Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Water Resources Development Directorate - WRDD Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date12 Feb 2025
Closing Soon26 Feb 2025
Tender Amount₹ 14,65,984 
Notes
Download

Costs

Summary

Maintenance Of Wta Allied Works Of Shyamnagar Mdtw M_20 District Nadia, Block Tehatta_i, Under Tehatta A_i Sub_division Under Krishnagar_i A_i Division Under_ Core Sector _2024_25 Programme.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

26.32

327

8606.64

... More
Brick work with 1st class bricks in cement mortar (1:6) a) In foundation and plinth

4.86

4952

24066.72

... More
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.

15

679

10185

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. a) Pakur Variety (for 50 Km distance)

1.97

5626

11083.42

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar (c) 15 mm thick plaster

179.52

144

25850.88

... More
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.

179.52

34

6103.68

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns,lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.

45.91

330

15150.3

... More
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety (for 35 Km distance)

2.91

6171

17960.2

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel II. Other than SAIL/ TATA/RINL

0.25

54375

13702.64

... More
Earth work in excavation of field trenches as per design section and alignment for laying of pipe lines (PVC, RCC, ACP etc.) upto a depth of 1500 mm all sorts of soils including removing, spreading or stacking extra earth as directed. The item includes necessary trimming of sides trenches, levelling, dressing and ramming the bottom as required complete

482.67

99

47789.16

... More
Earth work in filling in trenches after laying pipe lines (PVC, RCC, ACP etc.) with good earth obtained from excavation of field trenches in layers not exceeding 225 mm, including watering and ramming etc. layer by layer complete. (Payment will be made on the basis of measurement of finished .quantity of work.)

482.67

66

31861.05

... More
Laying of P.V.C. pipes of different diameters within field trenches in curve / straight line using P.V.C. fittings, viz. Bend, Tee, Reducer etc. and making leak proof joints with couplers after roughening the surface with wire brush and emery paper and applying solvent cement (The rate is inclusive of transport of pipes, fittings and solvent cement to be supplied by Deptt.) all complete as per direction of Engineer-in-Charge. (iv) 140 mm. dia. PVC. pipe

180

10

1825.2

... More
Labour charge for replacement of different PVC. Accessories in different portion of PVC. Pipeline of HDTW 1 MDTW 1 RLI including taking out of the existing damage accessories, and excluding the supplying the new accessories of 4 Kg.lcm2 capacity and as per I.S. specification at site and fitting,fixing the same by joining with solvent cement (cost inclusive) after roughening up the surface with wire brush, emery papers etc., to make the joint leak proof all complete as per direction of Engineer-in-Charge. (i) 200 mm X160 mm. P.V.C. Reducer

2

80

160.3

... More
Labour charge for replacement of different PVC. Accessories in different portion of PVC. Pipeline of HDTW 1 MDTW 1 RLI including taking out of the existing damage accessories, and excluding the supplying the new accessories of 4 Kg.lcm2 capacity and as per I.S. specification at site and fitting,fixing the same by joining with solvent cement (cost inclusive) after roughening up the surface with wire brush, emery papers etc., to make the joint leak proof all complete as per direction of Engineer-in-Charge. (ii)160 mm X140mm. P.V.C. Reducer

2

80

160.3

... More
Labour charge for replacement of different PVC. Accessories in different portion of PVC. Pipeline of HDTW 1 MDTW 1 RLI including taking out of the existing damage accessories, and excluding the supplying the new accessories of 4 Kg.lcm2 capacity and as per I.S. specification at site and fitting,fixing the same by joining with solvent cement (cost inclusive) after roughening up the surface with wire brush, emery papers etc., to make the joint leak proof all complete as per direction of Engineer-in-Charge. (v) 140 mm X 140 mm X 200 mm. P.V.C.Tee

2

119

239.5

... More
Labour charge for replacement of different PVC. Accessories in different portion of PVC. Pipeline of HDTW 1 MDTW 1 RLI including taking out of the existing damage accessories, and excluding the supplying the new accessories of 4 Kg.lcm2 capacity and as per I.S. specification at site and fitting,fixing the same by joining with solvent cement (cost inclusive) after roughening up the surface with wire brush, emery papers etc., to make the joint leak proof all complete as per direction of Engineer-in-Charge.(viii) 200 mm X 200 mm X 200 mm. P.V.C.Tee

1

119

119.75

... More
Labour charge for replacement of different PVC. Accessories in different portion of PVC. Pipeline of HDTW 1 MDTW 1 RLI including taking out of the existing damage accessories, and excluding the supplying the new accessories of 4 Kg.lcm2 capacity and as per I.S. specification at site and fitting,fixing the same by joining with solvent cement (cost inclusive) after roughening up the surface with wire brush, emery papers etc., to make the joint leak proof all complete as per direction of Engineer-in-Charge. (ix) 140 mm. dia. 90°/60° & 45° long bend

7

99

699.65

... More
Labour charge for replacement of different PVC. Accessories in different portion of PVC. Pipeline of HDTW 1 MDTW 1 RLI including taking out of the existing damage accessories, and excluding the supplying the new accessories of 4 Kg.lcm2 capacity and as per I.S. specification at site and fitting,fixing the same by joining with solvent cement (cost inclusive) after roughening up the surface with wire brush, emery papers etc., to make the joint leak proof all complete as per direction of Engineer-in-Charge. (x) 200 mm. dia 90°/ 60°/ 45° long bend

1

99

99.95

... More
Labour charge for replacement of different PVC. Accessories in different portion of PVC. Pipeline of HDTW 1 MDTW 1 RLI including taking out of the existing damage accessories, and excluding the supplying the new accessories of 4 Kg.lcm2 capacity and as per I.S. specification at site and fitting,fixing the same by joining with solvent cement (cost inclusive) after roughening up the surface with wire brush, emery papers etc., to make the joint leak proof all complete as per direction of Engineer-in-Charge. (xiii)160 mm. dia.flanged tail piece fitted with special bend

3

130

390.39

... More
Labour charge for replacement of different PVC. Accessories in different portion of PVC. Pipeline of HDTW 1 MDTW 1 RLI including taking out of the existing damage accessories, and excluding the supplying the new accessories of 4 Kg.lcm2 capacity and as per I.S. specification at site and fitting,fixing the same by joining with solvent cement (cost inclusive) after roughening up the surface with wire brush, emery papers etc., to make the joint leak proof all complete as per direction of Engineer-in-Charge.(xiv) 160 mm. dia. flanged tail piece fitted with Alfa-Alfa valve

8

130

1041.04

... More
Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.w. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of Engineer-in-Charge.(i)(a) 150 mm. dia. ERW pipe.

245

134

33035.8

... More
Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.w. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of Engineer-in-Charge (v) 150 mm. dia. ERW pipe 90° return bend, both end flanged

1

269

269.68

... More
Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.w. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of Engineer-in-Charge (xii) 150 mm. dia. special bend, both ends flanged.

3

81

243.27

... More
Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.w. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of Engineer-in-Charge xxviii) 150mm. dia. C.I. sluice valve.

4

54

218.76

... More
Carriage of Departmental materials from the Deparmental Store to the work site and return back the damaged/replaced and unused materials to store including loading & unloading complete at both sides by Tempo,VanRikshaw/Mini Truck etc. upto 25 Km distance in one way. i) For Delivery pipe, Surge Tank, Bend, Valve etc.

1

905

905.23

... More
Repair of puncture/holes of any size in existing PVC. Pipeline of HDTW/MDTW/RLI by placing half round PVC. Pipe section of required size to cover the holesl puncture having adequate bearing on all sides and joining the half round section with solvent cement after roughening the surface with wire brush, emery paper to make the joint leak proof as per direction of Engineer-in Charge (cost inclusive of supplying solvent cement at site and transportation of required length of PVC.Pipe to be issued departmentlly, for cutting half round section, from Sub-Divisional Stores to site) (ii) 200 mm dia Pipe line

12

83

1007.04

... More
Repair of puncture/holes of any size in existing PVC. Pipeline of HDTW/MDTW/RLI by placing half round PVC. Pipe section of required size to cover the holesl puncture having adequate bearing on all sides and joining the half round section with solvent cement after roughening the surface with wire brush, emery paper to make the joint leak proof as per direction of Engineer-in Charge (cost inclusive of supplying solvent cement at site and transportation of required length of PVC.Pipe to be issued departmentlly, for cutting half round section, from Sub-Divisional Stores to site) (iii) 140 mm dia pipe line

25

59

1485.25

... More
Labour charge for replacement of damage PVC. Pipe of any length in the Pipe line of HDTW 1 MDTW 1 RLI with new piece/s of pipe after taking out the damage pipe/s from the existing pipe line by cutting with hacksaw and joining the new pipe/s with the existing pipe line using necessary couplers after roughening up surface with wire brush, emery paper and applying the solvent cement (cost inclusive) to make the joint leakproof (pipe & couplers to be supplied departmentally) including transporting departmentally issued pipe/s, couplers etc. from Sub-Divisional Store to the Site all complete as per direction of Engineer-in-Charge. (ii) 200 mm dia Pipe line

10

249

2498.8

... More
Labour charge for replacement of damage PVC. Pipe of any length in the Pipe line of HDTW 1 MDTW 1 RLI with new piece/s of pipe after taking out the damage pipe/s from the existing pipe line by cutting with hacksaw and joining the new pipe/s with the existing pipe line using necessary couplers after roughening up surface with wire brush, emery paper and applying the solvent cement (cost inclusive) to make the joint leakproof (pipe & couplers to be supplied departmentally) including transporting departmentally issued pipe/s, couplers etc. from Sub-Divisional Store to the Site all complete as per direction of Engineer-in-Charge. (iii) 140 mm dia pipe line

20

199

3998.2

... More
Labour charges for fitting,fixing 160mm. dia. P.V.C .riser pipe with 150mm. dia. M.S. 90° bend by using P.V.C. tail piece.

15

112

1683.15

... More
a) Removing of Chokage due to sludge, mud, sand or any other forign materials deposition from the underground 110/ 140/200/315 mm dia. PVC. Pipe Line with split bamboo,wire brush, coir rope etc. along with suitable cleaning agent as necessary as per direction of E.!'C. (This item includes the cost of earth cutting & back filling of trenches and required materials for chokage cleaning but excluding the cost for replacement & jointing of PVC pipes). ii) For 200/140/11 0 mm dia PVC Pipe (ii) 200 mm dia Pipe line

210

31

6535.2

... More
a) Removing of Chokage due to sludge, mud, sand or any other forign materials deposition from the underground 110/ 140/200/315 mm dia. PVC. Pipe Line with split bamboo,wire brush, coir rope etc. along with suitable cleaning agent as necessary as per direction of E.!'C. (This item includes the cost of earth cutting & back filling of trenches and required materials for chokage cleaning but excluding the cost for replacement & jointing of PVC pipes). ii) For 200/140/11 0 mm dia PVC Pipe (iii) 140 mm dia pipe line

510

31

15871.2

... More
Labour charges for fitting. fixing M.S. Special bend with 160 mm X 200 mm. dia. P.V.C. reducer with the help of flanged tail-piece by joining P.V.C. end of tail-piece and 160 mm. end of reducer with coupler and flanged end of tailpiece and special bend with rubber insertion, nuts and bolts complete.

3

112

336.63

... More
For Water transmission Arrangement of Tube well 4% extra over the schedule rates, save & except for earth work in excavation & filling works, will be allowed for extra carriage by cart / boat / head load besides initial transport by truck etc. [Excluding Sl.No. 1.01, 1.02, 1.12, 1.13 & 1.27)

1

6138

6138.86

... More
GST @ 18 %

1

52615

52615.64

... More
Add.- L. W. Cess @ 1.0 %

1

3449

3449.25

... More
Supply of Materials

-

-

-

... More
C.I. Alfa-Alfa Valve as per Drawing (Annexure-E )with MS Spindle and weight of the bottom disc to be fitted with rubber washer which will be fitted tightly at the closing of Alfa-Alfa Valve. There should arrangement of squre type key holder made of MS complete including two course of painting over a coat of priming. Approximate weight 20 Kg excluding Key. (i) 150 mm Dia.(Type-C)

8

4435

35480

... More
ISI marked Sluice Valve pressure designation PN 1.6 with hand wheel for water works purpose, CI flangeed type conforming to IS 14846/2000 with Amendment No 1 & 2. Components/parts of Sluice Valves shall be manufactured from basic materials given in table 1 of IS 14846/2000 with Amdt. 1 & 2. The valves shall be tested for (closed end test) against Hydrostatic test requirement. (i) 150 mm dia

4

9950

39800

... More
150 mm dia Rubber Insertion 5 mm thick with proper reinforcement 2 ply conforming to IS 638/79 with latest amendments duly ISI marked suitable for MS flange as per IS 6392/71 with standard drilled holes.(For Sluice Valve)

36

110

3960

... More
Supply of 200 mm dia NB 6.4 mm nominal wall thickness, M.S.E.R.W. Pipe duly ISI certification marked, both ends Plain Grade Fe-410 conforming to IS:4270/2001 (Reaffirmed Nov. 2006) with latest amendments No. 1 ( (Each pipe shall be approx. 6 metre In length )

252

3214

809928

... More
90 degree G.I Bend (both end flanged)J-ISImarked-IS 1239, Galv- IS4736 (a) 150 mm dia

1

8175

8175

... More
Supply of 100 mm dia Lay - Flat Hose ( Non - ISI)

350

170

59500

... More
Supply of U.P.V.C. Pipes (Class-I/II) IS:4985/2000 certification marked with latest amendments, Ivory grey coloured, both end plain, along with one matching coupler/socket (Class-II) duly IS:10124/1988 certification marked and required solvent cement duly IS:14182/1994 certification marked for each pipe. Length of each straight pipe 6 mts. tolerance +10 mm (nominal wall thickness of pipe 2.5 to 3.0 mm) 200 mm dia. PVC pipe with coupler, Class-I

60

605

36300

... More
Supply of U.P.V.C. Pipes (Class-I/II) IS:4985/2000 certification marked with latest amendments, Ivory grey coloured, both end plain, along with one matching coupler/socket (Class-II) duly IS:10124/1988 certification marked and required solvent cement duly IS:14182/1994 certification marked for each pipe. Length of each straight pipe 6 mts. tolerance +10 mm (nominal wall thickness of pipe 2.5 to 3.0 mm) 140 mm dia. PVC pipe with coupler, Class-I

180

293

52740

... More
Supply of U.P.V.C. Pipes (Class-I/II) IS:4985/2000 certification marked with latest amendments, Ivory grey coloured, both end plain, along with one matching coupler/socket (Class-II) duly IS:10124/1988 certification marked and required solvent cement duly IS:14182/1994 certification marked for each pipe. Length of each straight pipe 6 mts. tolerance +10 mm (nominal wall thickness of pipe 2.5 to 3.0 mm) 160 mm dia. PVC pipe with coupler, Class-II

15

631

9465

... More
Supply of UPVC Flanged Tail piece with metallic flange (Class-II) IS:10124(Part-6)/1988 certification marked with latest amendments FTP incl. 160 mm dia. M.S. flange with 8 nos. holes (12 mm thick)

15

670

10050

... More
Supply of UPVC Bend (class -II) IS:10124(Part-9)/1988 certification marked with latest amendments 200 mm dia. 60 ° / 90 ° PVC bend

4

1776

7104

... More
Supply of UPVC Bend (class -II) IS:10124(Part-9)/1988 certification marked with latest amendments 140 mm dia. 60 ° / 90 ° PVC bend

6

647

3882

... More
Supply of Straight Reducer (class -II) IS:10124 (Part-3)/1988 certification marked with latest amendment 200 mm X140 mm P.V.C. Reducer (comprising of two straight reducer of 200 X 160 & 160 X 140 mm duly joined nominal size 200 x 140mm

2

994

1988

... More
Supply of Straight Reducer (class -II) IS:10124 (Part-3)/1988 certification marked with latest amendment 200 mm X 160 mm P.V.C. Reducer

2

757

1514

... More
Supply of Straight Reducer (class -II) IS:10124 (Part-3)/1988 certification marked with latest amendment 160 mm X 140mm P.V.C. Reducer

4

328

1312

... More
Supply of UPVC Tee ( class-II) IS:10124(Part-5)/1988 certification marked with latest amendments 200 mm X 200 mm X 200 mm. P.V.C.Tee

1

1482

1482

... More
Supply of UPVC Tee ( class-II) IS:10124(Part-5)/1988 certification marked with latest amendments 140 mm X 140 mm X 140 mm. P.V.C.Tee

2

712

1424

... More
Supply of UPVC Cap (Class-III) IS:10124(part-4)/1988 certification marked with latest amendments 140 mm dia PVC end Cap

1

330

330

... More
Supply of UPVC Cap (Class-III) IS:10124(part-4)/1988 certification marked with latest amendments 200 mm dia PVC End Cap

1

755

755

... More
Supply of UPVC Socket / coupler (class-II) IS:10124(Part-1 & 2)/1988 certification marked with latest amendments 200 mm dia PVC Extra Coupler

20

301

6020

... More
Supply of UPVC Socket / coupler (class-II) IS:10124(Part-1 & 2)/1988 certification marked with latest amendments 140 mm dia PVC Extra Coupler

30

130

3900

... More
Supply of Extra Solvent cement (Class - Heavy Bond) IS:14182/1994 certification marked with latest amendments)

5

425

2125

... More
150 mm dia 1.0 mtr long M.S. Short piece made of 150 mm dia ERW pipes conforming to IS 1239(part-1)/2004,

8

2547

20376



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.