Uttar Banga Krishi Viswavidyalaya Tender

... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Uttar Banga Krishi Viswavidyalaya - UBKV Tender

Works
Eprocure
Opening Date17 May 2021
Closing Date7 Jun 2021
Tender Amount₹ 50,19,293 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)

280.87

-

487.9

... More
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

455.09

-

364.25

... More
(II) Cement concrete with 30 mm down graded shingles excluding shuttering. N.B. Variety In ground floor (a) 1:3:6 proportion

34.13

-

3838.16

... More
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(ii ) River Bazree

36.06

-

5437.68

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.(b) River bazree

40.16

-

4602.85

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). (f) 25 mm to 30 mm shuttering without staging in foundation

262.89

-

231.9

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation, basement and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel I. SAIL/ TATA/RINL

5.09

-

69302.27

... More
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete.The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete.i) For roof truss works a) Span up to 12 Mtr

8.6

-

84030.06

... More
Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn)coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work).(i) In Roof:-a) With 0.5 mm thick sheet

710.59

-

1013.56

... More
Aluminium sheet ridging fitted with self tapping screws,EPDM washers etc complete.(Minimum 225mm end lapping).(A) 300 mm lapping each way.(b) With 0.91 mm sheet.

60.25

-

537.32

... More
Galvanised iron sheet eaves gutter fitted and fixed with necessary 50 mm X 6 mm M.S flat bar clamps bent to design,bolts, nuts, washers etc. complete. Eaves gutter made of 0.63mm. sheets.(300mm End lapping)(b) 300 mm. wide gutter

100.5

-

454.74

... More
Holding down bolt with nut including 100 x 100 x 6 mm plate washer at bottom fitted complete and packing the hole with cement concrete or cement grout as directed.(iii) 25 mm dia.(c) 750 mm long

64

-

574.65

... More
250 mm thk. Brick work with 1st class bricks in cement mortar (6 : 1)- a) In Foundation & Plinth (GL.TO P.L)

51.3

-

5538.36

... More
Brick work with 1st class bricks in cement mortar (1:6)(b) In superstructure, ground floor

12.22

-

5790.61

... More
Pre-Constructional Anti-termite Treatment: Treatment to the back filling of R.C.C. foundation with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight at the rate of 7.5 ltr. per sq.m. of the vertical surface of the substructure of each side of the foundation. The work shall be carried out as per specification as described in para 6.3.1 of code IS-6313 (part-II) 1981 (Mode of measurement will be per sq.m. of vertical area of foundation treated).

420

-

154.97

... More
40 mm. thick damp proof course with cement concrete (1:1.5:3) (with graded stone chips 20 mm nominal size) with water proofing compound of approved brand @ 0.2% weight of cement including cost of materials over two coats of non toxic acrylic polymer modified cementitious waterproofing slurry coat complete [cost of water proofing compound and non toxic paint to be paid seperately) for underground water retaining structures.

24.63

-

345.02

... More
125 mm. thick brick work with 1st class bricks in cement mortar (4 : 1)

107.4

-

762.43

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](i) With 1:6 cement mortar,(b) 20 mm thick plaster

236.38

-

182.12

... More
(i) With 1:6 cement mortar,(c) 15 mm thick plaster

146.15

-

159.5

... More
Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick)

146.15

-

136.88

... More
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification)including cleaning and smoothning of surface.Two Coats

146.15

-

79.18

... More
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface toreceive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC.

236.38

-

51.02

... More
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.b) Premium 100% Acrylic Emulsion

236.38

-

95.02

... More
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(ii) Grill weighing above 16 Kg./sq.mtr and above

3.28

-

11116.3

... More
(b) Extra for work in grill gate.(I) For hanging and locking arrangements including supply ofmaterials and labour complete.(15% extra over the corresponding item of grill )

0.49

-

11116.3

... More
Supplying, fitting, fixing, Chain link fencing of approved quality with R.C.C posts wooden posts or iron posts by means of galvanised "C" clips to grid of horizontal strands of galvanised high tensile spring steel wire of 12 S.W.G which have to be tensioned and fixed to the vertical posts by means of galvanised special clips, bolts and nuts etc.(The rate is exclusive of the cost of posts).(I) 50 mm. x 50 mm. x 8 g.

295.06

-

468.32

... More
a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.

680.48

-

32.8

... More
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface :With other than hi-gloss of approved quality-(iv) Two coats (with any shade except white)

680.48

-

81.45

... More
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm.

30

-

134.92

... More
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation.

6

-

87.71

... More
Single brick flat soling with picked jhama bricks including ramming and dressing bed to proper level and filing joints with powdered earth or local sand.

30

-

364.25

... More
(II) Cement concrete with 30 mm down graded shingles excluding shuttering.N.B. Variety.In ground floor (a) 1:3:6 proportion

2.25

-

3838.16

... More
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] M 25 Grade.(ii ) N.B. Variety (Stone Metal)

6.26

-

6450.1

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.

59.67

-

371.03

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation, basement and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel I. SAIL/ TATA/RINL

0.91

-

69302.27

... More
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm.

28.42

-

134.92

... More
(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)

302.4

-

487.9

... More
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.

504

-

27.15

... More
(II) Cement concrete with 30 mm down graded shingles excluding shuttering.N.B. Variety In ground floor (a) 1:3:6 proportion

9.47

-

3838.16

... More
Granular Sub-base with Graded Material (Table:- 400-1):B. By Mix in Place Method : Construction of granular sub-base by providing graded material, mixing by mix in place method with Rotavator at OMC, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber, compacting with vibratory roller to achieve the desired density, including lighting, uarding, barricading, including cost of all materials, machinery, tools and plants including cost of quality control complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).(i) Grading - I :

99

-

2003.21

... More
(i) Grading - I I :

99

-

1762.29

... More
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(ii ) River Bazree

31.58

-

5437.68

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation, basement and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel I. SAIL/ TATA/RINL

2.97

-

69302.27

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). (f) 25 mm to 30 mm shuttering without staging in foundation

210.5

-

231.9

... More
Distribution wiring in 1.1 KV, 3x1.5 sq.mm. single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex, Havell’s) in suitable size PVC casing-capping (Pesto/ Precision) incl. necy. fittings etc. to light/fan point with Modular type switch (Crabtree) fixed on Modular GI / PVC switch board with top cover plate on wall incl. mending good damages to original finish (for Implement shed). Av. Run- 12 mtr.Single LED tube light pt. – 9 nos,Ceiling Fan point – 6 nos.

15

-

1457.09

... More
Fixing single LED Tube light fitting suspended 25 cm bellow the ceiling with 2 nos. U type M.S. clamp and connecting the length of PVC insulated wire and painting etc.

9

-

266.28

... More
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x 1.5 sq. mm.) flexible copper wire.

38

-

192.86

... More
Fixing of 240 volt, 1200 mm sweep ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sq.mm. flexible copper wire.

6

-

82.13

... More
S & F. 240V, 2 Modular socket type fan regulator (Step type) (Crabtree) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.

6

-

481.55

... More
S & F. MS fan clam of two piece type for RC ceiling fabricated from 40 mm x 9 mm MS flat incl. making good damages to building roof with satisfactory finishing and painting.

6

-

301.12

... More
Supply & Fixing 240 V, 6/16 A, 3/5 pin Modular type plug socket (Cabtree) with 16A Modular type switch, without plug top on PVC Modular type switch board with top cover plate on wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. for power points..

6

-

567.41

... More
S and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex, Havell’s, Polycab) of the following sizes in 25 mm. PVC casing capping incl. all fittings and making necy. connection as required.a). 2x2.5 + 1x1.5 for power plug pts.

120

-

126.9

... More
b). 3x 1.5 sq.mm. for sub main line.

70

-

105.76

... More
S & F of 63 amp, 8-way, double door HTPN MCB DB enclosure embedded in wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment and painting (Havell’s).

1

-

4768.23

... More
S & F. 415 volt, 63 amp. 4 pole, MCB Isolator on din rail of existing DB and necessary connection (Havell’s).

1

-

854.85

... More
S & F. double-door 12- way SPN MCB DB enclosure embeded in wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment at sale counter (Havell’s).

1

-

1786.84

... More
S & F. 240 volt, 40 amp. MCB DP Isolator on din rail of existing DB and necessary connection (Havell’s).

1

-

258.82

... More
S & F. 10-32 amp, 240V SP MCB, ‘C’ curve on din rail of existing PDB & DB and necy. connection (Havell’s).

34

-

209.04

... More
Laying of following cables on wall/surface incl. S & F. MS saddles with earthing attachment in 10 SWG GI wire, making holes etc. as necy. mending good damages and Painting.1). 4-core, 16 sq. mm. from panel at nearest workshop to TPN MCB DB at implement shed.

80

-

74.65

... More
2). 2-core, 10 q. mm. from HTPN MCB DB to SPN MCB DB in implement shed.

50

-

70.92

... More
S & F. M.S. gland complete for following XLPE/PVC armoured cables- a). 4-core, 16 sq. mm.

4

-

164.25

... More
b). 2- core, 10 sq. mm.

2

-

143.09

... More
Finishing the end of following XLPE/PVC armoured cables by socket, tapes & jointing materials -a). 4-core, 16 sq. mm.

4

-

118.21

... More
b). 2-core, 10 sq. mm.

2

-

42.3

... More
Earthing with 50 mm dia. ISI medium GI pipe 3.64 mm thick x 3.04 mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 mts. long), 13 mm dia. x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia. GI pipe protection (1 mt. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 mts. below the ground level.

2

-

1703.47

... More
Connecting the equipments to earth busbar including S & F. 8 SWG copper solid wire on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.

3.5

-

696.61

... More
Supply, fixing and connection of 415 volt, 63 amp. Sheet steel Main Switches on angle iron frame on wall (Havell’s).

1

-

4439.73

... More
Supply & Fixing 50 mm dia. 3.20 metre long (incl. bends) ‘L‘ Type service bracket on wall for carrying 4 wires and an earth wire complete with Galv. clamp for stay, insulators etc.. 7/14 SWG stranded Galv. (Hot Dip) wire for stay with 230x13 mm dia. straining screws, 75x88 mm porcelain shackle insulators with Galv. (Hot Dip) strips etc. and painting.

3

-

2078

... More
Supply of following 1.1 KV grade, XLPE/ PVC, armoured aluminium cable (Gloster, Crystol, Havell’s) –a). 4-core, 16 sq. mm.

80

-

210

... More
b). 2-core, 10 sq. mm.

50

-

142

... More
Supply of single LED tube light fittings with one no. 240 volt, 20 watt LED Retrofit T8 Tube. Crompton – LED BATTEN – IGP131 LT8-16 and Tube – LT8-20 or equivalent Philips and Havell’s.

9

-

1364

... More
Supply of 240 volt, 1200 mm sweep, 1440 RPM ceiling fan (Orient – Summer Cool, Summer King).

6

-

2326.94

... More
Extension of fan down rod by 12 mm. dia. Iron rod.

6

-

300

... More
Making arrangement for fixing the main switch, TPN DB, SPN DB and switch boards in the net wall.

1

-

3000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.