The West Bengal Small Industries Development Corporation Limited Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

The West Bengal Small Industries Development Corporation Limited - WBSIDCL Tender

Works
Civil And Construction
Coronavirus COVID 19
Eprocure
Opening Date12 Sep 2019
Closing Date26 Sep 2019
Tender Amount₹ 80,97,969 
Notes
Download

Costs

Summary

Wbsidcl/23 Elec Of 2019-20 Sl 1

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
INCOMING & OUTGOING

-

-

-

... More
1 Set - 630A TP, 11KV, 50Hz Vacuum Circuit Breaker (VCB) having STC of 26.3 KA for 3 seconds having the following components.

-

-

-

... More
a) 1 Set (3 Nos/Set) - 80-40/5-5A Dual Core Cast Resin Type Current Transformer CL-5P10 for protection & Cl -0 .5 for metering with 15VA burden each.

-

-

-

... More
b.1) 1 Set (2-PH)- Cast Resin Construction Type Potential Transformer 11 KV/√3 : 110V/√3 with Cl - 0.5 accuracy with 500VA burden with HRC fuses at primary & secondary for protection.

-

-

-

... More
b.2) 1 Set (3 Nos/set)- Cast Resin Construction Type Potential Transformer 11 KV/√3 : 110V/√3 with Cl - 0.5 accuracy with 50VA burden with HRC fuses at primary & secondary for protection.

-

-

-

... More
c) 1 Set - Analogue ammeter (0 - 100A) with Ammeter Selec tor Switch & HRC fuse protection to be operated with CT.

-

-

-

... More
d) 1 Set - Analogue Voltmeter (0 - 15 KV) with Voltmeter Sel ector Switch & HRC fuse protection to be operated with PT.

-

-

-

... More
e) 1 Set - Neutral Displacement and Time Delay Relay.

-

-

-

... More
f) 1 Set - Numerical Type IDMT Relay (50/51/50N/ 5IN/86/2/97) with two elements for overcurrent & earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time & current settings & high set instantaneous unit (Micom-P-127 or equivalent).

-

-

-

... More
g) 1 Set - Numerical Type Overvoltage & Under Voltage Relay having settings ranging from 80% to120% in equal steps.

-

-

-

... More
h) 1 Set - High Speed Master Trip Relay with Auxiliary Contacts.

-

-

-

... More
i) 1 Set - Trip Circuit Supervision Relay.

-

-

-

... More
j) 1 Set (3 Nos/Set) R-Y-B LED Phase Indication Lamps with 3 Nos 1A SPMCB protection.

-

-

-

... More
k) 1 Set - ON/OFF/TRIP/TEST/Trip CIRCUIT Healthy /Service position /SPRING CHARGE/PT fuse failure Indicator Cluster Type LED Indication Lamps & Push Buttons.

-

-

-

... More
l) 1 Set - 10 Window Annunciator Units.

-

-

-

... More
m) 1 Set - Earth Bus Bars and all other accessories.

-

-

-

... More
n) 1 SET (3 Nos.) Surge Arrestor (Metal Oxide, Gapless, Class-II) to be provided.

-

-

-

... More
o) 2 Set-Cable Termination Box (1-Incomer & 1-Outgoing) for termination of 2 run of 11/11 KV(E) grade 3C, 185 sq mm XLPE Insulated Al(A) Cable.

-

-

-

... More
p) 2 Set- T-N-C switch to be provided

-

-

-

... More
q) 1 Set - Flush Mounting Digital Trivector Meter having Class - 0.5 accuracy & Maximum Demand Indication (MDI) Indicator to be operated by CT & PT Supply.

-

-

-

... More
BUSBAR

-

-

-

... More
1 Set - 630A, 12 KV, 50HZ TP Electrolytic Grade Tinned Cu Busbars having a fault level withstand capacity of 26.3KA for 3 seconds.

-

-

-

... More
The scope of erection includes assembly of disassembled/split up sections, loosely supplied relays, meters, busbars etc. of the VCB switch board, earthing at two points, all alignments, leveling, grouting, bolting, base channel fixing, bus wiring etc. as per manufacturer's recomenda tion & site condition and minor modification of of wiring, if reqd. Checking to be done for insulation resistance by megger, funct ioning of closing & tripp ing mechani sm of VCB, operations of all relays & their setting as per requirement of the system. Breaker panel should be Installed, Operated & Tested as per prevailing rules/norms to the full satisfaction to the engineers of all concerned authorities/client/consultant /statutory inspecting authority.

-

-

-

... More
Mandatory Type Test:- (As per IS 3427 & IEC 62271 - 200 clause - 6). The following test have to be conducted from any Govt. NABL accridated laboratory. 1. Lightning Impulse voltage withstand Test at 75kv peak. 2. Dry Power Fequency Voltage withstand Test (sub clause- 6.2). 3. Short Time withstand current & Peak withstand current Test at 25KA for 3 sec with initial peak 66KA for main ckt & 25KA for 1 sec with initial peak 66KA for each ckt (sub clause- 6.6 of IEC 62271-200, & 62271-100, 2008). 4. Temparature Rise Test at 630A, 50Hz. (sub clause- 6.4 & 6.5) 5. Mechanical Operation Test at ambient air temperature (class M2 & IEC 62271-100, 2008):10,000 Operation. 6. Degree of Protection IP5X, (IS 13118 & IS 3427, IEC 62271-100 & 62271-200) 7. Internal arc test- .01 sec [Pho to copies of certificates to be uploaded in online for above] Routine Test:- As per IS 13118, IEC 62271- 100(2008) & 62271- 200(2003) 1. Power Fequency withstand Test on Main Circuit Auxiliary Circuit & Control Circuit. 2. Power Fequency Voltage Test for 1 Min between Terminal with Breaker ON/OFF. 3. Measurement of the Resistance of main Circuit. 4. Measurement of opening & closing times. 5. Mechanical Test. 6. Paint Shade : RAL- 7032.

-

-

-

... More
Terms & Condition:- 1. The rate should be quoted both figure & in words & to be quoted in each set basis. 2. The rate should be quoted incl delivery at work sites & all other charges & taxes. (Delivery site: Malda Silk Park at Malda) 3. Guarantee period 18 months from the date of delivery/date of installation & commiss ioning whichever is later. 4. Price variation clause will not be enter tained. 5. Materials should be delivered at work site/ concerned Section office in consultation with the Assistant Engineer/Project Manager. 6. All sorts of Test Certificate reports must be submitted from the manufacturer at the time of delivery of materials to the concerned officers. 7. Validity offer to be mentioned specia lly & clearly. 8. Quantity may be increased or decreased as per actual requirement. 9. All mandatory NABL accridated test certificates will have to be submitted with Bid Documents during e-tendering. 10. The manufacturer must submit closing & tripping time curve after testing on a breaker analyzer. For major components like C.T, P.T, Met er & relays the routine test certificate of the respective manufacturers need to be submitted. 11. The materials must be delivered within one month from the date of provisional acceptance of all drawings/documents such as GA, SLD, Control Schematics, Terminal Block Details, Data Sheets & Bill of Materials etc. as applicable. 12. Bidder will arrange the technical personnel of manufacturers to be present at site during commissioning. No extra cost can be claimed for this purpose.

-

-

-

... More
TRANSFORMER

-

-

-

... More
Designing, manufacturing, delivery & installation incl placing in position at site, testing & commissioning of 500KVA 11/0.433 KV, 50HZ cu wound indoor cast resin dry type transformer with classH insulation & IP23 enclosure. Vector group DYn11 having HT cablebox & LT cable box with cable gland plate incl all other components as specified. Supp ly of all installation materials like mounting channels as per manufactur er design high tensile bolts, nuts, washers, screws, clamps, painting, earthing, etc. as reqd confirming to the technical specification along with Rating & Diagram Plate, Earthing terminals, lifting lugs, Bidirectional rollers, NCT (600/1A, 5P20, 20VA) & Off Load Tap Link (with tappings +5% to -5% in steps of 2.5%), digital winding temperature indicator with 2 sets of potential free contacts with NCT suliable sensors in each phase complete in all respect as reqd. The installation shall confirm IS: 10028.1981 (Part II) & amended upto date. The rate shall be inclusive of necy civil works, mounting channels, earthing etc. complete in all respect. The transformer shall be installed in the transformer room in substation building. (ABB/Crompton/Voltamp /Seimens or as appd. by EIC)

1

-

1175848.33

... More
Type of Insulation:- Nomex Paper LT & HT coils are insulated with Nomex Paper & Glass Tapes & Vaccum Pressure Impregnated in Silicon Varnish. Core Material:- C.R.G.O/ as specified in ECBC 2007 with Full Mitred Joint Construction.

-

-

-

... More
Winding Material:- E.C. Grade Copper. L.V. Winding:- L.V. windings are made of Copper Flat and capable of withstanding Short Circuit Current Situations as per IS. H.V. Winding:- E.C. Grade Copper. Impedance:- (I.S. Tolerance) : 10%. Losses:- No Load Loss:- To be maintained as per ECBC 2007. Load Loss:- To be maintained as per ECBC 2007. Efficiency:- To be maintained as per ECBC 2007. Full Load:- As per IS. Enclosure Type:- Ventilated with 4mm dia perforated sheet/MS louver guarded by wire mesh suitable for indoor installation.

-

-

-

... More
Material:- 2 mm thick CRCA Sheet. Degree of Protection:- IP 23. Tests:- Routine Tests- As per I.S. 11171-1985/IS:2026. Fault Level:- As per IS specs. Fittings & Accessories:- a) Suitable cable Entry Boxes/In Built cable box along with terminals for both Primary & Secondary as per site condition. b) Two nos. Earthing Terminals. c) Diagram & Rating Plate. d) Temperature Scanner with P.T. 100 Temp. sensor to be embeded in the winding and to be wired upto common scanner.

-

-

-

... More
Testing:- 1. Routine Test. A) Heat Run. B) Lighting Impulse Voltage Withstand Test. C) Short Circuit Test. Certified from CPR/ERDA (NABL Accredicted) of similar or higher rating to be produced.

-

-

-

... More
TERMS & CONDITION:- 1. The rate should be quoted incl. delivery, other cha rges & taxes. (Delivery site:- CFC Building, Malda). 2. Price variation clause will not be enternained. 3. Materials should be delivered to the site/section office in consultation with the concerned Executive Engineer. 4. Routine test to be performed in presence of EIC and submitted at the time of delivery. 5. Test Certificate for Lightning Impulse Voltage Withstand Test & Short Circuit Test from CPRI/ERDA (NABL Accredicted) of similar or higher rating is to be submitted during tender. 6. Bidder will arrange the technical personnel of manufacturer to be present at site during commissioning. No extra cost can be claimed for this purpose. 7. Guarantee period of the Transforner 12 (Twelve) months from the date of commissioning or 18 (Eighteen) months from the date of supply which ever is earlier. 8. Payment will be made as per WBSIDCL Rules. 9. The material must be delivered within 06 (Six) weeks from the date of acceptance, of all drawings/documents such as GA, SLD, Bill of materials, control schematic with terminal block details, data sheets, etc. as applicable.

-

-

-

... More
HT CABLE

-

-

-

... More
SLTC of "11kV grade, 3C x 185 sqmm HT XLPE (UE) Al Ar Cable, insulated stranded AL conductor, conductor screened. insulation screened, flat strip AR inner & overall sheathed cable conforming to IS: 7098/II/85 with latest amendments. The rate shall be inclusive of necy supporting & clamping arrangement for laying of cables within tray/pipe/trench. The installation shall confirm IS:1255. 1983 & amended upto date.

40

-

1545.56

... More
SLTC of 11 KV grade 3C x 185 stranded Al. Cable,Conductor screened, XLPE insulated, insulation screened, strip armoured, inner and overall sheathed cable incl. of necessary supporting & clamping arrangement for laying of cables within tray/pipe/trench. The insulation confirm IS: 1255.1983 & amended upto date.

40

-

19.95

... More
HT CABLE END TERMINATION

-

-

-

... More
S/I/T/C of heat shrinkable indoor type "Cable End Termination Kit" suitable for the 11kV XLPE (UE) cable with epoxy/polyurethane resin based kits, tapes, push on kits, multiconductor const ruciton etc. complete. The installation shall confirm IS: 1255 .1983 & amended upto date.

-

-

-

... More
11kV, 3C X 185 Sqmm XLPE cable end termination kit.

4

-

17618.9

... More
CONTROL CABLE

-

-

-

... More
Supply of "1.1kV grade "Cu. Ar Control Cable" incl terminations as reqd. The rate shall be inclusive of necy supporting & clamp ing arrangement for laying of cables within tray/pipe/trench. The installation shall confirm IS:1255.1983 & amended upto date.

-

-

-

... More
4C X 2. 5Sqmm, Cu. PVC cable.

120

-

154.28

... More
10C X 2. 5Sqmm, Cu. PVC cable.

150

-

319.77

... More
Laying on Cable Tray

-

-

-

... More
Laying of cable as below, on existing Cable Tray & binding with suitable size GI wire.

-

-

-

... More
Up to 50 sqmm

270

-

11.55

... More
S/F compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC Ar cables as below :

-

-

-

... More
For 4 core - upto 6 sqmm

8

-

120.75

... More
For 4 core - upto 16 sqmm

12

-

138.6

... More
Finishing the end of following XLPE/PVC Ar cables by crimping method incl. S/F solderless socket (Dowels make), tapes, anti corrosive paste & jointing materials:

-

-

-

... More
4 core 2.5 sqmm cable

8

-

58.8

... More
4 core 10 sqmm cable

12

-

70.35

... More
EARTH PIT

-

-

-

... More
Construction of "Earth Station" shall confirm IS-3043 with excavation, brick masonary work, GI funnel, salt, charcoal & earth lead connections etc as reqd. The GI funnel & tapping connection shall not be greater than 10" from the FFL.

-

-

-

... More
Earthing with Cu plate (610x610x3mm size) having weight of 9.84 Kg & 1 No 25x5mm Cu strip (3.20 mt long) & 1 no 6 sq mm PVC insulated stranded Cu wire (4 Mt long) incl S/F 15 mm dia GI pipe (ISI-M) protection (4 mt long) to be fillied with bitumen, partly under the ground level & partly above ground level to an average depth of 3.65 Mts below the ground level & restoring the surface duly rammed incl providing 3 mt long, 25 mm dia GI pipe (ISI-M) for periodic treatment, incl. providing masonary enclosure on the top of the earthelectrode of overall size 86.36x86.36x46cm deep (below Ground level) complete with cemented brick work (1:6) of 25 cm width, duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56x35.56cm with locking arrangement, GI reducer & treatment of soil by using salt & charcoal or coke for plate electrode.

2

-

10989.3

... More
Earthing with 65 mm dia GI pipe (TATA-M) x 3.0 Mts long & 1 No. 50 mm x 6 mm galv (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers incl finishing both ends by making holes etc. & S/F 65 mm dia GI pipe (ISI-M) protection (3 Mts. long) to be filled with bitumen partly under the ground level & partly above ground level to an average depth of 3.65 Mts.

14

-

4061.4

... More
Extra for providing masonary enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work (1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer incl drilling of 46 nos. 12 mm dia holes on the GI pipe.

16

-

960.75

... More
Extra for treatment of soil by using salt & charcoal or coke for plate electrode

16

-

557.55

... More
EARTH STRIP

-

-

-

... More
Extra for connecting the neutral of Transformer/Earth busbar to earth electrode incl S/F 50 mm x 6 mm Galv (Hot Dip) steel strip on wall/floor with GI saddles & insulating the same by one layer of PVC strip over one layer of ampere tape.

180

-

235.2

... More
S/L/T/C of "Earth Strip" on wall/tray/trench incl connections by bolting/ riveting/welding etc. as reqd complete.

-

-

-

... More
Providing & fixing earth bus of 50 mm X 6 mm copper strip on surface for connections etc. as reqd.

40

-

2022.91

... More
M.S. structural works in columns, beams etc with simple rolled structural members (e.g. joists, angle, channel sections, Chequered plate conforming to IS: 226, IS: 808 & SP (6)-1964 conn ected to one another with bracket, gussets, cleats as per design, direction of EIC complete incl cutting to requisite shape & length, fabrication with necy bolting, metal arc welding conforming to IS:816-1969 & IS:1995 using electrodes of appd make & brand conforming to IS:814- 2004, haulage, hoisting & erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas & hire charge of all tools & plants & labour reqd for the work incl all incidental chages such as electricity charges, labour insurance charges etc. For structural members of specified sections weighing less than 22.5 Kg/m.

10.2

-

72603

... More
Supply, febrication & install of MS chequered plates work welded in built up sections/framed work, incl cutting, hoisting, fixing in position & applying a two priming coat of appd MS primer as reqd. incl use of MS angle, MS chequered plate, for trench cover with handrail for removing, all complete.

1800

-

83.15

... More
SAFETY ITEM

-

-

-

... More
Supply & Laying/Fixing of following safety items,

-

-

-

... More
Rubber mats of 11kV grade 2.0MtrsX1.0Mtrs & 12mm thick ness as reqd by the electrical inspectorate, DOE & confirm to to IS : 5424:1969 and BS 921:1976.

12

-

1721.46

... More
Rubber mats of 1.1kV grade 2.0MtrsX1.0Mtrs & 8.0mm thick ness as reqd by the electrical inspectorate, DOE & confirm to to IS : 5424:1969 and BS 921:1976.

32

-

1118.44

... More
First Aid Box.

1

-

250

... More
Shock treatment chart with teak wood frame & glass cover as appd by electrical inspectorate, DOE.

2

-

1036

... More
Drawing display board suitable for "A0" size of drawing with lamination. (As built drawing of electrical single line diagram with teak wood frame and glass cover)

2

-

1500

... More
MEDIUM VOLTAGE SWITCH BOARD

-

-

-

... More
415V MAIN LT PANEL

1

-

865886.18

... More
Supply, delivery at site eraction, testing & commissioning of vertical floor mounting free standing, extensible on either side, compartmentalised cubical type panel board made of 14 SWG (2.04 mm) CRCA MS sheet suitable for 500/415V, 50HZ, AC, 3 Ph & N system having the following features panel shall be de signed to ensure that the weight of the components is adequa tely supported without deformation or loss in allignment. The doors of the cubicle shall be fitted with dust excluding neoprene gaskets with fastners for proper compression of the gaskets.

-

-

-

... More
Panel shall be multitier comparmentalised cubical type, extens ible on either side and shall be treated with all anticorrosive process before painting with two coats of zine chromate primer & final appd shade of enamel paint.

-

-

-

... More
Busbars shall be of continuous rated Al adequate for speciifed rated continuous & short circuit current covered by, proper graded heat shrinkable PVC sleeves (colour coded). Busbars shall be supported by suitable hylaml/ DMC/ SMC or compatable ins ulator supports. HIgh tensile bolts & springs washers are to be provided on all busbars and suitable drilled holes for connection joints. The busbars shall have a throuth fault withstand capacity of 31 MVA, RMS symmetrical for one second. The interconnections between the busbars & the circuit breakers shall be made by continuous rated Cu/Al strips suitably covered by pro per graded heat shrinkable colour coded PVC sleeves. The earth busbar shall run through the length of the panel & terminated at two ends.

-

-

-

... More
All the MCCBs shall be provided with extended rotary operated mechanism. Safety interlocks are toe be provided to prevent the doors of the compartments housing the MCCBs to prevent the doors to open when the MCCBs are 'ON' position.

-

-

-

... More
Adequate cabling space should be available in the panel with cable supports, cable alleys, etc. Provision for top/ bottom entry & termination of reqd number of XLPE cable shall be provided. The position of control switches, push buttons, levers, etc requiring manual operation shall be at a height not exceeding 1850 mm from the finished floor level. The rate shall also include providing & fixing space heater with thermostat control temperature conlroler incl. connec ting the same with the system with all other accessories viz sockets. etc. reqd. The panel shall also be provided with cubicle illumination lamps as per requirement incl. connecting the same within the panel with all other accesso ries reqd.

-

-

-

... More
The panel shall also comprise of necy meters, CTs, protection MCBs/ HRC fuses, indication lamps relays, lifting bolts, label inscriptions (metalic engraved identi fication tags) describing the rating of the breakers, bus couplers, designation of the feeders etc incl. all other accessories, complete as per IE rules & regulations conforming to relevant IS and duly appd by Client/ Consultant. The rate shall include necy cutting chases, & mending good damages during installation. The panel shall have the following major components.

-

-

-

... More
INCOMER

-

-

-

... More
2 Nos 800A, 4P electrically operated, motorised-cum-manual spring charged withdrawable type ACB of rated service voltage upto 690V, 50 HZ with manual push buttons, indications, current sensors, CTs, etc conforming to the spedfication & as follows:

-

-

-

... More
Icu-50 KA (at 415V, 50 HZ), Ics=100% Icu and Icw not less than 50 KA for 1 Sec.

-

-

-

... More
Microprocessor based S/C, E/F & O/C releases.

-

-

-

... More
Rated impulse withstand voltage not less than 12 KV for main conducting paths.

-

-

-

... More
Auxiliary contacts, shunt trip coils etc.

-

-

-

... More
1 sets- Ground Time Overcurrent Relay (51G) with NCT -250-125/5.

-

-

-

... More
2 sets- CT Operated Digital Multifunction Meter having Cl-1 accuracy & showing (A, V, F, Maximum Demand).

-

-

-

... More
2 Sets- (3 Nos/Set) 800/5-5A Dual Core cast resin type Current Transformer of CL-5P10 for protection & CL-1 for metering with 15VA burden each

-

-

-

... More
2 sets - CT Operated 3 O/C + 1 E/F RELAY having protection class 5P10.

-

-

-

... More
2 Sets- 1KVA control transformer (415/110V) with Automatic change over arrangement & indication lamps.

-

-

-

... More
2 Sets- (3 Nos/Set) - Cast Resin Construction Type Potential Transformer 415 V/√3:110V/√3 with Cl-0.1 accuracy with 100VA burden with HRC fuses at primary & secondary for protection.

-

-

-

... More
1 Set (3 Nos/Set) 800/5A cast resin type Current Transformer of CL-1.0 for APFCR with 15VA burden each

-

-

-

... More
2 sets (3 nos each) RYB cluster type LED phase indlcation lamps.

-

-

-

... More
2 sets (7 nos each) - SPRING CHARGED/TEST/ON/OFF/TRIP /TRIP CKT HEALTHY cluster type LED indication lamps.

-

-

-

... More
1 sets - Line Voltage Monitoring Module.

-

-

-

... More
BUSBAR

-

-

-

... More
1 sets - 800A, 415V, 50HZ, 31 MVA symmetrical continuous rated cu busbars (50mm X 10mm) for phases & (50mm X 8mm) for neutral mounted on suitable hylam/DMC/SMC insulators/supports with proper graded colour coded heat shrinkable PVC sleeves.

-

-

-

... More
OUTGOING

-

-

-

... More
a) 1 No 63A, 4P MCCBs of rated service voltage upto 440V. Icu=36KA Ics=100% Ieu at 415V, 50HZ with thermo-magnetic based O/L & S/C releases incl. extended rotary operated mechanism, shunt trip coils. Auxiliary contacts, spreaders, etc as necy.

-

-

-

... More
b) 4 No 160-200A, 4P MCCBs of rated service voltage upto 440V. Icu=36KA Ics=100% Ieu at 415V, 50HZ with thermo-magnetic based O/L & S/C releases incl. extended rotary operated mechanism, shunt trip coils. Auxiliary contacts, spreaders, etc as necy.

-

-

-

... More
c) 1 No 320A, 4P MCCBs of rated service voltage upto 440V. Icu=36KA Ics=100% Ieu at 415V, 50HZ with thermo-magnetic based O/L & S/C releases incl. extended rotary operated mechanism, shunt trip coils. Auxiliary contacts, spreaders, etc as necy.

-

-

-

... More
d) 1 No 500A, 4P MCCBs of rated service voltage upto 440V. Icu=36KA Ics=100% Ieu at 415V, 50HZ with thermo-magnetic based O/L & S/C releases incl. extended rotary operated mechanism, shunt trip coils. Auxiliary contacts, spreaders, etc as necy.

-

-

-

... More
e) 2 Sets- 80A SFU with HRC Fuses, handle & LED indication lamps.

-

-

-

... More
f) 1 Set- 32A SFU with HRC fuses, handle & indication lamps.

-

-

-

... More
EARTH BUSBAR

-

-

-

... More
1 Set - 50 mmX10 mm Al busbar running along the base frame covering entire length of the panel with high tensile bolts, nuts, etc. & number of drilled holes as reqd for earth connection at both ends.

-

-

-

... More
1 No.Danger Board.

-

-

-

... More
AUTOMATIC POWER FACTOR CONTROL PANEL

1

-

797054.5

... More
INCOMING

-

-

-

... More
1No- 415V 500A TP+NL MCCB (36KA) with APFC 8-stage relay, auto/manual switch, delay timer as incom er, CTs, PTs, TRIP indicators & RYB phase indicators,

-

-

-

... More
BUSBAR

-

-

-

... More
1 sets - 500A, 415V, 50HZ, 31 MVA symmetrical continuous rated cu busbars (32mm X 10mm) for phases & (32mm X 8mm) for neutral mounted on suitable hylam/DMC/SMC insulators/supports with proper graded colour coded heat shrinkable PVC sleeves.

-

-

-

... More
OUTGOING

-

-

-

... More
1No-415V 250A HRC Fuse with capacitor duty contactor, 100KVAR reactor & capacitor with ON,OFF indicators,

-

-

-

... More
2Nos-415V 160A HRC Fuse with capacitor duty contactor, 50KVAR reactor & capacitor with ON,OFF indicators,

-

-

-

... More
2Nos-415V 80A HRC Fuse with capacitor duty contactor, 25KVAR reactor & capacitor with ON,OFF indicators,

-

-

-

... More
2Nos-415V 80A HRC Fuse with capacitor duty contactor, 20KVAR reactor & capacitor with ON,OFF indicators,

-

-

-

... More
1Nos-415V 63A HRC Fuse with capacitor duty contactor,10KVAR reactor & capacitor with ON,OFF indicators.

-

-

-

... More
2NO-415V 160 & 80A HRC Fuse - Spare feeders.

-

-

-

... More
GROUND FLOOR PANEL

1

-

468080.5

... More
Supply, delivery at site eraction, testing & commissioning of vertical floor mounting free standing, extensible on either side, compartmentalised cubical type panel board made of 14 SWG (2.04 mm) CRCA MS sheet suitable for 500/415V, 50 HZ, AC, 3 Ph & N system having the following features panel shall be designed to ensure that the weight of the components is adequately supported without deformation or loss in allignment. The doors of the cubicle shall be fitted with dust excluding neoprene gaskets with fastners for proper compression of the gaskets.

-

-

-

... More
INCOMER

-

-

-

... More
1 No 320A, 4P MCCBs of rated service voltage upto 690V. with manual push buttons, indications, current sensors, CTs, etc confoirming to the specification & as follows:

-

-

-

... More
Icu-35 KA (at 415V, 50 HZ), Ics=100% Icu and Icw not less than 36 KA for 1 Sec.

-

-

-

... More
Thermo-magnetic based O/L & S/C releases.

-

-

-

... More
Rated impulse withstand voltage not less than 12 KV for main conducting paths.

-

-

-

... More
Auxiliary contacts, shunt trip coils etc.

-

-

-

... More
1 sets CT Operated Digital Multifunction Meter having Cl-1 accuracy & showing (A, V, F).

-

-

-

... More
1 sets (3 nos each) - ON/OFF/TRIP cluster type LED indication lamps.

-

-

-

... More
1 sets - Line Voltage Monitoring Module.

-

-

-

... More
BUSBAR

-

-

-

... More
1 sets- 400A, 415V, 50HZ, 31 MVA symmetrical continuous rated cu busbars (25mmX10mm) for phases & (25mmX8mm) for neutral mounted on suitable hylam/ DMC/SMC insulators/ supports with proper graded colour coded heat shrinkable PVC sleeves. Surge protection device with MPCB with rated KA.

-

-

-

... More
OUTGOING

-

-

-

... More
a) 16 No 63A, 4P MCCBs of rated service voltage upto 690V. with manual push buttons, indications, current sensors, CTs, etc confoirming to the specification and as follows:

-

-

-

... More
b) 4 No 32A, 4P MCCBs of rated service voltage upto 690V. with manual push buttons, indications, current sensors, CTs, etc confoirming to the specification and as follows:

-

-

-

... More
c) 3 Nos - 6-32A DP MCB of rated service voltage upto 240V, Icu=10KA, Ics = 100% Icu at 220V 50 HZ, with thermomagnetic based O/L & S/C releases.

-

-

-

... More
EARTH BUSBAR

-

-

-

... More
1 Set - 25 mm X 8 mm Al busbar running along the base frame covering entire length of the panel with high tensile bolts, nuts, etc. & number of drilled holes as reqd for earth connection at both ends.

-

-

-

... More
1 No.Danger Board.

-

-

-

... More
1ST & 2ND FLOOR PANEL

2

-

221365.68

... More
Supply, delivery at site eraction, testing & commissioning of vertical floor mounting free standing, extensible on either side, compartment alised cubical type panel board made of 14 SWG (2.04 mm) CRCA MS sheet suitable for 500/415V, 50 HZ, AC, 3 Ph & N system having the following features panel shall be designed to ensure that the weight of the components is adequately supported without deform ation or loss in allign ment. The doors of the cubicle shall be fitted with dust excluding neoprene gaskets with fastners for proper compression of the gaskets.

-

-

-

... More
INCOMER

-

-

-

... More
1 No 160A, 4P MCCBs of rated service voltage upto 690V. with manual push buttons, indications, current sensors, CTs, etc confirming to the specification & as follows:

-

-

-

... More
Icu-35 KA (at 415V, 50 HZ), Ics=100% Icu and Icw not less than 36 KA for 1 Sec.

-

-

-

... More
Thermo-magnetic based O/L & S/C releases.

-

-

-

... More
Rated impulse withstand voltage not less than 12 KV for main conducting paths.

-

-

-

... More
Auxiliary contacts, shunt trip coils etc.

-

-

-

... More
1 sets CT Operated Digital Multifunction Meter having Cl-1 accuracy and showing (A, V, F).

-

-

-

... More
1 sets (3 nos each) RYB cluster type LED phase indlcation lamps.

-

-

-

... More
1 sets (3 nos each) - ON/OFF/TRIP cluster type LED indication lamps.

-

-

-

... More
1 sets - Line Voltage Monitoring Module.

-

-

-

... More
BUSBAR

-

-

-

... More
1 sets- 200A, 415V, 50HZ, 31 MVA symmetrical continuous rated cu busbars (20mmX8mm) for phases & (20mm X 6mm) for neutral mounted on suitable hylam/ DMC/SMC insulators/ supports with proper graded colo ur coded heat shrinkable PVC sleeves. Surge protection device with MPCB with rated KA.

-

-

-

... More
OUTGOING

-

-

-

... More
a) 6 No 63A, 4P MCCBs of rated service voltage upto 690V. with manual push buttons, indications, current sensors, CTs, etc confirming to the spedfication & as follows:

-

-

-

... More
b) 1 No 32A, 4P MCCBs of rated service voltage upto 690V. with manual push buttons, indications, current sensors, CTs, etc confirming to the spedfication & as follows:

-

-

-

... More
EARTH BUSBAR

-

-

-

... More
1 Set - 25 mm X 8 mm AL busbar funning along the base frame covering entire length of the panel with high tensile bolts, nuts, etc. & number of drilled holes as reqd for earth connection at both ends.

-

-

-

... More
1 No.Danger Board.

-

-

-

... More
LIFT PANEL (AT LIFT M/C ROOM)

2

-

46055.11

... More
Supply, delivery at site eraction, testing & commissioning of vertical wall mounting free standing, compartmentalised cubical type panel board made of 14 SWG (2.04 mm) CRCA MS sheet suitable for 500/415V, 50 HZ, AC, 3 Ph & N system having the following features panel shall be designed to ensure that the weight of the components is adequately supported without deformation or loss in allignment. The doors of the cubicle shall be fitted with dust excluding neoprene gaskets with fastners for proper compression of the gaskets.

-

-

-

... More
INCOMER

-

-

-

... More
1 No - 63A 4P MCCB of rated service voltage upto 440, Icu= 36KA, Ics = 100% Icu at 440V, 50HZ, with thermo-magnetic based O/L & S/C releases etc as necy.

-

-

-

... More
Rated impulse withstand voltage not less than 12 KV for main conducting paths.

-

-

-

... More
Auxiliary contacts, shunt trip coils etc.

-

-

-

... More
1 set Volt & Ampere meter with selector switch.

-

-

-

... More
1 set (3 nos each) RYB cluster type LED phase indlcation lamps.

-

-

-

... More
1 set (3 nos each) - ON/OFF/TRIP cluster type LED indication lamps.

-

-

-

... More
BUSBAR

-

-

-

... More
1 set-100A, 415V, 50HZ, 31 MVA symmetrical continuous rated Al busbars (1X20mmX6mm) for phases & (1X20mmX6mm) for neutral mounted on suita ble hylam/DMC/SMC insulators/supp orts with proper graded colour coded heat shrinkable PVC sleeves. Surge protection device with MPCB with rated KA.

-

-

-

... More
OUTGOING

-

-

-

... More
a) 2 Nos - 63A 4P MCB of rated service voltage upto 415V.

-

-

-

... More
a) 1 No - 16A DP MCB of rated service voltage upto 230V.

-

-

-

... More
EARTH BUSBAR

-

-

-

... More
1 Set - 32 mm X 6 mm GI busbar running along the base frame covering entire length of the panel with high tensile bolts, nuts, etc. & number of drilled holes as reqd for earth connection at both ends.

-

-

-

... More
1 No.Danger Board.

-

-

-

... More
SFU/FSU WITH ENCLOSER

-

-

-

... More
S/F 415V, TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S/F 3 nos. DIN type HRC fuse as per rating.

-

-

-

... More
160A, (Siemens or Equivalent)

2

-

9981.3

... More
315/320A, (Siemens or Equivalent)

1

-

17738.7

... More
MV CABLE

-

-

-

... More
Supply of 1.1KV 3C x 2.5 sqmm XLPE Ar Cu cable as directed by EIC.

770

-

124.36

... More
Supply of 1.1KV 3C x 4 sqmm XLPE Ar Cu cable as directed by EIC.

250

-

166.43

... More
Supply of 1.1KV 3C x 6 sqmm XLPE Ar Cu cable as directed by EIC.

510

-

228.14

... More
Supply of 1.1KV 4C x 2.5 sqmm XLPE Ar Cu cable as directed by EIC.

564.96

-

154.28

... More
Supply of 1.1KV 4C x 4 sqmm XLPE Ar Cu cable as directed by EIC.

374.99

-

210.38

... More
Supply of 1.1KV 4C x 6 sqmm XLPE Ar Cu cable as directed by EIC.

1070

-

293.59

... More
Supply of 1.1KV 3.5C x 25 sqmm XLPE Ar Al. cable as directed by EIC.

1259.96

-

189.81

... More
Supply of 1.1KV 3.5C x 95 sqmm XLPE Ar Al. cable as directed by EIC.

349.995

-

481.53

... More
Supply of 1.1KV 3.5C x 150 sqmm XLPE Ar Al. cable as directed by EIC.

60

-

712.47

... More
Supply of 1.1KV 3.5C x 300 sqmm XLPE Ar Al. cable as directed by EIC.

220

-

1371.65

... More
COMPRESSION GLAND

-

-

-

... More
S/F compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC AR cables as below:

-

-

-

... More
For 3 core upto 6 sqmm.

100

-

120.75

... More
For 4 core upto 6 sqmm.

104

-

120.75

... More
For 3½ core upto 25 sqmm.

60

-

159.6

... More
For 3½ core upto 50 sqmm.

4

-

206.85

... More
For 3½ core upto 95 sqmm.

14

-

287.7

... More
For 3½ core upto 150 sqmm.

8

-

322.35

... More
For 3½ core upto 300 sqmm.

16

-

542.85

... More
FINISHING CABLE ENDS

-

-

-

... More
Finishing the end of following XLPE/PVC AR cables by crimping method incl. S/F solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials:

-

-

-

... More
4 core 2.5 sqmm cable

76

-

58.8

... More
4 core 4 sqmm cable

48

-

63

... More
4 core 6 sqmm cable.

60

-

65.1

... More
3½ core 25 sqmm cable.

76

-

115.5

... More
3½ core 50 sqmm cable.

4

-

219.45

... More
3½ core 95 sqmm cable.

14

-

325.5

... More
3½ core 150 sqmm cable.

8

-

455.7

... More
3½ core 300 sqmm cable.

16

-

926.1

... More
SCHEDULE OF RATES FOR LAYING OF XLPE/PVC INSULATED & AR. CABLES

-

-

-

... More
Laying through Masonry Trench

-

-

-

... More
Laying of one cable of 150 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand.

320

-

100.8

... More
Laying of one cable of 300 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trenchwith fine dry sand incl. supplying sand.

360

-

142.8

... More
LAYING ON WALL/SURFACE WITH SADDLES/CLAMPS

-

-

-

... More
Laying of cable 3/4 core 25 sqmm on wall/surface incl. S/F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages & painting.

700

-

63

... More
Laying on Cable Tray

-

-

-

... More
Laying of cable as below, on existing Cable Tray & binding with suitable size GI wire.

-

-

-

... More
Up to 50 sqmm

950

-

11.55

... More
From 70sqmm to 150sqmm

350

-

15.75

... More
Above 150 sqmm

200

-

19.95

... More
Cable Tray

-

-

-

... More
S/F of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S/F 25x25x3 mm angle iron support, GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as reqd. of the following size. Incl. Al painting of MS support.

-

-

-

... More
200x50x1.25mm (18SWG)

347

-

301.35

... More
300x50x1.25mm (18SWG)

273

-

385.35

... More
S/F of perforated GI cable tray bend with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for support ing the cross member incl. S/F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as reqd of the following size. Incl. Al painting of MS support.

-

-

-

... More
200x50x1.25mm (18SWG)

6

-

471.45

... More
300x50x1.25mm (18SWG)

6

-

637.35

... More
S/F of perforated GI cable tray reducer with perforation not more than 17.5% suspended from ceiling with two nos.suspenders & 25x25x3mm angle iron for support ing the reducer incl. S/F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as reqd of the following size. Incl. Al painting of MS support.

-

-

-

... More
300x50x1.25mm (18SWG)

12

-

513.45

... More
SCHEDULE OF RATES FOR EARTHING INSTALLATIONS

-

-

-

... More
Excavation of soft soil for installation of Earth Electrode & filling & ramming.

46

-

225.75

... More
EARTHING INSTALLATION BY GI PIPE – (FOR SUB- STATION NEUTRAL/ EQUIPMENT EARTHING):

-

-

-

... More
Earthing with 65 mm dia GI pipe (TATA-M) x 3 Mts long & 1 No. 50mmx6mm galv (Hot Dip) steel strip (4 Mts long), 20 mm dia x 125 mm long galv. bolt, double nuts, double washers incl. finishing both ends by maki ng holes etc. & S/F 65 mm dia GI pipe (ISI-M) protectio n (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts.

8

-

4061.4

... More
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36cmx86.36cmx46cm deep (below Ground level) complete with cem ented brick work (1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56cmx35.56cm with locking arrange ment, GI reducer incl. drilling of 46 nos. 12 mm dia holes on the GI pipe.

8

-

960.75

... More
Extra for treatment of soil by using salt & charcoal or coke for plate electrode.

8

-

557.55

... More
EARTH BUSBAR:

-

-

-

... More
S/F earth busbar of galv. (Hot Dip) MS flat 50 mmx6 mm on wall having clearance of 6 mm from wall incl. providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as reqd.

450

-

226.8

... More
EQUIPMENT EARTHING:

-

-

-

... More
Connecting the equipments body to earth busbar incl. S/F 25mmx6 mm galv (Hot Dip) MS flat on wall/floor with GI saddles as reqd & connection to equipments incl. drilling holes, with bolts, nuts, washers etc.

150

-

144.9

... More
EARTHING CONNECTION FROM EARTH ELECTRODE TO TRANSFORMER NEUTRAL/ EARTH BUSBAR

-

-

-

... More
Extra for connecting the neutral of Transformer/Earth busbar to earth electrode incl. S/F 50 mm x 6 mm Galv (Hot Dip) steel strip on wall/floor with GI saddles & insulating the same by one layer of PVC strip over one layer of ampere tape.

40

-

235.2

... More
Earth Continuity Conductor :

-

-

-

... More
Connecting the equipments to earth busbar incl. S/F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as reqd & making connection to equipments with bolts, nuts, washers, cable lugs etc. as reqd & mending good damages.

-

-

-

... More
(a) Solid GI wire-No. 6 SWG

1249.9

-

13.65

... More
GI PIPE FOR CABLE PROTECTION

-

-

-

... More
S/L of 32mm dia GI pipe (ISI-M)

30

-

228.9

... More
S/L of 40mm dia GI pipe (ISI-M)

50

-

258.3

... More
S/L of 65mm dia GI pipe (ISI-M)

20

-

436.8

... More
S/L of 80mm dia GI pipe (ISI-M)

50

-

555.45

... More
S/L of 125mm dia GI pipe (ISI-M)

25

-

1009.05

... More
S/F of testing joints by 50mm x 6mm thick G.I. strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thombles at the end of 7/10 SWG G.I. stranded wire & stranded 4 SWG G.I. wire of vertical conductor & conductor from earth electrode complete with S/F thimbles, G.I. bolts, nuts, check-nuts, spring washers etc. as reqd.

18

-

231.86

... More
Cutting cornicles/steps etc. incl. cutting recess in buildings etc. & S/F 15 mm bore (ISI-M) GI pipe protection as below & mending good damages to the damages to the building works.

-

-

-

... More
Length upto 0.5 mtr.

20

-

77.7

... More
Cutting the concrete footpath for placing the earth electrodes & repairing the same with necy cement concrete & finishing the same.

22

-

250

... More
Providing & fixing steel fastener for fixing the G.I. tape on wall (1¼" x ¼")

65

-

10



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.