Uttar Banga Krishi Viswavidyalaya Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Uttar Banga Krishi Viswavidyalaya - UBKV Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date7 Sep 2022
Closing Date27 Sep 2022
Tender Amount₹ 4,67,542
Costs
EMD
₹ 9,351Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_UBKV_402903_4Bid Award Id
ViewTender No
NIeT-03/2022-23Tender Authority
Uttar Banga Krishi Viswavidyalaya ViewPurchaser Address
-Website
http://https://wbtenders.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
b) 2x 2.5 +1x1.5 Sq mm for Computer and power points,
120
-
78.67
Fixing only single LED tube light fitting suspended 25 -30 cm bellow the ceiling with 2 No 20 mm dia EI condit (14 SWG) supports incl. S&F EI conduit,and complete with all accessories directly on ceiling through U type iron clamp and suitable size of MS fastene and S&F 3x1.5 sq mm flexibale copper wire of 1.5 mt .
4
-
259.02
Extra for suspention additional 2 no 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x1.5 mm flexible wire of 1.10 mt. length.
4
-
259.02
Fixing of 240 volt, 1200 mm sweep ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 3x1.5 sq.mm. flexible copper wire.
3
-
79.89
S & F. 240V, 2 Modular socket type fan regulator (Step type) (Crabtree) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
3
-
468.42
S & F. MS fan clam of two piece type for RC ceiling fabricated from 40 mm x 9 mm MS flat incl. making good damages to building roof with satisfactory finishing and painting.
3
-
292.91
Supplying and fixing 63 amp,8 way double door HTPN MCB DB with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment and painting for AC, SPNDB and Geyser.(Make- Legrand )
1
-
5076.35
Supplying and fixing 415 V 63 A, 4 pole MCB Isolator on din rail of existing DBs and necessary connection.( Legrand)
1
-
1022.77
Supplying and fixing 415 V 32 A, 4 pole MCB Isolator on din rail of existing DBs and necessary connection.( Legrand)
1
-
755.28
S & F. 10-32 amp, 240V SPN MCB, ‘C’ curve on din rail of existing PDB & DB and necy. connection (Legrand). For HTPN MCB DB
24
-
229.97
Supplying and fixing double-door (2+8) SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.(Legrand)
1
-
1787.74
S & F. 240 volt, 40 amp. MCB DP Isolator on din rail of existing DB and necessary connection ( Legrand).
1
-
422.42
S & F. 240 volt, 16 amp. MCB DP Isolator on din rail of existing DB and necessary connection ( Legrand).
1
-
422.42
S & F. 10-32 amp, 240V SP MCB, ‘C’ curve on din rail of existing PDB & DB and necy. connection (Havell’s). For SPN MCB DB.
8
-
229.97
Supply & Fixing 240 V, 6/16 A, 3/5 pin Modular type plug socket (Legrand) with 16A Modular type switch, without plug top on GI Modular type switch board with top cover plate on wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. for power points.
6
-
551.94
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles. 19 mm dia 3 mm thick polythene pipe with 1x14 SWG GI earth continuity wire.
100
-
78.67
Cutting Channel of size (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles.. 25 mm dia 3 mm thick polythene pipe with 1x14 SWG GI earth continuity wire
75
-
95.62
Laying of one No. cable 3.5 core 25 sqmm in underground trench 460mm wide x 760mm average depth, with brick pro tection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed from proposed main panel at proposed seed godown at proposed HTPN MCB DB at proposed implement shed.
25
-
196.08
Laying of following cables after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish.a) 4 core 16 sqmm at an average depth of 75 mm in floor/pavement/wall etc.from HTPN TO 4 pole MCB DB.
25
-
153.72
b) 2 core 16 sqmm at an average depth of 75 mm in floor/pavement/wall etc.from HTPN TO SPN MCB DB.
15
-
153.72
S&F compression type gland complete for following XLPE/PVC armoured cables.3.5 core 25 Sq. mm
2
-
183.98
4 core 16 Sq. mm
2
-
159.77
2 core 16 Sq. mm
2
-
139.19
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.3.5 core 25 Sq. mm
2
-
133.14
4 core 16 Sq. mm
2
-
114.99
2 core 16 Sq. mm
2
-
70.2
3.5 core 95 Sq. mm
4
-
375.22
Earthing with 50 mm dia. ISI medium GI pipe 3.64 mm thick x 3.04 mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 mts. long), 13 mm dia. x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia. GI pipe protection (1 mt. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 mts. below the ground level. 2 nos for existing panel and rest for proposed panel
2
-
1657.02
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachmen. Make- Legrand.a) 2 way for operation of security light. .
1
-
326.8
b) 4 way for operation of security light. .
1
-
382.48
Connecting the equipments to earth busbar including S & F. 8 SWG copper solid wire on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.Earth wire should be connected earth pit to all bushbar and earth bus bar to VTPN, HTPN, SPN MCB DB etc..
2
-
1502.52
Supply of 240 volt, 20 watt single LED tube light fittings (Cat. No – Frame – Crompton ECO – model – DIJB12L-T8-20, Tube – Crompton – Secure - model – LTT8-20 or equivalent Havells, Philips).
4
-
1306.53
Supply of XLPE/ PVC Armoured Aluminium cable (GLOSTER, CRYSTOL, Havells)..1.1 kv grade, 3.5 core ,25 sq mm XLPE/PVC armoured aluminium cable,
25
-
454.5
1.1 kv grade, 4 core ,16 sq mm XLPE/PVC armoured aluminium cable
40
-
371.52
1.1 kv grade, 2 core ,16 sq mm XLPE/PVC armoured aluminium cable.
10
-
276.45
Supply of 230volt, 1200 mm sweep , AC ceiling Fan ( Orient - Summer King, SummerCool, Summer Breeze,)
3
-
3376.56
Fixing of 240 volt 300 mm sweep exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:
6
-
398.22
Supply & Fixing of 300 mm (12") Aluminium louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) etc..
6
-
233.6
Laying of one No. cable 3.5 core 95 sqmm in underground trench 460mm wide x 760mm average depth, with brick pro tection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed from proposed main panel to proposed seed godown at proposed HTPN MCB DB
108
-
208.19
S&F compression type gland complete for following XLPE/PVC armoured cables.3.5 core 95 Sq. mm
4
-
331.65
Supply of XLPE/ PVC Armoured Aluminium cable (GLOSTER, CRYSTOL, Havells)1.1 kv grade, 3.5 core ,95 sq mm XLPE/PVC armoured aluminium cable,
108
-
1315.91
Supply of 230 volt, 300 mm. sweep, 80 Watt, 1420 rpm heavy duty exhaust Fan ( EPC, MARATHON)
6
-
5073.43
Supply of 240 volt, 120 watt LED outdoor type light fittings (Cat no – Crompton – PLUTO NEO – model LFLN-120 CDL/60-M or equivalent Havells, Philips).
3
-
9210.23
MAIN PANEL - Febricating , supplying , installation, testing and commissioning of wall/ floor mounting industrial type L.T. Oanel board made with 40 x40 x6 mm. ms. angle and 40x6 mm. M.S. flat incl. fabricated with 16 swg. M.S. sheet box for accommodation of the following switches incl. making throughout joining between main switches and BBC and inter connection by suitable size of FR-PVC copper wire, fixing M.S. cable gland and socketing the ends with powder coated approved paint over a coat of R.O. primer as per direction of EIC . The panel board comprising with the following switches:- 415 volt , 200 A, 4 bar , copper Bus bar with dist. Charge.with dist. Ch. - 1 set, 415 volt, 200 A, Open execution type main switch S&F HRC fuse (L&T)- with dist. Ch.-1 no, 415 volt,100A, TPN on load Open execution type changeover(L&T) .with dist. Ch.-3 nos, 415 volt,63 A, TPN on load Open execution type changeover(L&T) .with dist. Ch.-1 no, Ammeter & Selector switch (ISI) -1 set, Voltmeter & Selector switch (ISI) -1 set, Pilot lamp with slidin fuse (ISI) -3 set, Danger board ( 20x30 cm.) - gn ( Design of panel board will provide by the Department)- 1 no
1
-
92778.54
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements