Public Works Department Tender

... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Public Works Department - PWD Tender

Works
Civil And Construction
Civil Works Others
Building Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date21 Apr 2025
Closing Date19 May 2025
Tender Amount₹ 32,05,98,385 
Notes
Download

Costs

Summary

Construction Of 3 Nos. Boys Hostel Building (g Plus 3) Having Capacity Of 200 Boys Each And 1 No. Of Faculty Resident Building G Plus 1 Including Necessary Allied

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Vehicle Shed (3 Nos.) Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.

1440

10

14400

... More
1st Floor

253.04

32

8125

... More
16 sq.mm.

440

18

7920

... More
3rd Floor

1804.56

33

60507

... More
4 core 16 sqmm

100

253

25300

... More
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: (x) 300mm long x 12mm dia. bolt.

15

151

2265

... More
(d) Add extra for excavation in morum soil

46.76

2082

974

... More
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation.

568.02

7754

44044

... More
Labour for Chipping of concrete surface before taking up Plastering work. In ground floor.

2076.06

21

43597

... More
Neat cement punning about 1.5 mm. thick in wall dado, window, sills, floor, drain etc.

1405.41

32

46041

... More
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. In ground floor

2.91

2763

8040

... More
(b ) 110mm

234

324

75816

... More
Boys Hostel(03 nos) Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.

39898.95

10

398990

... More
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC.(a) One CoatIn ground floor.

143.54

3140

4507

... More
iii) 160mm Dia.

5

507

2535

... More
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) b) Premium 100% Acrylic Emulsion

322.06

84

27053

... More
Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contrr]e) I (I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment. (A) Deep Colour & White At Ground Floor

141.67

1259

178378

... More
Fixing only 230 mm (9") exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust

11

254

2794

... More
ii) Godrej Hydraulic door closer fitted and fixed complete. (a) Heavy type

14

2064

28896

... More
(b) Chromium plated Rose shower with revolving joint and 150 mm long shower arm (Equivalent to Code No. 5489 & Model - Florentine of Jaquar or similar brand).

78

1412

110136

... More
200 mm x 150 mm x 65 mm

20

50

1000

... More
(b) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. In Ground floor

70.75

29

2052

... More
B(XVi) Pipe Clip (a) 75 mm

348

16

5568

... More
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987; iv) 5mm thick coloured / tinted / smoke glass.

8.64

585

5054

... More
(A) Extra over the corresponding item of collapsible gate for top hung

5.04

165

832

... More
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

686.7

344

236225

... More
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) b) Premium 100% Acrylic Emulsion .

143.54

84

12057

... More
Add GST @ 18% on total amount over item No. 438 to 512

15721127

18

2829803

... More
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) b) Premium 100% Acrylic Emulsion

3177.78

84

266934

... More
Granular Sub-base with Graded Material (Table:- 400-1) By Mix in Place Method: : Construction of granular sub-base by providing graded material(pakur variety), mixing in Wet Mix Plant at OMC, carriage of mixed material to work site, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber, compacting with vibratory power roller to achieve the desired density, including lighting, guarding, barricading, including cost of all materials, machinery, tools and plants and cost of quality control complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). (v) Grading – V (payment will be made on the basis of finished compacted volume)

465.95

2163

1008284

... More
Supplying, fitting and fixing in position reinforced cement polymer concrete manhole /gully pit cover with matching frame.As per I.S-12592(M.D) (iv) 15 MT load bearing capacity round manhole cover provided with two lifter hooks fitted with matching frame of size each 2536.00 Cover: 460 mm X 75 mm Frame: 620 mm X 150 mm opening: 360mm Weight: 100 kg (approx)

25

2536

63400

... More
Pre-Constructional Anti-termite measures: (d) Treatment to the back filling of R.C.C. foundation with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight at the rate of 7.5 ltr. per sq.m. of the vertical surface of the substructure of each side of the foundation. The work shall be carried out as per specification as described in para 6.3.1 of code IS6313 (part-II) 1981 (Mode of measurement will be per sq.m. of vertical area of foundation treated).

43.2

94

4061

... More
Supplying, fitting and fixing approved brand 32mm dia. Waste pipe (iii) 900mm long

183

75

13725

... More
Underground Reservoir Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1500 mm.

388.49

11927

46335

... More
Extra for using approved H.B netting in every third layer in 16 & 17 of subhead A above in any floor

119.34

41

4893

... More
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials

2.1

1304

2738

... More
Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. (iv) 750 mm long

276

117

32292

... More
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (A) For Exposed work PVC Pipes 15 mm

432

101

43632

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] i) With 1:6 Cement Morter b) 20mm Thick

611.61

151

92800

... More
Supply & Fixing of Testing Joints by 25 mm x 6 mm thick GI (Hot Dip) strip 125 mm long on wall after making suitable arrangement to establish a clearance of 50mm from wall for making junction connection with vertical conductor and conductor from earth electrode complete with S & F GI bolts, nuts, check-nuts, spring washers etc. and provide a protective arrangement for that junction point by keeping it in a GI housing / enclosure (openable for maintenance procedure) , as required. (P-J2/Item-13 + NS)

90

453

40770

... More
Vision aperture (round or retangular in shape) with 7.4kg. Per sq.m./ 3mm thick glass pane with wooden beads. (Cost of glass panes and wooden beads will be paid separately).

6

33

198

... More
ii) Godrej Hydraulic door closer fitted and fixed complete. (a) Heavy type

3

2064

6192

... More
125mm thick brick work with 1st class bricks in cement morter (1:4) Ground Floor

1414.35

697

986509

... More
250 mm th. Autoclave aerated concrete block Work with size 625 mm x 250 mm x 125 mm- Grade-I, having drying Shrinkage less than 0.05% conforming to IS: 2185 (Part-3)-1984 made up of fly ash (conforming to IS: 3812-1981, with permissible loss on ignition upto 6% ), lime , cement and laid in Cement Mortar (1:6) complete in all respect as per direction & satisfaction of Engineer -in Charge . In Ground Floor

30.66

5809

178114

... More
Locking arrangement for Jail type doors including supplying fitting and fixing in position complete as per approved design.

80

409

32720

... More
Labour for Chipping of concrete surface before taking up Plastering work. In ground floor.

49.14

21

1032

... More
Labour for punching hole in plastic water storage tank upto 50 mm dia.

120

19

2280

... More
(i) With 1:6 Cement mortar (b) 20 mm. thick plaster.a) In ground floor.

276.11

151

41894

... More
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete.

5.04

4330

21823

... More
Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white

23.27

448

10425

... More
Third Floor

46.86

5951

278910

... More
Fixing of single/double LED tube light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side inserted within the ceiling reinforcement and other side connected with the suitable size of bolts and nuts incl. S&F EI conduit “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. with S & F 2x24/0.20 mm flexible copper wire of 1.10 mt. length. incl. 2nos mounting kit.

1180

205

241900

... More
B) UPVC Fittings : a) Plain Tee ii) 110 mm Dia.

15

172

2580

... More
4 sq.mm.

310

7

2170

... More
Labour for punching hole in plastic water storage tank upto 50 mm dia.

4

19

76

... More
(iv) Door Tee(LH) & (RH) (a) 75 mm

2

178

356

... More
c) 2X36/0.3(2.5 SQMM)+1x22/0.3(1.5SQMM) as ECC (For Power Plug & Computer Point)

700

67

46900

... More
Add Labour Welfare Cess @ 1% on Total amount over Item No. 438 to 513

18550930

1

185509

... More
Pre-Constructional Anti-termite measures: (c) Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable ncentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS-6313 (part -II) 1981. ( Mode of measurment will be per Sq.m of plan area of plinth treated.)

230.81

81

18696

... More
ii)Avg. Run6 mtr

864

920

794880

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] With 1:6 cement mortar. 20mm thick. Ground Floor

76.24

151

11568

... More
Supplying & fixing medium gauge 80 mm dia GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required with necessary socketing/welding.

50

545

27250

... More
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR'PVC insulated & unsheathed single core stranded copper wire(Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish a) On Board

480

256

122880

... More
Supplying fitting fixing bathroom self of approved make of size 580 mm x 150 mm (porcelain).

6

613

3678

... More
3rd Floor

1804.56

124

224054

... More
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) With earth obtained from excavation of foundation.

31.18

7754

2418

... More
Supplying, fitting &fixing Closet seat of approved make with lid and C.P. hinges rubber buffer and brass screws supplied, fitted & fixed complete. (a) E.W.C. (iv) Bestolite (solid type) white

4

715

2860

... More
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: (iv) 150mm long x 10mm dia. bolt.

2

63

126

... More
S&drawing 1.1 kv single core stranded FR PVC insulated &unsheated single core stranded cupper wire (approved make)of the following sizes prelaid poly pipe. & by the Gifish wire & making necy connection as required. a) 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC (From HTPN DB to SPN DB)

2500

143

357500

... More
(b ) 110mm

2316

21

48636

... More
Fourth Floor

225.33

6046

1362548

... More
(B) Filling in foundation or plinth by Fine sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)

19.9

59961

11932

... More
(a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification

220.59

88

19412

... More
Supplying, fitting and fixing bib cock / stop cock - (a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand).

171

539

92169

... More
Extra cost of labour for prefinished and premoulded Nosing to treads of steps, railing, window sill etc. of Marble Stone.

4.8

258

1238

... More
Supplying, fitting & fixing Stainless Steel 'D' or 'H' type of size 300 mm x 19 mm tubular Handle with Grade 304, CE certified, marked & conforming to EN - 1154, of approved quality of reputed brand as per direction of Eingineer-inCharge fitted and fixed complete including all incidental charges

6

1571

9426

... More
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. Ground Floor (e) Sal : Malayasian

2.89

76096

220222

... More
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (d) 2000 litre capacity

1

10434

10434

... More
Supplying, fitting and fixing Black Stone slab used in Kitchen slab, alcove, wardrobe etc. laid and jointed with necessary adhesive Cement mortar (1:2) including grinding or polishing as per direction of Engineer-in -Charge in Ground Floor. (b) Slab Thickness above 25 mm and upto 37.5 mm

627.84

713

447650

... More
Supply & fitting of 415 V, 3 Ph, MU-G10W DOL with in-built WLC Pump controller Stater Relay range(9-14) suitable size for 7.5 HP Submersible Pump motor set ( Make - L&T, Model HSN code 8536) on common angle iron frame on wall including nuts bolts etc. including connecting wire.

2

5600

11200

... More
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) b) Premium 100% Acrylic Emulsion .

3899.58

84

327565

... More
Supplying, fitting, fixing in position reinforced cement polyster concrete manhole/ gully pit cover with matching frame as per is 12592(M.D.) Underground Reservior 35 M.T load bering capacity round manhole cover provided with two lifter hooks fitted with matching frame of size

3

4034

12102

... More
A(iii) single Socketed 1.8m length (b ) 110mm

14

293

4102

... More
4 core 35 sqmm

300

408

122400

... More
iii) 160mm Dia.

36

305

10980

... More
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe as to GS.

90

942

84780

... More
Extra for staging beyond 4 m in any floor (Mode of measurement: area in plan x mean height of staging upto soffit of shuttering above initial 4 m)

115.4

58

6693

... More
(b ) 110mm

96

186

17856

... More
2nd Floor

1804.56

85

154146

... More
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.

472.13

24

11331

14

205

2870

... More
20 Users

3

46972

140916

... More
(d) shoe (ii ) 110mm

15

111

1665

... More
Supplying M.S. male / female adopter of approved make and brand for coupling of M.S. pipe and fibre glass strainers, as per direction of the Engineer - in - Charge. (i) 100 mm

7.2

2628

18922

... More
LIGHTNING CONDUCTOR S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. complete duly grouted on the parapet etc. in CC mortar ( 4:2:1), including thimble joints of 7/16 SWG wire and GI strip with SS nuts, bolts & washers.

90

484

43560

... More
Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. (a) Fixed type steel windows as per IS sizes with horizontal glazing bars.

60.48

1508

91204

... More
Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. (iv) 750 mm long

7

117

819

... More
Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws: (iv) 75 x 63 x 3.2mm.

3

62

186

... More
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works 150 mm x 100 mm x 65 mm

240

147

35280

... More
Fourth Floor FCD

6

23423

140544

... More
Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868- 1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2- track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white

233.01

448

104388

... More
Supplying, fitting and fixing Stainless steel Wall Mounted Hinged hand rail (750X100 mm) covered by Nylon surface with contour finish (for better grip) with two brackets. (Model Code No.B2210108 of CERA or equivalent.) 750 mm long

3

6760

20280

... More
Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance 0.5, Mohr's hardness 5.0, Staining resistance: Class-1, Water Absorption: E 0.5%], MOR 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor). b) In Ground Floor: Sizes-600 mm x600mm x10 mm with breaking strength 1500 N

3.16

1581

4997

... More
3rd Floor

7895.31

411

3244972

... More
(b) In 2nd Floor: ( A ) 20 mm THICK PLASTER (6:1) Internal wall

46.7

159

7459

... More
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC.(In Ground Floor)(a) One Coati) Water based interior grade Acrylic Primer ground floor.

94.24

3080

2903

... More
Extra for using approved H.B netting in every third layer in 16 & 17 of subhead A above in any floor

1414.35

41

57988

... More
Second Floor

236.43

1605

379572

... More
A(X) Bend 87.5 Degree (a) 75 mm

24

61

1464

... More
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. In ground floor

286.35

2763

791185

... More
Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department]

754.16

88

66366

... More
4 core 16 sqmm

18

234

4212

... More
Fittings and auxiliaries Supply and Delivery of 240V 50 Hz 48" sweep (1200 mm) ceiling fan complete with down rod,Canopy,fork, Safety wire etc. and Fixing the ceiling fan complete with blades, canopy, fork, rubber bush etc. with 5 years warrenty from OEM (Make- Orient- New Breeze 3 Star or eqv. make & model of USHA/ Crompton)

846

2375

2009250

... More
(d) (i) Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand).

7

815

5705

... More
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc.

315

131

41265

... More
Supply & laying of 2 nos 10SWG GI earth wire alongwith 1.1 Kv grade PVC Ar Al cable including binding by soft GI wire with cable (in three point per mtr)

1170

12

14040

... More
Supply of PVC pipes & fittings (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (A) PVC Pipes. 100 mm

180

874

157320

... More
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (B) Wall. With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of each tile above 0.09 Sq.m. (i) Coloured and decorative In Ground Floor

39.27

1088

42743

600

384

230400

... More
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (ii) Grill weighing above 16 Kg./sq.mtr and above

0.76

9696

7369

... More
Supplying fitting fixing bathroom self of approved make of size 580 mm x 150 mm (porcelain).

78

613

47814

... More
Soft Close seat cover of approved make with lid and C.P. hinges, rubber buffer and brass screws suppling, fitting and fixing complete. E W C (Model Code No. B1520118 of CERA or equivalent.)White

3

1299

3897

... More
Supplying, fitting & fixing C.I. round grating. (ii) 150 mm dia.

201

85

17085

... More
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) One Coat Inside Wall : (i) Water based interior grade Acrylic Primer

2412.85

30

74316

... More
M.S. works in brackets made from flats, angles, tees etc. to sizes specialy bent, twisted, forged; making holes drilled and fitted to rafter of trusses with necessary bolts, nuts, washer or screws etc. (length of straight not less than 230 mm)

16.52

9984

164976

... More
Supplying, fitting and fixing porcelain soap tray of approved make. (i) Recessed soap tray of size 150 mm X 50 mm

180

338

60840

... More
Boundary Wall Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.

1500

10

15000

... More
b) Indicating LED Lamp with colour glasses showing (Red/Yellow/Blue/Amber) (Siemens cat.no 3SB5285-6HC03, 3SB5285-6HD03, 3SB5285-6HF03 or equivalent cat of L&T/ABB/ SCHNEIDER) - 1 No. c) 200/5 Amp ratio C.T (Kappa or equivalent) --- 3 nos. d)S & F 2 Amp SPMCB for auxiliary supply to meters (Make- SIEMENS/L&T/Legrand) - 1 no. Interconnection :- All interconnection between incoming main to Busbar are to be made with suitable size electrolytic tinned copper bars or equivalent flexible pvc insulated multistranded single core Cu cable and the same between busbar to each outgoing mains and & for metering arrangements are to be made by suitable size of Copper with proper socketing of the end of each wire leads. Earthing Arrangement :- A separate continuous aluminum earth busbar of appropriate size is to be painted at the inside bottom of the panel and run across the full load of the panel board. All electrical equipment are to be properly earthed with suitable size G.I. strip. The complete panel board is to be spray painted after required surface treatment by 7 tanks process / sand blasting with 2 coat of red oxide primer & 2 coat of finished paint over dried or powder coating. Installation :- The complete panel board is to be installed on suitable brick padestal as directed by the E.I.C.

4

59176

236704

... More
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.

99.73

24

2393

... More
b) Separate plug.( Avg run 7.5mtr)

10

1274

12740

... More
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white) In Ground floor

127.8

79

10096

... More
Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core

20

44

880

... More
Fire Extinguishers FIRE EXTINGUISHERS Supply & fixing of 5 Kg dry power extinguisher consisting of welded MS cylindrical body with discharge valve, nozzle & CO2 cartage and hanging arrangement complete conforming to IS:2171

375

2775

1040625

... More
Third Floor

4.97

76696

380949

... More
Supplying, fitting and fixing bib cock / stop cock - (a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand).

6

539

3234

... More
Reinforcement for reinforced concrete works in all sort of structure including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction.SAIL/TATA/RINL (a) In Ground Floor:

31.41

55566

1745080

... More
(b ) 110mm

66

120

7920

... More
Sub total

-

-

-

... More
(vi) 32 mm dia

2

1160

2320

... More
25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification

1000.23

191

191204

... More
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. (viii) 100mm. X 75mm. X 3.50mm.

2784

66

183744

... More
xiii) Cross Tee (a) 75 mm

24

145

3480

... More
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three ) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-incharge. Weight of Strainless Steel railing per metre 6.5 Kg (approx)

68.25

9077

619505

... More
(vii) 25 mm dia

21

778

16338

... More
Reinforcement for reinforced concrete works in all sort of structure including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. (a) In Ground Floor:

28.43

55566

1579824

... More
Extra for fluted, corrugated or ribbed plaster (over rate of corresponding rate of plaster). (Cement 0.135 Cu.m/100Sq.m)

201.11

39

7843

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. a) Pakur Variety

82.77

5168

427816

... More
250 mm th. Autoclave aerated concrete block Work with size 625 mm x 250 mm x 125 mm- Grade-I, having drying Shrinkage less than 0.05% conforming to IS: 2185 (Part-3)-1984 made up of fly ash (conforming to IS: 3812-1981, with permissible loss on ignition upto 6% ), lime , cement and laid in Cement Mortar (1:6) complete in all respect as per direction & satisfaction of Engineer -in Charge .

8.9

5809

51716

... More
In First Floor

536.77

5920

3177939

... More
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per elevant IS codes. (i) Pakur Variety

257.13

5666

1457151

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] With 1:4 cement mortar. 15mm thick. Outside Plaster Ground Floor

322.06

148

47742

1080

292

315360

... More
Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white

47.52

448

21289

... More
Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria.(ii) 66mm x 90mm

4.95

497

2460

... More
4th Floor

4046.79

34

138562

... More
a) (i) CP Pillar Cock - 15 mm. (Equivalent to Code No. 507 & Model Tropical / Sumthing Special of ESSCO or similar brand).

6

555

3330

... More
(c) Depth of excavation for additional depth beyond 3000 mm. upto 4000mm. excluding cost of shoring as necessary

1.69

23470

396

... More
(b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.

40.66

19238

7822

... More
Brick work with 1st class bricks in cement mortar (1:6). (a) In foundation and plinth

39.35

5095

200500

... More
Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required.

4

7538

30152

... More
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.

59.68

24

1432

... More
1st Floor

3.21

9792

31465

... More
Laying only Cable above 50 sqmm but not exceeding 400sqmm through existing RCC/ Hume/GI Pipe/open masonary trench for single, 2, 3, 3½ and 4 core

20

62

1240

... More
In First Floor

7.02

3006

21103

... More
M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge. In ground floor.

13.44

10090

135610

... More
Tube Well (2 Nos) Labour for boring through any type of soil for sinking tube well of required dia. with top enlargement by rig boring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes, strainers, blind pipes etc. complete. (a) For depth upto 250 metre for 100 mm dia. Tube well with top enlargement of 200 mm dia.(upto 50 metre). .First 50 metre

100

1014

101400

... More
Brick work with 1st class bricks in cement mortar (1:6) (b) In superstructure, ground floor

89

5317

473217

... More
125 mm thick Autoclave aerated concrete block Work with size 625 mm x 250 mm x 125 mm- Grade-I,having drying Shrinkage less than 0.05% conforming to IS: 2185 ( Part-3)-1984 made up of fly ash (conforming to IS: 3812-1981, with permissible loss on ignition upto 6%), lime , cement and complete in all respect as per direction & satisfaction of Engineer -in Charge . In Ground Floor

1141.65

734

839044

... More
Sequrity Goomty Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.

50

10

500

... More
Pre-Constructional Anti-termite measures: (c) Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable ncentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS-6313 (part -II) 1981. ( Mode of measurment will be per Sq.m of plan area of plinth treated.)

360

81

29160

... More
(b) In 1st Floor: ( A ) 20 mm THICK PLASTER (6:1) Internal wall

480.14

155

74772

... More
Sub Total for Civil Works=

-

-

-

... More
2nd Floor

19.11

6345

121248

... More
Neat cement punning about 1.5mm thick in wall,dado, window sill,floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.

450

32

14742

... More
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish ,2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC incl.3 nos. (Ph, N & Earth bars) i)Avg. Run 8 mtr.

2016

1126

2270016

... More
(b ) 110mm

52

21

1092

... More
Add Labour Welfare Cess @ 1% on Total amount over Item No. 1 to 437.2

298873214

1

2988732

... More
Anodised aluminium grip handle with base plate of approved quality fitted and fixed complete. (iii) 300mm grip x 20mm dia rod x 50mm plate x 3.2mm thick.

24

208

4992

... More
Supplying, fitting and fixing urinal flush pipe fittings of approved brand. (a) CP urinal flush pipe fittings range of one.

90

414

37260

... More
M.F. suspended ceiling made with 12.5 mm thick Gypsum plaster board including G.I. perimeter channel of 0.55 mm flush (having two flanges 20 mm and 30 mm respectively and web 27 mm ) along with perimeter of ceiling with G.I. intermediate channel of 0.9 mm thick size 45 mmx15mm placed at 750 mm c/c with G.I. ceiling angle of size 25 mmx10mmx0.55 mm thick fixed to the ceiling with G.I. Cleat and steel expansion fastener ceiling section 0.55 mm thick of size 51.50 mmx26mm fixed to the intermediate channels with the help of connecting clip and in the direction of perpendicular to the intermediate channel of 300 mm c/c 12.5 mm thick Gypsum plastered board are to be fixed under ceiling section as above by machine screws. The boards are to be joined and finished with jointing compound, paper tape and application of top coat etc. as per the direction of Engineer-in-charge. (The rate includes of cost of all materials including taxes, cost of accessories, fittings and fixtures, scaffolding and labour charges etc. complete) In Grond Floor

501.99

1159

581806

... More
Sub Total

-

-

-

... More
First Floor FCD

6

22748

136489

... More
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement. (ii) 25 mm. thick Ground Floor iii) 35mm Thick

265.41

321

85234

... More
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) ii) Luxury Quality ground floor.

792.95

70

55507

... More
Third Floor

2664.42

1295

3450717

... More
Third Floor

897.12

1103

989918

... More
In 2nd Floor

3.37

56426

189877

... More
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Angle iron Frame) a) 200A Supply and installation of L.T. cubical type fully compartmentalized distribution panel board, having rigid and self supporting structure fabricated with 14 SWG CRCA sheet with M.S. angle iron frame (main frame with 50 x 50 x 6 mm angle and each vertical compartment with 40 x 40x6 mm MS angle iron). The base of panel should be made with 75mm x 40mm x 4.4 mm M.S. channel. [Manufacturer/Fabricator having Test Certificates from CPRI]. An Auto Cad Drawing of the panel has to approved by EIC before making of panel. [NS] Construction Details : All incoming & outgoing switches are to be housed in respective compartments hinged and gasket doors at the front. All doors should have panel locking arrangement in such a fashion that it can not be on unless the feeder remains in off position. The rear panel should gasketed wire net guard for ventilation arrangement will be made of easy accessibility to each compartment by providing rear panel doors with locking system . The panel is to be properly gasketed to prevent the dust & vermin. All vertical bus bar chambers is to properly arrange and all electrical equipments are to be fixed by nuts and bolts on suitable Hylam board / porcelain insulators of adequate size and dimension. The outgoing feeder connection from respective switches are to be made at rear side of panel by means of busbar, copper multi core cables, to be terminated on bolted type terminals for cable connection or on bush insulators for bus bar connection. Each compartment will be providing with DMC/FRP board at back side. Incoming Arrangement :

4

4118

16472

... More
(f) Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar).

93

1251

116343

... More
First Floor

46.86

5761

270006

... More
Electric Sub-Station Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.

742.31

10

7423

... More
Fourth Floor

4046.79

164

664645

... More
(a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification

18

88

1584

... More
iii) 160mm Dia.

469.8

485

227853

... More
SITC of Electrical Panel Building Panel for Block A, B & C : Pump Room Panel : SITC of LT,Industrial Type,Floor cum wall Mounted , electrical control panel on angle iron frame suitable for operation at 415 Volt, 50 Hz,as per size, as per detail specification below. [ All main switch & accessories will be Legrand / Siemens / Schneider Electric / L&T /ABB Make and as per manufacurers standard ]. BUSBAR: Aluminium bus bars of capacity 200 Amps ( 4 nos BAR size 50mm x 5 mm ) -1 Set INCOMER : (i)415V, 125A, online change over switch having front operated handle. - 1 Nos (ii)415V, 125A, TPN SFU with 3 nos 125A HRC fuses having front operated handle. - 1 Nos OUTGOING : (i)415V, 63A, TPN SFU with 3 nos 63A HRC fuses having front operated handle -3 nos. CONTROL & ACCESSORIES: (i) 0-500V Digital Voltmeter with builtin selector switch - 1 no. (ii) 0-100A Digital Ammeter continous rating with selector switch & 3 nos CTs - 1 no. (iii) 3 nos. phase Indication lamps LED type in RYB colours with 3 nos. of 2 Amps back up HRC fuse or SPMCBs 10 kA breaking capacity, as per standard practice - 1 Set

1

76744

76744

... More
At First Floor

253.04

152

38523

... More
M.S. works in brackets made from flats, angles, tees etc. to sizes specialy bent, twisted, forged; making holes drilled and fitted to rafter of trusses with necessary bolts, nuts, washer or screws etc.

0.37

9984

3704

... More
Fourt Floor

102.09

1816

185395

... More
Supplying, fitting &fixing Closet seat of approved make with lid and C.P. hinges rubber buffer and brass screws supplied, fitted & fixed complete. (a) E.W.C. (iv) Bestolite (solid type) white

87

715

62205

... More
Supplying fitting and fixing 600 mm ( ±30 mm) diametre R.B.T (Reinforced Barbed Tape) Concertina fencing on wall top using concertina coils stretched to approx.6 meters length at site clipped with two nos. of horizontal R.B.T strands which will be tensioned and fixed with the vertical M.S angle iron posts by means of security fasteners (such as 'C' clips, R.B.T clips etc.)

750

408

306000

... More
(f) Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar).

4

1251

5004

... More
First Floor

897.12

1093

980947

... More
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1500 mm.

252.64

11927

30132

... More
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) With earth obtained from excavation of foundation.

195.33

7754

15146

... More
Supplying, fitting and fixing C.P extension pipe

279

106

29574

... More
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (a) One Coat ( a) In Ground Floor (One coat):

276.11

31

8670

... More
(vii) 25 mm dia

1

778

778

... More
Neat cement punning about 1.5 mm thick in wall, dado, window sills, floor, drain etc.

913.97

32

29942

... More
Cutting hole through wall, roof or cornice and mending good all damages

16

68

1088

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes. Pakur variety

1.16

4931

5720

... More
240 mm x 200 mm x 65 mm

20

69

1380

... More
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (A) For Exposed work PVC Pipes 15 mm

12

101

1212

... More
Supply & fixing GI (Hot Dip) strips 25 mm x 6 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to building works, including welded lap joints, 'T' joints, etc. and painting the joints with 2 (two) coats of bituminous paint. (P-J1/Item-9)

1800

174

313200

... More
Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. In ground floor.(c) Area of each Granite slab above 1.00 Square meter

51.39

2994

153870

... More
Pre-Constructional Anti-termite measures: (d) Treatment to the back filling of R.C.C. foundation with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight at the rate of 7.5 ltr. per sq.m. of the vertical surface of the substructure of each side of the foundation. The work shall be carried out as per specification as described in para 6.3.1 of code IS6313 (part-II) 1981 (Mode of measurement will be per sq.m. of vertical area of foundation treated).

317.21

94

29818

... More
Third Floor

7895.31

132

1046523

... More
Pre -Constructional Anti - termite measures :- Antitermite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing imdacloprid emulsifiable concentrates ( 105ml in 50 liters ) with water at the rate of 5 litres per sq.m of the surface before sand bed or sub-grade is laid. hole upto 50mm to 75mm deep at 150mm centre to centre bothways shall be made with 12mm dia mild steel rod on the surfaces to facilate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in 7.2.3 of code IS-6313 (part-II) 2013. ( Mode of measurement will be plan area of plinth treaded ) Ground Floor

2996.77

81

242738

... More
Brass hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. 300mm long.

3

657

1971

... More
With carried earth arranged by the contractor within a radius exceeding 5 km. but not exceeding 10 km. including cost of carried earth.

4709.79

49179

2316228

... More
Supplying, fitting & fixing UPVC pipes AType and fittings conforming to IS:13592- 1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/ Bitumen/M-Seal etc) complete. (ii) 110mm Dia

30.6

251

7681

... More
Above 35 sqmm to 95 sqmm at an average depth of 100 mm in floor/pavement/wall etc.

130

164

21320

... More
In Fourth Floor

1081.62

782

846844

... More
Supply and lowering of 3HP 3 phase 415 V submersible Pump motor set of 2900 R.P.M. 40 mm dia having provision of coupling pump with motor capable to discharge 8500 LPH clear sand free water at total head of 90 mtr(Make-KSB model 7c/15)

2

40110

80220

... More
Cement concrete with graded stone ballast (40 mm size excluding shuttering) (A) In ground floor.(Pakur Varity) (a) 6 : 3 : 1 proportion.

27.51

5079

139720

... More
Extra for using approved H.B netting in every third layer in 16 & 17 of subhead A above in any floor

25.2

41

1033

... More
(i) Door stopper.(Brass)

696

117

81432

... More
First Floor

1.92

5761

11080

18

177

3186

... More
Providing & fixing 6.8 Kg CO2 type (ISI marked) extinguisher including all accessories with wall bracket & raw plug confirming to IS:10204

70

12750

892500

... More
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white) In Ground floor

17.88

79

1413

... More
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.

5

161

805

... More
125 mm depth, 100 mm dia

20

100

2000

... More
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials

2.52

1304

3286

... More
(B) Filling in foundation or plinth by Fine sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)

195.77

59961

117386

... More
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials

22.68

1304

29575

... More
3rd Floor

1804.56

86

155427

... More
d) shoe

6

111

666

... More
S & D of bulk head light fitting with all accessories on wall/ceiling. (Make:- Philips-WT140W LED7S CW PSU S1 PC or equivalent to Crompton/ wipro/ Havells)

4

599

2396

... More
4 core 50 sqmm

480

529

253920

... More
4th Floor

4046.79

86

351423

... More
Supplying, fitting and fixing Half round channel with or without outlet as required set in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid seperately) (i) 600 mm X 100 mm). (b) White vitreous chinaware

120

466

55920

... More
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. Pakur Variety. Ground Floor

25.06

5666

141992

... More
Fire buckets round bottom type enamel painted, white inside & Red out side and Letter "FIRE" in black out side and handle with mounting bracket.

12

1350

16200

... More
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC.(a) One CoatIn ground floor.

49.14

3140

1543

... More
Making holes on RCC ceiling 125 mm depth having dia of following sizes : 125 mm depth, 50 mm dia

10

65

650

... More
ii) Length above 0.5 Mtr

500

167

83500

... More
(d) In Third Floor: ( A ) 20 mm THICK PLASTER (6:1) Internal wall

5545.95

163

908038

... More
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. Including using of approved putty etc. On the surface if necessary. With Super Gloss (hi gloss) Two coats ( with any shade except white) (a) WOODEN - SURFACE

15.5

81

1256

... More
Supply & Delivery of 4 feet Industrial box type Twin LED fitting including S &D of 2X 18/20 wattt LED tube with glare free light distribution with CCT (5000K-6500 K) , with minimum luminious efficacy ≥105 & 120 lumen/watt or better. The LED Lamp and accessories shall have BEE Certification with 3 years warrenty [Make Philips TMC 502 2XT-LED 22W with Mas LED Tube 1200mm 18W865T8 I-2100 lm or eqv. make & model of Crompton /Wipro]

145

1320

191400

... More
Supplying, fitting and fixing Orissa pattern water closet in white glazedvitreous chinaware of approved make in position complete excluding 'P' or 'S' trap (excluding cost of concrete for fixing) 580 mm X 440 mm CERA / HINDWARE Ground Floor

3

1613

4839

... More
Faculty Resident Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.

581.46

10

5815

... More
Constructing Inspection pit of inside measurement 600mm X 600mm X up to 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling,15 mm thick (1:4) cement plaster to inside walls and out-side walls up to G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements up to 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make applied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all orts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. i) With Pakur variety Stone Chips with using Steel:- SAIL/TATA/RINL

6

7028

42168

... More
Supplying, fitting & fixing UPVC pipes AType and fittings conforming to IS:13592- 1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/ Bitumen/M-Seal etc) complete. (ii) 110mm Dia

7.8

251

1958

... More
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. (iii) 630 mm X 450 mm size

6

3260

19560

... More
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) ii) Luxury Quality ground floor.

94.24

70

6597

... More
Making V-groove line ( 12 mm wide,12 mm deep) in plastered surface.

567

580

3289

... More
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.

4

1015

4060

... More
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (i) Grill weighing above 16 Kg./sq.mtr and above (a) In Ground Floor:

0.65

9696

6283

... More
(b ) 110mm

96

312

29952

... More
Supplying, fitting and fixing gunmetal wheel valve of approved brand bearing I.S.I. marking with fittings. (tested to 21 kg per sq.m.) (iv) 50 mm dia

18

2277

40986

... More
Supplying, fitting and fixing heavy type bell mouth reducing socket. (iii) 100 mm X 150 mm

2

616

1232

... More
Excavation of soil for installation of Earth Electrode and filling & ramming. (For morrum soil)

36

295

10620

... More
Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. In ground floor.(c) Area of each Granite slab above 1.00 Square meter

7.02

2994

21019

... More
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation. Using concrete mixture. M 25 Grade. Using Pakur Variety stone chips 1) Ground Floor

91.71

6155

564536

... More
Supplying, fitting & Fixing EWC (Size- 710x370x810 mm)in white glazed vitreous chinaware of approved make supplying, fitting and fixing in position complete with necessary nut and bolts. (Model Code No. S10221114-P Trap (CRUSE SET) of CERA or equivalent.)

3

5446

16338

... More
3rd Floor

913.38

6440

5882533

... More
Extra rate for adding Polyester Fibre anti shrinkage material @ 0.25% by weight of cement [or as per Manufacturer's Specification] as secondary reinforcement to arrest hair crack in concrete including cost of Fibre

22.7

414

9398

... More
(b ) 110mm

4

186

744

... More
4th Floor

4.08

10083

41162

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. SAIL/TATA/RINL Tor Steel Roads/HYSD/Fe415/Fe500/Fe500D Ground Floor

13.66

55566

759156

... More
(d) shoe iii) 160mm Dia.

2

305

610

... More
Supply & laying of Hume pipe of inside diameter 1ft, continous cover length 8 mtr, cutting road & soil , jointing, placing, carring, loading unloading etc and mending good damages as per direction of the EIC.

50

1356

67800

... More
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.

686.7

24

16481

... More
Labour for Chipping of concrete surface before taking up Plastering work. In ground floor.

191.08

21

4013

... More
(iii) 100 mm long X 10 mm Dia bolt.

4

53

212

... More
200 mm x 150 mm x 65 mm

20

218

4360

... More
Supply and fixing in position the signages " FIRE ORDER" contain the following matter on 3 mm thick "Opaque" PVC foam board of computerised cut, PVC non-reflective self adhesive vinyle painted foam board of size 1200 x 1000 mm.

9

2700

24300

... More
4th Floor

2673.56

429

1146959

... More
At Second Floor

430.44

156

67252

... More
(b ) 110mm

2

33

66

... More
Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department]

3501.96

88

308172

... More
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] M 25 Grade (i) Pakur Variety

44.91

6155

276457

... More
Supplying, fitting & fixing Stainless Steel 'D' or 'H' type of size 300 mm x 19 mm tubular Handle with Grade 304, CE certified, marked & conforming to EN - 1154, of approved quality of reputed brand as per direction of Eingineer-inCharge fitted and fixed complete including all incidental charges

36

1571

56556

... More
Supply & Fixing bakelite / perspex top cover on existing Inspection board by Brass screws 150 mm x 100 mm x 65 mm

240

36

8640

... More
Supplying, fitting & fixing M.S. clamp for fixing door and window frames, end bifurcated including cutting brick work, fixing in cement Conc.with stone chips (4:2:1) fitted and fixed as per direction and mending all damages complete. (a) 40 mm X 6 mm. 250 mm length

2904

29

84216

... More
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC.(a) One CoatIn ground floor.

639.65

3140

20085

... More
2nd Floor

0.81

9890

8012

... More
Second Floor

1804.56

156

281944

... More
Laying of cable as below, on existing Cable Tray or existing angle iron frame and binding with suitable size GI wire . From 70sqmm to 150sqmm

20

15

300

... More
A(v) Double Socketed 1.2m length (b ) 110mm

16

322

5152

... More
Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws: (iv) 75 x 63 x 3.2mm.

540

62

33480

... More
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (ii) Grill weighing above 16 Kg./sq.mtr and above Ground Floor

3.86

9696

37388

... More
Under Ground (b ) 110mm

18

84

1512

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (f) 25 mm to 30 mm shuttering without staging in foundation Ground Floor

45.73

203

9283

... More
(b ) 110mm

130

292

37960

... More
Power Distribution board Supplying and fixing 415 V, 16-32A per way, 4 Way Vertical TPN MCBDB with provision for FP MCCB as incommer and TP MCB as outgoing in suitable enclosure with metal door comprising of the following :- a) 125 A, 35KA, 4 pole MCCB -- 1 No b) 63A TP MCB --4Nos. c) Cable end box-- 2nos (Make-Legrand 607913 or eqv. make and model of / Schneider/ Siemens.)

2

25377

50754

... More
Third Floor

312.09

1804

563010

... More
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. In wallWith Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of each tile above 0.09 Sq.m(i) Coloured decorative

14.03

1088

15271

... More
(b) Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. (No Departmental Cement is required)

913.97

257

234890

... More
Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc Above Ground (b ) 110mm

38

57

2166

... More
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

381.58

344

131264

... More
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof. i) For roof truss works b) Span beyond 12 Mtr and up to 20.00 Mtr

9

75453

679077

... More
Providing and fixing bell plug as required upto 250 mm (internal) dia. ERWMS pipe including cost of materials and labour complete.

2

431

862

... More
Direction and Place Identification Signs with size more than 0.9 sqm size Board. Providing and erecting direction and place identification retro- reflectorised sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision)

9

9356

84204

... More
In Fourth Floor

134.48

6253

840943

... More
(b)Priming one coat to steel or metal surface with synthetic enamel / oil bound primer of approved quality including smoothening surface by sand papering etc.

8.78

29

255

... More
Internal Road Box cutting or filling in Road embankment in all sorts of soil including spreading the spoils properly over the flank as necessary or on berm to approximate grade & camber and rolling the sub-grade with power roller to proper camber and grade as per direction and satisfaction of Engineer-in-charge including uprooting and removing plants and jungles when and where necessary. (a) Depth beyond 150 mm upto 300 mm

3471.3

33

115941

... More
Supplying fitting and fixing steel rolling grills link type, shutter with 18 B.G .of approved type steel to the section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete.

34.56

2833

97908

... More
Supplying dividing strip fitted and fixed with cement mortar (1:3) in mosaic or patent stone floor, dado etc. complete as per direction of the Engineer-in-charge. (i) Glass - 3mm. Thick. (a) 20 mm. wide strip.

62.4

17

1061

... More
Supplying, fitting and fixing towel rail with two brackets. (a) CP over brass (iii) 25 mm dia rod and 750 mm long.

171

475

81225

... More
240 mm x 200 mm x 65 mm

20

261

5220

... More
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

596.8

344

205299

... More
In 4th floor

48.83

57286

2797035

... More
Anodised aluminium grip handle with base plate of approved quality fitted and fixed complete. (iii) 300mm grip x 20mm dia rod x 50mm plate x 3.2mm thick.

1356

208

282048

... More
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 2.5 sq.mm.

240

6

1440

... More
(b) In 2nd Floor: ( A ) 20 mm THICK PLASTER (6:1) Internal wall

5545.95

159

885855

... More
iii) 160mm Dia.

36

507

18252

... More
B(XV) Vent Cowl (a) 75 mm

2

25

50

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work Foundation Ground Floor

307.68

357

109842

... More
Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. In ground floor. (In case of non-supply of single plank, penal rate of reduction of 20% will be made) (i) 50mm thick shutters with 25mm thick panel of size 30 to 45 cm (a) 1st class best Indian teak.

40.32

6288

253532

540

205

110700

... More
Cutting Channel of following size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 3 mm thick Polythene pipe (without earth continuity wire) by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles incl. S&F of following pipe 19 mm dia pipe (40 mm x 40 mm)

7800

65

507000

... More
Filling the gap in between aluminium frame & adjacent RCC / Brick/ Stone work by providing weather silicon sealant over 6mm dia backer rod of approved quality as per architectural drawings and direction of Engineer-in-Charge complete. Upto 5 mm depth and 5 mm width

28.8

69

1987

... More
Labour for chipping concrete surface before taking up plastering work. In Ground Floor

1405.86

21

29523

... More
(a) 40 mm X 6 mm. 125 mm length

12

20

240

... More
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.

30

514

15420

... More
ii) With 1:4 Cement Morter c) 10mm Thick Ground Floor

181.34

120

21861

... More
Extra rate for using water proofing and plasticising admixture @ 0.20 % by weight of cement or at manufacture's specified rate) In 3:1.5:1 Concrete

204

119

24276

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. SAIL/TATA/RINL Tor Steel Roads/HYSD/Fe415/Fe500/Fe500D Ground Floor

380.04

55566

21117660

... More
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement. Ground Floor iii) 35mm Thick

24.24

321

7785

... More
In 3rd Floor

152.08

56856

8646576

... More
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) One Coat Inside Wall : (i) Water based interior grade Acrylic Primer

59869.32

30

1843975

... More
(b) Priming one coat to timber surface with synthetic enamel / oil bound primer of approved quality including smoothening surface by sand papering etc.

15.5

38

589

... More
10 sq.mm.

220

11

2420

... More
Supplying bubble free float glass of approved make and brand conforming to IS : 2835 - 1987. (i) 5 mm thick coloured / tinted / smoke glass.

860.76

585

503545

... More
Second Floor

10.66

5856

62441

... More
Supplying solid flush type doors of deluxe decorative (both side) quality, conforming to I:S 2202 timber frame consisting of top and bottom rail and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 27.5mm wide battens places both ways in order to made the door of solid core and internal lipping with teak, mahogony or rose wood approved decorative veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing the shutters in position but excluding the cost of hinges and other fittings in ground floor: (a) 35 mm thick shutters (single leaf)

11.34

3955

44850

... More
S & F MS Angle (trangular form by 40x40 mm angle, sides 2ftx2ft, support suitably welded) support fixed with bullet fastnut in wall, clamp for holding cables, making hole etc. as necy., mending good damages and painting.

40

763

30520

... More
Fixing of single LED tube light fitting attached with the wall with 2 No. “V” type MS clamp whose one side inserted within the wall and other side connected with the suitable size of bolts and nuts incl. S&F"V” type MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. with S & F 2x24/0.20 mm unsheathed stranded 1.5 sqmm copper wire of 0.5mt. length. incl. 2nos mounting kit.

30

127

3810

... More
Filling the gap in between aluminium frame & adjacent RCC / Brick/ Stone work by providing weather silicon sealant over 6mm dia backer rod of approved quality as per architectural drawings and direction of Engineer-in-Charge complete. Upto 5 mm depth and 5 mm width

105.6

69

7286

... More
Supply & fixing of 9 Litre Water type CO2 (ISI marked) extinguisher including all accessories with wall bracket & raw plug conforming to IS:940, stair landing

300

2550

765000

... More
Pre -Constructional Anti - termite measures :- Antitermite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing imdacloprid emulsifiable concentrates ( 105ml in 50 liters ) with water at the rate of 5 litres per sq.m of the surface before sand bed or sub-grade is laid. hole upto 50mm to 75mm deep at 150mm centre to centre bothways shall be made with 12mm dia mild steel rod on the surfaces to facilate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in 7.2.3 of code IS-6313 (part-II) 2013. ( Mode of measurement will be plan area of plinth treaded ) Ground Floor

130.59

81

10578

... More
(a) 40 mm X 6 mm. 125 mm length

1080

20

21600

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. SAIL/TATA/RINL Tor Steel Roads/HYSD/Fe415/Fe500/Fe500D Ground Floor

2.52

55566

139806

... More
(i) Door stopper.(Brass)

15

117

1755

20

292

5840

... More
20 mm

18

158

2844

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work Foundation Ground Floor

607.19

357

216767

... More
Cement concrete with graded stone ballast (40 mm size excluding shuttering) (A) In ground floor.(Pakur Varity) (a) 1:3:6 proportion.. In ground floor. (A) [Pakur Variety]

51.5

5079

261591

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] With 1:4 cement mortar. 10mm thick. Ground Floor

10438.8

120

1258397

... More
Extra rate for using water proofing and plasticising admixture @ 0.20 % by weight of cement or at manufacture's specified rate) In 3:1.5:1 Concrete Note : Payment on volume of (3:1.5:1) Concrete.

149.16

119

17749

... More
Brass hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. 300mm long.

363

657

238491

... More
First Floor

9.62

1593

15329

... More
M.S. works in brackets made from flats, angles, tees etc. to sizes specialy bent, twisted, forged; making holes drilled and fitted to rafter of trusses with necessary bolts, nuts, washer or screws etc.

14.69

9984

146645

... More
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. Including using of approved putty etc. On the surface if necessary. With Super Gloss (hi gloss) (b) STEEL SURFACE

8.78

79

694

... More
First Floor

2095.44

152

319010

... More
Supplying and fixing 250 V, 6-10A per way, (2+8)SPN MCBDB with SS enclosure double-door with IP-42/43 protection with DP Isolators as incomer and SPMCBs ('C' Curve, 10kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment, 1no. 40A DP Isolator, 12 no. 6-16A SPMCB). (Make -Legrand 607711 or eqv. make & model of Schneider/ Siemens).

6

3446

20676

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. a) Pakur Variety

47.21

5168

244016

... More
(b ) 110mm

4

206

824

... More
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)

10

249

2490

... More
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

432

344

148608

... More
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) ii) Luxury Quality

2412.84

70

168899

... More
e) 4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC (From VTPN DB to HTPN DB)

1200

819

982800

... More
25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface). [Note: - Waterproofing as per item NO 60, polymer based paint as per item 59 (a) of Section (C).

22.41

191

4284

... More
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation. Using concrete mixture. M 25 Grade. Using Pakur Variety stone chips 1) Ground Floor

1902.03

6155

11707737

... More
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. Pakur Variety. Ground Floor

1.92

5666

10898

... More
2nd Floor

49.05

9889

485130

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. a) Pakur Variety

5.96

5168

30806

... More
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. asrequired and mending good damages No. 4 SWG

200

19

3800

... More
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white) In Ground floor

70.75

79

5589

... More
First Floor

36.38

1780

64756

... More
Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868- 1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2- track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white

5487.48

448

2458391

... More
(b) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. In Ground floor

119.88

29

3477

... More
c) Bend 87.5 degree

2

160

320

... More
Extra for fluted, corrugated or ribbed plaster (over rate of corresponding rate of plaster). (Cement 0.135 Cu.m/100Sq.m)

2585.84

39

100848

... More
(b) Chromium plated Rose shower with revolving joint and 150 mm long shower arm (Equivalent to Code No. 5489 & Model - Florentine of Jaquar or similar brand).

2

1412

2824

... More
In Second Floor

108.76

758

82542

... More
M.S. works in brackets made from flats, angles, tees etc. to sizes specialy bent, twisted, forged; making holes drilled and fitted to rafter of trusses with necessary bolts, nuts, washer or screws etc.

30.05

9984

300019

... More
Supplying, fitting and fixing waste fittings complete a) C.P over brass (ii) 32mm

183

190

34770

... More
Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc.(a) With 'P' trap.CERA / HINDWARE

4

1421

5684

... More
In First Floor

1173.9

746

876833

... More
(b) Priming one coat to timber surface with synthetic enamel / oil bound primer of approved quality including smoothening surface by sand papering etc.

814.41

38

30948

... More
Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality.

2

2235

4470

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. SAIL/TATA/RINL Tor Steel Roads/HYSD/Fe415/Fe500/Fe500D Ground Floor

40.37

55566

2243182

... More
Supplying, fitting and fixing approved brand 32mm dia. Waste pipe (iii) 900mm long

8

75

600

... More
(d) In Fourth Floor: ( A ) 20 mm THICK PLASTER (6:1) Internal wall

451.56

167

75740

... More
Making V-groove line ( 12 mm wide,12 mm deep) in plastered surface.

8909.1

580

51673

... More
Second Floor

2664.42

1283

3418744

... More
Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-incharge including cost of all materials labour and equipment complete.

16

2029

32464

... More
1st Floor

7895.31

375

2960741

... More
Supplying, fitting and fixing waste fittings complete a) C.P over brass (ii) 32mm

8

190

1520

... More
Making V-groove line ( 12 mm wide,12 mm deep) in plastered surface.

164.6

580

955

... More
Second Floor

46.86

5856

274458

... More
PLUG & SOCKETS( Modular) Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.

5

1742

8710

... More
6 sq.mm.

500

9

4500

... More
(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) (B) Do - by fine sand

122.05

599

73182

... More
SITC of LT Feeder Piller Box dust and vermin proof panel board of suitable size made out of 3 mm thick CRC sheet with febricated structure by 50x50x6mm angle in both side hinged door and providing suitable ventilation arrangement including all structural works for housing the internall accessories and painting with one coat of R.O. Primer and two coat of synthetic enamel paint incl. interconnection with suitable copper strip / copper conductor of appropriate capacity and earth stud both in the body complete with all accessories on CC foundation (3:2:1) as to GS comprised with following switches as per direction of EIC INCOMING 400A TPN SFU with 3 Nos DIIN type HRC Fuse -1 Sets Bus Bar: 500A, Aluminium Busbar -4 Nos OUTGING: 200A TPN SFU with 3 Nos DIIN type HRC Fuse - 4 Sets Supply & fixing of 400A Porceline Fuse Cutout 3 nos. with Neutral Link The Feedre Pillar should be complete including necessary connections, grouting properly, Lock and key system, danger board, interconnection with PVC insulated armoured cable of appropriate sizes. All cables, conduits, flexible conduits should be neatly laid and armoured should be finished properly as per GS. The Degree of IP protection for the enclosure will be IP-56.It will have multi tier arrangement, with sufficient no. of channels base structure by 75x40x4.4mm channel.[Design & Drawing of pillar and make of accessories to the approved before fabrication]. (This Feeder Piller Box should also accomodate WBSEDCL Supply connection too.)

1

155000

155000

... More
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.

1640.19

24

39365

... More
125mm thick brick work with 1st class bricks in cement morter (1:4) Ground Floor

119.34

697

83240

... More
1st Floor

10.21

55996

571466

... More
Brick work with 1st class bricks in cement mortar (1:6) (b) In superstructure, ground floor

14.8

5317

78692

... More
Wet Mix Macadam Base Course Providing,laying,spreading and compacting graded stone aggregate(Pakur variety) to Wet Mix Macadam Specification including screening of aggregates and granular materials, premixing the material with water at OMC in Wet Mix Plant, carriage of mixed material by tripper to site. laying in uniform layers wilh Paver in Sub- base / Base course on well prepared surface and compacting wilh Vibratory Roller to achieve the desired density, including supply of all materials, machinery, fuel ond lubricants, including incidental costs for lighting guarding, barricading, making earthen bundh to protect the edges including cost of quality.control complete as per Clouse 406 of Speclficolions for Rood & Bridge Works of MoRT&H (5th Revision)' (payment will be made on the basis of finished compacted volume)

867.83

2616

2271089

... More
S & D of 240 V 50 HZ 18" (450 mm) high flo oscillating type metal body Wall Bracket fan operated by pull cord switch with inbuilt regulator (Make -Orient, model- Tornado Wall II-Gun Metal or eqv. Make & model of Crompton)

6

3976

23856

... More
Cable for Distribution Board and other Auxiliaries Supply & Delivery of following size 1.1 kv.gr.XLPE insulated 1100V Grade as per IS 7098 (part 1) 1988 armoured sheathed Aluminium conductor cable. [Make - Havells / RR / Polycab] 4 core 150 sqmm

650

1253

814450

... More
Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP) (a) 3mm thick (0.25mm Al.+2.5mm LDPE +0.25mm Al. PVDF coating)

150

1991

298650

... More
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

175.34

344

60317

... More
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Meter Length 75mm

20

196

3920

... More
Neat cement punning about 1.5mm thick in wall,dado, window sill,floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.

306.46

32

10040

... More
A(vi) Double Socketed 0.9m length (a) 75 mm

7

226

1582

... More
Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance 0.5, Mohr's hardness 5.0, Staining resistance: Class-1, Water Absorption: E 0.5%], MOR 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only,make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor) (a) Floor: b) In Ground Floor: Sizes-600 mm x600mm x10 mm with breaking strength 1500 N

53.6

1581

84765

... More
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick)

3177.78

122

387689

... More
First Floor

56.38

6250

352423

... More
Boys Hostel (Sanitary and Plumbing Works) Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall up to 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessary specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and refilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials For 100 users i) With Pakur variety Stone Chips with using Steel:- SAIL/TATA/RINL

1

88728

88728

... More
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. Including using of approved putty etc. On the surface if necessary. With Super Gloss (hi gloss) Two coats ( with any shade except white) (a) WOODEN - SURFACE

814.41

81

65967

... More
Extra for fluted, corrugated or ribbed plaster (over rate of corresponding rate of plaster). (Cement 0.135 Cu.m/100Sq.m)

389.95

39

15208

... More
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: (ii) 100 mm grip x 10 mm dia rod.

2

69

138

... More
With 1:4 cement mortar. 15mm thick. Outside Plaster. Ground Floor

143.54

148

21278

... More
(b) Supplying 'Godrej' mortice lock chromium plated with keys 6 levers including fitting & fixing complete.

12

1954

23448

... More
2nd Floor

1804.56

123

222755

... More
Galvanised iron sheet ridging fitted with necessary bolts, screws, washers etc complete.(225mm end lapping. (B) 450 mm lapping each way. (c) With 0.80 mm sheet .

60

593

35580

... More
165mm grip x 12mm dia rod x 42mm plate x 3.2mm thick.

4

147

588

... More
In 2nd Floor

152.08

56426

8581183

... More
(ii) Chromium plated concealed Stop Cock heavy duty (Equivalent to Code No. 5083 & Model - Florentine of Jaquar or similar brand).

78

953

74334

... More
25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface). [Note: - Waterproofing as per item NO 60, polymer based paint as per item 59 (a) of Section (C).

5.5

191

1051

... More
b) 2X 56/0.3( 4 sqmm) + 1 X 36/0.3( 2.5 sqmm) as ECC ( From HTPN DB to AC )

250

98

24500

... More
2nd Floor

430.44

32

14127

... More
Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria. (ii) 66mm x 90mm

9.9

497

4920

... More
Supplying galvanised straining bolts (with eye at one end with double nuts and washers) fitted and fixed complete.(ii) 12 mm. dia. (a) 200 mm

1224

68

83232

... More
Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance 0.5, Mohr's hardness 5.0, Staining resistance: Class-1, Water Absorption: E 0.5%], MOR 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor). b) In Ground Floor: Sizes-600 mm x600mm x10 mm with breaking strength 1500 N

9.62

1581

15213

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work Foundation Ground Floor

2076.06

357

741153

... More
Copal varnish of approved quality including preparing surface : (i) On new wood work : (b) Two coats

104.64

184

19254

... More
B(XV) Vent Cowl (a) 75 mm

54

25

1350

... More
xiii) Cross Tee (a) 75 mm

2

145

290

... More
Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws: (iv) 75 x 63 x 3.2mm.

6

62

372

... More
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete.

75.6

4330

327348

... More
Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm

6

613

3678

... More
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board.

7

178

1246

... More
(v) 40 mm dia

39

1590

62010

... More
Supply & Fixing GI louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) for 23 cm (9") exhaust fan

11

128

1408

... More
Supplying, fitting & fixing C.I. round grating. (ii) 150 mm dia.

11

85

935

... More
Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria. (ii) 66mm x 90mm

892.35

497

443498

... More
iii) 160mm Dia.

34.5

485

16733

... More
Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mm thickness in floor, lobby, stair, landing & treads etc. over 20 mm (av.) thck base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary pigments including grinding and Granite polishing as per direction of Engineering -in -Charge in Ground Floor. {White cement and Pigment to be supplied by the Agency] (b) With Chawk Dungri (iii) Area of each tile exceeding 0.6 sq.m but not excedding 1 sq.m. In Ground Floor

1.44

2700

3888

... More
Supplying and fixing 415 V, 16-32A per way, 6 Way Vertical TPN MCBDB with provision for FP MCCB as incommer and TP MCB as outgoing in suitable enclosure with metal door comprising of the following :- a) 125 A, 35KA, 4 pole MCCB -- 1 No b) 63A TP MCB --6Nos. c) Cable end box-- 2nos (Make- Siemens 8GB31572RC or eqv. make & model of Legrand/ Schneider)

7

27610

193270

... More
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

3165.93

344

1089080

... More
(b ) 110mm

1746

292

509832

... More
Brick work with 1st class bricks in cement mortar (1:4). (a) In foundation and plinth

6.86

5340

36634

... More
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. With angle iron support 300x50x1.25mm (18SWG)

100

378

37800

... More
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m. (i) At Ground Floor

932.5

32

30549

... More
d) Add extra for excavation in morum soil

249.72

2082

5199

... More
Supplying, fitting and fixing 15 mm swan neck tap with left & right hand operating nob with aerator (Equivalent to Code No. 510, 510(A) and Model - TROPICAL / SUMTHING SPECIAL of ESSCO or similar brand).

12

811

9732

... More
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

35.5

344

12212

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work

2575.23

357

919357

... More
S & F compression type brass cable gland complete with brass gland, brass ring & rubber ring for dust & moisture proof entryof XLPE/PVC armoured cableas & Finishing the end of the following XLPE/PVC armoured cableas by crimping method incl. S&F solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials: 4 core 150 sqmm

16

813

13008

... More
Cement concrete with graded stone ballast (40 mm size excluding shuttering) (A) In ground floor.(Pakur Varity) (a) 6 : 3 : 1 proportion.

439.61

5079

2232962

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] With 1:4 cement mortar. 15mm thick. Outside Plaster. At Ground Floor

932.5

148

138234

... More
Labour for chipping concrete surface before taking up plastering work. (a) In Ground Floor:

913.97

21

19193

... More
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. asrequired and mending good damages No. 4 SWG

900

19

17100

... More
Supplying, fitting and fixing G.I. cap at top. (ii) 150 mm

2

503

1006

... More
Supply & fixing of GI (Hot Dip) strips 25 mm x 6 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart incl. mending good damages to building work, including welded lap joints, 'T' joints, etc. and painting the joints with 2 (two) coats of bituminous paint. (P-J1/Item-11a)

3600

216

777600

... More
2nd Floor

1804.56

32

59226

720

177

127440

... More
Cutting hole through wall, roof or cornice and mending good all damages

360

68

24480

... More
B) UPVC Fittings : a) Plain Tee ii) 110 mm Dia.

2

172

344

... More
First Floor

39.27

1093

42939

... More
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.

153.08

11927

18258

... More
(c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work Foundation

698.02

357

249193

... More
Supplying and fixing 250 V, 6-10A per way, (2+12)SPN MCBDB with SS enclosure double-door with IP-42/43 protection with DP Isolators as incomer and SPMCBs ('C' Curve, 10kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment, 1no. 40A DP Isolator, 12 no. 6-16A SPMCB). (Make-Legrand 607712 or eqv. make & model of Schneider/ Siemens.)

94

4518

424692

... More
Supply & Fixing of perforated GI cable tray Tee with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. 300 x 50 x 1.25 mm (18SWG).

20

866

17320

... More
Part-B: ELECTRICAL WORKS

-

-

-

... More
Supplying, fitting and fixing pedestal of approved make for wash basin (white)

2

1497

2994

... More
Supply & Deliver of 4 feet Industrial box type single LED fitting including S & D of 1X 18/20 wattt LED tube with glare free light distribution with CCT (5000K-6500 K) , with minimum luminious efficacy ≥105 & 120 lumen/watt or better. The LED Lamp and accessories shall have BEE Certification. with 3 years warrenty [Make Philips TMC 502 1XT-LED 22W with Mas LED Tube 1200mm 18W865T8 I-2100 lm or eqv. make & model of Crompton /Wipro]

1065

770

820050

... More
(I) Cement concrete with graded stone ballast (40 mm size excluding shuttering In ground floor (A) [Pakur Variety] (a) 1:3:6 proportion

33.11

5079

168201

... More
Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (A) For Exposed Work (ii) 50 mm dia. medium quality

240

540

129600

834

129

107586

642

236

151512

... More
ii) Chromium plated Bib Cock long body with wall flange with aerator (Equivalent to Code No. 512 & Model - Tropical / Sumthing Special of ESSCO or similar brand)

108

659

71172

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] ii) With 1:4 Cement Morter c) 10mm Thick Ground Floor

49.14

120

5924

... More
A(iii) single Socketed 1.8m length (b ) 110mm

186

293

54498

... More
Supplying, fitting and fixing boiling water proof ply conforming to IS: 710-1977 bonded with phenol formaldehyde synthetic resin conforming to IS: 848-1974 of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in-Charge. [excluding the cost of supporting frame work and teak wood batten/Lipping] In Ground Floor (vi) 19mm

100

2420

242000

... More
Pre-Constructional Anti-termite measures: (d) Treatment to the back filling of R.C.C. foundation with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight at the rate of 7.5 ltr. per sq.m. of the vertical surface of the substructure of each side of the foundation. The work shall be carried out as per specification as described in para 6.3.1 of code IS6313 (part-II) 1981 (Mode of measurement will be per sq.m. of vertical area of foundation treated).

115.22

94

10830

... More
(b) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. In Ground floor

127.8

29

3706

... More
Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc Above Ground (b ) 110mm

1544.01

57

88009

... More
2nd Floor

430.44

85

36768

... More
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Meter Length 75mm

294

196

57624

... More
Supplying, fibre glass reinforced Epoxy resin slotted of 1 mm slot width in 6.1m length of approved make and as per direction of the Engineer - in - Charge (a) 100 mm nominal dia (i) 6.00 mm wall thickness

60

1638

98280

... More
First Floor

4.97

76296

378962

... More
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) b) Premium 100% Acrylic Emulsion .

49.14

84

4128

... More
(iii) 100 mm long X 10 mm Dia bolt.

360

53

19080

... More
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials.

2.52

1304

3286

... More
(b) STEEL SURFACE

49.28

79

3893

... More
Supplying and laying true to line and level Tactile Finish Scratch resistant,Neutral to UV rays, Non-fade, High Slip Resistant Full Body Vitrified Tilesconforming to IS:15622-2006 & IS :4457- 2007 and tested in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance: 0.6, Mohr'shardness 7.0, Staining resistance: Class-1, Water Absorption E 0.5%], MOR 38N/sq.mm & Breaking strength 4000 N for Outdoor area of building e. g. Driveway, Pathway, Pavements, Parking lots, Sloping ramps, Entrance lobbies,Patios, Portico, swimming pool enclosure, Bus Passenger Shed & directingvisually impaired persons, set over necessary underlay and 2 mm thick cementslurry at back side of tiles using cement @ 2.91 Kg./Sqm, joints grouted withadmixture of white cement and colouring pigment to match with colour of tilesand removal of wax coating of top surface of tiles with warm water and cleaningthe tiles using soft and dry cloth complete including the cost of materials, labourand all other incidental charges complete including backside slurry butexcluding the cost of underlay and true to the manufacturer's specification anddirection of Engineer-in-Charge. In Ground Floor: Sizes-300 mm x 300 mm x15 mm

36.38

1768

64320

... More
4th floor

289.25

6535

1890351

... More
(d) shoe (ii ) 110mm

2

111

222

14

129

1806

... More
Extra rate for using water proofing and plasticising admixture @ 0.20 % by weight of cement or at manufacture's specified rate) In 3:1.5:1 Concrete

6.57

119

782

... More
1st Floor

49.05

9792

480374

... More
Filling in foundation or plinth by Fine sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)

2156.1

59961

1292819

... More
Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works: i) Length upto 0.5 Mtr

1800

84

151200

... More
Constructing Inspection pit of inside measurement 600mm X 600mm X up to 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling,15 mm thick (1:4) cement plaster to inside walls and out-side walls up to G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements up to 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make applied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all orts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. i) With Pakur variety Stone Chips with using Steel:- SAIL/TATA/RINL

54

7028

379512

... More
Add GST @ 18% on total amount over item No. 1 to 437

253282385

18

45590829

... More
Labour for hoisting plastic water storage tank.(ii) Above 1500 litre upto 5000 litre capacity.At Fifth Floor (d) 2000 litre capacity

30

514

15420

... More
First Floor

236.43

1593

376735

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work Foundation Ground Floor

191.08

357

68216

... More
Supplying and fixing 415 V, 25-32A per way, 6way TPN MCBDB with SS enclosure double-door with IP-42/43 protection with 63A Four Pole Isolators as incomer and 18 non SPMCBs ('C' Curve, 10 kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment, 1no. 63A FP Isolator, 18 no. (25-32A) SPMCB. (Make-Legrand 607716 or eqv. make & model of Schneider/ Siemens.)

28

8002

224056

... More
Supplying wooden moulding slanting beat of size 37mm X 18mm (finished) of approved design to finish the joint between wooden frame of door/window with masonary in true line and level fitted & fixed with adhesive and head less pins complete as per direction of Engineer -in-charge. a) Teak wood beat

11991.9

109

1307117

... More
Supplying, fitting and fixing 15 mm swan neck tap with left & right hand operating nob with aerator (Equivalent to Code No. 510, 510(A) and Model - TROPICAL / SUMTHING SPECIAL of ESSCO or similar brand).

2

811

1622

... More
165mm grip x 12mm dia rod x 42mm plate x 3.2mm thick.

360

147

52920

... More
Brick work with 1st class bricks in cement mortar (1:6). (a) In foundation and plinth

420.47

5095

2142290

... More
Supplying& laying 20 mm designer chequered tiles of any shade and of approved quality as per IS: 1237: 1980 laid in patterns as directed in pavement, footpath including necessary underlay 25 mm thick average cement mortar (1:3) complete in all respect with all labour and materials [using cement slurry @ 4.4 kg/Sq.m at back side of tiles. Cement of mortar & slurry will be supplied by the Department. Border concrete if necessary to be paid separately].

17.72

804

14248

... More
A(vi) Double Socketed 0.9m length (a) 75 mm

54

226

12204

... More
Second Floor FCD

6

22973

137841

... More
In First Floor

171.83

746

128347

... More
Supply &Fixing of 240V 36 watt, recess mounted 2'x2' LED fittings with glare-free uniform illumination, suitable for 2'x2' grid ceiling with CCT ( 5000-6500) & Luminious efficacy ≥105 & 120Lumen/ Watt or better.The LED luminaires and accessories shall have BEE Certification. with 3 years warrenty [Make Philips RC380B LED36S-6500 G6 L60W60 PSU OD S1 or eqv. make & model of Crompton /Wipro

24

2930

70320

100

384

38400

... More
Supplying and laying true to line and level Tactile Finish Scratch resistant,Neutral to UV rays, Non-fade, High Slip Resistant Full Body Vitrified Tilesconforming to IS:15622-2006 & IS :4457- 2007 and tested in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance: 0.6, Mohr'shardness 7.0, Staining resistance: Class-1, Water Absorption E 0.5%], MOR 38N/sq.mm & Breaking strength 4000 N for Outdoor area of building e. g. Driveway, Pathway, Pavements, Parking lots, Sloping ramps, Entrance lobbies,Patios, Portico, swimming pool enclosure, Bus Passenger Shed & directingvisually impaired persons, set over necessary underlay and 2 mm thick cementslurry at back side of tiles using cement @ 2.91 Kg./Sqm, joints grouted withadmixture of white cement and colouring pigment to match with colour of tilesand removal of wax coating of top surface of tiles with warm water and cleaningthe tiles using soft and dry cloth complete including the cost of materials, labourand all other incidental charges complete including backside slurry butexcluding the cost of underlay and true to the manufacturer's specification anddirection of Engineer-in-Charge. In Ground Floor: Sizes-300 mm x 300 mm x15 mm

312.09

1768

551775

... More
Providing 200 mm centre guide.

12

128

1536

... More
Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.

654.08

19238

125831

... More
Turfing with SodsFurnishing and laying of the live sods of perennial turf forming grass on embankment slope, verges or other locations shown on the drawing or as directed by the Engineer including preparation of ground, fetching of sods and watering as per Clause 307 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).

4752

17

81734

... More
Supplying, fitting and fixing stainless sink complete with waste fittings and two coats of painting of C.I. brackets. (b) Sink with drain board 1050 mm X 450 mm X 180 mm

2

5006

10012

... More
Extra cost of labour for prefinished and premoulded Nosing to treads of steps, railing, window sill etc. of Marble Stone.

66.54

258

17167

... More
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation.

102.05

7754

7913

... More
Supplying, fitting and fixing Stainless steel Wall Mounted Grab Bar. Load bearing capacity 150 kg, covered by Nylon surface with contour finish (for better grip) with Anti-bacterial surface complete. (Model Code No. B2210106 of CERA or equivalent.)600mm long

3

1825

5475

... More
(b) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. In Ground floor

17.88

29

519

... More
Supply & Fixing GI louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) for 30 cm (12") Exhaust Fan.

121

161

19481

... More
First Floor

0.34

76296

25941

... More
(v) Plain Y (a) 75 mm

2

102

204

... More
Supplying, fitting & fixing fire resistant door frame conforming to IS:3614, tested and certified as per laboratory approved by Engineerin-charge, of section 143 x 57 mm having built in rebate made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 120 minutes fire rated door shutters. The frame is fitted with intumescent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with back plate bracket and anchor fastener of approved size and make. Rubber door silencers should be provided on striking jamb. Supplying, fitting & fixing fire resistant Door leaf of 46 mm thick fully flush double skin glazed fire resistant door shutters with or without vision lite, of 120 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 18 SWG G.I. sheet (zinc coating not less than 120 gm/ m2) duly filled heat-resistant phenolic resin bonded insulation material (honeycomb craft) and fixing with necessary stainless steel ball bearing hinges of approved make. For pair of doors astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturer recommendation with a beeding and screw from inside. The glass should be 6mm clear borosilicate fire rated glass of relevant rating. All door and frames shall be finished with polyurethene aliphatic grade paint of approved colour including applying a coat of approved brand fire resistant primer. The door leaf and frame shall have passed minimum 250 hours of salt spray test. Rate should include supply and installation complete as per direction of Engineerin-charge. i) 2 hour Fire rated door single leaf of size (1200 mm x 2180 mm) Ground Floor FCD

12

22523

270276

... More
Supply & delivery 240V. 50 Hz. 230 mm. Sweep 920 r.p.m. Heavy Duty AC Exhaust Fan (Make- EPC)

11

2211

24321

... More
Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance 0.5, Mohr's hardness 5.0, Staining resistance: Class-1, Water Absorption: E 0.5%], MOR 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only,make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor) (a) Floor: b) In Ground Floor: Sizes-600 mm x600mm x10 mm with breaking strength 1500 N

129.84

1581

205333

... More
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] (a) Pakur Variety. M25 Grade (a) In Ground Floor:

181.09

6155

1114663

... More
A(v) Double Socketed 1.2m length (b ) 110mm

150

322

48300

... More
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white) In Ground floor

119.88

79

9471

... More
B(XVi) Pipe Clip (a) 75 mm

8

16

128

... More
Fixing only 300 mm exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:

121

339

41019

... More
Supplying, fitting and fixing 18 mm thick marble partition slab with chawk doongri marbel square cut, both sides polished with two front corners rounded and edges polished.

51.84

1426

73924

... More
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) d) 40mm X 6mm, 125mm Length

6

20

120

... More
Earthing with 65 mm dia GI pipe (TATA-Medium) 3.0 Mts. long with welded half circle bracket of GI strip (65 x 8) mm. with two holes on extended portion of the strip of length min. 200 mm , and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. ( NS) --- For LC.

90

4375

393750

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes. Pakur variety

14.34

4931

70714

... More
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. (viii) 100mm. X 75mm. X 3.50mm.

60

66

3960

... More
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. A) UPVC Pipes : iii) 160mm Dia.

6.6

485

3201

... More
Supplying, fitting and fixing C.P extension pipe

12

106

1272

... More
(b ) 110mm

11

324

3564

... More
4th Floor

4046.79

124

505363

... More
1st Floor

2095.44

32

67285

... More
Under Ground (b ) 110mm

771.99

84

64847

... More
(b ) 110mm

4

120

480

... More
Supplying bubble free float glass of approved make and brand conforming to IS : 2835 - 1987. (i) 5 mm thick coloured / tinted / smoke glass.

36.18

585

21165

... More
In Second Floor

14.9

6031

89840

... More
(b ) 110mm

4

312

1248

... More
Pre-Constructional Anti-termite measures: (d) Treatment to the back filling of R.C.C. foundation with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight at the rate of 7.5 ltr. per sq.m. of the vertical surface of the substructure of each side of the foundation. The work shall be carried out as per specification as described in para 6.3.1 of code IS6313 (part-II) 1981 (Mode of measurement will be per sq.m. of vertical area of foundation treated).

2469.65

94

232147

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (f) 25 mm to 30 mm shuttering without staging in foundation Ground Floor

435.48

203

88402

... More
(b ) 110mm

66

206

13596

... More
Extra for using approved H.B netting in every third layer in 16 & 17 of subhead A above in any floor

5586.57

41

229049

... More
First Floor

312.09

1780

555520

... More
First Floor

2664.42

1271

3386771

... More
In First Floor

1.44

2712

3906

... More
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.

90

1015

91350

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] With 1:4 cement mortar. 10mm thick. Ground Floor

698.02

120

84146

... More
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (ii) Grill weighing above 16 Kg./sq.mtr and above

1.56

9696

15126

... More
Bituminous Macadam using Mobile Hot Mix Plant (Light Duty) Providing and laying bituminous macadam with Mobile Hot Mix Plant (Light Duty) using approved crushed aggregates(pakur variety) of specified grading as per Table 500.7 premixed with bituminous binder, transported to site laid over a previously prepared surface at specified laying temperature by means of approved and suitable arrangements to the required grade, level and alignment and rolled with suitable power roller for break down, inter-mediate and finished rolling as per specification to achieve the desired compaction including cost and carriage of stone materials and bitumen, hire charges of machinery and equipment, cost of fuel and lubricants and wages of operational staff, quality control complete as per Specifications for Road & Bridge Works of MoRT&H (5th Revision). B. For Grading 2 (19 mm nominal size, 50-75 mm thick. using Packed Bitumen VG-30 (payment will be made on the basis of finished compacted volume)

173.57

6273

1088846

... More
Supply & Fixing 240 V, 2 nos. 6A, 3 pin Modular type plug socket (Brand approved by EIC) with 2nos. 6A Modular type switch, without plug top on 6 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.

320

758

242560

... More
Supplying, fitting and fixing 10 litre white glazed vitreous chinaware of approve low-down cistern of approved make with either side or bottom inlet, side overflow, brackets complete with all internal fittings. (Model Code No. S1060106 of CERA or equivalent.)White

3

2406

7218

... More
Extra for staging beyond 4 m in any floor (Mode of measurement: area in plan x mean height of staging upto soffit of shuttering above initial 4 m)

230.8

58

13386

... More
Labour for chipping concrete surface before taking up plastering work. In Ground Floor

36798.3

21

772764

... More
Filling the gap in between aluminium frame & adjacent RCC / Brick/ Stone work by providing weather silicon sealant over 6mm dia backer rod of approved quality as per architectural drawings and direction of Engineer-in-Charge complete. Upto 5 mm depth and 5 mm width

2918.7

69

201390

... More
Filling the gap in between aluminium frame & adjacent RCC / Brick/ Stone work by providing weather silicon sealant over 6mm dia backer rod of approved quality as per architectural drawings and direction of Engineer-in-Charge complete. Upto 5 mm depth and 5 mm width

23.4

69

1615

... More
(b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.

226.78

19238

43628

... More
Sealing new expansion joint with Elastomeric Polysulphide Sealant of gap size 50mm X 25mm Including cleaning of the expansion joint thoroughly, mending of edges &surface, placing 50mm dia Backer rod as back up material with the costofmaterials, labours, &all other incidental charges as per manufacturer's specification & direction of Engineer-in-charge

441.15

792

349391

... More
Fixing only Wall fan on wall by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length

6

95

570

... More
Earthing Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as by ISI-Medium GI pipe

12

1410

16920

... More
Supplying, fitting and fixing 15 mm Twin Flush Fitting (Model Code No. B1810112 of CERA or equivalent)

4

1041

4164

... More
Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin roperly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box.

836

179

149644

... More
Granular Sub-base with Graded Material (Table:- 400-1) By Mix in Place Method: : Construction of granular sub-base by providing graded material(pakur variety), mixing in Wet Mix Plant at OMC, carriage of mixed material to work site, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber, compacting with vibratory power roller to achieve the desired density, including lighting, guarding, barricading, including cost of all materials, machinery, tools and plants and cost of quality control complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). (iii) Grading – III (payment will be made on the basis of finished compacted volume)

504.78

2093

1056988

... More
c) Bend 87.5 degree

6

160

960

... More
Labour for hoisting plastic water storage tank.(ii) Above 1500 litre upto 5000 litre capacity.At Fifth Floor (d) 2000 litre capacity

1

514

514

... More
(ii) Chromium plated concealed Stop Cock heavy duty (Equivalent to Code No. 5083 & Model - Florentine of Jaquar or similar brand).

2

953

1906

... More
Laying of cable as below, on existing Cable Tray or existing angle iron frame and binding with suitable size GI wire . above 150sqmm

25

20

500

... More
Expansion joint in floor roof etc. formed with V strips made of 22.5 cm wide strips of 24 gauge aluminium sheets with anchor arm projecting on each side (and end turned ) embedded in adjacent cement concrete, including shaping and finishing the edges on either side of the joint (including the cost of bituminous filler if any) complete as per direction of Engineer-in-Charge.

441.15

325

143374

... More
3rd Floor

49.05

9986

489886

... More
(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) (B) Do - by fine sand

106.03

59961

63577

... More
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC.(In Ground Floor)(a) One Coati) Water based interior grade Acrylic Primer ground floor.

792.95

3080

24423

... More
(A) Extra over the corresponding item of collapsible gate for top hung

75.6

165

12474

... More
Next 50 metre

100

1055

105500

22

236

5192

... More
25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification

32.14

191

6144

... More
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.

527.73

24

12666

... More
4 core 50 sqmm

36

418

15048

... More
125 mm thick Autoclave aerated concrete block Work with size 625 mm x 250 mm x 125 mm- Grade-I,having drying Shrinkage less than 0.05% conforming to IS: 2185 ( Part-3)-1984 made up of fly ash (conforming to IS: 3812-1981, with permissible loss on ignition upto 6%), lime , cement and complete in all respect as per direction & satisfaction of Engineer -in Charge .

8.88

734

6526

... More
Supply and fixing signage with printed " IN CASE OF FIRE, DO NOT USE LIFT. USE STAIRS ONLY" OF 1.5 cm height letters in red with white background. The size of the board shall be 300 x 250 mm and shaall be fixed at the height of 2 mtrs.from finished floor near Manual Call Point.

9

1125

10125

... More
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. (iii) 630 mm X 450 mm size

87

3260

283620

... More
Supplying and fixing 415 V, 25-32A per way, 4 way TPN MCBDB with SS enclosure double-door with IP-42/43 protection with 63A Four Pole Isolators as incomer and 12non SPMCBs ('C' Curve, 10 kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment, 1no. 63A FP Isolator, 12 no. (25-32A) SPMCB.(Make-Legrand 607715 or eqv. make & Model of Schneider/ Siemens.)

7

6155

43085

... More
(B) Filling in foundation or plinth by Fine sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)

126.73

59961

75990

... More
Next 100 metre

60

1091

65460

... More
Brick work with 1st class bricks in cement mortar (1:4). (a) In foundation and plinth

87.39

5339

466656

... More
Supplying wooden moulding slanting beat of size 37mm X 18mm (finished) of approved design to finish the joint between wooden frame of door/window with masonary in true line and level fitted & fixed with adhesive and head less pins complete as per direction of Engineer -in-charge. a) Teak wood beat

78

109

8502

... More
Galvanised iron sheets valley gutter with perimeter not less than 750 mm with 225 mm lap each way fitted and fixed with necessary bolts, nuts, screws, etc.complete. Valley gutter made of 0.63 mm. thick sheets. (300mm End lapping)

120

543

65160

... More
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) With earth obtained from excavation of foundation.

3706.43

7754

287396

... More
(b) For Concealed Work 15 mm

3540

137

484980

... More
Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mm thickness in floor, lobby, stair, landing & treads etc. over 20 mm (av.) thck base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary pigments including grinding and Granite polishing as per direction of Engineering -in -Charge in Ground Floor. {White cement and Pigment to be supplied by the Agency] In Ground Floor.

22.5

2700

60754

... More
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) b) Premium 100% Acrylic Emulsion .

639.65

84

53731

... More
Drainage and Cross Drainage Work Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1500 mm.

895.2

11927

106771

... More
Second Floor

4.97

76496

379956

... More
Boys Hostel (Sanitary and Plumbing Works) Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall up to 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessary specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and refilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials For 100 users i) With Pakur variety Stone Chips with using Steel:- SAIL/ TATA/ RINL

6

112141

672846

... More
Providing weep holes in Brick masonry / Plain / Reinforced concrete abutment, wing wall / return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V:20H towards drawing face. Complete as per drawing and Technical specifications.

346

115

39790

... More
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1500 mm.

46.76

11927

5577

... More
Second Floor

312.09

1792

559265

... More
S& delivery 240V. 50 Hz. 300 mm. Sweep 1420 r.p.m. Heavy Duty AC Exhaust Fan (Make- EPC)

121

3752

453992

... More
2nd Floor

913.38

6345

5795761

... More
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (B) Wall. With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of each tile above 0.09 Sq.m. (i) Coloured and decorative In Ground Floor

373.59

1088

406630

... More
In Second Floor

536.77

6031

3237520

... More
Making V-groove line ( 12 mm wide,12 mm deep) in plastered surface.

28

580

162

... More
At First Floor

122.6

1271

155838

... More
Extra over the corresponding item of earth work for removing semi liquid mud or slushy earth by iron pans, buckets etc

1119

2658

29743

... More
Supplying, fitting and fixing towel rail with two brackets. (a) CP over brass (iii) 25 mm dia rod and 750 mm long.

8

475

3800

... More
(b) In 1st Floor: ( A ) 20 mm THICK PLASTER (6:1) Internal wall

5545.95

155

863671

... More
(v) 40 mm dia

2

1590

3180

... More
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials.

4.2

1304

5477

... More
Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction.

2

1231

2462

... More
Supplying, fitting and fixing boiling water proof ply conforming to IS: 710-1977 bonded with phenol formaldehyde synthetic resin conforming to IS: 848-1974 of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in-Charge. [excluding the cost of supporting frame work and teak wood batten/Lipping] In Ground Floor (vi) 19mm

750

2420

1815000

... More
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] M 25 Grade (i) Pakur Variety

16.02

6155

98610

... More
Supply, Laying & Fixing of 50mm x 6mm galvanized (Hot Dip) steel strip in underground trench for interconnection between the Earth Points by proper welding and painting the lap & 'T' joints with 2 (two) coats of bituminous paint for making a Earth Grid. (NS)

800

296

236800

... More
Supplying dividing strip fitted and fixed with cement mortar (1:3) in mosaic or patent stone floor, dado etc. complete as per direction of the Engineer-in-charge. (i) Glass - 3mm. Thick. (a) 20 mm. wide strip.

3265.35

17

55511

... More
Supplying, fitting and fixing 15 mm Twin Flush Fitting (Model Code No. B1810112 of CERA or equivalent)

93

1041

96813

... More
(B) Filling in foundation or plinth by Fine sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)

124.77

59961

74813

... More
Supplying solid flush type doors of commercial quality, the timber frameconsisting of top and bottom rails and side styles of well seasoned timber 65mmwide each and the entire frame fitted with 37.5mm wide battens places both waysin order to make the door of solid core and internal lipping with Garjan orsimilar wood veneers using phenol formaldehyde as glue etc. complete, includingfitting, fixing shutters in position but excluding the cost of hinges and otherfittings in ground floor.:(a) 35 mm thick shutters (single leaf)

749.07

2659

1991777

... More
Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - InCharge. (Payment will be made on finished length of the work). (A) In 10-12 Micron thickness Annodizing film l) Rimless door. i) Top & bottom rail.

14.4

810

11664

... More
(b ) 110mm

54

33

1782

... More
Artificial stone in floor, dado, staircase etc. with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works, using cement @ 1.75 kg./sq.m. all complete including all materials and labour.In ground floor.Using grey cement.(iii) 35 mm. thick

150

321

48171

... More
In Third Floor

536.77

6142

3297101

... More
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run. (P-J1/Item-7)

120

175

21000

... More
Copal varnish of approved quality including preparing surface : (i) On new wood work : (b) Two coats

59.28

184

10908

... More
2nd Floor

7895.32

393

3102860

... More
SIGNAGES Supply and installation in position the "FIRE EXIT" Sign with luminicent colour having size 300 x 100 mm , gr floor to 3 rd floor stair

500

525

262500

... More
(b) Supplying 'Godrej' mortice lock chromium plated with keys 6 levers including fitting & fixing complete.

3

1954

5862

... More
Supplying& laying 20 mm designer chequered tiles of any shade and of approved quality as per IS: 1237: 1980 laid in patterns as directed in pavement, footpath including necessary underlay 25 mm thick average cement mortar (1:3) complete in all respect with all labour and materials [using cement slurry @ 4.4 kg/Sq.m at back side of tiles. Cement of mortar & slurry will be supplied by the Department. Border concrete if necessary to be paid separately].

71.55

804

57546

... More
M.S. works in brackets made from flats, angles, tees etc. to sizes specialy bent, twisted, forged; making holes drilled and fitted to rafter of trusses with necessary bolts, nuts, washer or screws etc.

0.37

9984

3704

... More
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.Using concrete mixture. M 25 Grade. Using Pakur Variety stone (a) In foundation and plinth

266.71

6155

1641676

... More
Third Floor

236.43

1617

382409

... More
Second Floor

191.07

128

24562

... More
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] M 25 Grade (i) Pakur Variety

87.02

6155

535643

... More
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. Ground Floor (e) Sal : Malayasian

0.39

76096

29677

... More
Supply & Fixing of perforated GI cable tray bend with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. 300 x 50 x 1.25 mm (18SWG).

20

625

12500

... More
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation.

166.47

7754

12908

... More
In Second Floor

1094.7

758

830812

... More
(b) Rendering the surface of walls and celling with white cement based wall putty of approved make and brand (1.5 mm)

59869.32

110

6585625

... More
(viii) 20 mm dia

15

604

9060

... More
(a) Priming one coat to steel or metal surface with synthetic enamel / oil bound primer of approved quality including smoothening surface by sand papering etc.

1360.65

29

39459

... More
First Floor

516.78

124

64365

... More
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. (a) In Ground Floor(Two coat): (b) Premium 100% Acrylic Emulsion

276.11

84

23193

... More
Supplying& laying 20 mm designer chequered tiles of any shade and of approved quality as per IS: 1237: 1980 laid in patterns as directed in pavement, footpath including necessary underlay 25 mm thick average cement mortar (1:3) complete in all respect with all labour and materials [using cement slurry @ 4.4 kg/Sq.m at back side of tiles. Cement of mortar & slurry will be supplied by the Department. Border concrete if necessary to be paid separately].

457.56

804

368002

... More
(a) Priming one coat to steel or metal surface with synthetic enamel / oil bound primer of approved quality including smoothening surface by sand papering etc.

49.28

29

1429

... More
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.

846

399

337554

... More
Neat cement punning about 1.5mm thick in wall, dado, window, sill, floor, drain etc.

150.26

32

4923

... More
Packing annular space between the outside of the housing pipe and the bore with puddled clay balls of approved size as per direction of the Engineer-in-charge with cost of all materials and labour complete.

4

417

1668

... More
Plastering (in wall , floor , ceiling etc. ) with sand and cement mortar including rounding off or chamfering corners as directed and racing out joints or roughening of concrete surface including throating and nosing & drip course where necessary. (B) With 1:4 cement mortar , (b) 15 mm thick plaster . (a) In Ground Floor:

1349.71

148

200081

... More
In Third Floor

1094.7

770

843948

... More
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. Ground Floor One Coat

3177.78

31

99782

... More
Supplying, fitting & fixing M.S. clamp for fixing door and window frames, end bifurcated including cutting brick work, fixing in cement Conc.with stone chips (4:2:1) fitted and fixed as per direction and mending all damages complete. (a) 40 mm X 6 mm. 250 mm length

120

29

3480

... More
Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brandconforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) ≤ 0.08 %] in floor, skirting etc. set in 20 mm thick sand cement mortar (1:4) bed prepared after application of slurry using 1.75Kg of cement per Sqm over the base and 2mm thick cement slurry using cement @2.91Kg./sqm at the back side of the tiles and laid over the mortar bed using 0.2 kg/sqm of White cement used for joint filling with approved pigment as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (Note: This work should not be executed without specific permission of Superintending Engineer) (b) ln Ground FIoor:(size not Iess than 800mmX 800 mm X 10.2 mm thick)

22.8

1465

33412

... More
In First Floor

31.29

5920

185247

... More
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface. Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes complete as per Clause 803 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).

115.92

584

67697

... More
Sub Total for Electrical Works=

-

-

-

... More
Brick work with 1-st class bricks in cement mortar (6:1) b) In superstructure, Ground floor

50.51

5095

257351

... More
Plastering (in wall , floor , ceiling etc. ) with sand and cement mortar including rounding off or chamfering corners as directed and racing out joints or roughening of concrete surface including throating and nosing & drip course where necessary. (a) In Ground Floor: 20mm th ( 1 : 6 ) Internal

5981.61

151

907590

... More
Fixing only bulk head ceiling fitting on wall /ceiling by screws etc.

4

58

232

... More
Cement concrete with graded stone ballast (40 mm size excluding shuttering) (A) In ground floor.(Pakur Varity) (a) 6 : 3 : 1 proportion.

59.68

5079

303141

... More
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.

846

68

57528

... More
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

258.99

344

89093

... More
Mastic Asphalt Providing and laying Mastic asphalt wearing course with paving grade bitumen meeting the requirements given in table 500-29 using approved coarse aggregate (pakur variety), fine aggregate, filler material and bitumen, prepared by using Mastic cooker including cost and carriage of all ingredients, cost of heating aggregates and binder, mixing in specified proportions conforming to approved Job Mix Formula and laid to required level and slope after cleaning the surface, compacting, sealing the construction joints and surface finishing conforming to specifications including providing antiskid surface with bitumen pre-coated fine-grained hard stone chipping of 13.2 mm nominal size at the rate of 0.005 cum per 10 sqm and at an approximate spacing of 10 cm center to center in both directions, pressed into surface when the temperature of surfaces not less than 100°C, protruding 1 mm to 4 mm over mastic surface, including the hire charges of all tools and plants and machinery, pay of operators, cost of fuel and lubricants and all other incidental charges and quality control all complete as per Clause 516 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). (i) 25 mm thickness (payment will be made on the basis of finished surface area)

3471.3

512

1779597

... More
Third Floor FCD

6

23198

139192

... More
Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868- 1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2- track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white

21.06

448

9435

... More
(vi) 32 mm dia

54

1160

62640

... More
S & F of 9Watt Led lamp. (Make- Philips/ Bajaj/ Crompton/ Havells)

639

95

60705

... More
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work up to 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) up to 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face up to the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well up to G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc. (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making necessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the excess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. (a) With 250 mm thick dry brick work and 250 mm thick cement brick work (6:1) and 1.00 m inside dia. SAIL/TATA/RINL

9

16184

145656

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] ii) With 1:4 Cement Morter b) 15mm Thick

3899.58

148

578074

... More
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.

249.72

11927

29784

... More
Supplying, fitting and fixing gunmetal wheel valve of approved brand bearing I.S.I. marking with fittings. (tested to 21 kg per sq.m.) (iv) 50 mm dia

2

2277

4554

... More
1st Floor

152.08

55996

8515791

... More
Excavation of soil for installation of Earth Electrode and filling & ramming as to GS (For morum soil).

180

295

53100

... More
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work up to 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) up to 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face up to the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well up to G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc. (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making necessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the excess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. (a) With 250 mm thick dry brick work and 250 mm thick cement brick work (6:1) and 1.00 m inside dia. SAIL/TATA/RINL

1

16184

16184

... More
d) shoe

2

111

222

... More
Extra for using approved H.B netting in every third layer in 16 & 17 of subhead A above in any floor

487.25

41

19977

... More
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1500 mm.

4905.56

11927

585087

... More
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (ii) Grill weighing above 16 Kg./sq.mtr and above Ground Floor

189.78

9696

1840078

... More
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.

852.03

11927

101622

... More
d) Add extra for excavation in morum soil

153.08

2082

3187

... More
(viii) 20 mm dia

1

604

604

... More
Next 50 metre

100

883

88300

... More
25 mm dia pipe (43 mm x 43 mm)

1200

79

94800

... More
Supplying and laying true to line and level vitrified tiles ofapproved brand (size not less than 600 mm X 600 mm X 10mm thick) in floor, skirting etc. set in 20 mm sand cementmortar (1:4) and 2 mm thick cement slurry back side of tilesusing cement @ 2.91Kg./sqM or using polymerised adhesive(6 mm thick layer applied directly over finished artificial stonefloor/Mosaic etc without any backing course) laid afterapplication slurry using 1.75 Kg of cement per sqM belowmortar only, joints grouted with admixture of white cementand colouring pigment to match with colour of tiles / epoxygrout materials of approved make as directed and removal ofwax coating of top surface of tiles with warm water andpolishing the tiles using soft and dry cloth upto mirror finishcomplete including the cost of materials, labour and all otherincidental charges complete true to the manufacturer'sspecification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be suppliedby the contrr]e)I (I) With application slurry @1.75 kg/ Sq.m, 20 mm sandcement mortar (1:4) & 2 mm thick cement slurry at back sideof tiles, 0.2 kg/ Sq.m white cement for joint filling withpigment. (B) Light Colour Ground Floor

2996.61

1259

3773062

... More
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: (x) 300mm long x 12mm dia. bolt.

696

151

105096

... More
M.S. works in brackets made from flats, angles, tees etc. to sizes specialy bent, twisted, forged; making holes drilled and fitted to rafter of trusses with necessary bolts, nuts, washer or screws etc.

0.74

9987

7390

... More
Labour charge for fabrication and installation of composite door,window, partitions made from annodized extruded alloy aluminium sections for the following units:- Fully glazed single leaf reamless swing door made of anodized aluminium alloy extrusions fabrication after cutting to proper shape and size, drilling and aligning fitted with heavy duty hydraulic action floor spring with top pin assembly and fitted with inbuilt locking arrangement and all other necessary fittings, fixture, adhesives and joineries, cutting the glass to requisite shape and size mounting the edges for fitting the same with dry set neoprine/EPDM gasket

12.96

1501

19453

... More
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. A) UPVC Pipes : ii) 110 mm Dia.

4.5

251

1130

... More
Hire & labour charges for shuttering with centering and necessary staging upto 4.00 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work in any concrete work.

913.97

357

326287

... More
Artificial stone in floor, dado, staircase etc. with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works, using cement @ 1.75 kg./sq.m. all complete including all materials and labour.In ground floor.Using grey cement.(iii) 35 mm. thick

373

321

119785

... More
Supplying, fitting and fixing pedestal of approved make for wash basin (white)

3

1497

4491

... More
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC.(a) One CoatIn ground floor.

3899.58

3140

122447

... More
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. Ground Floor One Coat

322.06

31

10113

... More
Supplying, fitting and fixing of roofing sheet of colour coated 0.45mm base Metal thickness 8MT ) ( 0.53mm Total P Thickness excluding paint ( TPT0 of 700mm effective cover width, 43mm deep rib spaced at 233mm c/c along with micro stiffners perpendicular to ribs for strength. The steel sheet shall have minimum yeald strength of 550MPa metalic coated of Zincalume, Aluminium Zinc alloy AZ150, conforms to IS15961, pre-painted with inorganic pigments super durable polyester (SDP) colorbond rxw ( xterior roofing and walling ) withhigher SRI (solar reflective index )value thermatech technology conforms to IS 15965 class 3. The sheets shall be fixed to every purlin by means of clips - KL70. The clip KL-70 shall be fastened with nominal 40µm zinc coated or nominal 25µm zinc-tin alloy coated. Hex head, self-drilling screw as per AS 3566-2002 Class 3 fasteners. The profile sheet shall be of same parcent of coil. The profile sheet, fasrners size etc. shall be approved by the concern authority. The measurement shall be based on finished / covered surface area. ( Note. Specific permission of the Chief Engineer is required for execution of this item )

435

1043

453705

... More
1st Floor

2095.44

84

177505

... More
(v) Plain Y (a) 75 mm

24

102

2448

... More
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement.(ii) 25 mm. thick.

77.71

261

20357

... More
Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm

87

613

53331

... More
(iv) Door Tee(LH) & (RH) (a) 75 mm

24

178

4272

... More
Second Floor

897.12

1098

985432

... More
4 core 35 sqmm

54

330

17820

... More
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. A) UPVC Pipes : ii) 110 mm Dia.

38.4

251

9638

... More
Supplying, fitting and fixing urinal flush pipe fittings of approved brand. (a) CP urinal flush pipe fittings range of one.

4

414

1656

... More
Laying of Cables Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed

650

177

115050

... More
First Floor

7895.31

124

983361

... More
2nd Floor

210.17

393

82597

... More
a) 415 Volts, 200A, TPN SFU with proper HRC fuse (open execution type) (Make: L&T/Legrand/Schenider/ABB/Siemens)-1No. Bus bar section : 415 V, 315Amp capacity Aluminium 4 bar copper bus bar mounted on non-hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification- 1 set. The busbar is to be rigidly supported on suitable non-hygroscopic insulating materials of robust ration to with stand electromechanical stress in the event of earth fault. All connection to bus to made by suitable nuts & bolts. The busbar is too wrapped with coloured PVC (Red. Yellow, Blue & Black) for colour identifications. Outgoing Arrangement : a) 415V, 100 Amps TPN SFU units with HRC fuses (Make:- L&T/SIEMENS/ABB/ SCHNEIDER) in open execution.--- 3 No. b) 415V, 63 Amps TPN SFU units with HRC fuses (Make:- L&T/SIEMENS/ABB/ SCHNEIDER) in open execution.--- 2 No. (e) E.I. Danger Board of suitable size ------- 1 no. Metering Panel:- a)Digital multifunction meter with selector push button switch (up/down) with Voltage, Current, Frequency, Total Harmonic Distortion, PF, KW, KVA, Kwh, KVAh and Preloaded Max & Min Demand with Date & Time Stamping display (Make-Schneider Electric/ Cat No- EM6400NG Class accuracy CIo.5S, POP of Accuracy Class 0.5S or equivalent model of Legrand/ Siemens/ L&T) - 1 No.

-

-

-

... More
Pre-Constructional Anti-termite measures: (c) Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable ncentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS-6313 (part -II) 1981. ( Mode of measurment will be per Sq.m of plan area of plinth treated.)

24.5

81

1985

... More
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987; iv) 5mm thick coloured / tinted / smoke glass.

4.23

585

2475

... More
Second Floor

7895.31

128

1014942

... More
With 1:4 Cement Morter b) 15mm Thick Ground Floor

639.65

148

94822

... More
Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc.(a) With 'P' trap.CERA / HINDWARE

87

1421

123627

... More
ii) With 1:4 Cement Morter c) 10mm Thick Ground Floor

18

120

2170

... More
Fourth Floor

2673.57

136

365076

... More
1st Floor

516.77

375

193789

... More
(b) STEEL SURFACE

1360.65

79

107491

... More
(b) Depth of excavation for aditional depth beyond 1500 mm and upto 3000 mm.but not required shoring

298.66

19238

57457

... More
B) UPVC Fittings : a) Plain Tee iii) 160mm Dia.

2

507

1014

... More
iii) 160mm Dia.

5

305

1525

... More
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) ii) Luxury Quality

59869.32

70

4190852

... More
Supplying and laying 3 core 2.5 sqmm flat Cable ( Finolex/ PWD approved) for submersible pump-motor set

200

111

22200

... More
(d) (i) Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand).

276

815

224940

... More
(b) For Concealed Work 15 mm

42

137

5754

... More
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (d) 2000 litre capacity

30

10434

313020

... More
125 mm thick Autoclave aerated concrete block Work with size 625 mm x 250 mm x 125 mm- Grade-I,having drying Shrinkage less than 0.05% conforming to IS: 2185 ( Part-3)-1984 made up of fly ash (conforming to IS: 3812-1981, with permissible loss on ignition upto 6%), lime , cement and complete in all respect as per direction & satisfaction of Engineer -in Charge . In Ground Floor

206.66

734

151883

... More
With 1:4 cement mortar. 15mm thick. Outside Plaster. Ground Floor

3177.78

148

471074

... More
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats

197.44

70

13821

... More
Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. In ground floor. (In case of non-supply of single plank, penal rate of reduction of 20% will be made) (i) 50mm thick shutters with 25mm thick panel of size 30 to 45 cm (a) 1st class best Indian teak.

4.62

6288

29051

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. SAIL/TATA/RINL Tor Steel Roads/HYSD/Fe415/Fe500/Fe500D Ground Floor

17.61

55566

978589

... More
Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) By Fine Sand

335.7

59961

201289

... More
250 mm th. Autoclave aerated concrete block Work with size 625 mm x 250 mm x 125 mm- Grade-I, having drying Shrinkage less than 0.05% conforming to IS: 2185 (Part-3)-1984 made up of fly ash (conforming to IS: 3812-1981, with permissible loss on ignition upto 6% ), lime , cement and laid in Cement Mortar (1:6) complete in all respect as per direction & satisfaction of Engineer -in Charge .

732.74

5809

4256881

... More
(c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work Foundation

10438.8

357

3726652

... More
Second Floor

10.7

1792

19174

... More
Supply & Fixing of 7 W decorative single head wall light colour chrome Make- Philips ASTER 581923 with 3 years of warrenty from OEM or eqv. Make & model of Crompton /Bajaj / Wipro)

16

1889

30224

... More
Third Floor

1804.56

160

289163

... More
(i) 32 mm thick

1.57

2763

4338

... More
Part-A: CIVIL WORKS

-

-

-

... More
20 mm

2940

158

464520

... More
Geophysical investigation of the acquifer by electrologging system with all tools and plants as necessary including supply of necessary report.

2

8247

16494

... More
125mm thick brick work with 1st class bricks in cement morter (1:4) Ground Floor

25.2

697

17577

... More
a) (i) CP Pillar Cock - 15 mm. (Equivalent to Code No. 507 & Model Tropical / Sumthing Special of ESSCO or similar brand).

87

555

48285

... More
A(X) Bend 87.5 Degree (a) 75 mm

2

61

122

... More
(b) Rendering the surface of walls and celling with white cement based wall putty of approved make and brand (1.5 mm)

2412.85

110

265414

... More
150 mm

100

1420

142000

... More
Supplying, fitting and fixing porcelain soap tray of approved make. (i) Recessed soap tray of size 150 mm X 50 mm

2

338

676

... More
Neat cement punning about 1.5mm thick in wall,dado, window sill,floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.

36.78

32

1205

... More
Plastering (in wall , floor , ceiling etc. ) with sand and cement mortar including rounding off or chamfering corners as directed and racing out joints or roughening of concrete surface including throating and nosing & drip course where necessary. (a) In Ground Floor: 20mm th ( 1 : 6 ) Internal

480.14

151

72852

... More
Extra rate for adding Polyester Fibre anti shrinkage material @ 0.25% by weight of cement [or as per Manufacturer's Specification] as secondary reinforcement to arrest hair crack in concrete including cost of Fibre

1.83

414

758

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. SAIL/TATA/RINL Tor Steel Roads/HYSD/Fe415/Fe500/Fe500D Ground Floor

7.05

55566

391743

... More
Laying of cable as below, on existing Cable Tray or existing angle iron frame and binding with suitable size GI wire . Up to 50 sqmm

350

11

3850

... More
Supplying, fitting and fixing stainless sink complete with waste fittings and two coats of painting of C.I. brackets. (b) Sink with drain board 1050 mm X 450 mm X 180 mm

12

5006

60072

... More
1st Floor

2095.44

122

257152

... More
Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete. 635 mm X 395 mm X 420 mm

84

2869

240996

... More
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement.(ii) 25 mm. thick.

1103.97

261

289196

... More
First Floor

913.38

6250

5708990

... More
Supplying bubble free float glass of approved make and brand conforming to IS : 2835 - 1987. iv) 5mm thick coloured / tinted / smoke glass.

3.24

585

1895

... More
Labour for Chipping of concrete surface before taking up Plastering work. In ground floor.

607.19

21

12751

... More
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three ) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-incharge. Weight of Strainless Steel railing per metre 6.5 Kg (approx)

360.6

9077

3273166

... More
Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (A) For Exposed Work (ii) 50 mm dia. medium quality

30

540

16200



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.