State Water Investigation Directorate Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

State Water Investigation Directorate - SWID Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date30 Jan 2024
Closing Date7 Feb 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Single brick flat soling of picked jhama bricks including ramming & dressing beds to proper level and filling joints with local sand.

88

31768

361

... More
Hire and labour charges for shoring work (including necessary close plank walling, framing, Eucalyptus/Jhou bulla piling, strutting etc.) complete as per direction of the Engineer-in-Charge for foundation excavation (vertical surface area in contact with supported earth is to be measured.) This item should be executed on specific direction of the Engineer-in-Charge.) a) Depth upto 1.5 metre

76.14

29390

386

... More
(b) For additional depth beyond 1.5 m. and upto 3.00 m

41.33

18141

439

... More
(i) Cement concrete with graded stone ballast (40 mm. size) excluding shuttering. In ground floor and foundation. A) Pakur Varirty (a) 6:3:1 proportion.

10.7

57523

5376

... More
Ordinary Cement Concrete (mix 3 :1.5 :1) with graded stone chips (20 mm.nominal size) excluding shuttering and reinforcement, if any, in ground floor, as per relevant IS code. a) Pakur

56.86

373658

6572.02

... More
Add extra over the rate of ground floor for basement and each additional floor above Ground floor for 4 to 10 (i) Upto 4 thFloor. (for item-6) 1st Floor.

2.68

254

95

... More
Add extra over the rate of ground floor for basement and each additional floor above Ground floor for 4 to 10 (i) Upto 4 thFloor. (for item-6) 2nd Floor.

2.83

537

190

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. (a) Pakur Variety

1.8

10866

6036.78

... More
Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor) (a) Above 25mm to 30mm thick wooden shuttering as per decision & direction of the Engineer-in-charge.

360.11

120638

335

... More
(d) Extra for works beyond the roof of ground floor per additional floor.(i) upto and inclusive 4th (per floor) and in basement (i)1 st Floor.

27.44

493

18

... More
(d) Extra for works beyond the roof of ground floor per additional floor.(i) upto and inclusive 4th (per floor) and in basement (i) 2nd Floor.

30.44

1095

36

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction.(a) For works in foundation, basement and upto roof of ground floor / upto 4m. (i) Tor steel/Mild steel I. SAIL/TATA/RINL

7.14

432601

60580

... More
(b) Extra for works beyond the roof of ground floor / initial 4 m. i) Upto 4th floor roof. (for item no.9) 1st Floor.

3.85

184

48

... More
(b) Extra for works beyond the roof of ground floor / initial 4 m. i) Upto 4th floor roof.( fot item no. 9) 2nd Floor.

4

384

96

... More
125 mm. thick brick work with 1st class bricks in cement mortar (4:1) in ground floor.

52.35

38528

736

... More
Add extra for each additional floor over the rate for ground floor items 12 : (a) Upto 4th floor ( for item no. 10) 1st Floor

6.94

83

12

... More
Add extra for each additional floor over the rate for ground floor items 12 : (a) Upto 4th floor ( for item no.10) 2nd Floor

6.94

166

24

... More
Brick work with 1st class bricks in cement mortar (6:1) (b) In superstructure, ground floor.

2.94

16564

5636

... More
Labour for chipping of concrete surface before taking of plastering.

170

3570

21

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary (ground floor) (excluding cost of chipping over concrete surface) (ii) With 4:1 cement mortar (c) 20 mm. thick plaster.

329.19

63863

194

... More
Add extra for each additional floor over the rate for ground floor items 13 : (a) External plaster(a) Upto 4th floor, 1st floor

40.43

161

4

... More
Add extra for each additional floor over the rate for ground floor items 13 : (a) External plaster(a) Upto 4th floor 2nd Floor

59.12

472

8

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary (ground floor) (excluding cost of chipping over concrete surface) (ii) With 4:1 cement mortar (c) 10 mm. thick celling plaster.

29.56

3931

133

... More
Add extra for each additional floor over the rate for ground floor items 13 : (a) External plaster(a) Upto 4th floor 1st Floor

11

44

4

... More
Add extra for each additional floor over the rate for ground floor items 13 : (a) External plaster(a) Upto 4th floor 2nd Floor

11

88

8

... More
Neat cement punning about 1.5 mm thick in wall dado, window silis, floor, drain etc.

185.18

6296

34

... More
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement (ii) 25 mm. thick

42.25

11534

273

... More
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufactur's specification and as per direction of EIC. In Ground floor (a) one coat

173.57

5450

31.4

... More
Protective and decorative acrylic exterior emulsion paint of approved quality,as per manufacturer specification and as per direction of EIC to be applied over acrylic primer as required the rate includes cost ofmaterial,labour,scaffolding and all incidental chargesbut excluding the cost of primer.In Ground floor(2 coat) a)Normal acrylic emulsion.

173.57

11629

67

... More
(a) M.S. structural works in colum, beams etc. with simple rolled structural members (e.g joists, angel, channel sections conforming to IS:226,IS808& SP(6)-1964 connected to one another with brackets, gussets, cleat5s as per design, direction of Engineer-in-Charge complete including cutting to requisite shape and length, febrication with necessary bolting, metal arc welding conforming to IS 1995 using electrodes of approved make and brand conforming to IS 814-1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such bas electrodes, gas and hire charge of all tools and plants labour required for the work including all incidential charges such as electricity charges, labour insurance charges etc. ( Payment to be made on the basis of calculated weight of structural members only in finished work as per IS specified weight.)

0.67

40626

60276

... More
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smooth ening surfaces by sand papering etc. (This item is applicable to new work or old work when the original surface has been exposed by removal of old paint.

30

870

29

... More
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary b) On steel or other metal surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)

30

2370

79

... More
Supply of approved quality PEA shaped gravel of 2mm to 4mm size ( as per IS:4097) and placeing the same in layers in the recharge pit including scrining washing, cleaning etc. of the gravels at the site complete as per direction of E.I.C.

4.41

11902

2699

... More
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (F)(v) Nipple (300 mm long) 150 mm dia

15

6750

450

... More
(B)Socket 150mm dia

15

4545

303

... More
(C) Elbow 150 mm dia

15

18915

1261

... More
Casing pipes ISI marked - IS 12818 150mm dia 7.5 mm thick Screen Ribbed (Medium) ( Rate included 18% GST)

10

18190

1819

... More
SUPPLYING, FITTINGS & FIXING OF PVC HD-END CAP (PLAIN) AS PER IS 7834 ( HIGH DENSITY) HD-End Cap (Plain) 160 mm

10

4554

455.44

... More
uPVC Fittings ISI marked -IS 10124 ( Rate included 18% GST) 160 mm coupler

3

654

218

... More
Supplying, Fitting & Fixing of Water Storage tank of Approved quality with closed top with lid (Black) - Multilayer as per IS: 12701 (b)1000 litre capacity.

9

46152

5128

... More
Labour for hoisting plastic water storage tank.(ii) Upto 1500 litre capacity Upto 1st story from G.L.

9

864

96

... More
(b) Extra for each additional story. 1st Floor.

6

258

43

... More
2nd floor

3

258

86

... More
Supply of UPVC pipes marked - I S 4985 (Rate included 18% GST) (i)160mm dia Class-II

102

64362

631

... More
(ii) 110 mm dia Class-II

84

23856

284

... More
uPVC Fittings ISI marked - I S 10124 (Rate included 18% GST) a) 160 mm coupler

18

3924

218

... More
b) 110 mm couplar

15

1005

67

... More
c) 110mm TEE

12

4164

347

... More
d) 110 mm dia 90 degree bend

6

2268

378

... More
e) 160x140 Reducer

2

656

328

... More
f) 140x110 Reducer

2

566

283

... More
(g) 110 mm End Cap

4

920

230

... More
SUPPLYING, FITTINGS & FIXING OF SUPPLING, FITTINGS & FIXING OF PVC HD ELBOW (EQUAL) AS PER I S : 7834 a) HD-Elbow (Equal) 160 mm 90°

16

12492

780.76

... More
b) HD-Elbow (Equal) 110 mm 90°

10

4752

475.25

... More
SUPPLYING, FITTINGS & FIXING OF PVC HD -END CAP (PLAIN) AS PER IS 7834 (HIGH DENSITY) HD-End Cap (Plain) 160 mm

4

1821

455.44

... More
SUPPLYING, FITTINGS & FIXING OF PVC HD- REDUCING TEE AS PER IS 7834 (HIGH DENSITY) HD-Reducing Tee 160 x 110 x 160 mm

16

13276

829.8

... More
SUPPLYING, FITTINGS & FIXING OF PVC HD-TEE (EQUAL) AS PER IS 7834 (HIGH DENSITY) HD-Tee (Equal) 160 mm

6

5521

920.32

... More
Supply of UPVC pipes (B-Type) & fittings conforming to I S 13592 - 1992. a)90 Door Bend (TS) 160mm

5

1845

369

... More
b) Vent Cowl 160mm

12

684

57

... More
c) Pipe Clip 160mm (102/2=51)

60

2580

43

... More
d) Pipe Clip 110mm

50

1050

21

... More
Labour charges for fitting and fixing high density polythene pipes or PVC pipes for above ground work including cost of jointing meterials, paints etc. fitting & fixing all necessary specials, cutting pipes, making threads, cutting holes in wall or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamp (any floor) or for underground works including cutting trenches up to 1.5 metre and filling the same complete as per direction of EIC. (payment will be made on centre line measurment of the total pipe line including specials) ii) 110mm OD

84

4872

58

... More
ii) 160mm OD

102

7650

75

... More
Supplying , fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD-1785 and threaded to match with GI pipes as per IS: 1239 (part-I) with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, erducing socket, reducing tee, short piece etc. fitted with holder bats clamp, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittingdn as required, joining materials and two coars of painting with approved paint in any position above ground, (Payment will be made on the center line measurment of total pipe line including all specials. No seperate payment will be made for accessories, specials. Payment for painting will be made seperately) 50mm dia PVC

80

30720

384

... More
Supplying, fitting and fixing of G.M. Gate Valvel Throttle Valve as per IS:778. G. M. Valve 1"

3

3818

1272.98

... More
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder batsclamps, including cutting pipes, making hreads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as equired,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all pecials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) For Exposed Work PVC Pipes (Dia) (a) 15 mm

50

5050

101

... More
(b) 25 mm

150

26550

177

... More
(c) 40 mm

30

8760

292

... More
(d) 50 mm

90

34560

384

... More
Supply of 1" dia Garden pipe ( 30 mtr. Roll) (Rate taken from Internet. Saha agro Agency)

30

900

30

... More
Chromium plated angular stop cockwith wall flange (Equivalent to Code No.5053 & Model-Florentine of Jaguar or similar brand).

10

8150

815

... More
Chromium plated Bib Cock long body with wall flange with aerator (Equivalent to Code No.512 & Model-Tropical/ Sumthing Special of ESSCO or similar brand.

10

6590

659

... More
Construction of Canopy / Placard made of angle, flat, sheet, including printing & painting etc. including making of emblem all complete as per direction.

2

15080

7540

... More
Supply of 2HP Centrifugal Water pump Pump (Model-Crompton MIKH22-27 2HP Centrifugal Water Pump)

1

19800

19800

... More
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC

30

4470

149

... More
Supply & Fixing 240 V, 25A Modular type socket, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.

1

1047

1047

... More
Add GST(CGST+SGST -@9% each) 18% Except item no. 24,26,30.1, 30.2 & (31.1- 31.7)

1

292931

292931.08

... More
Add Labour welfare cess @ 1% of Total amount.

1

20408

20408.91



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.