Public Works Department Tender

... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date29 Apr 2025
Closing Date28 May 2025
Tender Amount₹ 4,73,37,373 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Performing Vertical load test on single Pile in accordance with IS:2911(Part-IV) by hydraulic jacks on pile/piles with 1.5 times the design load including preparation of the head of piles with concrete of required strength for receiving the jacks with all ancillary arrangements for setting up gauges, construction of suitable platforms, keeping the loads and dismantling and removing all arrangement etc. complete as per IS specification and direction of Engineer-in-charge iv) Testing load between 200 T and 250 T. ii) Pile diameter - 600 mm

1

112000

112000

... More
Integrity testing of Pile using Low Strain / Sonic Integrity Test / Sonic Echo Test method in accordance with IS 14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerized equipment and high skill trained personal for conducting the test & submission of results, all complete as per direction of Engineer-incharge. b) For Rest of South Zone & West Zone

64

870

55718.4

... More
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1500 mm

308

11927

3673516

... More
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation. Same Qty of excavation

308

7754

2388232

... More
(iii) With carried earth arranged by the contractor within a radius exceeding 3 km. but not exceeding 5 km. including the cost of carried earth.

943.25

39901

37636618.25

... More
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.

197

24

4728

... More
(B) Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)

585

85173

49826205

... More
(d) Treatment to the back filling of R.C.C. foundation with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight at the rate of 7.5 ltr. per sq.m. of the vertical surface of the substructure of each side of the foundation. The work shall be carried out as per specification as described in para 6.3.1 of code IS- 6313 (part-II) 1981 (Mode of measurement will be per sq.m. of vertical area of foundation treated).

465

137

63705

... More
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

827

348

287796

... More
Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (A) [Pakur Variety] (a) 1:3:6 proportion

97

4609

447123.44000000006

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes. Pakur variety In Ground Floor

2

4671

9342.46

... More
In First Floor

2

4767

9534.46

... More
In Second Floor

2

4863

9726.46

... More
In Third Floor

1

4959

4959.23

... More
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] M 25 Grade a) Pakur Variety In ground floor and foundation.

361

6055

2186154.63

... More
In First Floor

168

6150

1033339.44

... More
In Second Floor

183

6245

1142986.89

... More
In Third Floor

54.3

6340

344307.06899999996

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works In Ground Floor (f) 25 mm to 30 mm shuttering without staging in foundation

74

205

15170

... More
(c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work

1849

359

663791

... More
In First Floor

1130

377

426010

... More
In Second Floor

1231

395

486245

... More
In Third Floor

335

413

138355

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. JSW/JSPL/SHYAM/...........(i) Tor steel/Mild Steel In ground floor and foundation.

118

54947

6483777.859999999

... More
In First Floor

23

55377

1273677.21

... More
In Second Floor

29

55807

1618410.8299999998

... More
In Third Floor

19

56237

1068508.13

... More
Brick work with 1st class bricks in cement mortar (1:6) In Ground Floor (a) In foundation and plinth

151

5153

778110.55

... More
(b) In superstructure, ground floor

5

5375

26875.25

... More
In First Floor

5

5486

27430.25

... More
In Second Floor

5

5597

27985.25

... More
250 mm th. Autoclave aerated concrete block Work with size 625 mm x 250 mm x 125 mm- Grade-I, having drying Shrinkage less than 0.05% conforming to IS: 2185 (Part-3)-1984 made up of fly ash (conforming to IS: 3812-1981, with permissible loss on ignition upto 6% ), lime , cement and laid in Cement Mortar (1:6) complete in all respect as per direction & satisfaction of Engineer -in Charge . In superstructure, In Ground floor

35

5830

204072.75

... More
In First Floor

39

5942

231763.34999999998

... More
In Second Floor

39

6054

236131.34999999998

... More
In Third Floor

54

6166

332999.1

... More
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) In Ground Floor.

236

704

166269.08

... More
In First Floor

222

716

159069.66

... More
In Second Floor

439

728

319824.67

... More
a) Applying 2 coats of bonding agent with synthetic multi functional rubberemulsion having adhesive and water proofing properties by mixing with waterin proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer'sspecification [Cement to be supplied by the Department]

532

88

46816

... More
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety In Ground Floor, For Entrance Road

83

5571

462454.42

... More
In Third Floor

34

5856

199129.16

... More
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (e) Sal : Malayasian In Ground Floor

0.68

75572

51388.96000000001

... More
In First Floor

0.23

75772

17427.56

... More
In Second Floor

1.13

75972

85848.35999999999

... More
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. (a) 35 mm thick shutters (single leaf) In Ground floor.

29

2659

77111

... More
In First floor.

10

2673

26730

... More
In Second floor.

48

2687

128976

... More
Supplying, fitting & fixing fire resistant door frame conforming to IS:3614, tested and certified as per laboratory approved by Engineerin- charge, of section 143 x 57 mm having built in rebate made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 120 minutes fire rated door shutters. The frame is fitted with intumescent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with back plate bracket and anchor fastener of approved size and make. Rubber door silencers should be provided on striking jamb. Supplying, fitting & fixing fire resistant Door leaf of 46 mm thick fully flush double skin glazed fire resistant door shutters with or without vision lite, of 120 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 18 SWG G.I. sheet (zinc coating not less than 120 gm/ m2) duly filled heat-resistant phenolic resin bonded insulation material (honeycomb craft) and fixing with necessary stainless steel ball bearing hinges of approved make. For pair of doors astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturer recommendation with a beeding and screw from inside. The glass should be 6mm clear borosilicate fire rated glass of relevant rating. All door and frames shall be finished with polyurethene aliphatic grade paint of approved colour including applying a coat of approved brand fire resistant primer. The door leaf and frame shall have passed minimum 250 hours of salt spray test. Rate should include supply and installation complete as per direction of Engineer-in- charge. ii) 2 hour Fire rated door double leaf of size (1470 mm x 2170 mm), In Ground floor.

3

29957

89871

... More
In First floor.

3

30256

90769.70999999999

... More
In Second floor.

3

30556

91668.42

... More
Supplying, fitting & fixing Surface mounted Crash Bar/ panic Bar of touch pad style, made of heavy duty cast iron/ steel body & latches with SS, BHMA certified & conforming to ANSI A 156.3 for grade-1 (3 hours fire rated) and suitable for surface mounting to ooden/hollow metal/ Al framed door withopening upto 900mm, with maximum operating force 6 kg for unlocking easily & outwardly during emergency, complete in all respect as per direction & satisfaction of Engineer-in-Charge

9

8081

72729

... More
Supplying, fitting & fixing Surface mounted overhead Door Closer for 2 hour fire rated doors, of size EN-4 for leaf width upto 950/ 1100mm weighing maximum 60/ 80 kgs, CE certified, marked & conforming to EN 1154-2003 of approved quality of reputed brand, complete as per direction & satisfaction of Engineer-in-Charge. For leaf width upto 1100mm

9

3880

34920

... More
Supplying, fitting & fixing Stainless Steel 'D' or 'H' type of size 300 mm x 19 mm tubular Handle with Grade 304, CE certified, marked & conforming to EN - 1154, of approved quality of reputed brand as per direction of Eingineer-in- Charge fitted and fixed complete including all incidental charges.

9

1571

14139

... More
Supplying, fitting & fixing of partly glazed partly panelled or fully glazed single leaf Aluminium swing door of all aluminium sections viz door frame ( top and side frame), shutter( top rail, bottom rail, lock rail, door vertical) , glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868- 1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium door with door spring,/aluminium hinges, glass / Panel board all complete as per architectural drawings and direction of Engineer-incharge. ( Excluding cost of glass/ panel board, door spring/ Al hinges, door closer, door stoper, handle, tower bolt and locking arrangment etc) 10-12 Micron thickness Annodizing film Natural white

65

385

25025

... More
Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP (b) 4mm thick (0.50mm Al.+3.0mm LDPE +0.50mm Al. PVDF coating)

7

2878

20146

... More
Providing and fixing factory made door frame (single rebate) made of single piece extruded solid PVC profile with homogenous fine cellular structure having smooth outer integral skin having 62mm width x 32 mm thickness (the door frame is to be made with single piece extruded solid pvc profile whereas no sheet pasted profile shall be applied for door frame fabrication) and shall be fixed to wall as per instructions of Engineer – in – charge using 100 x 8 sheet metal CSK screws.

75

483

36225

... More
Providing & fixing factory made 30 mm thick factory made solid pvc door shutter made out of single piece extruded solid pvc profile . The style & rails shall be of size of 75 x 30 mm having wall thickness of 5 mm. The style and top bottom rail shall have one side a thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power. 15 mm thickness shall be of single piece extruded solid pvc profile whereas it shall be not be made of sheet pasted profile) . The styles and rails shall be einforced with MS tube of size 18 mm(±) 1mm x 18 mm (±) 1mm x 1mm painted with primer all four corners of reinforcement to be welded or sealed . solid pvc extruded bidding (push fit type) will be set inside the styles and rails with a cavity to receive single piece extruded 5 mm pvc sheet as panel. The styles and rails will be metered cut and join with the help of pvc solvent cement, self tapping screw and braket of size 200 x 75 mm /welded at each corner. Single piece extruded solid pvc lockrail of size 100 x 30mm with a wall thickness 5 mm & 15 mm integrally extruded in the middle of lockrail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100mm x 8mm complete as per manufacturers specifications and direction of Engineer-in-Charge b) Factory made Single piece extruded PVC profiles door shutter of both side laminated wood grains decorative Finish:

24

2727

65448

... More
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. (vii) 100mm. X 58mm. X 1.90mm.

243

47

11421

... More
Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete. (iii) 300mm x 16mm dia. bolt.

53

231

12243

... More
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: (iii) 150mm long x 10mm dia. bolt.

30

63

1890

... More
(x) 300mm long x 12mm dia. bolt.

92

151

13892

... More
(ii) Door stopper (Anodised aluminium)

35

70

2450

... More
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: (a) With continuous plate base (Hexagonal/ Round rod) (vii) 150 mm grip x 12 mm dia rod.

212

111

23532

... More
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs. (ii) Grill weighing above 16 Kg./sq.m In Ground Floor

8

9696

77568

... More
In First Floor

8

9792

78343.68

... More
In Second Floor

8

9889

79119.36

... More
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx)

52

9077

472004

... More
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete

24

4330

103920

... More
Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868 - 1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2 - track/3 - track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white 6.5kg/sqm for three track sliding window

1156

448

517888

... More
Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). (A) In 10-12 Micron thickness Annodizing film I) Natural white h) Louvered window. i) Top, bottom and side member.

32.4

183

5929.2

... More
ii) Louvered Section.

14.4

658

9475.2

... More
iii) Cleat angle ( Non-annodized).

12

263

3156

... More
Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units:- (A) Glazed aluminium sliding windows made of extruded and annodized alloy aluminium sectios, fabrications, including cutting to proper shape and size, drilling and aligning of window shutter frame fitted with in built locking arrangements, sliding rollers and other necessary fittings, fixture, adhesives and joineries along with extruded neoprine or EPDM gasketing in between window frame and masonry work (walls, column, beam.lintels etc.) as well as between glass and shutter frame for fixing glass and Polysulphide sealant and in between shutter and window frame where necessary including cutting to requisite size and fixing glass as per drawing, specification and direction of EIC. The rate includes the hire charge of all tools and plants, including all incidental charges, adhesive, joineries such as screw, cleat angle etc. but excluding the cost of extruded aluminium sections, glass, neoprene / EPDM gasket, locking arrangement and rollers. v ) Louvered window.

5.4

730

3942.0000000000005

... More
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. ii) 4mm thick coloured / tinted / smoke glass.

172

468

80496

... More
Labour for Chipping of concrete surface before taking up Plastering work.

4543

21

95403

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary. [Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar (b) 20 mm thick plaster In Ground Floor

298

155

46407.53999999999

... More
In First Floor

299

159

47759.27

... More
In Second Floor

299

163

48955.27

... More
In Third Floor

255

167

42771.149999999994

... More
(i) With 1:6 cement mortar (c) 15 mm thick plaster In Ground Floor

401

136

54756.55

... More
In First Floor

311

140

43711.05

... More
In Second Floor

311

144

44955.05

... More
In Third Floor

368

148

54666.4

... More
(ii) With 1:4 cement mortar (b) 10 mm thick plaster In Ground Floor

941

122

115319.55

... More
In First Floor

953

126

120602.15

... More
In Second Floor

953

130

124414.15000000001

... More
In Third Floor

286

134

38481.3

... More
(c) 15 mm thick plaster (1:4) In Ground Floor

875

151

132335

... More
In First Floor

609

155

94541.16

... More
In Second Floor

1076

159

171342.24000000002

... More
Extra for fluted, corrugated or ribbed plaster (over rate of corresponding rate of plaster). (Cement 0.135 Cu.m/100Sq.m)

123

37

4661.7

... More
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement In ground floor. (iii) 35 mm. thick

95

314

29849.949999999997

... More
In Fourth floor. (iii) 35 mm. thick

15

333

4995.75

... More
Supplying dividing strip fitted and fixed with cement mortar (1:3) in mosaic or patent stone floor, dado etc. complete as per direction of the Engineer-in-charge. Glass 3 mm thick (c) 37 mm. wide strip

91

19

1729

... More
Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr's hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor). a) : Sizes-300 mm x300mm x10 mm with breaking strength > 1200 N In Ground Floor

40

898

35937.2

... More
In First Floor

40

910

36417.2

... More
In Second Floor

40

922

36897.2

... More
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @2.91 Kg/Sq.m & joint filling using white cement slurry @0.20kg/Sq.m. (a) Area of each tile above 0.09 Sq.m (i) Coloured decorative In Ground Floor

204.5

1090

222992.93500000003

... More
In First Floor

204.5

1095

224015.43500000003

... More
In Second Floor

204.5

1100

225037.93500000003

... More
Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brand conforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) ≤ 0.08 %] in floor, skirting etc. using polymerised adhesive of 6mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course and joints grouted with admixture of white epoxy grout materials of approved brand including spacer -2mm as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges complete as per direction of Engineerin- Charge. (Note: This work should not be executed without specific permission of Superintending Engineer) (a) ln Ground FIoor:(size not Iess than 600mmX 600 mm X 9.5 mm thick) ln Ground Fioor

460

1468

675477.8

... More
In First Floor

405

1480

599574.15

... More
In Second Floor

460

1492

686517.8

... More
Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mm hickness in floor, lobby, stair, landing & treads etc. over 20 mm (av.) thck base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary pigments including grinding and Granite polishing as per direction of Engineering -in -Charge in Ground Floor. {White cement and Pigment to be supplied by the Agency] (a) With Makrana plain pink / Adranga Pink / Garbh Gulabi / Udaypur pink / Udaypur Green / Black Bhaslana (iii) Area of each Slab/tile exceeding 0.60 sq.m but not exceeding 1.00 sq.m. ln Ground Fioor

64

1900

121610.88

... More
In First Floor

65.9

1912

126012.00300000001

... More
In Second Floor

65.9

1924

126802.80300000001

... More
Extra cost of labour for prefinished and premoulded Nosing to treads of steps, railing, window sill etc. of Marble Stone.

382.7

258

98736.59999999999

... More
Extra cost of labour for Marble Stone Floor in treads of Steps In Ground Floor

80

226

18080

... More
In First Floor

66

226

14916

... More
In Second Floor

66

226

14916

... More
Supplying and laying chequered tiles of any shade & of approved quality with (1:1½:3) cement concrete laid in panels or patterns as directed in pavement, footpath etc. including necessary underlay 25 mm thick [avg] cement mortar (1:3) complete in all respect with all labour and materials. [Using cement slurry @ 4.4 kg/Sq.m at back side and @2.4 kg/Sq.m for joint filling] Red Variety, 30 mm thick.

17

481

8191.96

... More
Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging ,curing and roughening of concrete surface complete. Area of each Granite slab > 0.6 upto 1.0 square metre. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m]

33

2750

90755.61

... More
Supplying, fitting & fixing granite tiles 10mm to 12mm. thick in columns, wall, facia etc. with 15 thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging ,curing and roughening of concrete surface complete. [Using cement slurry at back side of tiles@ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] (iii) Area of each Slab/tile exceeding 0.60 sq.m but not exceeding 1.00 sq.m. In Ground Floor

6

3318

19913.760000000002

... More
In First Floor

6

3330

19985.760000000002

... More
In Second Floor

6

3342

20057.760000000002

... More
Supplying & laying as per IRC-SP:063-2004 paver unit of any shade of approved quality as per relevant IS code, laid in pattern as directed in pavement, footpath, driveway (paver block only), etc including necessary underlay complete in all respect with all labour and material. [Border concrete if necessary to be paid separately]. Note: Sub-grade CBR should not be less than 5. a) 25 mm thick Tiles as per IS: 1237-2012 for Footpath,ramp ,staircase of public building(over 25 mm thick (Avg) Cement mortar (1:3) & Cement Slurry @ 4.4 kg/Sq.m at back side of Block. Cement for Mortar & Slurry to be supplied by Department). (ii) Coloured Decorative

40

683

27330.4

... More
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/ Bitumen/ M-Seal etc) complete. A) UPVC Pipes: (ii) 110 mm. Dia.

118

251

29618

... More
c) Bend 87.5 degree (ii) 110 mm. Dia.

10

160

1600

... More
d) Shoe (ii) 110 mm. Dia.

10

111

1110

... More
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. Two coat In Ground floor

468

4510

2110680

... More
In First Floor

389

4581

1782009

... More
In Second Floor

389

4652

1809628

... More
In Third Floor

610

4723

2881030

... More
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. c) Super Protective 100% Acrylic Emulsion. Two coats. In Ground floor

468

97

45396

... More
In First Floor

389

97

38009.189999999995

... More
In Second Floor

389

98

38285.38

... More
In Third Floor

610

99

60469.299999999996

... More
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) Two coat i) Water based interior grade Acrylic Primer In Ground Floor

2114

4420

9343880

... More
In First Floor

1861

4420

8225620

... More
In Second Floor

2328

4420

10289760

... More
In Third Floor

189

4420

835380

... More
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) i) Standard Quality In Ground floor

2114

62

131068

... More
In First Floor

1861

62

115382

... More
In Second Floor

2328

62

144336

... More
In Third Floor

189

62

11718

... More
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) In Ground floor

2114

122

257908

... More
In First Floor

1861

122

227042

... More
In Second Floor

2328

122

284016

... More
In Third Floor

189

122

23058

... More
(a) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.

296

38

11248

... More
(b) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.

172

29

4988

... More
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white) a) On timber or plastered surface :

296

81

23976

... More
b) On steel or other metal surface :

172

79

13588

... More
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. 4mm thick coloured / tinted / smoke glass.

172

468

80496

... More
Neat cement punning about 1.5 mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.

70

32

2293.2

... More
SANITARY & PLUMBING WORKS Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) Pipes (i) Single Socketed 3 Meter Length (b) 110 mm

69

292

20148

... More
(B) Fittings (iii) Door Tee (b) 110 mm

9

195

1755

... More
v) Plain Y (b) 110 mm

6

206

1236

... More
(ix) Bend 45º (b) 110 mm

6

89

534

... More
(x) Bend 87.5º (b) 110 mm

9

120

1080

... More
xi) Door Bend (T.S.) (b) 110 mm

9

147

1323

... More
xv) Vent Cowl (b) 110 mm

4

33

132

... More
xxi) 110 X 110 P Trap 75 mm

12

281

3372

... More
Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge. (Payment will be made on centre line measurement of the total pipeline including specials. (A)Above ground (b) 110 mm

54

57

3078

... More
(B) Under ground (b) 110 mm

15

84

1260

... More
Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding 'P' or 'S' trap (excluding cost of concrete for fixing). (i) 580 mm X 440 mm

2

1613

3226

... More
Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. (a) With 'P' trap

13

1421

18473

... More
Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete. (i) 635 mm X 395 mm X 420 mm

9

2869

25821

... More
Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. (ii) Plastic (hallow type) white

13

380

4940

... More
Supplying, fitting and fixing 32 medium flush pipe fittings of approved brand. i) Polythene Flush Pipe

15

155

2325

... More
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.

15

1015

15225

... More
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. (iii) 630 mm X 450 mm size

15

3260

48900

... More
Supplying, fitting & fixing chrome plated brass battery based infrared sensor oprated pillar cock , having foam flow technology. (Model: Pillar Sensor Faucet of Hindware or similar brand). [Note: This work should not be executed without specific permission of Superintending Engineer.] 15 mm normal bore

3

6987

20961

... More
Supplying, fitting and fixing bevelled edged mirror 5.5 mm thick silver red as per I.S. 3438 / 1965 together with brass C.P. hinges. (ii) 600 mm X 450 mm

18

484

8712

... More
Supplying, fitting and fixing towel rail with two brackets. (b) Aluminium (ii) 25 mm dia. and 600 mm long

18

164

2952

... More
Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. (iii) 600 mm long

39

107

4173

... More
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (a) For Exposed Work (i) CPVC Pipes Class-1, SDR-11 32mm

20

283

5660

100

403

40300

15

658

9870

... More
(b) For Concealed Work (Dia) 20 mm

125

171

21375

75

235

17625

... More
Supplying, fitting and fixing shower of approved brand and make. (g) PTMT overhead shower (Prayag or equivalent) (i) 75 mm round

9

179

1611

... More
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). (iv) 50 mm dia

2

2277

4554

... More
(v) 40 mm dia

5

1590

7950

... More
(vi) 32 mm dia

3

1160

3480

... More
(vii) 25 mm dia

12

778

9336

... More
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (d) 2000 litre capacity

4

10434

41736

... More
Labour for hoisting plastic water storage tank. (ii) Above 1500 litre upto 5000 litre capacity Upto 3rd story from G.L.

4

298

1192

... More
Labour for punching hole in plastic water storage tank upto 50 mm dia.

16

19

304

... More
Supplying, fitting and fixing bib cock or stop cock. (a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand).

27

539

14553

... More
(b) (i) Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar

45

493

22185

... More
Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe,with PVC coupling at one end fitted with necessary clamps. (ii) 750 mm long

27

59

1593

... More
Supplying, fitting and fixing White Vitreous China Sink in position on C.I. brackets including two coats of painting of brackets. (a) Plain edge sink with overflow (ii) 610 mm X 450 mm X 250 mm

6

5445

32670

... More
Supplying, fitting & fixing Aluminium domical grating. (iii) 100 mm

12

49

588

... More
Supplying, fitting and fixing bathroom shelf of approved make of size 580 mm X 150 mm (porcelain).

12

613

7356

... More
(f) Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar).

13

1251

16263

... More
Supplying, fitting & Fixing EWC (Size- 710x370x810 mm)in white glazed vitreous chinaware of approved make supplying, fitting and fixing in position complete with necessary nut and bolts. (Model Code No. S10221114-P Trap (CRUSE SET) of CERA or equivalent.)

3

5446

16338

... More
Supplying, fitting and fixing 10 litre white glazed vitreous chinaware of approve low-down cistern of approved make with either side or bottom inlet, side overflow, brackets complete with all internal fittings. (Model Code No. S1060106 of CERA or equivalent.) White

3

2406

7218

... More
Soft Close seat cover of approved make with lid and C.P. hinges, rubber buffer and brass screws suppling, fitting and fixing complete. E W C (Model Code No. B1520118 of CERA or equivalent.) White

3

1299

3897

... More
Supplying, fitting and fixing Stainless steel Wall Mounted Grab Bar. Load bearing capacity 150 kg, covered by Nylon surface with contour finish (for better grip) with Anti-bacterial surface complete. Model Code No. B2210106 of CERA or equivalent.) White 600.00 mm long

6

1825

10950

... More
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling,15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. i) With Pakur variety. [ JSW/JSPL/SHYAM...... ]

8

6837

54696.32

... More
Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4:1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. [ Other Than SAIL/ TATA/ RINL ] (v) For 100 users A) With Pakur variety. JSW/JSPL/SHYAm……

1

108369

108369.77

... More
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials.With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. [ JSW/JSPL/SHYAM...... ]

1

16080

16080.75

... More
Electrical Installation Work:- Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make:- Havells/Gloster/RR/Polycab) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finis. Average run 8 Mtr. [2(a) / E-9 ]

306

996

304776

... More
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make:- Havells/Gloster/RR/Polycab) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish. On Board. [ 4(a) / E- 10 ]

68

78

5304

... More
Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F 19 mm dia 3 mm thick polythene pipe without earth continuity wire heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works [E-2/3a]

2940

90

264600

... More
Cutting channel of 43 mm x 43 mm size on masonry wall incl. S&F 25 mm dia 3 mm thick polythene pipe without earth continuity wire heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works [E-2/4a]

480

114

54720

... More
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make:- Havells/Gloster/RR/Polycab) of the following sizes in the prelaid 19mm polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3x(1.5 sqmm) [E-9, 1(b)]

720

49

35280

... More
2x(2.5 sqmm)+1x(1.5 sqmm) [[E-9, 1(s)]

2130

67

142710

... More
2x(4 sqmm)+1x (2.5 sqmm) [[E-9, 1(v)]

90

98

8820

... More
2x(6 sqmm)+1 x (4 sqmm) [[E-9, 1(y)]

360

143

51480

... More
4x(10sqmm)+2x(6 sqmm) [[E-9, 1(d1)]

120

508

60960

... More
Supplying & Fixing sheet metal inspection box with cover (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works 150 mm x 100 mm x 65 mm [11(b)/E-4]

8

147

1176

... More
200 mm x 150 mm x 65 mm [11(d)/E-4]

10

218

2180

... More
175 mm x 100 mm x 65 mm [11(c)/E-4]

10

162

1620

... More
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Make:- Anchor) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required [E-7, 26]

66

775

51150

... More
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch ((Make:- Anchor)) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. [E-6, 22]

5

296

1480

... More
S & F 240 V, 2 nos. 6A, plug socket with separate 2 nos. 6 A Piano key type switch, (Anchor/ISI-marked) on sheet metal switch board embedded in wall incl. S & F 175 x 100 x 65 mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required (Seperate 2x 6A plug). [NS]

24

273

6552

... More
Supply & Fixing 240 V, 25 A, Modular type starter (Make- Legrand/seimens/Crabtree/Wipro) with 25A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-19/17]

3

808

2424

... More
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Make- Anchor ), and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-17, 5(a)]

3

364

1092

... More
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Make- Legrand /seimens /Crabtree /Wipro /anchor) & necy. Connections. [E-17,5(b)]

3

133

399

... More
Supplying and fixing 415V, 125 A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make-Lauritz Knudsen(L&T)/ Schneider/ Seimens) [D-3, 4(a)]

1

7637

7637

... More
Supplying and fixing 415 V, 16-32A per way, 8 Way Vertical TPN MCBDB with provision for FP MCCB as incommer and TP MCB as outgoing in suitable enclosure with metal door comprising of the following :- a) 125 A, 35KA, 4 pole MCCB -- 1 No. b) 63A TP 10ka, 'C'- curve MCB --8Nos. c) Cable end box-- 2 nos. ( (Make- Seimens/Legrand/Schneider ) D-6/7, D-8/10,D-11/15,D-12/16

1

33395

33395

... More
Supplying and fixing 415 V, 25-32A per way, 6way TPN MCBDB with SS enclosure double-door with IP-42/43 protection with 63A Four Pole Isolators as incomer and 18 non SPMCBs ('C' Curve, 10 kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment, 1no. 63A FP Isolator, 18 no. (16-32A) SPMCB. (Make- Seimens/Schneider)/Legrand) (D-5/6,D-6/7,D-10/14)

4

8002

32008

... More
Supplying and fixing 250 V, 6-10A per way, (2+12)SPN MCBDB with SS enclosure double-door with IP-42/43 protection with DP Isolators as incomer and SPMCBs ('C' Curve, 10kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment, 1no. 40A DP Isolator, 12 no. (6-16A) SPMCB). (Make-(Make- Seimens/Legrand/Schneider/Schneider ) D-5/6,D-6/7,D-10/13

6

4518

27108

... More
upplying and fixing 250 V, 6-10A per way, (2+8)SPN MCBDB with SS enclosure double-door with IP-42/43 protection with DP Isolators as incomer and SPMCBs ('C' Curve, 10kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment, 1no. 40A DP Isolator, 8 no. (6-16A) SPMCB). (Make-(Make- Seimens/Legrand/Schneider) D-5/6,D-6/7,D-10/13

6

3446

20676

... More
Supplying & Fixing ply suitable size having 12 mm thick with comprising of one 250 V 160 A kit-kat fuse unit, on porcelain chair insulator and proper socketing, MS clamps with bolts, nuts etc. including painting with anticorrosive paint.

1

1500

1500

... More
Supply & Laying of 1.1 KV. Gr. armored XLPE/A Al. LT cable on wall of following rating for connection including finishin and gland [Make-GLOSTER/Havells/RR] [NS] 4 core X 50 sqmm

50

711

35550

... More
2 core X 10 sqmm

200

207

41400

... More
Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting

50

73

3650

... More
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting

200

59

11800

... More
Supply and Delivery of Timer DB 1) 230V, Upto 16 A capacity 24 Hrs Analog Electromechanical Time Switch(Make:- Lauritz Knudsen (L&T) Cat No: -AUTS03ANA00/Legrand/SEIMENS) 2) 2 Pole Power Contrcator (Make:- Lauritz Knudsen (L&T))-MNX 22-2P Cat No-CS90238/Legrand/seimens), 3) 20A SP MCB. (Make:- ABB/Seimens/Lauritz Knudsen (L&T)/Legrand) 4) 32A DP Isolator. (Make:- Legrand/Lauritz Knudsen (L&T)/Seimens) 5) Toggle Switch. (Make:- Lauritz Knudsen(L&T)/Legrand or equivalent make) 5) (2+12 Way) SPNDB [Make:- Legrand/Seimens/Lauritz Knudsen(L&T) ] 6) Bakelite base with FP bolt type stud / Terminal block incl S & F Neutral Bar etc with this box for termination of power. 7) The complete arrangement must be wiring by 2.5 Sq mm PVC insulated Cu wire with suitable length incl socketing /lugs etc as per requirement & direction of EIC (Make - Legrand / Lauritz Knudsen(L&T)/Seimens )

1

8296

8296

... More
Excavation of soil for installation of Earth Electrode and filling & ramming.For Morrum Soil. [G01 : 1b]

6

295

1770

... More
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. Long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. Long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. Below the ground level as below: a) By ISI-Medium GI pipe. [G01 : 2a]

2

1410

2820

... More
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS No.-4 SWG [5(a)(i)/G-2]

30

19

570

... More
S & F of road lighting LED luminaire 230 Volt, 50Hz with IP 66 rating with 10KV SPD, minimum 110 lumen/watt including Supply and fixing of 50 mm. dia 1.5 mtr. long G.I. Single arm bracket fixing on wall by suitable nut bolt clamp arrangement for fixing of outdoor light as per direction of EIC (Make: Signify Cat No- BRP501 LED 105 CW R3C PSU S1 / Crompton Cat No- TRP-411-90-57-HL2-GL-NSG/ Havells/ Wipro)

10

7224

72240

... More
Supply & Delivery of twin LED Tube light fittings (make- Philips, Cat No. TMC-502 2XT-LED 22W or equivalent model of CG Fittings- IGP162 LT8-16 2 x T8 with 02 Nos LED TUBE Philips Cat No- Mas LEDTube 1200mm 18W 865 T8 I – 2100lm /Crompton- Cat No- LTB-20-865-(2) or equivalent make and model of Havells)

87

1440

125280

... More
Supply & Delivery of Single LED Tube light fittings (make- Philips, Cat No. TMC-502 P1xT-LED 22W / equivalent model of CG Fittings- IGP161LT8-16 1 x T8 with 01 Nos LED TUBE Philips Cat No- Mas LED Tube 1200mm 18W 865 T8 I – 2100 lm /Crompton- Cat No- LTB-20-865-(2) or equivalent make and model of Havells)

76

840

63840

... More
Supply & fixing of 10 W surface mounted round LED light fittings having 100 lm/Watt with glare free uniform illumination Incl. necessary connections as per direction of EIC. (Make- Signify (Phillips) Cat No-DN495 LED10S 6500 PSU WH or equivalent model of Havells/CG / Bajaj as approved by E.I.C )

1

1080

1080

... More
Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling with HW block and suitable size MS fastener, Ceiling plate, nipples etc. as required.[ 14d/C-2 ]

10

166

1660

... More
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.[C-2/17]

153

205

31365

... More
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling and supply and fixing of 230V, 9W LED lamp. Make- Signify (Phillips)/ Havells/CG ) [ 22/D-13 ]

6

144

864

... More
Supply & delivery of AC 240V 50 Hz 48" sweep (1200 mm) ceiling fan complete with down rod, Canopy, fork incl S & F of P - 2 type capacitor as per IS specification & proper Manufacturer certificate of the capacitor and Safety Wire (supplied at the time of delivered the fans ) etc. without regulator, (Make- Usha 1200MM STRIKER PWD ISI 1 STAR (Safety Wire & S3 Capacitor) Br /Orient Electric- New Breeze (5yrs warranty),1200 mm sweep; 44W; 320 rpm; 225 cmm; 3 star ac ceiling fan or equivalent model of Crompton Greaves and as per direction of EIC as per direction of EIC.

121

2506

303226

... More
Supply & delivery of heavy duty Exhaust fan(Make-EPC] of followinng sizes:- 9"( 230mm ) Speed 1370 RPM

13

2211

28743

... More
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 9"( 230mm)

13

256

3328

... More
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long)

13

128

1664

... More
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991) [ 29/D-14 ]

121

249

30129

... More
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. [10/E18]

121

399

48279

... More
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board [ 20( a )/D-13 ]

2

178

356

... More
SITC of AC Machine Supply and delivery of Non-inverter wall mounted SPLIT room air conditioner having the following major specification:- (a) Minimum Cooling capacity required: 18000 BTU / Hr. or Higher (b) Minimum Star rating- 2 Star or higher (c) Rated voltage—230V +/-5%, Frequency-50Hz. (d) Compressor type- Rotary. (e) Mini. Room Discharge air flow rate - 620 CFM or higher f) Condenser type -Copper condenser coil g) Minimum Tonnage required: 1.5T or higher h) Refrigarent- R32/R410A i) Cordless Remote arrangement with all modernize provision of temperature setting, Fan speed option(low/medium/high), Auto swing, Air direction setting, Timer facility, Turbo operation setting, Air ventilation arrangement and others.Incl. delivery charges. ( Make:- Mitsubishi Electric Model- MS/MU- AGZ18VF-KT /O-General Model - ASGA18BMWA-B /Mitsubishi Heavy Industries).

2

42560

85120

... More
Supply and delivery of Non-inverter wall mounted SPLIT room air conditioner having the following major specification:- (a) Minimum Cooling capacity required: upto 24000 BTU / Hr. or Higher (b) Minimum Star rating-2 Star or higher (c) Rated voltage—230v +/-5%, Frequency-50Hz. (d) Compressor type- Rotary. (e) Mini. Room Discharge air flow rate- 650 CFM or higher f) Condenser tube -Copper condenser coil g) Minimum Tonnage required: 1.9 TR or higher h) Refrigarent- R32/R410A i) Cordless Remote arrangement with all modernized provision of temperature settings, Fan speed option(low/medium/high), Auto swing, Air direction setting, Timer facility, Turbo operation setting, Air ventilation arrangement, and others.Incl. delivery charges. ( Make:-Mitsubishi Electric Model- MS/MU- AGZ24VF-KT /OGeneral Model - ASGA24BMWA-B / Mitsubishi Heavy Industries).

1

56000

56000

... More
Installation, Commissioning, and testing of 1.5/1.8/2.0 TR split type AC machine both indoor/outdoor including fixing 40 x 40 x 5 mm MS angle iron frame and mending good the damages.

3

1800

5400

... More
Supply, Installation & commissioning of hard/soft copper (0.6mm) refrigeration pipeline (Make- Ryoku/Rajco/Mandev) with 9 mm nitrile rubber tube Insulation on following sizes of suction line & Liquid Line copper pipe with proper insulation tape (Make-Accoflex/ Armacell/K-Flex, complete with fittings, elbows, bends, supporting arrangement on walls a) 5/8" OD

24

420

10080

... More
b) 1/4" OD

24

210

5040

... More
S & F of Control Cabling from starter to ODU and IDU of AC machine. a) 1.1 KV gr. Single core stranded PVC insulated 4 Core 2.5 sq. mm. Cu. Wire. (Make- Ploycab/Finolex / RR Cable/gloster)

40

127

5080

... More
Supply & laying Drain Water piping work by PVC / HDPE hard pipe of the following sizes incl. fitting, accessories, bends, elbows, tees, flanges, tappings, wall sleeves, hangers, supports, and anchors. (Make- Oriplast / Supreme.) a) 19mm dia PVC

20

90

1800

... More
Add : GST @18% (eighteen percent) on Sl. No. 1 to 145.

1

18

18

... More
Add : Labour Welfare Cess @ 1 % (one percent) i.e. Total amount including GST

1

1

1



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.