The West Bengal Small Industries Development Corporation Limited Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
The West Bengal Small Industries Development Corporation Limited - WBSIDCL Tender
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date19 Feb 2024
Closing Date27 Feb 2024
Tender Amount₹ 4,93,527
Costs
EMD
₹ 9,871Document Cost
₹ 354Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MSMET_669829_2Bid Award Id
ViewTender No
NIET 39 (Elec.) of 2023-24Tender Authority
The West Bengal Small Industries Development Corporation Limited ViewPurchaser Address
-Website
http://https://wbtenders.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Charges for all required instruments and tools & tackles for the aforesaid job.
1
1000
-
Dismantling, Servicing, cleaning, testing, re-fifling and calibration of the 160 KVA - 6kv/0.433kv Transformer consist of over curren-2nos , Earth fault - 1no, differential relay, under voltage relay-1no, Transformer protection relay-3nos, master trip relay - 1nos for Each trans former of magnetic core balance test, magnetizing current test, voltage ration ratio, winding resistance test, vector group confirmation, IR & PI test, transformer auxiliary protection devices test, capacitance tanδ test including all required instruments and tools & tackles.
4
47843
-
Supply of surge arrestor (9KV/10KV)
3
37362
-
Servicing and overhauling 630 Amps, 415Volt A.C.B. after withdrawing the breaker from its track, complete servicing the breaker, cleaning, moving and fixed contacts and adjustment incl.mechanical lever, greasing, oiling etc. and disconnection of the armoured cable and cleaning the surface with carbon tetra chloride, marking cloth, emery papers and applying of petrolium jelly etc. to the socket terminals and taping with PVC tapes and re- connection of the same as per direction of E.I.C.
6
43734
-
Preliminary checking, testing, servicing and overhauling of M.C.C.B. panel consisting of 3 nos. 200 amps M.C.C.B., 11 nos. 100 amps, M.C.C.B., 4 nos. 80 amps, 4 nos. 40 amps re-assembling the loose components, making all interconnection, checking all instruments, including supplying all and replacing all wornout/missing pefly spares, nuts, bolts etc. greasing and tapplings where necessary as per direction of E.I.C.
2
3838
-
Supply & delivery of the following Single Function Meter with I/P-50-550VAC(P-P), Aux Sup-80-300 VAC, CT Secondary-1A/5A with inbuilt Selector Switch for 3-Ph, CT/PT programmable (L&T/ABB/SCHNEIDER): 3 Ph Digital Voltmeter, (Class-1)
2
3048
-
Supply & delivery of the following Single Function Meter with I/P-50-550VAC(P-P), Aux Sup-80-300 VAC, CT Secondary-1A/5A with inbuilt Selector Switch for 3-Ph, CT/PT programmable (L&T/ABB/SCHNEIDER): 3 Ph Digital Ammeter, (Class-1)
2
3048
-
Supply & delivery of the following Current Transformer (Make: KAPPA/AE): Ratio 50-25/5+5A, CL-1+5P10, 15VA double core, dual ratio, STC 25KA for 1sec. Resign cast.
2
1389
-
Supply of Indicator unit of colour red,yellow,green, Blue (Make : L&T or eq)
45
4973
-
Supply of Power pack for 11 KV HT panel, (Make : Approved by EIC)
1
17877
-
Making Indoor type End termination Joint by providing all required terminal joints accessories {viz Heat Shrink Type End Termination Jointing Kits complete with all accessories for 3 core 6.6KV/11KV (E) XLPE Screened Cable, Aluminium Conductor} & man/equipments tools & tackles etc with the relevant Switch Gear inside the Pumping Station or Switch Room with care & caution including compliance of relevant safety norms & conforms to the relevant IS and complete in all respect as per direction of EIC: 120 Sq mm Indoor type Heat Shrinkable Joint (Rechem KIT No- EPKT 3111)
4
89027
-
Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 x 19/8 stranded GI (Hot Dip) wire (4 Mts. long), 25
mm dia x 150 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
3
13479
-
Extra for treatment of soil by using salt & charcoal or coke for plate electrode
3
1898
-
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
3
3271
-
Connecting the equipments body to earth busbar incl. S & F
50 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with
GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc.
30
7079
-
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
40
6578
-
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages: No. 4 SWG
50
1072
-
Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting.
30
2538
-
Laying of cable above 3½ core 50 sqmm and upto 3½ core 90
sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
40
3956
-
Laying of cable above 3½ core 90 sqmm and upto 3½ core 150 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
30
3074
-
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting.
70
5005
-
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
-
-
-
3½ core 185 sqmm cable
2
939
-
3½ core 150 sqmm cable
2
713
-
3½ core 70 sqmm cable
4
1010
-
3½ core 50 sqmm cable
5
1173
-
3½ core 35 sqmm cable
7
1351
-
3½ core 25 sqmm cable
6
1086
-
4 core 16 sqmm cable
4
629
-
4 core 10 sqmm cable
2
314
-
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
-
-
-
3½ core 185 sqmm cable
2
1301
-
3½ core 150 sqmm cable
2
1034
-
3½ core 70 sqmm cable
4
1253
-
3½ core 50 sqmm cable
5
1245
-
3½ core 35 sqmm cable
7
1318
-
3½ core 25 sqmm cable
6
786
-
4 core 16 sqmm cable
4
452
-
4 core 10 sqmm cable
2
159
-
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
-
-
-
10sqmm
8
104
-
16sqmm
10
202
-
25sqmm
10
244
-
Supplying 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes and making necy. connection as required
-
-
-
10sqmm
10
1179
-
16sqmm
25
4513
-
25sqmm
25
8744
-
Straigh through Jointing of cable of different size by compound jointing kit including S&F ferrul, tapes and jointing materials (Brand approved by EIC)
-
-
-
3½ / 4 core 185 sqmm cable
2
5687
-
3½ / 4 core 95 sqmm cable
4
8032
-
3½ / 4 core 10-16 sqmm cable
2
2483
-
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection
-
-
-
200 A (Make: Legrand or equ. as approved by EIC)
1
17636
-
80 A (Make: Legrand or equ. as approved by EIC)
1
8427
-
100 A (Make: Legrand or equ. as approved by EIC)
3
25539
-
40 A (Make: Legrand or equ. as approved by EIC)
1
7146
-
Supply of 6-16A Ammeter Selector Switches for Line Currents with OFF with CT (Make: L&T or equ, as approved by EIC)
2
717
-
Supply of 10A Voltmeter Selector Switches for Voltage between Phases with OFF (Make: L&T or equ, as approved by EIC)
2
491
-
Supply of die cust door lock arrangement for electtical panel.
6
283
-
Supply of Electrical Panel Board Edge EPDM Rubber Gasket 10mm(W) x 2mm Groove
5
1176
-
Supply of Master Trip Relay of VCB panel (Make: Alstom, Model: VAJH VAJS VAJHM or equ. as approved by EIC)
1
8334
-
Supply of 3 pole Auxiliary Relay of VCB panel (Make: Alstom or equ. as approved by EIC)
1
7779
-
Supply of 3 Phase Over Current + Earth Fault Relay with High Set. (Make: L&T - Model: MC61AnX or equ. as approved by EIC)
1
18892
-
Servicing and overhauling of 800 Amps, 11 KV three panel V.C.B dismantling the rack from the housing, opening the components, necessary cleaning of the component, carbonised portion, changing of rubber gasket, defective parts, cleaning of all machanism parts and lubricating the mechanism, opening of C.T & P.T.S, busbar spout assembly cleaning the same and insulated properly by supply of C.T.C etc and refitting all the parts to its original position by making all relevant electrical connection, panel wiring etc. for satisfactory & operation.
2
27847
-