Water Resources Development Directorate Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Water Resources Development Directorate - WRDD Tender

Works
Civil And Construction
Irrigation Work
Eprocure
Opening Date29 Aug 2024
Closing Date24 Sep 2024
Tender Amount₹ 37,01,461 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Summary

Wbwrdd/ee(am)/hwh/enit 15/24-25

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of 200 mm dia P.V.C. Equal Tee as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)

9

13338

1482

... More
Supply of 140 mm dia P.V.C. Equal Tee as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)

15

10680

712

... More
Supply of 200 mm dia F.T.P. as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)

7

9282

1326

... More
Supply of 160 mm dia F.T.P. as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)

20

13400

670

... More
Supply of 160 X 140 mm P.V.C. Reducer (Class-II) as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)

16

5248

328

... More
Supply of 200 X 140 mm P.V.C. Reducer (Class-II) as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)

10

9940

994

... More
Supply of 200 X 160 mm P.V.C. Reducer (Class-II)

6

4542

757

... More
Supply of 200 X 60º P.V.C. Bend s per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)

3

5328

1776

... More
Supply of 140 X 60º P.V.C. Bend s per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)

10

6470

647

... More
Supply of 140 X 90º P.V.C. Bend s per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)

22

14234

647

... More
Supply of 200 mm dia P.V.C. End Cap(Cl-III)

4

3020

755

... More
Supply of 140 mm dia P.V.C. End Cap(Cl-III)

4

1320

330

... More
Supply of 200 mm dia P.V.C.Extra Coupler (Class-II)

30

9030

301

... More
Supply of 140 mm dia P.V.C.Extra Coupler (Class-II)

80

10400

130

... More
Supply of 160 mm dia P.V.C.Extra Coupler (Class-II)

4

872

218

... More
Supply of Solvent Cement(Extra)

5

2125

425

... More
GI Quadrupped Set for Midi RLI Scheme, All material ISI marked (As per appvd. existing drawing & tech. spec.)

1

421500

421500

... More
100 mm dia 90º G.I Bend (both end flanged) long bend With priming arrangement, ISI marked-IS-1239, Galv- IS 4736 (As per appvd. existing drawing & tech. spec.)

2

7902

3951

... More
100 mm.dia Galv. MS Flanged Pipe ISI marked- IS- 1239, Galv- IS 4736(As per appvd. existing drawing & tech. spec.)

24

59376

2474

... More
150 mm.dia Galv. MS Flanged Pipe ISI marked- IS- 1239, Galv- IS 4736 (4.8mm)(As per appvd. existing drawing & tech. spec.)

72

273600

3800

... More
VALVES AND OTHER ACCESSORIES 150 mm dia C.I. Sluice Valve with hand wheel, ISI marked- IS 14846 (As per appvd. existing tech. spec.)

3

29850

9950

... More
100 mm dia C.I. Sluice Valve with hand wheel, ISI marked- IS 14846 (As per appvd. existing tech. spec.)

2

12600

6300

... More
150 mm dia (type-C) Alfa Alfa Valve (nipple type) with handwheel 01 no. for 04 nos valve, as per IS 210/2009 (As per appvd. existing drawing & tech. spec.)

13

57655

4435

... More
Supply & Transportation of 100 mm dia C.I. Foot valve, flanged end & swing type. The disc face will be made of leather and strainer made of galvanized steel.The Valves shall be tested for (closed end test) against Hydrostatic test requirement

2

6600

3300

... More
Supply of MS Hose Clamp Supply & Transportation of 100 mm dia MS Heavy Duty Hose Clamp fitted with bolts & nuts (2 sets), 2 mm thick, 30 mm width. One coat of Black Japan

20

2240

112

... More
Supply of C.I. Flanged Tail piece/Nipple Supply & Transportation of 100 mm dia C.I. Combined Tail Piece with adopter both side grooved, with 7 nos. grooves.

4

2640

660

... More
Supply & Transportation of 100 mm dia C.I. Tail Piece with one end flanged and other end grooved, overall length (175+/-15) mm. (23 mm flange thk) with 7 nos. grooves.

8

6880

860

... More
Supply & Transportation of Foundation Bolt, manufactured from 20 mm nominal diameter MS Rod as per IS:2062/1992. Total length of the Bolt is 375 +10 mm having welded head 80 +10 mm in length and 20 mm in nominal diameter nut and 2 nos. washer, The average weight of such bolt to be 1.5 kg. per bolt with tolerance in weight of each bolt @ +10%.

30

6690

223

... More
Supply & Transportation of GI Hexagonal Head Nuts and Bolts conforming to IS 1363(Part-I)/1992 of product grade C with latest amendmends for Bolts & IS 1363(Part-3)/1992 of product Grade-C with latest amendments for Nuts properties /Class for Bolt-4.6 & for Nut-4.5. ISI marked. a) M 16 mm X 65 mm.

45

7920

176

... More
c) M 16 mm X 80 mm.

30

5280

176

... More
d) M 16 mm x 50 mm

27

4752

176

... More
e) M 20 mm X 80 mm.

57

10032

176

... More
f) M 20 mm X 100 mm.

32

5632

176

... More
ELECTRO MOTOR PUMP SETS, ISI MARKED, IS 12615 & IS 6595, Monoblock as per IS 9079 (read with latest ammendment for all IS) 100 m3/hr,18 m head. (10 HP) (As per appvd. existing tech. spec.)

2

165312

82656

... More
MOTOR CONTROLLER, IS 60947 10 HP 3 phase Electromagnetic Star-Delta motor controllers with 4 pole heavy duty Power contactor, single phasing preventer and normal protective features, MCB, Indicators, push buttons, Ammeter & Voltmeter, all in IP54 enclosure of min 16swg. C R sheet steel, 10 tank process powder coat painted and as per technical specification

2

35864

17932

... More
BUSBAR CHAMBER, IS 60947 63 A Busbar Chambers (As per appvd. existing dwg & tech. spec.)

1

6980

6980

... More
63 A Switch Fuse Unit TPN (As per appvd. existing tech. spec.)

1

8418

8418

... More
32 A Switch Fuse Unit TPN (As per appvd. existing tech. spec.)

2

8396

4198

... More
Kiosk Box : Supply fitting and fixing of Hot dip Galvanised (min 80 micron) / Powder Coat painted M.S. Kiosk Box / Stainless steel kiosk of SS304 of 710(L) x 410 (W) x 740 (H) and total height with legs is 1670 mm for mounting of Motor Pump set including transportation, grouting in cement Concrete as shown in the drawing.

1

14157

14157

... More
Supply & Transportation of 500 mm dia (Table-5) Compressed Asbestos Fibre Jointing for Quadruped & Tripod set(for raised surface of flange as per IS:6392).

3

3654

1218

... More
100 mm dia Suction Hose, P.V.C.Flexible Hose pipe, ISI marked - IS 15265

60

46440

774

... More
Supply & Transportation of 100 mm dia Foot Valve Leather Washer best quality brand (Imperial/Techno/Burhani).

2

468

234

... More
Supply and transport of Rubber Insertion 5 mm thick with proper reinforcement 2 ply conforming to IS 638/79 with ISI Mark with latest amendmends suitable for raised surface of MS flange as per IS 6392/71 (Table 5, 11 & 17) with standard bore holes. 200 mm dia Rubber Insertion (Table No.11)

5

880

176

... More
200 mm dia Rubber Insertion (Table No.5)

8

1408

176

... More
150 mm dia Rubber Insertion (Table No.17)

35

5845

167

... More
150 mm dia Rubber Insertion (Table No.5)

10

1670

167

... More
100 mm dia Rubber Insertion (Table No.17)

12

1548

129

... More
80 mm dia Rubber Insertion (Table No.17)

9

855

95

... More
WTA Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone), including removing, spreading or stacking the spoils, within a lead of 75 m as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1500 mm.

15.35

1830

119.27

... More
Earthwork in excavation of field trenches as per designed section & alignment for laying of pipe lines(PVC,RCC,ACP etc.) upto a depth of 1500 mm in all sorts of soil including removing, spreading or stacking extra earth as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom as required complete.

1678.68

166206

99.01

... More
Laying of P.v.C. pipes of different diameters within field trenches in curve /straight line using P.V.C. fittings, viz. Bend, Tee, Reducer etc. and making leak proof joints with couplers after roughening the surface with wire brush and emery paper and applying solvent cement (The rate is inclusive of transport of pipes, fittings and solvent cement to be supplied by Deptt.) all complete as per direction of Engineer-in-Charge. b) 200 mm dia

900

9756

10.84

... More
c) 140 mm dia

1500

15210

10.14

... More
Earth work in filling in trenches after laying pipe lines (PVC,RCC,ACP etc.) with good earth obtained from excavation of field trences in layer not exceeding 225 mm , including watering & ramming etc. layer by layer complete. (payment will be made on the basis of measurement of finished quantity of work)

1625.88

107324

66.01

... More
Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed and consolidated the same by through saturation with water ramming complete including the cost of supply of sand.

5.74

5463

951.83

... More
Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

43.32

15465

357

... More
Ordinary Cement concrete (Mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement , if any, in ground floor as per relevant IS codes.(a) Pakur vareity.

7.23

39351

5442.74

... More
Ordinary Cement concrete (Mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement , if any, in ground floor as per relevant IS codes.(a) Pakur vareity .

1.63

9924

6088.68

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 metre using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). 25 mm. to 30 mm. thick wooden shuttering as per decision & direction of Engineer-In-Charge.

22.19

7411

334

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. For works in foundation, basement and upto roof of ground floor / upto 4m. Tor steel/Mild steel ( SAIL/ TATA/RINL) i) For foundation Blocks of Water Distribution System

0.13

7043

55027.66

... More
Brick work with Ist class brick in cement mortar (1 : 6) . (a) In foundation and plinth

2.84

15029

5292

... More
Brick work with Ist class brick in cement mortar (1 : 6) . (a) In superstructure ground floor.

14.82

81717

5514

... More
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.

27

19494

722

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar (c) 15 mm thick plaster.

123.87

17837

144

... More
Neat cement punning about 1.5 mm. thick in wall dado, floor, drain, door and window sill etc. Complete.

123.87

4211

34

... More
Fitting and fixing of M.S. / G.I. / C.I.accessories and special in pipe line (accessories & special to be supplied departmentally) including supply of jointing materials viz.rubber insertion, nuts & bolts, havoc Zink (Zink Oxide) complete as per direction of Engineer-in-Charge. a) 150 mm dia sluice valve.

3

164

54.69

... More
b) 100mm. dia. C.I. Sluice Valve

2

111

55.69

... More
Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.W. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of Engineer-in-Charge. (i) 150 mm. dia. ERW pipe.

72

9708

134.84

... More
(i)(b) 100 mm. dia. NB ERW/MS pipes.

24

1980

82.51

... More
Erection, fitting, fixing of set of M S Quadruped inlet and outlet pipe fittings for HDTW/MIDI RLI Scheme.(Rate inclusive of transportation from departmental store to work site).

1

16622

16622.32

... More
Labour charges for fitting, fixing 150 mm. Dia. Alfa-Alfa valve with 140 mm. dia.P.V.C. pipe with the help of flanged P.V.C. tail-piece by joining the P.V.C.End of Tail-piece and riser pipe with coupler and flanged end of Tail-piece and Alfa-Alfa valve with rubber insertion, nuts and bolts etc. complete.

13

1458

112.21

... More
Supplying, fitting and fixing including transportation of sign board for identifing the exact location of MIDI RLI scheme (one at road side and other at site) the board will be made of 3 mm thick MS plate of size 300 mm × 600 mm and fitted and fixed on 50 mm GI Pipe of IS 1239/90 (part-1) including cutting, welding and writting of both sides of Sign board. Base - Yellow, and ward Red. Both bottom end of the stands pipe will be grouted in 1:2:4 CC on a single brick flat soiling. This will include materials and labour complete as per drawing and direction of EIC.

1

3677

3677.51

... More
Installation of Diesel Engine Pumping set of any make / brand and for RLI scheme on pump foundation over SAL sleeper (to be supplied departmentally) by fixing nuts and bolts and making connection of suction hose and foot valve with necessary fittings at the inlet end of the water pump and fitting fixing of 90° M S priming bend, sluice valve and delivery hose with all necessary fittings at the delivery end of the water pump, duly connected with the pipe line, maintaining proper alignment and level including cutting holes on the wall of the pump house where necessary, mending good damages after completion of the works as per direction of Engineer-in-charge. (Pump set and all accessories will be supplied departmentally). b) For Midi R.L.I. Scheme.

2

1929

964.64

... More
Testing of pipe line system against leakages by filling the distribution chamber with water and supplying water through the entire pipe line net work for at least 4 (four) hours by running the departmental Deasel Engine pumping set, including supplying necessary fuels & lubricants and hiring and transporting tools and plants all complete as per direction of Engineer-in-Charge. ii) For Midi R.L.I.

1

3324

3324.84

... More
Carriage charge on every item from Sl. No- 52 to 76 excluding Sl. No-52, 53, 56 & 76

1

11342

11342.68

... More
Adding 18 % GST ( Item No-52 to 77)

1

103247

103247.22

... More
Add Cess 1%( Item No-52 to 78)

1

6768

6768.43

... More
Internal Wiring Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment 2 Way

1

270

270

... More
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection Legrand DP 32 A

1

322

322

... More
Wiring from MCB SS Enclosure to Busbar by the following size of 1.1KV grade single core stranded 'FR' PVC insulated and unsheathed copper wire (Brand Approved by EIC) in 25 mm PVC casing-capping (Precision make) including necessary PVC clips fittings etc. 2X 36/0.3 (2.5 Sq mm) + 1 X 22/0.3(1.5 Sq mm) ECC

5

510

102

... More
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips fittings etc. to light/fan point with piano key type switch (Anchor Make ) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necessary connections and making earthing attachment and mending good damages to building works. [PVC casing capping and Switch board both on surface] (b) Avg Run 6 run meter

4

2600

650

... More
Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips fittings etc. with S & F 5A 3 pin flush type plug socket with piano key type switch (Anchor make) fixed on PVC switch board on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping and plug box both on surface] (a) Onboard

1

67

67

... More
Supplying and fixing of 240/415 V MCB of breaking capacity 10 kA & C characteristics on DIN rail of existing DBs and necessary connection. Legrand Single Pole 6-32 amp.

1

190

190

... More
Supply & Fixing angular batten holder (Anchor) on 75 mm dia PVC round block / round bakelite on wall/ceiling.

2

76

38

... More
Supplying & Fixing bulk head light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 8watt CFL.

2

1158

579

... More
Fixing only TPN switch fuse units in Sheet Steel enclosure with HRC fuses on angle iron frame on wall for 200A

1

280

280

... More
Supplying and fixing sheet steel (16SWG) cable end box on TPN SFU enclosure with nuts bolts etc incl. powder coated painting.

1

567

567

... More
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables : For 3½ core upto 70 sqmm.

1

212

212

... More
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket(Dowels) make, tapes, anticorrosive paste & jointing materials : For 3½ core 70 sqmm cable.

1

263

263

... More
Fixing only Sheet Steel TP/TPN Main Switch (Rewirwable type)/ Change over on Flat Iron Frame/Angle Iron Frame on wall (63 Amps, 415 Volt) On angle iron frame

2

430

215

... More
Fixing only of 4 Bars 200 A, 415 V M.S. sheet metal busbar chamber on angle iron frame on wall .

1

486

486

... More
Fitting and Fixing of Star Delta starter (for 20 HP motor contol) with nuts and bolts fixed on angle iron frame on wall and making necessary connection with the electrical cables.

2

480

240.45

... More
Fixing only Voltmeter/Ammeter with screws & other fixing materials incl.making necessary holes and connections

3

171

57

... More
Fixing only Single Phasing Preventor on flat iron frame on wall

2

260

130

... More
Supplying and Drawing with 1.1 KV, PVC flexible 'FR' cables copper conductor conforming to IS 694 in suitable size with fitting and fixing on wall , including making necessary connection to the pre-fixed devices with all necessary accessories like saddle, screw, clips, gland, socket etc. conforming to IEE regulation and as per direction of EIC.(Brand: Gloster/Havells/Finolex) (b) For midi RLI (i) 4Cx 16 sqmm Copper cable conforming to IS 694 in [63 A TPN switch to Busbar]

1.5

1543

1028.76

... More
(ii) 3C X 10 sqmm copper cable conforming to IS 694 [Busbar to 32 A. TP Main switch and 32 A TP switch to Motor starter]

3

1665

555.23

... More
(iii) 2 X 3C X 4 sqmm copper cable conforming to IS 694 in 32 mm GI conduit (lSI Medium quality)Star-Delta Motor starter to Motor]

20

10655

532.77

... More
Supplying & fixing of EI danger Board 4"x 6" in two distinguishing position . As per IEE regulation.

2

110

55

... More
Earthing with 50 mm dia Galvanized iron pipe 3.64 mm thick X 3.04 mts. long and 1X4 SWG G.I.(Hot Dip) Wire (4 mts. Long ) 13 mm dia X 80 mm long G.I. Bolts, double nuts and double washer including S&F 15 mm dia G.I. Pipe protection (1 mts) long to be fitted with bitumen partly under the ground level and partly above the ground level driven to an average depth of 3.65 mts. below the ground level. By ISI-Medium G.I. Pipe

2

2738

1369

... More
Supplying and fixing earth bar of galvanized (hot dip) M.S. Flat 40 mm × 6 mm on wall having clearance of 6 mm. from wall including providing drilled holes on busbar complete with G.I. bolts, nuts, washers spacing insulators etc. as required for tapping.

0.8

155

194

... More
Connecting the equipments to earth busbar including supplying and fixing G.I. (hot dip) Wire on wall/floor with stapples burried inside floor/wall as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. By Solid 6 S.W.G. GI Wire

40

520

13

... More
Insulation testing of internal wiring of Pump House/Kiosk Box including wiring of electric Motor & other ancilary equipments by means of Megger

1

165

165.02

... More
Add GST 18 %( Item No-80 to 104)

1

4661

4661.16

... More
Add Cess 1%( Item No-80 to 105)

1

305

305.57

... More
PCC POLE 9 MTR

11

112181

10198.28

... More
M.S.CHANNEL(100*50)

0.05

5051

109813.95

... More
M.S. CHANNEL (75*40)

0.22

23879

110043.09

... More
M.S. ANGLE(65*65*6)

0.2

22059

108667.24

... More
M.S. FLAT (65*6)

0.13

15391

117493.74

... More
11KVPOLYMER COMP. WH FTTG PIN INSL 5KN

33

8045

243.79

... More
11KVPOLYMER COMP. WH FTTG DISC INSL 45KN

18

3296

183.15

... More
STRAIN HARDWARE'S for 50/30 sqmm cond

18

5900

327.83

... More
SHACKLE INSULATOR

2

46

23.34

... More
SHACKLE STRAP BIG 9"

9

532

59.21

... More
D.I. CLAMP

1

47

47.83

... More
G.I. EARTH SPIKE(1.83M)

13

4783

367.98

... More
H.T. STAY SET COMPLETE(1.83M)

14

11141

795.83

... More
H.T. GUY INSULATOR

14

731

52.24

... More
G.I.STAY WIRE 7/10 for HT

0.08

11954

142310.93

... More
G.I.WIRE 6 SWG (5MM)

0.03

3558

136865.98

... More
ACSR CONDUCTOR 50 sqmm

1.37

85150

62290.12

... More
DIST. TRANSFORMER 25KVA

1

103528

103528.11

... More
PVC CABLE 4 Core 50sqmm

0.04

7311

166180.42

... More
P.G. CLAMP 50 sqmm

9

1690

187.88

... More
G.I. TURN BUCKLE

2

562

281.47

... More
12 KV L.A.

3

1572

524.23

... More
11KV TPGO ISOLATOR 200

1

10384

10384.98

... More
CAUTION BOARD

1

160

160.18

... More
LT KIOSK 25 KVA

1

8878

8878.41

... More
SUNDRIES @ 5%( Item No-107 to 131)

1

22392

22392.16

... More
Escallaction Charge 5%( Item No-107 to 132)

1

23511

23511.77

... More
Survey HVOH

0.43

1187

2761

... More
GIS survey

9

279

31

... More
Erection of single Pcc Pole 9 Mtr without fittings

5

11405

2281

... More
Erection of Double Pcc Pole 9 Mtr with fittings

2

18876

9438

... More
Erection of Sub Stn by Pcc Pole 9 Mtr with fittings

1

13169

13169

... More
Erection of 50 sqmm ACSR- 3 wire

0.43

3564

8289

... More
Drawal of pvc cable 50 sq mm 4 cr (rate same as ACSR 30 sq mm 4 cond)

0.04

388

8821

... More
Erection of 25 KVA DTR with Fittings

1

1925

1925

... More
Fixing of 11 KV Pin Insulator

33

2079

63

... More
Fixing of 11 KV Disc Insulator

18

1170

65

... More
Fixing of LT Shackle Insulator

2

104

52

... More
HT Stay set Complete with all fittings (1830 x20 mm)

14

8974

641

... More
Earthing Complete

13

4069

313

... More
earthing of la & other accessories

1

1811

1811

... More
Fixing of Caution Board

1

24

24

... More
Fixing of 11 KV TPGO Isolator

1

1193

1193

... More
Fixing of 11 KV LA

1

339

339

... More
Fixing of Kiosk & Main switch & PVC Cable Conn.- Single Switch

1

2238

2238

... More
Fixing of Solid TEE OFF Bracket- Single pole

1

1510

1510

... More
DTR neutral point earthing

1

3825

3825

... More
Sup @ 10% of Mat+ Lab( Item No-107 to 153)

1

57187

57187.68

... More
Cess @ 1% of Mat+Lab+Sup( Item No-107 to 154)

1

6290

6290.64

... More
GST @ 18% of Lab( Item No-134 to 153)

1

14063

14063.33

... More
Meter Security deposit

1

18461

18461



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.