Public Works Department Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Public Works Department - PWD Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date13 Nov 2024
Closing Soon25 Nov 2024
Tender AmountRefer Documents
Costs
EMD
₹ 19,500Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WBPWD_769209_1Tender No
WBPWD/EE/AED /eNIQ-79/2024-25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://wbpwd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
A) 6 sq mm
4
-
-
b) 4 sq mm
18
-
-
c) 2.5 sqmm
8
-
-
Supplying and fixing 415V,16-32A per way , double door Horizontal TPN MCB Distribution board (Enclosure (607716)with IP-42/43 protection,with 63A, 4 pole isolator as incomer and SPMCB's ('C' curve,10kA) as outgoing concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Legrand/ABB/Siemens) a) 4 way,,63A FP isolator,12nos. SPMCBs as outgoing.
1
-
-
Supplying and fixing double-door SPN MCB Distribution Board(Enclosure-607711) with IP-42/43 protection, with DP isolators as incomer and SPMCB('C' Curve,10A) as outgoing,fixing at flat iron frame on wall &mending good the damages to original finish; inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.(Make: Legrand/ABB) i) (2+8)Way,with S&F 240V 40Amps DPMCB isolator as incomer and 240V 6-32A SPMCB of Breaking capacity 10KA & C characteristics 8 nos as outgoing,
2+8 Way (Legrand/ABB/Siemens)
2
-
-
Supplying and fixing MCB SS enclosure with IP-20/30
protection, powder coated provision for two/four pole
MCB, concealed in wall after cutting the wall & mending
good the damages to original finish incl. supply of 16 A DP MCB ,painting, connection & provision for earthing attachment .
1
-
-
Supply & delivery of XLPE/A Al cable of following size with 2 nos 10 SWG GI wire as ECC.(Make- Havells/Polycab/KEI/Gloster) as per choice of EIC. 4Core 35 Sqmm. (From panel to TPNDB)
35
-
-
Supplying and fixing 415V, 100ATPN SFU with sheet
steel enclosure on flat iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC
fuse as per rating.
1
-
-
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :4 core 35 sqmm
2
-
-
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket(Dowels make), tapes, anticorrosive paste & jointing materials.
4 core 35 sqmm.
2
-
-
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support.With out angle iron support. 150x50x1.25mm (18SWG).
40
-
-
Supply & Fixing of perforated GI cable tray bend with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support.150x50x1.25mm (18SWG).
2
-
-
S/Delivery following 250 Volt, 18/20 Watt, 4 Ft. long single/double LED Tube fittings complete with LED polycarbonate tube lamp having at least 100 lumen/watt and cast iron box type fittings.(Make- Crompton/Philips Master LED)a. Single LED Tube(18/20 Watt)
14
-
-
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “U” type MS clamp whose both side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
14
-
-
S/F BC LED lamp (B22) as per direction of E.I.C. (Make- Philips/Crompton/Syska)(9watt)
5
-
-
Supplying and delivery of 250 volts, 50Hz, (12”) sweep 1420 R.P.M. heavy duty exhaust fan complete with all accessories (Make-EPC/usha.CG) as per direction of EIC. Exhaust fan(12”)
8
-
-
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:30 cm (12")
8
-
-
Supply & Fixing 30 cm Exhaust fan (12") louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long)
8
-
-
Supply of 48"ceiling fans complete with all accessories like fan blade,canopy,capacitor etc Model / Cat No. ( Make - USHA /Crompton Greaves/Havells ) as per direction of EIC a.1200 mmSweep .
7
-
-
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
7
-
-
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWDSpecification Book – May 1991)
7
-
-
Supplying & fixing of 415V, Timer DB Fixed on Wall by flat iron/Angle frame or as per direction of EIC .
The Box should comprising following accessories.........
A).Double-door SPN-MCB Distribution Board with IP-42/43 protection 2+12 way make Legrand/L&T or as to GS.
B). 1No. 250V ,50Hz,16 Amp Digital daily & weekly time switches(Make L&T-67DDT0/Eqv. legrand)
C)1No 415V,40A FP-Contractor(Make-L&T/Eqv. legrand). D)1No. 415V,40A FP-MCB(Make-L&T/Eqv. legrand). E)1 No. Toggle Switch(Pass & Seymour) should be fixed inside the box.
F)1Nos LED Indication Lamp for running condition. G)The complete arrangement must be wiring by suitable size of PVC insulated Cu wire with suitable socket/lugs as per requirement & direction by EIC.
2
-
-
Supply & Delivery of 3-Star rated Non-Inverter Hybrid Hi-Wall split type room air conditioner with following accessories & features : i). Tonnage : 2.2 Ton.
ii). Refrigerant Type : R410/R32A.
iii). Compressor type : Super Tropical return cooled Rotary type.
iv). Evaporator & Condenser Meterial : Copper.
v). Power Supply : 230V,50Hz,1Φ.
vi). Running Current at F.L : 9.2Amp.
vii). Standard cooling at 100% capacity : 7500W (Max) viii). Power Consumption at 100% capacity : 2050W (Max)
ix). Rated ISEER (Kwh/Kwh) : 3.72 or higher.
x). Inndoor Fan Speed Control level : 4/5 Speed Control.
xi). Indoor Air-Flow Volume High : 1450CMH.
xii). Indoor Airflow Distace : 15-18m.
xiii). Indoor Noise level : 40db.
xiv). Remote : Wireless Advanced Remote operation.
(Make: Mitsubishi Heavy SRK25CSS-S6A/O-General/Hitachi).
4
-
-
Supply & Delivery of 3-Star rated Non-Inverter Hybrid Hi-Wall split type room air conditioner with following accessories & features : i). Tonnage : 1.5/1.6 Ton.
ii). Refrigerant Type : R410/R32A.
iii). Compressor type : Super Tropical return cooled Rotary type.
iv). Evaporator & Condenser Meterial : Copper.
v). Power Supply : 230V,50Hz,1Φ.
vi). Running Current at F.L : 6.6Amp.
vii). Standard cooling at 100% capacity : 5900W (Max) viii). Power Consumption at 100% capacity : 1485W (Max)
ix). Rated ISEER (Kwh/Kwh) : 3.99 or higher.
x). Inndoor Fan Speed Control level : 4/5 Speed Control.
xi). Indoor Air-Flow Volume High : 1350CMH.
xii). Indoor Airflow Distace : 15-17m.
xiii). Indoor Noise level : 40db.
xiv). Remote : Wireless Advanced Remote operation.
(Make: Mitsubishi Heavy SRK20CSS-S6A/O-General/Hitachi).
2
-
-
Lifting,Shifting,Installation,Testing & Commissioning of IDU & ODU of Split Air Conditioners machines,after making hole in wall on mending good the damages to the original finish as required & necy. scaffolding arrangement, labour cost etc.on both side(IDU & ODU Installation),Supply of required Refrigerant R32/R-410A & Supply & Fixing of Heavy Duty ODU stand by drilling holes in wall,fastners ,bolts washers as per direction of EIC.
6
-
-
Supply & Fixing of Copper Refrigeration pipe line for liquid and suction line with fittings, elbows, bends, supports & brackets etc. with 9mm nitrile rubber tube with proper insulation tape required.
(Make- Ryoku/Totaline/Jobu/ Nippon/EIC Approved).
i) Suction Line (5/8" OD with 0.7mm thick)
24
-
-
ii). Liquid Line (1/4" OD with 0.6 mm thick)
24
-
-
Supply and laying Control copper Cable (PVC insulated & unshethed,un-armoured) from Condensing Unit to IDU control panel & Vice Versa if Required as per OEM (Make: Havells/RR Kable /finolex/EIC Approved )
i). 4 core 2.5 sq mm cable.[IDU to ODU]
24
-
-
Supply and laying of 25mm Drain Water piping work out of PVC/HDPE hard pipes of following sizes incl. fiting accessories bends, elbows, tees flanges, tapings, wall sleeves hangers, supports, anchors etc. as required.
(Make : Supreme / Astral/ EIC approved).
12
-
-
Supply & Fixing 240 V, 20 A Plug socket (Brand approved by EIC) on sheet metal switch board incl. S & F 100x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.(For AC)
6
-
-
Supply and delivery of 20A Plug Top for interconnection of Indoor AC machine Brand as per choice of EIC.
6
-
-
S/F of 22 A OLP 3 plus starter(Electron make on suitable size MS box with 3mm top cover incl. fixing of MS box & mending good the damages to original finish.
6
-
-
Supply and fixing of 12 V battery charger 125 KVA DG near pathology.
1
-
-
Add GST @18% On total from item no 1 to 32.
1
-
-
Add LWC @1% On total from item no 1 to 33.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%