The West Bengal Small Industries Development Corporation Limited Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
The West Bengal Small Industries Development Corporation Limited - WBSIDCL Tender
Civil And Construction
Eprocure
Opening Date17 Oct 2023
Closing Date7 Nov 2023
Tender AmountRefer Documents
Costs
EMD
₹ 45,000Document Cost
₹ 1,180Tender Fee
Refer Documents
Summary
Wbsidcl/26 Elec Of 2023-24 Sl 1
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MSMET_594236_1Bid Award Id
ViewTender No
NIEQ 26 (ELEC) OF 2023-24Tender Authority
The West Bengal Small Industries Development Corporation Limited ViewPurchaser Address
-Website
http://https://wbtenders.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Origin : Manufactured in India
-
-
-
... More
Efficiency: = 18%
-
-
-
... More
Fill factor: = 70%
-
-
-
... More
Degradation warranty: =90% of design nominal power after 12 years, =80% of design nominal power after 25 years.
-
-
-
... More
Module frame: Non-corrosive and electrolytically compatible with the mounting structure compatible with the mounting
structure
-
-
-
... More
Termination box: Thermo-plastic, IP 66, UV resistant
-
-
-
... More
Blocking diodes : Schottky type Each PV module must contain 3 nos. of Bypass diodes
-
-
-
... More
Module minimum rated power The nominal power of a single PV module shall not be less than 375Wp.
-
-
-
... More
Potential Induced Degradation(PID) Test :Modules with PID testing certificate at following test conditions or better:
-
-
-
... More
a) Temperature: 450 ± 2°C
-
-
-
... More
b) Negative Voltage of 1000 volts
-
-
-
... More
c) Relative humidity: 70%
-
-
-
... More
d) Test period: 96 hours
-
-
-
... More
RF Identification tag for each solar module: Yes. Must be able to
withstand environmental conditions and last the lifetime of the solar module
-
-
-
... More
RF Identification tag data :
-
-
-
... More
a) Name of the manufacturer of PV Module
-
-
-
... More
b) Name of the Manufacturer of Solar cells
-
-
-
... More
c) Month and year of the manufacture (separately for solar cells and module)
-
-
-
... More
d) Country of origin
-
-
-
... More
e) I-V curve for the module
-
-
-
... More
f) Wm, Im, Vm and FF for the module
-
-
-
... More
g) Unique Serial No and Model No of the module
-
-
-
... More
h) Date and year of obtaining IEC PV module qualification certificate
-
-
-
... More
i) Name of the test lab issuing IEC certificate
-
-
-
... More
j) Other relevant information on traceability of solar cells and module as per ISO 9000 standard
-
-
-
... More
Power output rating :
-
-
-
... More
To be given for standard test conditions (STC). I-V curve of the sample module should be submitted.
-
-
-
... More
Compliance with standards abd codes :
-
-
-
... More
IEC 61215/ IS 14286, IEC 61730 Part 1 and 2
-
-
-
... More
Salt Mist Corrosion Testing As per IEC 61701
-
-
-
... More
Thickness: 4.0 mm minimum for 72 Cell PV Module
-
-
-
... More
S & I Hot dip galvanized MS Structured for mounting of about 47 nos. SPV Modules with galvanization thickness of minimum 85 micron as per following specification. (as per approved drawing)
1
-
-
... More
Wind velocity withstanding : capacity 120 km / hour
-
-
-
... More
Structure material : Aluminium alloy 6063-T6 with an L-angle profile size of not less than 50 x 50 x 6mm and U-profile channels of not less than 33 x 33 x 3 mm.
-
-
-
... More
Bolts, nuts, fasteners, panel mounting clamps : Stainless steel SS 304
-
-
-
... More
Mounting arrangement for RCC flat roofs : With removable concrete ballast made of pre-fabricated PCC (1:2:4), M15
-
-
-
... More
Mounting arrangement for metal sheet roofs Mounting directly on the sheet metal, ensuring stability and wind withstanding capacity, or penetrating the sheet metal and fixing to the sub- structure, ensuring that the roof remains water proof and ensuring stability and wind withstanding capacity.
-
-
-
... More
Mounting arrangement for elevated structure: The elevated structure has to be securely anchored to the supporting surface. Concrete foundation of appropriate weight and depth for elevated structure direct mounted directly on the ground bolted with anchor bolts of appropriate strength for elevated structures mounted on RCC surface.
-
-
-
... More
Mounting arrangement for ground installations: With removal concrete ballast made of pre-fabricated PCC (1:2:4), M15, assuring enough ground clearance to revent damage of the module through water, animals and other environmental factors.
-
-
-
... More
Installation: The structure shall be designed for simple mechanical on-site installation. There shall be no requirement of welding or complex machinery at the installation site.
-
-
-
... More
Minimum distance between roof edge/fence and mounting structure: 600 mm to 1000 mm as approved by EIC as per site condition.
-
-
-
... More
Access for panel cleaning and maintenance: All solar panel
must accessible from the top for cleaning and from the bottom for access to the module-junction box.
-
-
-
... More
Panel tilt angle: North-south orientation with a fixed tilt angle
depending on the location. The tilting angle range in Karakal will be 10.5 to 11 degrees, south facing.
-
-
-
... More
S & Macking of necessary concrete foundation column for module mounting structure as mention below
-
-
-
... More
S & F 15 KW, 3-phase, 415 VAC adjustable up to (+ 12.5%,- 20% VAC), 50 Hz AC Grid-Tied Inverter of following specifications and as required necessary connection and earthing attachment. (Make- IEC certified according to
MNRE standard as approved by EIC) having the following specification:
1
-
-
... More
Total output power (AC) : To match solar PV plant capacity
while achieving optimum system effiency (DSP Band inverters to ensure higher efficiency)
-
-
-
... More
Input DC voltage range: 200V - 950V
-
-
-
... More
Maximum point (MPPT) tracking : Yes
-
-
-
... More
Number of independent MPPT inputs : Minimum 3 nos
-
-
-
... More
RFI : To minimize the both conducted and radiated RFI emissions
-
-
-
... More
Internal Consumption Night : 1.5 Watt
-
-
-
... More
Regulation : Maximum 5% against input voltage and load variation
-
-
-
... More
Dielectric strength : 1.1 KV between input/output with ground with EMI protections & 1.5 KV between input and output
-
-
-
... More
Instrumentation: Input Voltage & Current, Output Voltage & Current, Frequency.
-
-
-
... More
Status Indication : Input, Output, Inverter (On/Trip/Fault/Off)
-
-
-
... More
Fault Indication : Visual indication with blinking super glowing LED audio
-
-
-
... More
Degree of Protection : IP65
-
-
-
... More
Cooling : Fan forced
-
-
-
... More
Power Switching : High Efficiency IGBT
-
-
-
... More
Power Control : Phase controlled pulse width modulation
-
-
-
... More
Earthling Provisions : AC bypassing to earth on Inverter and DC
inputs
-
-
-
... More
Surge rating : 150% of rated output for 30 seconds
-
-
-
... More
Grid Acceptable Range : AC Voltage +/- 17%, +/- 3
-
-
-
... More
Operation AC voltage: Three phase 415 V ( + 12.5%, -20 %)
-
-
-
... More
Operating Frequency range : 47.5 - 52.5 Hz With range for grid
voltage and frequency parameters
-
-
-
... More
Nominal frequency : 50 Hz
-
-
-
... More
Power factor of the inverter :. 0.98 at nominal power
-
-
-
... More
Total harmonic distortion : Less than 3 %
-
-
-
... More
Built - in Protection :i. Input over voltage
ii. Reverse-polarity protection
iii. Reverse current to PV array protection, over voltage,
iv. Under voltage protection
v. Over current
vi. DC inject protection to grid
vii. Over current
viii. Over and under grid frequency protection
ix. Anti-Islanding protection (As per VDE 0126-1-1/IERC 60255.5 or equivalent standards. Testing as per IEC)
-
-
-
... More
Operating ambient temperature range: - 10 degree C to + 60 degree C
-
-
-
... More
Humidity : 0 - 95% Rh
-
-
-
... More
No load losses : less than 1% of Rated output
-
-
-
... More
Self commutated IGBT base invertors with pulse width modulation invertor on/off Switch to be provided
-
-
-
... More
S & Laying of suitable size of wires & Cables including Wiring materials as per following specification. For dc cable ; suitable size of tinned annealed standard flexible copper conductor as per IS 694 (Make: As per Indian Standard according to MNRE standard).For ac cable : 1.1 KV, excellent resistance to heat, fire, oil,coil,abrasion,UVradiation,armoured /unarmored as per requirement standard flexible copper/armored AL. PVC insulated as per following specifications. .(Make: : As per Indian Standard according to MNRE standard as approved by EIC)
1
-
-
... More
General Test & Measuring Methods - IEC 61427
-
-
-
... More
PVC insulated cables for working Voltages up to & including 1100V - IS 694/IS 1554
-
-
-
... More
PVC insulated cables for working Voltages up to & including 1100V, UV resistant for outdoor installation - IS/IEC 69947
-
-
-
... More
DC Cable
-
-
-
... More
Conductor: Tinned annealed stranded flexible copper
-
-
-
... More
Insulation: PVC
-
-
-
... More
Standard : IS 694
-
-
-
... More
Make: : As per Indian Standard according to MNRE standard as approved by EIC
-
-
-
... More
AC Cable
-
-
-
... More
Rated Voltage : 1.1 KV
-
-
-
... More
Construction: Excellent resistance to Heat, Fire, Oil, Cold, Water,
Abrasion, UV radiation
-
-
-
... More
Type: Armored or Unarmored as per requirement
-
-
-
... More
Conductor: Stranded flexible Copper /Armored aluminum
-
-
-
... More
Insulation: PVC
-
-
-
... More
Standard: IS 1554
-
-
-
... More
Make: As per Indian Standard according to MNRE standard
-
-
-
... More
S & Fixing PV Array Junction Box (AJB) IP65 withstand voltage
1000VDC, as per following specifications incl. necessary connection and earthling attachment. (Make as approved by EIC)
1
-
-
... More
Maximum Roof space utilization : 12 sqm / kwp for true south
-
-
-
... More
Degree of Protection: IP65
-
-
-
... More
Design Factor of Safety: 1.5
-
-
-
... More
Material: Polycarbonate
-
-
-
... More
Withstanding Voltage : 1000V
-
-
-
... More
With standing Temperature : 100 degree C
-
-
-
... More
Accessories mounting arrangement : As suitable
-
-
-
... More
Number of Strings entry : As may be required
-
-
-
... More
Cable Entry and Exit
-
-
-
... More
Position : Bottom at cable entry and exit
-
-
-
... More
Cable Entry and Exit connector type : MC4(PV Array String cable)
-
-
-
... More
Cable gland : Earthling cable entry
-
-
-
... More
Fuse with fuse holder
-
-
-
... More
Position : Positive and negative terminal for each series string
-
-
-
... More
Type: Glass fuse, for PV use only
-
-
-
... More
Rating : Current: Minimum 1.25 times the rated short-circuit current of the series string
-
-
-
... More
Earthing Provision : Terminal blocks will have to be provided for Earthing
-
-
-
... More
The footing base of the structure should be painted by good quality (IS approved) water proofing bituminous paint.
-
-
-
... More
S & F Grid Interfacing LT Panel / ACDB as per following
specifications with Energy meter including necessary connection and earthing attachment.
1
-
-
... More
MCB
-
-
-
... More
Make : : According to MNRE standard as approved by EIC
-
-
-
... More
Type : 4 Pole
-
-
-
... More
Rating : 415V, 16A
-
-
-
... More
Bus Bar
-
-
-
... More
Rating :3 Ø with Neutral, 415V 16A
-
-
-
... More
Type : Aluminum
-
-
-
... More
Indicator : Provided
-
-
-
... More
Earthing Provision: Terminal Blocks will be provided for Earthing
-
-
-
... More
Enclosure
-
-
-
... More
Degree of Protection : IP 42/43
-
-
-
... More
Type : Sheet Steel, Powder coated. Horizontal / Vertical Enclosure dust and Vermin proof
-
-
-
... More
Type of Fixing: Wall Mounted
-
-
-
... More
Accessories mounting arrangement : DIN Rail or as Suitable
-
-
-
... More
S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. complete duly grouted on the parapet etc. in CC mortar ( 4:2:1).
4
-
-
... More
Supply & fixing GI (Hot Dip) strips 25 mm x 6 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to building works
100
-
-
... More
Supply & fixing of GI (Hot Dip) strips 25 mm x 6 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart incl. mending good damages to building work
50
-
-
... More
For further technical details of Item no.-1.09 to 1.11 please refer to "Technical Specification of SPV Modules"
-
-
-
... More
Connectivity arrangement i.e; connection of net metering
system as follows with local DISCOm network and coordination with DISCOm as stated below.
1
-
-
... More
For Net metering system: The existing service connection energy meter is to be replaced by the distribution licensee with a bidirectional energy meter of the same accuracy class as the existing service connection meter. If the existing service connection meter is already programmed for bidirectional energy recording there will be no need of replacing the matter.
-
-
-
... More
Installation, Testing and commissioning including Transposition charges.
1
-
-
... More
a) Type Test Certificates shall be provided for the solar modules and the solar grid inverters to provide evidence of the complience with standards as specified this Technical Specification. Client reserves the right to ask for additional test certificates or (random) tests to establish compliance with
-
-
-
... More
Five (5) years Annual Maintenance as per follows.
5
-
-
... More
Preventive/Routine Maintenance: This shall include activities such as routine checking the health of the SPV Power plant, tightening of all electrical connections, changing of tilt angle of module mounting structure and any other activity that may be
-
-
-
... More
Breakdown/Corrective Maintenance: Whenever a complaint is lodged by the user, the bidder shall attend to the same within a reasonable period of time of 48hours and in any case the breakdown shall be corrected within a period not exceeding 72hours from the date of complaint.
-
-
-
... More
a) Adequately trained manpower, specifically trained by the bidder for carrying out the service activities
-
-
-
... More
b) The suppliers should provide generation data on annual basis for the initial 2 years. The security money will be released based on performance of the plant in respect of generation
-
-
-
... More
c) Adequate spares and manpower for ensuring least downtime of an individual system.
-
-
-
... More
S & F other accessories are as follows.
-
-
-
... More
Danger Board of Size 200 mm x 300 mm
1
-
-
... More
S/I in position approved make dry chemical powder fire extinguisher of following capacity complete with chromium plated gun metal union (cap), fitted with braided hose and open nozzle with initial charge of dry chemical powder and gas as (Make approved by EIC)
3
-
-
... More
S/I in position approved make carbon dioxide 4.5 Kgs capacity
fire extinguisher, made of high pressure with wheel type valve with one meter long braided high pressure discharge hose (Make approved by EIC)
3
-
-
... More
GI bucket as per IS, capacity 9 Ltrs filled with sand. (Fire Shield/ Minimax Make as approved by EIC).
3
-
-
... More
Supplying and fixing 415V 32A TPN Main Switche in Sheet steel enclosure with fuse on angle iron frame on wall. (Make According to MNRE standard
2
-
-
... More
Supply of 1100 Volt grade 4 core 10 sq.mm Aluminium Conductor, XLPE Insulated, Armoured Power Cable. (Make According to MNRE standard approved by EIC)
250
-
-
... More
Laying of 4 core 10 sqmm cable on wall/surface incl. S & F MS saddles with making holes etc. as necy. mending good damages and painting. (Without earthing attachment 10 SWG GI)
200
-
-
... More
Laying of 4 core 10 sqmm cable through existing GI Pipe.
50
-
-
... More
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof
entry of XLPE/PVC armoured cables as below : 4 core 10 sq.mm
4
-
-
... More
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 4 Core 10 sqmm.
4
-
-
... More
Supplying & fixing 32 mm dia medium gauge GI Pipe ( ISI- Medium) Protection with necessary fittings and jointing metarials as required. (Make approved by EIC)
290
-
-
... More
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below
11
-
-
... More
Extra for treatment of soil by using salt & charcoal or coke for plate electrode.
11
-
-
... More
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
2
-
-
... More
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages: No. 4 SWG
158.87
-
-
... More
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 25 mm size PVC rigid conduit (Precession make or equ. as approved by EIC) 'FR' incl. necy.fittings as required: 4 x 6 sq.mm + 2 x 4 sq.mm ECC.
10
-
-