Siliguri Jalpaiguri Development Authority Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Siliguri Jalpaiguri Development Authority - SJDA Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date11 Jan 2024
Closing Date25 Jan 2024
Tender Amount₹ 3,72,433 
Notes
Download

Costs

Summary

Nit No. 106/ Engg/ 2023-24 Of Sjda (2nd Call)

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Ordinary Cement concrete(mix 1:1.5:3) M-20 with graded stone chips (20 mm down ) excluding shuttering and reinforcemnet,if any. In ground floor as per IS 456-2000. River Bazree

3.45

16370

4745

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. Ground Floor

0.5

30176

60353.61

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.

3.43

13728

4006

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns,lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of the EIC

47.03

15425

328

... More
Brick work with 1st class bricks in cement mortar (1:4) (a) In foundation and plinth

1.88

9697

5172

... More
Plaster (to wall ,floor,ceiling etc )with sand and cement morter including rounded off or chamferring corner as directed and raking out joints including throatig ,nosing and drip course , scaffolding/staging where necessary b)15 mm thick plaster GF

23.11

3628

157

... More
Neat cement punning about 1.5 mm, thick in wall , dado ,

3

102

34

... More
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of each tile above 0.09 Sq.m (i) Coloured decorative

12.45

13670

1098

... More
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of each tile above 0.09 Sq.m (i) Coloured decorative

3

2709

903

... More
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. II) For Structural Works in Roof Trusses etc. using joists, channels and angles of specified section weighing less than 22.5 kg/ m

1.12

84816

75729

... More
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.

31.4

910

29

... More
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary (b) On steel or other metal surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)

31.4

2480

79

... More
Cement washing including cleaning and smoothening surface thoroughly (cement to be used @15 kg./100 sq.m. of surface for one coat and @25 kg./100 sq.m of surface for two coats): External surface (Ground floor) (b) Two coats (on new works only).

10.66

152

14.29

... More
Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification. In Ground floor: (iii) Two coats.

10.66

522

49

... More
Holding down bolt with nut including 100 x 100 x 6 mm plate washer at bottom fitted complete and packing the hole with cement concrete or cement grout as directed. (ii) 20 mm dia bolt. (a) 300 mm long

20

2820

141

... More
Supplying high density polythene strainer of approved make with adapter conforming to I.S. specifications. (iii) 80 mm dia.

3

2460

820

... More
Supplying,fitting and fixing check valve (horizontal) G.M. tested to 21 kg per sq. cm. (iv) 32 mm

1

1018

1018

... More
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. A) UPVC Pipes: (ii) 110 mm. Dia.

40

10040

251

... More
Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore. (a) For depth upto 150 metre. (iii) 80 mm dia. boring etc.

40

7880

197

... More
Packing annular space between the outside of the housing pipe and the bore with puddled clay balls of approved size as per direction of the Engineer-in-charge with cost of all materials and labour complete

10

4170

417

... More
Supplying, fitting and fixing steel cutter piece upto 450 mm long with sockets. (iii) 75 mm dia

1

403

403

... More
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (a) For Exposed Work (i) CPVC Pipes Class-1, SDR-11 32 mm

40

11320

283

... More
15 mm

25

2650

106

... More
Supplying, fitting and fixing bib cock or stop cock (e) PTMT (Polytetra Bib Cock / Stop Cock ( Prayag or equivalent) 15 mm

6

924

154

... More
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). (vi) 32 mm dia

2

2320

1160

... More
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (b) 1000 litre capacity

2

10256

5128

... More
Labour for hoisting plastic water storage tank. (i) Upto 1500 litre capacity. (a) Upto 1st story from G.L.

2

192

96

... More
Supplying, fitting and fixing chech valve (vertical) G.M. tested to 21 kg per sq. cm. (iv) 32 mm

1

687

687

... More
Supplying, fitting and fixing G.I. cap at top (i) 100 mm

1

139

139

... More
Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required.

1

7538

7538

... More
Labour for punching hole in plastic water storage tank upto 50 mm dia.

4

76

19

... More
Supplying and fixing Sheet steel Main Switches on flat iron frame on wall : 240V DP with fuse on L&N : 16 Amp (Make: HPL)

1

617

617

... More
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required : 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC

10

1273

127.33

... More
Supply and delivery of direct on line ( DOL) strater panel board confonning to ISl3947 and IEC 947 of suitable HP rating for operation in 230V (+ I }yo) AC , single phase , 50Hzl+5yo) comprising of ammeter, voltnreter, thermal overload relay, 2 pole magnetic contactor with in built water Ievel control, under voltage protection, irrdicating lamp. capacitors, on/off push buttons including 5 way connector, wiring with l/1,5 sq. mm PVC insLrlated copper wire. powder coated vermitr proof box of following capacities: 1 H.P. (Relay Range 6-10 Amp.)

1

9147

9147

... More
Fixing only starters (for motor control) on flat iron frame / angle iron frame on wall: Direct on Line starter for motor (upto 5 HP)

1

139

139.1

... More
Supqly and delivery of clear water verticat wet type submersible pump suitable for bore well conforming to IS : 8034 ( and as amended thereaiter ) with standard tuOC fo. potable clear cold water and BEE 3 Star Rated.capable of discharging noted M'/h. against head of water column. The pump shall be directly coupled with a continuous rated2- pole suitable wet type vertical squinel cage induction Toto. conforming to IS : 9253 (and as amended thereafter ), suitable for operation in A-C Single phases 220Y,50H2 (category B motor) Minimum Bore well Dia: 100 mm, 1 HP, No of Stage: 9, Head: 51 Metre, Discharge: 1.8 m3/hr. (Make: KSB / VOTA / Kirloskar / BS)

1

16131

16131

... More
Installation ,testing & commissioning of Submersible pump 1.0 HP complete suatable for 415 volt 50 Hz 3 ph supply in existing bore well incl. necy. connection etc. as reqd.

1

4419

4419

... More
Supplying and fixing of 3 core 2.5 Sq.mm copper flat Submercible cable as per IS 694:1990 with ISI mark) alongwith column pipe / surface / in pipe etc. as required. (KEI / Polycab / RR kabel / Havells / Currency)

25

2925

117

... More
Supplying and erection of steel rope 6 mm dia with PVC insulation coating for protection of pump against falling with U Bolt as per instruction of Engineer in charge.

50

6600

132

... More
Supply and errection of M.S Sign Board (1200mm x 900 mm) with necessary lettering etc. complete. Fabrication and errection of the board to be done with M.S angles such as, frame (25x25x5 mm), M.S sheet of 0.5 mm thick & Posts with M.S angles (50x50x6 mm) section at a clear hight of atleast 2.50 mtr. above ground level. Erection of the complete board (priming. painting and writting of the work related informations) as per supplied proforma, has to be carried out by digging holes (0.60 x 0.60 x 0.60 mtr) in all sorts of soil and packing the M.S angle posts with cement concrete (1:3:6) of section (0.45 x 0.45 x 0.90 Mtr) and filling the gaps with the excavated earth including priming and 2 coats of painting on both sides complete in all respect as per direction of the E-I-C.

1

9124

9124.06

... More
Add GST @18%

1

56249

56249.34

... More
Add Labor Welfare Cess @ 1%

1

3687

3687.46



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.