Uttar Banga Krishi Viswavidyalaya Tender

... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Uttar Banga Krishi Viswavidyalaya - UBKV Tender

Works
Furnitures and Fixtures
Eprocure
Opening Date18 Oct 2023
Closing Date6 Nov 2023
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and placing of 3 storage units (1D + 2S) for Laboratory. The suspended under-bench welded units should be supported on heavy-duty steel frames fully carrying the load of worktops. Shelf height should be adjustable with an increment of 1inch / 25mm. The storage cabinets should have the provision for horizontal sliding to make available leg space as per the need. It should have the provision for relocation anywhere easily. Cabinet should be of square non-sharp edge construction. Doors should be assembled with SS-304 hinge assembly. . Drawer tray should be of single piece construction. Drawer should be well supported on LH and RH ball slide suspension system. Steel door and drawer front should be of double wall construction with sound dampening material filled inside. Doors should be easily removable, and hinges should be easily replaceable. Knee space panel should be in 22-gauge construction. The dimensions of the cabinets should be W = 450/600 (as per the layout) D = 530mm, H = 635/485 mm. The configurations should be 1 Shutter/ 2 Shutters and 1 Drawer as per the layout. The entire material construction for the storage units should be MSCRCA: IS – 513 (1994). Thickness of LH/RH side panels, shutter front, Bottom panel, Top front, Drawer separator, shelf, Alignment channel should be of 1.2mm thk. Removable Back panel, Shutter cover, Fr. Rack strip, Top cover panel should be of 0.8mmthk. The finish of the welded cabinets should be powder coated pure epoxy of thickness 40-50 microns. Handles should be Anodized Aluminium Recessed-Type, of CTC: 160.0mm. Units should have a locking facility with 180° and 10 lever cam lock mechanism. The hinges should be Knuckle-butt type SS Hinge. The screws should be SS304. Shutter should be of twin-type construction with sound dampening effect using profeel. Shutter cover should be equipped with Bump on for sound dampening. Ball Slide for drawer units should be 500mm length.

1

-

-

... More
Supply and placing of Laboratory Tables as per the approved Layout. Wall Bench of overall size of 4580 mm (W) x 770mm (D) x 900mm (Ht.). All C-Frames assemblies should be manufactured from standard hollow metal sections; confirming to I.S. Code 7138:1973 (Indian Standard specification for steel tubes for furniture) and all sheet metal components should be of CRCA confirming to IS Code 513:1994. The suspended under-bench welded units should be supported on heavy-duty steel frames fully carrying the load of worktops. Its superior strength combined with aesthetically appealing end caps shall give maximum flexibility and modularity while making a layout. C-frame should be constructed from a rectangular pipe with a cross section of 60mm x 30mm and should be 2 mm thick and should be without a vertical front leg to give a clean look. This shall provide more knee space or leg space and would facilitate uninterrupted lateral movement of the under-bench units within the bench run. The C-frame legs should be supplied with adjustable feet (tolerance from -5mm to +20mm) to correct the unevenness of flooring. The tubular enclosed type of construction shall discourage dust accumulation and unwanted development of bacteria & fungus. Drainage gradient should be well adjusted throughout the length of table and should have horizontal supports for drainage systems. The structure should have a removable back panel to provide access for maintenance throughout the length of table. The C-frame shall also have skirting at back bottom side. It should be suitable for sitting and standing nominal heights of 750mm & 900mm respectively depending on the layout and the requirement of the laboratory. The table depth should be 920 mm. The length of the table should be as per the approved layout (or BOQ). The horizontal members which should connect the c-frames should be made from rectangular pipes of 2mm thickness. Cross-sectional dimensions of the pipe should be 60 x 30 x 2 mm. They should be made of CRCA MS and coated with pure epoxy powder. They should be available in various widths of 600, 750, 900, 1050, 1200, 1350, 1500, 1650, and 1800, depending on the layout of the laboratory furniture. The cover panels should cover the service lines that runs behind for the wall side units and through the middle for the island units. These should be easily removable (unclipped), and the service line be accessed for maintenance. They should be made of CRCA MS with pure epoxy powder coating and are of 1mm thickness. The vertical upright should form the backbone for internal distribution of GDS, electrical supply systems shelves and top units and should be constructed from 16-gauge CRCA formed steel panels with removable covers. Uprights should be supplied with adjustable feet from -5mm to +20mm. The ends and intermediate vertical supports should be 2mm thick aluminum extrusion with MS brackets of 2 mm thick. Metal platform should be put-on over these shelves for taking care of bottle marks/corrosion. Suspended welded cabinet body should be of flush face construction with intersection of vertical and horizontal members like LH and RH side panel along with front horizontal channel, back panel and bottom panel. Removable back panel should be provided to easily access the service lines running behind the cabinet benches. Intermediate horizontal channels should be provided between door and drawer. Shelf should be eight bend panel with 20mm height. The worktop should be 19mm (+/- 2mm) thick Jet-Black Granite worktop. The exposed edges of the worktop should be chamfered and smoothened. The bottom of the worktop should be polished and there should be a V-groove throughout the length of the exposed edges to protect the cabinets from meeting the spillages. The overhang on the storage cabinet is 25 mm at the front side and 30 mm at the sides. The backing material used is a neoprene mat of 6 mm thickness.

1

-

-

... More
Supply and placing of 3 storage units (1D + 2S) for Laboratory. The suspended under-bench welded units should be supported on heavy-duty steel frames fully carrying the load of worktops. Shelf height should be adjustable with an increment of 1inch / 25mm. The storage cabinets should have the provision for horizontal sliding to make available leg space as per the need. It should have the provision for relocation anywhere easily. Cabinet should be of square non-sharp edge construction. Doors should be assembled with SS-304 hinge assembly. . Drawer tray should be of single piece construction. Drawer should be well supported on LH and RH ball slide suspension system. Steel door and drawer front should be of double wall construction with sound dampening material filled inside. Doors should be easily removable, and hinges should be easily replaceable. Knee space panel should be in 22-gauge construction. The dimensions of the cabinets should be W = 450/600 (as per the layout) D = 530mm, H = 635/485 mm. The configurations should be 1 Shutter/ 2 Shutters and 1 Drawer as per the layout. The entire material construction for the storage units should be MSCRCA: IS – 513 (1994). Thickness of LH/RH side panels, shutter front, Bottom panel, Top front, Drawer separator, shelf, Alignment channel should be of 1.2mm thk. Removable Back panel, Shutter cover, Fr. Rack strip, Top cover panel should be of 0.8mmthk. The finish of the welded cabinets should be powder coated pure epoxy of thickness 40-50 microns. Handles should be Anodized Aluminium Recessed-Type, of CTC: 160.0mm. Units should have a locking facility with 180° and 10 lever cam lock mechanism. The hinges should be Knuckle-butt type SS Hinge. The screws should be SS304. Shutter should be of twin-type construction with sound dampening effect using profeel. Shutter cover should be equipped with Bump on for sound dampening. Ball Slide for drawer units should be 500mm length.

1

-

-

... More
Supply and placing of Over Head Units as per the approved Layout. Over Head Units of overall size of 600mm (W) x 340mm (D) x 635mm (Ht.). The construction should be the same as the under-bench cabinets. The height of these cabinets should be around 635mm while the depth should be around 340mm. The shutters should be available in two options: Metal shutters and Metal frame with inserted glass. There should be one height-adjustable shelf inside each cabinet. Other construction should be similar to under-bench cabinet

20

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.