Water Resources Development Directorate Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Water Resources Development Directorate - WRDD Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date8 Jul 2024
Closing Date16 Jul 2024
Tender Amount₹ 1,65,292
Costs
EMD
₹ 3,500Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Wridd/ Ee (a-i) /malda/ Enit- 01 /2024-25 (sl. No. 1 To 11)
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WRDD_708070_3Bid Award Id
ViewTender No
WRIDD/ EE (A-I) /Malda/ eNIT- 01 /2024-25Tender Authority
Water Resources Development Directorate ViewPurchaser Address
-Website
http://http://www.wbwridd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.. (P.W.D schedule page No.10 & item No.2) In ground floor including roof.
0.07
65
939
Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed..
31.95
607
19
125 mm thick brick work with 1st class bricks in cement mortar (4:1) in Ground Floor.
9
6014
668.33
Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (A) [Pakur Variety] (a) 1:3:6 proportion.
0.86
3731
4339
Artificial stone in floor, dado, staircase etc. with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners and including application of cement slurry before flooring works, using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm thick topping (High polishing grinding on this item is not permited) with ordinary cement. (iii) 25 mm thick
12.71
3085
242.8
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.
2.09
10993
5267.53
Plaster (to wall, floor, ceiling etc.) with sand and cement morter including rounding off or chamfering corner as directed and raking out joints or roughening of concrete surface, including throating, nosing and drip course where necessary (gorund floor) (ii) 15 mm. thick plaster. (Outside wall of Room, Steps etc.)
75.1
11575
154.14
Neat cement punning about 1.5 mm thick in wall, dado, window sills floors, drains etc.
60.1
1966
32.72
Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification (Ground floor) (a) Two coats (on new works only). (i) Other than yellow, pink.
93.26
4569
49
Priming one coat on wooden surface with synthetic enamel/ oil bound primer of approved quality including smoothening surface by sand papering etc. [P.W.D Schedule page no.343, item no 7(b)].Wooden surface
4.26
161
38
Painting with best quality synthetic enamel paint of approved make and brand including smoothenig surface by sand papering etc. including using of approved putty etc. on the surface if necessary.
(b) On Wooden surface. With super gloss (hi-gloss). Two coat (with any shade except white)
4.26
345
81
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
10.8
3477
322
Additional cost of carriage of constructional materials for construction of one D.T.W. pump house @3% of total except for earth work in excavation and filling
50707.99
1521
0.03
PIPE LINE MAINTENANCE: b) Removing of Chokage due to sludge, mud, sand or any other forign materials deposition from the underground 450 / 300 /225/ 150 mm dia. R.C.C. Pipe Line with split bamboo, wire brush, coir rope etc. along with suitable cleaning agent as necessary as per direction of E.!.C. (This item includes cost of earth cutting & back filling of trenches and required materials for cleaning but excluding the cost for taking out 1 full length of RCC Pipe by dismantling of 2 nos. of Collars & refittingthe RCC pipe with new two nos. collar).
450/300/225/150 mm dia RCC pipe
500
19330
38.66
Repairing of leakages in collar joints of R.C.C. Pipe line by opening the joints fully by chipping out the old morter, cleaning the pipe recesses and collar properly, and thereafter positioning and levelling the pipes and collar, filling the annual spaces of joints with jute braiding dipped in cement slurry and grouting with (1:2) cement morter mixed with approved quality water proofing compound (5% by wt. of cement) and curing all complete as per direction of Engineer-in-Charge.
450/300/225/150 mm dia RCC pipe
20
1357
67.89
Taking out the damaged R.C.C. Pipe and two collars by dismantling two joints carefully, carrying and stacking the same near the pump house, carrying new pipe and collars from the field stack, lowering the same within the trench, properly positioning and levelling on bricks laid flat, between collar and the pipe joints with jute braiding dipped in cement slurry, grouting with cement and sand mortar (1:2) mixed with approved quality water proofing compound (5% by weight of cement) and curing all complete as per direction of Engineer-inCharge.
225 mm dia RCC pipe
25
2899
115.98
Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.w. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of Engineer-in-Charge.
xxviii) 150 mm dia C.I. Sluice valve
3
163
54.49
1)a 150 mm dia flange pipe
30
4045
134.84
v) 150 mm. dia. ERW pipe 90° return bend, both end flanged including supplying and fixing wooden block
1
269
269.68
(xii) 150 mm. dia. special bend, both ends flanged.
3
243
81.09
Labour charges for fitting, fixing150 mm. Dia. Alfa-Alfa valve with 160mm. dia. P.V.C. riser pipe with the help of flanged P.V.C. tail-piece by joining the P.V.C. End of Tail-piece and riser pipe with coupler and flanged end of Tail-piece and Alfa-Alfa valve with rubber insertion, nuts and bolts etc. complete.
6
673
112.21
Labour charges for fitting. fixing M.S. Special bend with 160 mm X 200 mm. dia. P.V.C. reducer with the help of flanged tail-piece by joining P.V.C. end of tail-piece and 160 mm. end of reducer with coupler and flanged end of tailpiece and special bend with rubber insertion, nuts and bolts complete
3
336
112.21
Installation / Erection of SurgeTank / Shore manifold (to be supplied from Deptt. free of cost) over a rigid base of ordinary cement concrete (1:2:4) with graded stone chips (20mm. nominal size) of pakur varity of 1250 mm X 1250 X 150 mm. over a single layer of brick flat soling and embedding the legs of the surge tank/shore manifold within the concrete base including cost of allmaterials and labour and as per direction of Engineer-in-Charge.
1
2263
2263.08
a) Supplying and filling up of the annular space between the Well Pipe and the bore hole by coarse sand including watering as necessary as per direction of the Engineer-in-ChargeExisting abandent Bore Hole
9.61
6905
718.53
(i) Labour for loading R. C. Spun pipes (NP-2) into trucks, carts etc. at lifting point & unloading the materials at destination point & stacking the same in stackyard or go-down as per direction including carriage within a lead of 100 m (or part thereof) at each end ( 2.50 m length of each pipe)
62.5
1414
22.63
(i) Carriage of R.C. pipes & collars over pucca road upto 5 Km. distance (for NP-2)(a) Pipe, Collars of 225 mm. dia.
62.5
441
7.07
(i) Extra rate for carriage of R.C. pipes & collars over pucca road beyond 5 Km. upto any distance (for NP-2).225 mm dia RC pipe with collar. a)) 25.00 KM
62.5
1105
70.72
INTERNAL WIRING: Fixing only Sheet Steel Main Switch(Rewirwable type)/ Change over on Flat Iron Frame/Angle Iron Frame on wall ( including all materials except equipment ) i) For 100 Amp. Main Switch
1
215
215
Fixing only starters (for motor control) on flat angle iron frame on wall. b) For star delta starter 22.5 HP to 25 HP.
1
215
215
Fixing only Voltmeter/Ammeter/Energy meter with screws & other fixing materials incl. making necessary holes and connections.
a) Ammmeter
1
57
57
Supplying and fixing 240 volt, 15/16 Amps. DP. Sheet Steel Main Switch on flat iron frame on wall. (Havells make.)
1
576
576
Earthing with 65 mm. dia G.I. pipe ( TATA medium) into 3.0 mts . Long and 1 no 50mmx6mm galvanized ( hot deep) steel strip ( 4 metre long) , 20mm dia x125mm long galvized bolt , double nuts double washers including finishing both ends by making holes etc. and S& F 65 mm dia G.I. pipe ( ISI medium) protection ( 3mts long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 mts.
(a) For soft soil
1
3868
3868
Supplying and fixing earth bushbar of galvanized (Hot Dip) M.S. Flat 25 mm × 6 mm on wall having clearance of 6 mm. from wall including providing drilled holes on the busbar complete with G.I. bolts, nuts, washers etc. , spacing insulators as required .
0.3
46
156
Connecting the equipments to earth busbar including supplying and fixing G.I. (Hot Deep) Wire of size as below on wall/floor with stapples burried inside wall and floor as required and making connection to equipments with bolts, nuts, washers, cable, lugs etc. as required and mending good damages. ( a) 6 SWG
5
45
9
Finishing the end of XLPE/P.V.C.armoured cables by crimping method including supplying & fixing soldering socket,(dowels make), tapes , anti corrosive pastes & joining materials.
(a) 3½ core 25 Sqmm.
2
220
110
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light/fan/call bell point with piano key type switch (Anchor make) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works. [PVC casing-capping and Switch board both on surface]
Outside room - 1 light point
Pump Room - 1 light point
Varandah - 1 light point
(a) average run 6 mts.
3
1950
650
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.
4
152
38
Supplying & Fixing bulk head light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 8watt CFL / 100 watts GLS lamp complete set.
1
579
579
Add extra charge @ 5.0 % for Malda District as per preface item A - iv of Electrical wiring volume - I of 2017.
0.05
396
7923.8
Withdrawal of electro motor submersible pumping set of following capacities from within the tubewell housing pipe of the following length by using all necessary requisites tools and plants and carefully as per direction of Engineer-in-Charge and stacking the same properly at site within the tubewell
premises complete. (a) 100/150/200 cubic metre per hour capacity electro motor pumping set.
I(ii) Length of pump assembly of any length exceeding 18 metre length from existing Tube Well
1
1045
1045.73
Installation of submersible electro motor pumping set of following capacities by using necessary requisite, tools and plants by lowering the same within the tubewell housing pipe upto the following depth as per direction by fitting, fixing column pipes and other accessories, fixtures with necessary nuts, bolts and washers and suspending the entire assembly of pump set vertically by fixing the same supported by M.S. clamps over the top of housing pipe, binding the motor cable with each column pipes and drawing cable upto pump controller/starter point including opening out of the top cap of housing pipe of the tubewell and testing of motor both in loading as well as in unloaded condition before and after installation of the same. (The rate is inclusive of hiring charges of tools & plants.)
(a) 100/150/200 cubic metre her hour capacity electro motor pumping set.
(ii) Length of pump assembly of any length exceeding 18 metre length.
1
1510
1510.61
Meter loop connection with 1.1 K.v. Gr. 3% core 14 core 10 Sqmm to 50 Sq mm. p.v.C.! XLPE insulated & sheathed and armoured Aluminium/Copper Cable from Meter toincomming TPN Main Switch 1 Terminal.(Brand: Gloster/Havells/Finolex)
For HDTW/MDTW/MINI RLI Scheme
i) 25 Sqmm 3% Core Copper Cable
2
3119
1559.64
Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.w. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of Engineer-in-Charge.[WRDD Schedule page no.14, item no 2(i)] i) 150 MM DIA ERW/MS PIPE
18
2427
134.84
ii) 150 mm Dia Sluice valve
3
163
54.49
iii) 150 mm. dia. ERW pipe 90° return bend, both end flanged including supplying and fixing wooden block
4
1078
269.68
Carriage of Departmental materials from the Deparmental Store to the work site and return back the damaged/replaced and unused materials to store including loading & unloading complete at both sides by TempoNan Rikshaw/Mini Truck etc. upto 25 Km distance in one way.
iii) Pump-Motor Set (this item is applicable only for burnt/damaged Pump-MotorSet
1
1037
1037.25
i) For Delivery pipe, Surge Tank, Bend, Valve etc.
1
905
905.23
Charge for jointing water proof cable with required water proof insulation and proper jointing compound including supplying other related materials complete.
6
594
99.01
Electric welding charges upto 8mm MS plate , MS channel etc and others member of the barge including hiring charges of all tools and plants . Welding of MS structural work with gas/electric (b) Continous welding
10
90
9
Add G.S.T. @18% (For Sl No 01 to 52)
0.18
24964
138690.83
Add CESS @ 1% (For Sl No 01 to 53)
0.01
1636
163655.18
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements