Public Works Department Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Public Works Department - PWD Tender
Healthcare and Medicine
Eprocure
Opening Date2 Dec 2024
Closing Soon31 Dec 2024
Tender AmountRefer Documents
Costs
EMD
₹ 50,512Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Wbpwd/ee/n24/el/eniq- 205/24-25/ Retender
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WBPWD_763770_2Tender No
WBPWD/EE/N24/EL/e-NIQ205/24-25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://wbpwd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
RPM : 1500
-
-
-
... More
Power : 310 BHP or Higher
-
-
-
... More
Duty : PRIME
-
-
-
... More
Cooling : Liquid cooled (EG Compleat 50:50)
-
-
-
... More
Cylinder : 6 or high
-
-
-
... More
Aspiration : Turbo twin water to air Charged
-
-
-
... More
Type of Governor : Electronic
-
-
-
... More
Fuel Tank Capacity : Minimum capacity 440 Ltrs.
-
-
-
... More
Fuel Consumption at 75% rated Load with Radiator or Fan :42.6 Ltr./ Hr. or Less
-
-
-
... More
Fuel Consumption at 100% rated Load with Radiator or Fan : 56.9 Ltr./ Hr. or Less
-
-
-
... More
Overload Capacity : 10% overload for one hour for every 12 hours continuous running at full load or better
-
-
-
... More
Engine instrument Panel : Consisting of starting switch with Key, Lube Oil Indicator, water temperature Indicator, RPM indicator and hour meter.
-
-
-
... More
Safety Controls : Emergency Stop, Low Lube Oil Pressure warning/ Shutdown, High Engine Water Temp. warning/ Shutdown, Sensor failure Indicator, Engine over speed indicator, Battery charging and low battery indicator
-
-
-
... More
Exhaust Silencer : Residential Type
-
-
-
... More
Starting system : 12V./ 24 V. starting system complete with starter motor, charging alternator with rectifier and Cutout as per manufacturer standard.
-
-
-
... More
Battery : Lead Acid, Low Maintenance or SMF and conforming to relevant IS Specification with Low/High Battery Voltage and Weak Battery warning
-
-
-
... More
Alternator
Make : KOEL GREEN /Stamford/ Leroy Somer/ Crompton Greaves/ABB/ Alsthom
-
-
-
... More
Rating : 415 V., 3Ph. 50 Hz., 250 KVA, 1500 rpm
-
-
-
... More
Type : Brushless, self excited and self regulated
-
-
-
... More
Insulation : Class H
-
-
-
... More
Protection : screen-protected drip proof with Min.IP-23 degree of protection
-
-
-
... More
RPM : 1500
-
-
-
... More
Voltage Regulation (max) : ±1% on balance load.
-
-
-
... More
Winding connection : Star with Neutral
-
-
-
... More
Total Distortion factor : as per relevant of ISO: 8528.
-
-
-
... More
Total Harmonic distortion in output waveform : No load 1.5 %, Non
distorting balanced linear load 5 %
-
-
-
... More
AMF Panel
Cubical type floor mounted AMF panel made from 14 SWG Sheet Steel, duly pretreated, powder coated painted and aesthetically finished, suitable for controlling of 250 KVA DG set having following specification/features.
-
-
-
... More
i)2 No. 400 A AC3 duty, 4pole power contactor and U/V release etc. [make: Legrand/ SIEMENS/Schneider/ABB]
-
-
-
... More
ii) 2 Nos. 400 A, 3pole, 50 KA MCCB with microprosser based LSIG protection. [make: Legrand/ SIEMENS/Schneider/ABB]
-
-
-
... More
iii) In Built By-Pass switch for rated capacity
-
-
-
... More
iv) On -delay timer for load change over
-
-
-
... More
v) On-delay timer for engine shut off
-
-
-
... More
vi) Engine On-Off switch (Push button type)
-
-
-
... More
vii) Battery charger complete with voltage regulator, booster selector switch, on-off switch, voltmeter and ammeter for charging the battery from mains. This will be in addition to the battery charging alternator fitted on the engine
-
-
-
... More
viii) Minimum five number indicating lamps to indicate 'mains ON', 'load on mains', Set running', 'load on set' and 'battery charger on'.
-
-
-
... More
ix) Audio visual alarm for 'Low lubricating oil pressure', 'High water temperature, Start failure', and DG over load'.
-
-
-
... More
ix) Mode selector for setting the panel on Auto/ Man/ Test Mode
-
-
-
... More
x) Microprocessor based relay with composite meter for digital display of following.
-
-
-
... More
Generator voltage/AC Mains voltage.
-
-
-
... More
Generator Current in all phases
-
-
-
... More
Frequency
-
-
-
... More
Power Factor
-
-
-
... More
Energy
-
-
-
... More
Indication for alternator supply
-
-
-
... More
Running time indications number of hours of operation and service intervals, service due indications
-
-
-
... More
The AMF panel must be designed to ensure trouble free performance and ensure switching over Electrical Load to DG within 15 (fifteen) second from the instant of mains failure.
-
-
-
... More
Acoustic Enclosure
-
-
-
... More
The DG set should have integrated acoustic enclosure at the manufacturing state itself. High quality acoustic enclosure must be certified as per CPCB-IV norms.
-
-
-
... More
Base Frame
-
-
-
... More
Common iron channel fabricated base frame containing the engine and alternator, mounted on AVM pads and having provision for lifting Hook.
-
-
-
... More
Terms & Conditions
-
-
-
... More
(i) Rate should be quoted inclusive of all applicable taxes and Duty etc.
-
-
-
... More
(ii) All materials, equipments & accessories must conform to relevant IS specifications. The DG Set to be supplied must be from the authorized OEM of the respective Engine Manufacturer.
-
-
-
... More
(iii) Necessary manufacturer's test certificate for Diesel Engine, Alternator etc. Will have to submit in triplicate copy during delivery of the equipment.
-
-
-
... More
(iv) Copy of "Type Approval Certificate" and Certificate of "COP" must be produced at the time of delivery issued from competent Authority (As per CPCB-II).
-
-
-
... More
(v) Circuit Diagram for AMF Panel must be submitted from the Manufacturer/OEM.
-
-
-
... More
(vi) The entire set must be warranted at least 15 months from the date of Delivery/12 months/ 5000 Hrs from the date of Commissioning whichever is earlier. However Engine & Alternator should be warranted of 2 years/5000 Hrs, whichever is earlier.
-
-
-
... More
INSTALLATION OF DG SET
Providing cement concrete foundation for the DG set with 1:2:4 (1 cement : 2 course sand : 4 graded stone aggregate 20 mm nominal size)[M20 grade ] including excavation, providing base concrete with 1:5:10 cement concrete, required centering/ shuttering, finishing the exposed portion etc. as reqd. ( Item will be paid based on measurements for 1:2:4 CC, but excluding the 1 : 5: 10 leveling course of base concrete) . Dimention of the foundation (L x W x H - 5300 x 2300 x 1200 ) mm as per direction of E-in-Charge and manufacturer recommendation.
1
-
-
... More
Supply & fixing of exhaust gas piping of 150 mm dia MS black class B pipe welded incl. all necessary bend supports and clamps anti vibration mounting insulation of exhaust system with 50 mm thick mineral wool covered with wire mesh and aluminium cladding ( from DG sets to top of the building plus 3mtr or as per CPCB) for 250KVA/320 KVA DG set as per direction of EIC.
20
-
-
... More
S&F special type MS angle ironstructure support made of 40x40x6 mm. MS angle with flat iron by proper welding etc clamp with nuts, bolts & washers etc. for 150 mm. dia (Vertical Run)
1
-
-
... More
S&F rain protection canopy for 150 mm exhaust pipe
1
-
-
... More
S& delivery of 200 ltrs. Capacity heavy gauge MS sheet barrel with MS angle made support stand.
2
-
-
... More
Supply & delivery of best quality oil hand pump with 1" dia PVC flexible pipe (12' ft. approx.)
1
-
-
... More
S &D of HSD for testing & immediate run of DG set incl. carrying charge
230
-
-
... More
S & D of Mobile Oil for testing & immediate run of DG set incl. carrying charge
100
-
-
... More
S& laying 120 sq. mm. single core multistrand PVC insulated flexible Cu wire in suitable size of PVC flexible pipe (reinforced) from nutral earth busbar to transformer point as required (for Transformer /Generator neutral earthing) including Socketing both sides by Cu Socket.
10
-
-
... More
Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 65 mm x 8 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 80 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts (Page-G-1/2(e))
4
-
-
... More
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe (Page-G-2)
4
-
-
... More
Extra treatment of soil by using salt & charcoal for plate electrode as to G.S. (Page-G-2)
4
-
-
... More
Connecting the equipments body to earth busbar incl. S & F 65 mm x 8 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc. ( page-G-2)
20
-
-
... More
Supply & Delivery of 1.1 KV grade XLPE/PVC insulated. PVC sheathed, steel Armoured Al. conductor Cable .(Gloster/ Polycab/RR / As per EIC)
4 core 185 sqmm NS
60
-
-
... More
Laying of one No. cable above 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
40
-
-
... More
Cutting concrete road of 300 mm thickness for drawing the cable of size 185 sqmm in under ground trench and mending good the damages as to original by cement concrete mortar as per instruction of E I C . [F-3/5iii]
20
-
-
... More
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :[F-4/7c]
4 core 185 sqmm
4
-
-
... More
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :[F-5/8b]
4 core 185 sqmm
4
-
-
... More
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating(L&T/ABB/Siemens/ as per Eic) [D-3/4a]
-
-
-
... More
415 V 415 A
1
-
-
... More
415 V 320 A
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%