1992. Total length of bolts is 275+10 mm in length & 20 mm in nomonal diameter with Nuts & 2 nos washer,the average weight of such bolt 1.5 kg per bolt with tolerance in weight of each bolt @ +/-10%

8

223

1784

... More
Foundation Bolt, For Distrubution Chamber Quadruped (1.1 Kg each) manufactured from 20 mm nominal dia MS rod as per IS 2062/2002.Total length of the bolt is 375+_ 10mm having welded head 80+- 10 mm in length and 20 mm nominal dia with Nut & 2 Nos. Washer.

14

223

3122

... More
M.S. Hexagonal Head Bolts & Nuts conforming to IS-1363 (Part-I) 1992 product grade - C with latest ammedments for boths IS-1363 (Part-3) / 2002 of product grade C with latest amount for nuts properties / class for bolt 4.62 nuts for 4.5. ISI Marked.

-

-

-

... More
M-20 X 80 mm

45

176

7920

... More
M-20 X 100 mm

8

176

1408

... More
M-16 X 65 mm

38

176

6688

... More
M-16 X 80 mm

10

176

1760

... More
M-16 X 50 mm

16

176

2816

... More
Foot valve leather washer 100mm dia

2

234

468

... More
Sal Sleeper (4ft X 6in X 4 in)

2

2200

4400

... More
Compresed Asbestos fibre jointing for Quadruped & Tripod set( for raised surface of Flange as per IS-6392)

-

-

-

... More
300mm.dia(Table-5)

2

1018

2036

... More
Rubber Insertion I.S. 638/1979 with latest amendment sheet 5 mm. 2 Ply. ( for raised surface of Flange as per IS-6392)

-

-

-

... More
150 m dia Ruber Insertion(Table-17)

18

166

2988

... More
150 m dia Ruber Insertion(Table-5)

8

166

1328

... More
100 m dia Ruber Insertion(Table-17)

21

129

2709

... More
80 m dia Ruber Insertion (Table-17)

11

95

1045

... More
3C X 4 sqmm copper cable conforming to IS 694 [Busbar to 32 A, TP Main switch and 32 A TP switch to Motor starter]

3

239

717

... More
2 X 3C X 2.5 sqmm copper cable conforming to IS 694 in 25 mm GI conduit (ISI-Medium quality)[ Star-Delta Motor starter to Motor]

10

326

3260

... More
Laying of Water Transmission Arrangement for Mini RLI Scheme

-

-

-

... More
Earth work in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone) including removing, spreading, or stacking the spoils, within a lead of 75 meter as directed. The item includes necesary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1500 mm (considering 50 mm clearence)

-

-

-

... More
For foundation Blocks of Tripod

3.4

119

405.52

... More
For spout Chambers

17

119

2027.59

... More
Earthwork in excavation of field trenches as per design section and alignment for laying of pipe lines(PVC,RCC,ACP etc) upto a depth of 1500 mm all sorts of soil including removing,spreading or stacking extra earth as directed.The item includes necessary trimming of sides trenches,levelling,dressing and ramming the bottom as required complete. For Pipe Trenches etc.

1000

99

99010

... More
Earth work in filling in treches after laying pipelines (P.V.C, R.C.C, A.C.P etc) with good earth obtained from excavation of field trenches in layers not exceeding 225 mm, including watering and ramming etc layer by layer complete (Payment to be made on the basis of mesurement of finished quantity of work)

950

66

62709.5

... More
Laying of UPVC pipes of different diameters within field trenches in curve/ straight line including using UPVC fittings, Viz. Horizontal and Vertical Bends, riser pipes, Tee Reducer etc.and making leak proof joints with couplers after roghening the surface with wire brush and emery paper and applying solvent cement (The rate is inclusive of transport of pipes, fittigs and solvent cement to be supplied by deptt.) all complete asper direction of Engineer-In- charge.

-

-

-

... More
140 mm.OD.

294

10

2981.16

... More
110 mm. OD.

1200

8

10464

... More
Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand.

-

-

-

... More
For foundation Blocks of Tripod

3.5

266

931

... More
For spout Chamber

42

266

11172

... More
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm. as directed and consolidating same by thorough saturation with water ramming complete, including the cost of supply of sand. (Payment to be made on measurement of finished quantity)

-

-

-

... More
For foundation Blocks of Tripod

0.3

572

171.77

... More
For spout Chamber

5.7

572

3263.54

... More
Ordinary Cement Concrete (mix 1:1.5:3) with graded stone chips (20 mm. nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevent IS codes.Pakur Variety

-

-

-

... More
For foundation Blocks of tripod

0.52

5295

2753.72

... More
Ordinary Cement Concrete (mix 1:2:4) with graded stone chips (20 mm. normal size) excluding shuttering and reinforcement, if any, in ground floor. as per relevent IS Code. a) Pakur Variety

-

-

-

... More
For foundation Blocks of tripod

1.03

4728

4870.73

... More
For spout Chamber

4.45

4728

21043.43

... More
Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor). Above 30mm to 37 mm. thick wooden shuttering as per decision & direction of Engineer-in-charge.

-

-

-

... More
For foundation Blocks of tripod

5.2

328

1705.6

... More
For Spout Chamber

12.75

328

4182

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor / upto 4m. (i) Tor steel/Mild steel(SAIL/TATA/RINL) i)For foundation Blocks of tripod

0.03

55335

1770.74

... More
Brick work in cement mortar (1 : 6) with first class kiln burnt bricks including racking out joints, scaffolding and other incidental works etc. complete in foundation and plinth. (a) In foundation & plinth

10

4243

42430

... More
125 mm. thick brickwork with 1st class bricks in cement mortar (1 : 4) in ground floor.

8.1

592

4795.2

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints, including throating, nosing and drip course, scaffolding/staging where necessary (ground floor) excluding cost of chipping over concrete surface.with (1:6) cement mortar, 15 mm. thick plaster

113

150

16950

... More
Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. NOTE : Cement 0.152 cu.m. per 100 sq.m.

113

34

3842

... More
Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.W. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of Engineer-in-Charge.150 mm. dia. ERW pipe.

-

-

-

... More
150 mm. dia. ERW pipe.

48

134

6472.32

... More
100 mm. dia. ERW pipe.

12

82

990.12

... More
Erection, fitting, fixing of set of M S tripod inlet and outlet pipe fittings for MINI RLI Scheme.(Rate inclusive of transportation from departmental store to work site)

1

12466

12466.74

... More
Labour charges for fitting, fixing 100 mm. Dia. Alfa-AIfa valve with 110 mm. dia. P.V.C. riser pipe with the help of flanged P.V.C. tail-piece by joining the P.V.C. End of Tail-piece and riser pipe with coupler and flanged end of Tail-piece and Alfa-Alfa valve with rubber insertion, nuts and bolts etc. complete.

9

108

975.96

... More
Labour charges for fitting, fixing (150 x 140) mm dia M S reducer with 140 mm dia UPVC pipe with the help of FTP (flanged tail piece) by joining the PVC end of the tail piece and 140 mm dia UPVC pipe with coupler and flanged end of tail piece and expander with rubber insertion, nuts and bolts etc. complete. (Rate inclusive of transportation from departmental store to work site).

2

108

216.88

... More
Labour charges for fitting, fixing 150 mm.& 100 mm Dia Sluice Valve with rubber insertion, nuts and bolts etc. complete.

4

54

218.76

... More
Suppling 1 mtr x 0.6 m x 24 swg MS board contaning list of spout wise water users by making numbers of spout as directed by EIC. The board should have base colour - Black and words - White to be fitted and fixed on the wall of the pump house.

1

942

942.95

... More
Installation of Diesel Engine /Electro-Motor pumping set of any make / brand and for RLI scheme on pump foundation over SAL sleeper (to be supplied departmentally) by fixing nuts and bolts and making connection of suction hose and foot valve with necessary fittings at the inlet end of the water pump and fitting fixing of 90° M S priming bend, sluice valve and delivery hose with all necessary fittings at the delivery end of the water pump, duly connected with the pipe line, maintaining proper alignment and level including cutting holes on the wall of the pump house where necessary, mending good damages after completion of the works as per direction of Engineer-in-charge. (Pump set and all accessories will be supplied departmentally). c) For Mini R.L.I. Scheme.

2

723

1446.48

... More
Testing of pipe line system against leakages by filling the distribution chamber with water and supplying water through the entirepipe line net work for at least 4 (four) hour by running the departmental Deasel Engine pumping set, including supplying necessary fuels & lubricants and hiring and transporting tools and plants all complete as per direction of Engineer-in-Charge.

1

2494

2494.1

... More
Carriage charge @4% on every item from Sl. no-2.01 to 2.22 excluding Sl. No-2.01, 2.02

0.04

159551

6382.05

... More
Installation of Sloar Module and Accessories

-

-

-

... More
Solar Module: Supply , transport , installation and commissioning of ISI marked Solar Modules as per following specification: 1. Cell: Indigenous mono crystalline silicon SPV cells 2. Solar Module: Monocrystalline cell with PERC technology / module with bifacial cell. 3. Standards: ISI marked as per IS 14286 and having certification of IEC 61853(1), 61730(1&2), 61710 4.Modules must qualify to IS 170210 (Part 1) 5.Min. Efficiency: 19.5%. 6. Fill factor: More than 75% . 7. Module wattage mismatch in the SPV array: within ±3% 8. Wattage output warranty:Should not be less than 90% at the end of 10 years and 80% at the end of 25 years. 9.The power output of individual PV modules used in the PV array, under STC: minimum 300 Wp. Necessary test certificates also to be supplied. For detail information please see Cl. no. 2.1 of technical specification .

-

-

-

... More
For 5 HP Off-grid / On-grid Solar Water Pumping System with Monocrystalline/ Monocrystalline PERC/bifacial SPV modules - 5400-5800 Wp.

11000

32

355190

... More
Module Mounting Structure : Supply , transportation & installation of G.I manual tracking / Fixed structure made of MS hollow sections, pipes, plates, angles etc as per IS:4923, IS:1161/1239, IS:1079/2062, to hold min 300 Wp SPV Module as per drawing and technical specification. The steel structure is to be protected with minimum 80 micron galvanisation(hot dip) and provided with fixed arrangement or dual axis manual tracking arrangement for three times in a day and seasonal tilting to face the sun optimally. The approximate weight of the Module Mounting Structure given in Clause no.5.1 should be followed.( 1 no. 6 module + 1 no. 4 module Fixed str.- 2 sets)

1260

157

197820

... More
Foundation of Module Mounting Structure: Suitable and stable Reinforced Cement Concrete foundation for dual axis manual tracking SPV Module structure as per approved drawing.

-

-

-

... More
For 4 module structure

2

11173

22347.04

... More
For 6 module structure

2

12786

25573.62

... More
Power conditioning unit with enclosure : Supply , transport , installation and commissioning of Solar Power conditioning Unit consisting of following components and features: 1) Variable frequency Drive with inbuilt MPPT, voltage range suitable for operating pump-motor set of 1HP to 20 HP, detail mentioned in 2) Power input : DC source for 1HP, 2HP and 3HP. 3) Power input : AC / DC source or hybrid for 5HP and above. 4) Incomer: DC MCB 2 Pole 16 amp upto 5 HP, 25 amp for 7.5HP and 10 HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-2 5) Incomer: AC MCB 4 pole 16 amp for 5.0 HP, 25 amp for 7.5HP and 10 HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-2 6) Type II DC SPD of 40 KA. 7) Type II AC SPD of 40 KA for AC/ DC or Hybrid input. 8) Dual input (solar/Grid) 25 amp changeover switch for 5HP and 7.5 HP, 40 amp for 10 HP, 63 amp for 15 to 20 HP 9) Reverse protection diode 1600 VDC with heat sink. 10) Data Logger. 11) Remote monitoring system. 12) Should have built –in EMC filters . 13)IP 65 glands for cable in and out. 14) Min. IP 54 enclosure. For detail features, protections, RMS, Communication architecture, Security, Data storage, tolerance of various parameters, standards to be qualified, etc. please refer to Cl. 6.1 of technical qualification. Note: AC SPD, AC MCB and Selector switch to be provided only for item no. 3(g), to 3(l).

-

-

-

... More
For 5 HP capacity Pump-motor set with DC input

2

56882

113764

... More
Cable and Accessories : Supplying, fitting and fixings of UV rated Copper Cable laid inside HDPE conduit and other accessories as per followings with necessary connection with the Solar PV Module, MPPT etc. i. 4.0 Sq mm single core multi studs - 5m(for 1HP/2HP/3HP) & 20m(for 5/7.5/10/15/17.5/20 HP) ii. Lugs, HDPE Pipe, Flexible Pipe, Saddle, Cable tie etc

-

-

-

... More
for 2 or more Structure per Structure with 9 m distance between structures.

4

3434

13736

... More
Earthing: Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe including excavation of soil for installation of Earth Electrode and filling & ramming and connecting to individual structure to earth electrode including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.

4

2661

10644

... More
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of 8 swg on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages

80

13

1040

... More
a) Lighting System at Scheme: (with lighting Pole) : Dusk to dawn lighting arrangement of at 4 mts height above ground level, with Hot dip galvanised 80 mm x 50 mm , medium duty pipe, with 12 V, 15Ah 2-in-1 Lithium ion/ Ferro- Phosphate battery with in-built 7-11watt LED lamp , 50 Wp solar panel (min 19% Eff.) to cover the scheme area. The lighting system should be warranted for 5years from the date of installation.

1

19030

19030

... More
b) Lightning protection (Pole mounted): Lightning protection with 3" X 1.5" G.I pipe of 6m + 1 m height with base flange in proper RCC foundation and S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. Earthing with 65 mm dia GI pipe (Medium) 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. including connection to earth electrodes with 25 X 6mm G.I strip. (Provision of one lightning protection for each scheme as per drawing))

2

10683

21366

... More
Supply and installation of 3 phase electromotor pump-motor set suitable for Solar operation covering 5 years warranty for the following conditions including loading, unloading, transportation etc.:- c) 5 HP ISI marked 3 phase 415 V Pump-Motor set having discharge at required head as below:- i) Monoblock Surface Pump-motor set ISI marked as per IS: 9079 for mini RLI scheme with discharge of 13.8 Lps at 18 mts. total head with 100/80 mm dia. reinforced PVC suction pipe (20m) and delivery pipe(10mts), foot valve, nipple, priming bend Cable and all other required accessories to complete connection of suction and delivery side .

2

62406

124812

... More
Testing and commissioning of scheme after completion of all work

2

2000

4000

... More
b) Supply fitting and fixing of Hot dip Galvanised ( min 80 micron) / Powder Coat painted / Galvanised M.S Kiosk Box of 800(L) X 500(W) X 650(H) and total height with legs is 950mm (above ground) including foundation(as per drawing) for mounting of motor-pump set including transportation, - For 5 HP surface pump.

2

14157

28314

... More
Comprehensive maintenance charges for 4 years beyond 1 year warranty period (which cover monthly inspection, Yearly training to WUA, to attend breakdown within 3 days and to keep the scheme in operation without lapse of time) c) For 5 HP both for Submersible & Surface pump Note: Total comprehensive maintenance charge is to be withheld in addition to Securirty Deposit . Security Deposit will be released after expiry of warranty period of 1 year & Comprehensive maintenance charges will be released @ Rs.0.75 per Wp per year at the end of each maintenance period i.e.at the end of 2nd year, 3rd year, 4th year, 5th year. In case the “Bidder” does not provide service during the warranty & comprehensive maintenance period, the amount so held up will be forfeited

11000

3

33000

... More
Insurance @ 2% for Item No. 3.01, 3.04, 3.08, and 3.10 for a period of 5 years. Note:2 Ist year's Insurance charge is to be paid on production of Original Receipt of premium payment. Remaining 4 years Insurance payment is to be withheld which will be released during 2nd, 3rd , 4th & 5th year on production of Original Receipt of premium payment.

0.02

612796

12255.92

... More
Remote monitoring for 5 years: Provision for remote monitoring for the pumps must be made in the pump controller through an integral arrangement having following basic functions: a. Controller must be assigned with a unique serial number and its live status must be observed remotely on online portal through login credentials. b. Live status must indicate whether controller is ON/ OFF. The parameters i.e. the water output, water flow rate, in fault condition, array input voltage/ current, power and motor frequency should at logged at an interval of 10 minutes c. Controller must have a back up to store the data locally ( at least for 1 year) supply & installation of GSM/GPRS based Data Transmitter or Modem and to provide remote monitoring service to transmit the parameters to central server from the solar pumping system with time stamp at user-defined interval and report generation at the buyer end. (Refer Technical Spec.)

1

21850

21850

... More
Cleaning and washing of modules once in a month with clear water to remove deposited dust and dirt on the module surface and keep the modules clean throughout the year. The activity to be performed for eight months in a year excluding four monsoon months. A log book should be maintained at thr site for the said purpose.

160

300

48000

... More
Supplying, fitting and fixing including transportation of sign board for identifying the exact location of MINI RLI scheme (one at road side and other at site) the board will be made 3 mm thick MS plate of size 300 mm x 600 mm and fitted and fixed on 50 mm GI Pipe of IS 1239/90 (part-1) including cutting, welding LS and writting of both sides of Sign board. Base - Yellow, and words - Red. Both bottom end of the stands pipe will be grouted in 1:2:4 CC on a single brick flat soling. This will include one materials and labour complete as per drawing and direction of E.I.C.

1

3677

3677.51

... More
Add GST @ 18 % on PWD and WRDD Items from Item No. 2.01 to 3.17

0.18

1386505

249571.07

... More
Add Cess @1% from Item No.2.01 to 4.00

0.01

1636077

16360.77



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.