South Eastern Railway Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

South Eastern Railway - SER Tender

Works
Electrical and Electronics
Electrical Works
Ireps
Opening Date13 Jan 2025
Closing Date4 Feb 2025
Tender Amount₹ 47,60,057.47 
Notes
Download

Costs

Summary

Electrical Estimate For"renovation Of Wcd And Provision Of Pit At Wcd1 At Santragachi Coaching Depot."

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
"Supply of Cable loop box ( of fibre body) for 3-Phase in- coming and out going 5 connection consists of 3-Phase and neutral terminal and 15 Amps K-fuse as per relevant ISS, with suitable bridge arrange- ment of size : 240mm X 140mm x 100 mm.,as per relevent specification/drawing. Fixing shall be made with necessary arrangements as per site requirement, cables are to be terminated with proper socketing arrangement to complete job.

100

635

63560

... More
Fixing and commissioning of Cable loop box ( of fibre body) for 3-Phase in- coming and 6 out going connection consists of 3-Phase and neutral terminal and 15 Amps K-fuse as per relevant ISS, with suitable bridge arrange- ment of size : 240mm X 140mm x 100 mm.,as per relevent specification/drawing. Fixing shall be made with necessary arrangements as per site requirement, cables are to be terminated with proper socketing arrangement to complete job.

100

67

6750

... More
"Supply of Earthing arrangement with supply of earth cone and all other requisite 7 materials as per CEE/GRC's Drg. No.CEE/G/A-3/P-150 including sump box with salt and charcoal,metalic cover etc.Cost also includes supply and connection of 35X3 SWG GI strip between earth pole and main switch/DB/Rail pole etc. as per site supervisor's instruction. Cost also includes earth clamp of size 50X6mm GI and testing of earth resistance.

22

1305

28727.38

... More
Erection of Earthing arrangement with commissioning of earth cone and all other 8 requisite materials as per CEE/GRC's Drg. No.CEE/G/A-3/P-150 including sump box with salt and charcoal,metalic cover etc.Cost also includes connection of 35X3 SWG GI strip between earth pole and main switch/DB/Rail pole etc. as per site supervisor's instruction. Cost also includes connection of earth clamp of size 50X6mm GI and testing of earth resistance.

22

628

13819.3

... More
Laying of cable / cables in under ground along the road through cable trench etc . as per standard drawing including necessary termination , connection and testing.Trenching and laying 09 of U/G cables in any kind of soil trench of size minimum 0.40 mtr wide and 1 mtr deep covered with necessary bricks for protection of the cables including filling of space between brick and cable/cables with sand and refilling the trench with excavated soil, leveling up, and restoring the surface duly rammed.

800

102

82312

... More
Laying of cable / cables across the road, track, drain etc through RCC/GI pipe 10 confirming to IS standard of size 100mm or 150mm (or any suitable size as per field requirement based on the actual size of the cable) as per relevant specification and as per standard drawing with necessary termination, connections and testing .Cost also includes collection of cable/cables from Railway store if required.GI pipe will be supplied by contractor.

300

243

73176

... More
Laying of cable/ cables on wall / structure through PVC casing pipe of size 4inches or 11 3inches with accessories or as per site requirement with suitable clamp / saddle/ fixtures etc with necessary termination, connection and testing as per standard drawing.Cost also includes collection of cable/cables from Railway store if required.

600

67

40626

... More
Boring/punching of underground crossing of Railway track/road with pipe pushing by HDD technology & crossing HT/LT power cable below railway track/road through pipe.

800

1000

800160

... More
Supply of 4 pole copper bus bar of 100A capacity in suitable enclosure. Similar to Havells IHBC010004. 14

8

8152

65217.84

... More
Fixing and Installation of 4 pole copper bus bar of 100A capacity in suitable enclosure.

8

407

3260.88

... More
Supply of 4 pole copper bus bar of 63A capacity in suitable enclosure. similar to HavellsIHBC006304. 16

8

6790

54321.44

... More
Fixing and Installation of 4 pole copper bus bar of 63A capacity in suitable enclosure.

8

339

2716.08

... More
"Supply of Analog Time Switches 3 module for Tower Light, Pump Installations & Street Light Circuits etc. Floor/Panel/Tower/Wall mounted ,Supply Voltage 240V AC,50/60HZ,with FP 63A 17 10kA MCB - 01 Nos as incoming, FP 63A power contractor with oveload protection - 1 Nos.and 63A,10kA DP MCB-02no , timer switch,suitable for auto/manual operation with SS enclosure , indicator with protection for timer, with terminal stud connector 60-63A -2 Nos and proper wiring to complete job.

4

10301

41204.36

... More
Fixng and Commissioning o f Analog Time Switches 3 module for Tower Light, Pump Installations & Street Light Circuits etc. Floor/Panel/Tower/Wall mounted ,Supply Voltage 240V 18 AC,50/60HZ,with FP 63A 10kA MCB - 01 Nos as incoming, FP 63A power contractor with oveload protection - 1 Nos.and 63A,10kA DP MCB-02no , timer switch,suitable for auto/manual operation with SS enclosure , indicator with protection for timer, with terminal stud connector 60-63A -2 Nos and proper wiring to complete job.

4

1030

4120.4

... More
Supply of All in one work station 27'' FHD, Ryzen-7, 4700U, 16GB RAM, 1TB SSD, WINDOWS-10/11 -with All in one multi-function printer (Print, Scan, copy) A4 Mono Laser. 20

-

-

19

... More
Supply, of LED Street light fittings 70 W LED, IP-65/66.

20

3050

61017

... More
Fixing and commissioning of LED 70watt or higher wattage street light including wiring of light from loop box.

20

154

3085

... More
Supply of True RMS Digital Clamp Meter (Minimum resistance measurement range: 4 Kohm, AC current range: 1000 amps, DC current range 1000 amps, AC voltage750 v, DC voltage 1000 V) . 23

1

5071

5071.23

... More
"Supply of HDPE pipe of size 75mm Dia to complete job. 24

1000

144

144920

... More
Erection and commissioning of HDPE pipe of size 75mm dia to complete job.

1000

14

14490

... More
Supply, of 4 POLE 25 KA 140 AMPS MCCB fixed overload and fixed short circuit, extended terminal fitted in SS enclosure. 26

5

8130

40650

... More
Fixing and Commissioning of 4P, 160Amps, with sheet steel enclouser.

5

586

2933.65

... More
Supply of industrial, insulated plug and sockets , rating -32 amps , 5 pin , 3P + N+ E , fixed in box suitable to provided to wall /structures equivalent in dimensions to make- Havells and model -DHDPBEN032, MCB module to be available ,Earth -contact position -6h. it shall have the MCB 27 ,32 amps , 4 pole, fixed in the module available in the plug and socket box . It shall be capable to withstand the power supply of 3 phase , 440 V , 50 Hz , 5 wire system . ( RYB phases , neutral and earth pin ) . The plug and sockets shall be of easy fixing and removing type and have locking system after inserting and rotating. It shall have the provision of cap to female socket which closes the socket automatically after removing the plug. It shall have the IS specification IS 1293(2005).

50

2160

108000

... More
"Fixing and Commissioning of industrial, insulated plug and sockets , rating -32 amps , 28 5 pin , 3P + N+ E , fixed in box suitable to provided to wall /structures equivalent in dimensions to make- Havells and model -DHDPBEN032, MCB module to be available ,Earth -contact position -6h. it shall have the MCB ,32 amps , 4 pole, fixed in the module available in the plug and socket box . It shall be capable to withstand the power supply of 3 phase , 440 V , 50 Hz , 5 wire system ."

50

108

5400

... More
"Supply Fixing and Commissioning of 125 A 3 Phase Precooling station made of Polycarbonate enclosure (shock proof, rust free, corrosion free, acid and chemical resistant, fire retardant, having high impact, made of halogen and silica free recyclable material), UV resistant, having high grade gasket made of Polyurethane, should withstand glow wire test Glow wire test as per IEC 60695-2-11: 960 °C, should be flame retardant, degree of Protection IP 65, Degree of protection. Dimension of Precooling station 500x1051x425mm fitted with1 no. Industrial socket & 29 plug must be IP67 insulated 125 A , 5 pin (3P +E+N) made of high quality polyamide P-6 body shock proof ,rust free, corrosion free, acid and chemical resistant, fire retardant having high impact proof, made of halogen and silica free recyclable materialand terminal contact solid high quality turned contacts made of copper alloy(brass). There will be a 125A FP 25 kA MCCB. For avoiding condensation or formation of water droplets inside the welding receptacle, measures must be taken following safety standard IEC 60364-5-52 using Passive Solutions. Mounting Type : Wall Mounting/outdoor Cable Entry : Bottom System Voltage415V, 50Hz, 4Wire+EOutgoing 125A FP 25KA MCCB- 1No 125A 5P IP67 Plug&Socket- 1No. 30

8

66900

535200

... More
Supply of Multifunction Machine with Wi-Fi connectivity and onsite warranty 03 years.

2

36227

72455.94

... More
Supply Erection, Commissioning & installation of Feeder Pillar made of Polycarbonate made (shock proof, rust free, corrosion free, acid and chemical resistant, fire retardant, having high impact, made of halogen and silica free recyclable material), UVresistant, having high grade gasket made of Polyurethane, should withstand glow wire test at 9600c, should be flame retardant, for avoiding condensation or formation of water droplets inside the feeder pillar. For that moisture absorbent material made of synthetic rubber, super absorbent polymer and nonwoven fabric which should have absorbency of 0.8g (H2O)/1g (product) @ 25deg C and 95% RH or Higher. The feeder pillar panel should hold Type Test certificate(CPRI)with switchgear assemblies as per IEC61 439- 1.Mounting Type : Floor MountingCable Entry : Bottom, System Voltage 415V, 50Hz, 4Wire+E Busbar Rating200A (RYBN-25X10)mm Cu. Incoming 200A FP 25KA MCCB- 1No, Outgoing 100A FP 25KA MCCB- 2Nos, 63A FP 25KA MCCB- 2Nos, 63A FP 10KA MCB- 1No,63/75A FP Contactor- 1No, 24Hrs Analog Timer- 1No,32A DP 10KA MCB- 4Nos, Start Push Button With 1NO(Green)- No Stop Push Button With 1NC(Red)- 1NoON LED Indication Lamp(Red)- 1NoOFF LED Indication Lamp(Green)- 1NoControl Fuse With Base- 1No 32

-

-

31

... More
GST @ 18% on the sub-total (Supply+Erection)

-

-

632082.85

... More
Supply of 20W or higher wattage LED tube light with Batten ( integrated electronic driver).As per CEGE approved Specification for LED tube light-high power,2100 Lumen output,220V, 50Hz AC, 6500 K with constant current driver with short circuit and overload protection etc. 2

20

457

9152.6

... More
Fixing and Commisioning of 20W or higher wattage LED tube light with Batten 3

20

40

811.8

... More
Supply, of LED Street light fittings 45W LED, IP-65/66.

2

2352

4705.08

... More
Fixing and commissioning of LED 45 watt or higher wattage street light including wiring of light from loop box. 5

2

154

308.5

... More
Supply of Single phase propeller type Exhaust Fan, 4-pole, 300mm size. 6

2

2118

4237.28

... More
Fixing and commissioning of Heavy Duty Exhaust Fans as per consignee requirement.

2

129

259.1

... More
Supply of switch socket board ( Power), shutter type 15/5 Amps 5-pin socket /15 Amps switch on a MS board/TW board with phenolic cover.

10

95

953.7

... More
Fixing and commissioning of switch socket board ( Power), shutter type 15/5 Amps 5- pin socket /15 Amps switch on a MS board/TW board with phenolic cover.

10

19

197

... More
"Supply of concealed PC Board consisting with 03 nos switch socket unit 06 Amps capacity with fuse indicator lamp and internal wiring.with 8M GI Box size 5X5 inch.

6

224

1347.42

... More
Fixing and commissioning of concealed PC Board consisting with 03 nos switch socket unit 06 Amps capacity with fuse indicator lamp and internal wiring.with 8M GI Box size 5X5 inch.

6

26

158.94

... More
Supply of BLDC CEILLING FAN WITH REMOTE control with 5 STAR and above RATING 1400 mm size, down rod etc., suitable for 230V, 50Hz, AC supply as per site requirement.

10

2821

28211.9

... More
Fixing and commissioning of CEILLING FAN WITH REMOTE control WITH 5 STAR and 12 above RATING 1400 mm size suitable for 230V, 50Hz, AC supply confirming to Class:I of IS: 374/latest. Fixing of the fan shall be done with suitable clamp, hook, nut/bolts etc. and connection with flexible twin twisted multistrand Copper wire and removing of the existing old fan (if any) and handing over of the same to Railway Store with clear acknowledgement, as per site requirement.

10

116

1162.2

... More
Supply of PVC Circular Box and Ceiling rose with connection 1.5 Sq.mm PVC wire from running circuit ( 2.5 Sq.mm PVC wire) as per direction of Consignee.

30

19

584.7

... More
Fixing and Commissioning of PVC Circular Box and Ceiling rose with connection 1.5 Sq.mm PVC wire from running circuit( 2.5 Sq.mm PVC wire) as per direction of Consignee

30

1

58.5

... More
"Supply of Cable loop box ( of fibre body) for 3-Phase in- coming and out going 15 connection consists of 3-Phase and neutral terminal and 15 Amps K-fuse as per relevant ISS, with suitable bridge arrange- ment of size : 240mm X 140mm x 100 mm.,as per relevent specification/drawing. Fixing shall be made with necessary arrangements as per site requirement, cables are to be terminated with proper socketing arrangement to complete job.

5

635

3178

... More
Fixing and commissioning of Cable loop box ( of fibre body) for 3-Phase in- coming and 16 out going connection consists of 3-Phase and neutral terminal and 15 Amps K-fuse as per relevant ISS, with suitable bridge arrange- ment of size : 240mm X 140mm x 100 mm.,as per relevent specification/drawing. Fixing shall be made with necessary arrangements as per site requirement, cables are to be terminated with proper socketing arrangement to complete job.

5

67

337.5

... More
"Supply of VTP&N 4-way DB (SD) consisting with FP 63A 10kA MCB-1 no as incoming and DP 32 A,10kA MCB - 6 nos as outgoing with Cu.bus-bar, Neutral links and Earth bar etc.,

2

11379

22759.28

... More
Fixing and Commisioning of VTP&N 4-way DB (SD) consisting with FP 63A 10kA MCB-1 no as incoming and DP 32 A,10kA MCB - 6 nos as outgoing with Cu.bus-bar, Neutral links and Earth bar etc.,

2

1137

2275.92

... More
"Supply of VTP&N 4-way DB (SD) consisting with FP 125A 25kA MCCB-1 no as incoming and SP 32 A,10kA MCB - 12 nos as outgoing with Cu.bus-bar, Neutral links and Earth bar etc.,

1

16655

16655.33

... More
Fixing and Commisioning of VTP&N 4-way DB (SD) consisting with FP 125A 25kA MCCB-1 no as incoming and SP 32 A,10kA MCB - 12 nos as outgoing with Cu.bus-bar, Neutral links and Earth bar etc.,

1

1665

1665.53

... More
"Supply of SP&N 8-way DB (SD) consisting with DP 40A 10kA MCB-1 no as incoming and SP 20 A,10kA MCB -6 nos as outgoing with Cu.bus-bar, Neutral links and Earth bar etc.,with proper wiring to complete job.

2

2855

5711.18

... More
Fixing and Commisioning of of SP&N 8-way DB (SD) consisting with DP 40A 10kA MCB- 1 no as incoming and SP 20 A,10kA MCB -6 nos as outgoing with Cu.bus-bar, Neutral links and Earth bar etc.,with proper wiring to complete job.

2

285

571.12

... More
Laying of cable / cables in under ground along the road through cable trench etc . as per standard drawing including necessary termination , connection and testing.Trenching and laying 23 of U/G cables in any kind of soil trench of size minimum 0.40 mtr wide and 1 mtr deep covered with necessary bricks for protection of the cables including filling of space between brick and cable/cables with sand and refilling the trench with excavated soil, levelling up, and restoring the surface duly rammed.

350

102

36011.5

... More
Laying of cable / cables across the road, track, drain etc through RCC/GI pipe 24 confirming to IS standard of size 100mm or 150mm (or any suitable size as per field requirement based on the actual size of the cable) as per relevant specification and as per standard drawing with necessary termination, connections and testing .Cost also includes collection of cable/cables from Railway store if required.GI pipe will be supplied by contractor.

50

243

12196

... More
Laying of cable/ cables on wall / structure through PVC casing pipe of size 4inches or 25 3inches with accessories or as per site requirement with suitable clamp / saddle/ fixtures etc with necessary termination, connection and testing as per standard drawing. Cost also includes collection of cable/cables from Railway store if required.

100

67

6771

... More
Supply of Maintenance Free Earthing system (Pipe in pipe technology) complete with suitable size Mild steel Earth pipe, Back fill compound etc.

2

9555

19110.4

... More
Erection of Maintenance Free Earthing system (Pipe in pipe technology) complete with suitable size. Mild steel Earth pipe, Back fill compound etc.

2

3356

6713.22

... More
Supply of 19 mm X 6 mm GI strip for proper earthing of Maintenance Free Earthing System.

60

72

4362.6

... More
Laying & Connection of 19 mm X 6 mm GI strip for proper earthing of Maintenance Free Earthing System.

-

-

29

... More
Point Wiring by PVC conduit /PVC Casing & Capping : -- Internal wiring for light, fan , plug points and night lamp points by 1.5 sq.mm Cu. cable, 660 Volt grade, make - M/s.Polycab,M/s.Finolex,M/s.Havell's,M/s.Anchor through PVC conduit pipe of (25 mm dia and 1.5 mm thickness/PVC Casing & Capping of thickness 1.2 mm), make-Kalinga/Presto plast/Precission and 30 piano type switches, batton holder, ceiling rose, sockets to be provided as and where required as per direction of consignee on phenolic covered switch board of suitable size with continuous earthing by 14 SWG tinned Cu. wire / by 1 Sq.mm PVC Cu wire (Provision of fan regulator should be kept on switch board) *Each switch board should contain flash type fuse of 5A capacity. *All switches, batton holder, ceiling rose, 5A socket etc. will be make of M/s.Anchor,M/s.Goldmedal ,M/s.Crabtree conforming to IS approved reputed brand.( Two 5-ampere socket point treated as one point),Two blank space is required in each modular switch board.

60

422

25357.2

... More
Circuit/Sub-circuit wiring by PVC conduit/PVC casing capping wiring by 2.5 sq.mm Cu.cable, 660 Volt grade make- M/s.Polycab,M/s.Finolex,M/s.Havell's,M/s.Anchor through PVC conduit (25 mm dia and 1.5 mm thickness/PVC Casing & Capping of thickness 1.2 mm) make-Kalinga/Presto 31 plast/Precission and continuous earthing by 14 SWG tinned Cu. wire/1 Sq. mm PVC Cu. wire to be provided as and where required as per direction of consignee. *Quantity per meter means-one meter conduit with 2 (two) meters Cu. cable & 1mtr of 14 SWG tinned Cu. wire/1.5Sq.mm PVC Cu. as earthing with Supply of PVC Circular Box and Ceiling rose with connection 1.5 Sq.mm PVC wire from running circuit ( 2.5 Sq.mm PVC wire) as per direction of Consignee.

250

65

16352.5

... More
Circuit/Sub-circuit wiring by PVC conduit/PVC casing capping wiring by 4 sq.mm Cu.cable, 660 Volt grade make-M/s.Polycab,M/s.Finolex,M/s.Havell's,M/s.Anchor through PVC conduit 32 (25 mm dia and 1.5 mm thickness/PVC Casing & Capping of thickness 1.2 mm) make-Kalinga/Presto plus/Precission and continuous earthing by 14 SWG tinned Cu. wire/2.5 Sq. mm PVC Cu. wire to be provided as and where required as per direction of consignee . *Quantity per meter means-one meter conduit with 2 (two) meters Cu. cable & 1mtr of 14 SWG tinned Cu. wire.

100

78

7839

... More
Concealed Sub circuit wiring by 6 Sq mm PVC wire with 2.5 Sq mm earthing wire of PVC CU wire through 20 mm dia PVC conduit pipe/casing capping .

25

129

3229.5

... More
Supply of capacitor bank 25 KVAR Capacitor bank 25 KVAR capacity.( heavy duty resin filled capacity 440v ). 35

2

2768

5537.28

... More
GST @ 18% on the sub-total (Supply+Erection)

-

-

44948.95

... More
Laying, testing, drawl & commissioning of HT cable. The price shall cover all requisite materials, digging of cable trench in any kind of soil, supply and spreading's and for cable 1 commissioning, supply and laying of bricks (Class- A) along the road as per site requirement & CEE/GRC's drg. No. CEE/G/A-3/P-134.Price shall also cover for filling up the trench with soil after completion of work including cable marker for proper tracing of cable.Cost also includes collection of cable/cables from Railway store and supply of PVC sleeve/Pipe (or any suitable size as per field requirement based on the actual size of the cable)

210

165

34654.2

... More
Laying of HT cable / cables across the road, track, drain,concrete etc through HDPE/GI/RCC pipe confirming to IS standard of size 100mm (or any suitable size as per field 2 requirement based on the actual size of the cable) as per relevant specification and as per standard drawing with necessary termination, connections and testing .Cost also includes collection of cable/cables from Railway and supply of GI/RCC pipe confirming to IS standard of size 100mm (or any suitable size as per field requirement based on the actual size of the cable)

20

432

8655.4

... More
Laying, testing, drawl & commissioning of HT cable. The price shall cover all requisite 3 for fixing of cables in wall/pole with necessary clamping not more than 50cm apart. For fixing cables on wall, PVC sleeve/Pipe should be used as per site requirement & CEE/GRC's drg. No. CEE/G/A-3/P- 134 including cable marker for proper tracing of cable. Cost also includes collection of cable/cables from Railway store.

20

54

1085.6

... More
Supply of HT Heat shrinkable type End Termination Indoor/Outdoor type suitable for 3 x 240-300 Sq mm Screened XLPE cable 11KV/E as per IEC-60502-4 or latest.

-

-

4

... More
Fixing and Commissioning of HT Heat shrinkable type End Termination Indoor/outdoor type suitable for 3 x 240-300 Sq mm Screened XLPE cable 11KV/E.

4

771

3084.12

... More
Erection, testing and commissioning HT VCB 6.6 KV 2 X 400 amps of 2 panel (01 as 6 incoming, 01 as outgoing) with copper busbar all metering arrangement and relevant accessories conforming IS: 3427 & 13118.with battery backed power pack CT ratio 200/5,100 / 5 ,150/5 as per site requirement.

2

37750

75501.12

... More
Supply of Black rubber mats (shock proof) 10mm thickness, size 1mtrx2mtr, working Voltage 0.4 kv , shock proof voltage 15kv ac, dielectric strength 40 kv, anti-skid, design checkered, as per specification: IS -15652-2006.

30

1300

39000

... More
Supply and installation of 20 x 4x 0.5 (L x W x H )(Ft) Glow Sign Boards for sub stations.

2

26402

52805.08

... More
"Supply of Earthing arrangement with supply of earth cone and all other requisite 9 materials as per CEE/GRC's Drg. No.CEE/G/A-3/P-150 including sump box with salt and charcoal,metalic cover etc.Cost also includes supply and connection of 35X3 SWG GI strip between earth pole and main switch/DB/Rail pole etc. as per site supervisor's instruction. Cost also includes earth clamp of size 50X6mm GI and testing of earth resistance.

13

1306

16984.37

... More
Erection of Earthing arrangement with commissioning of earth cone and all other 10 requisite materials as per CEE/GRC's Drg. No.CEE/G/A-3/P-150 including sump box with salt and charcoal,metalic cover etc.Cost also includes connection of 35X3 SWG GI strip between earth pole and main switch/DB/Rail pole etc. as per site supervisor's instruction. Cost also includes connection of earth clamp of size 50X6mm GI and testing of earth resistance. 11

13

668

8685.95

... More
GST @ 18% on the sub-total (Supply+Erection)

-

-

49078.66



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.