Public Works Department Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Public Works Department - PWD Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date10 Jan 2024
Closing Date22 Jan 2024
Tender AmountRefer Documents
Costs
EMD
₹ 17,400Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WBPWD_638854_1Bid Award Id
ViewTender No
WBPWD/EE/JED/NIQ 24e/Q of 2023-24.Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://wbpwd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Laying of cable on wall/surface incl. S & F MS saddles with earthing attachment in 2X10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting .
-
-
-
Laying of cable upto 3/4 core 25 sqmm
98
-
-
S & F compression type brass cable gland complete with brass gland, brass ring & rubber ring for dust & moisture proof entry of XLPE/PVC armoured cable.
-
-
-
4 core 10 sq. mm.
4
-
-
4 core 25 sq. mm.
2
-
-
Finishing the end of the XLPE/PVC armoured cableas by crimping method incl. S&F solderless socket (Dowels make), tapes, anticorrosive paste & joiting materials.
-
-
-
4 core 10 sq. mm.
4
-
-
4 core 25 sq. mm.
2
-
-
Supply and fixing of Timer DB for with following accessories incudind making necy connection including supply & fixing and febrication of GI metal box for incorporation of the following
a) S/F- 32 FPMCB as to GS
b) S/F- Digital Time Switch cat no L&T AUTSO2ASTOO (2 Module) - 1NO
c) S/F -32A contactor with 2 NO 1 Module) Make L&T Cat No - AUMC2OO2501 - 1No
d) Toggle Switch - 1 N. (e)-6 way SPN DB enclosure as to GS.
Make - L&T or equivalant SIEMENS, ABB Elegance, Legrand
3
-
-
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 25mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required
-
-
-
4 x 84/0.3 (6 sqmm) + 2 x 56/0.3 (4 sqmm) ECC
18
-
-
Dismental of existing 12 TR./9 TR. Ductable AC machine (both Indoor & Out door) and Re install the machine at another place with S&F of all materials.
8
-
-
Supply & Delivery of Hi-wall Split Air Conditioner having following specification.
Cooling Capacity (KCal / Hr) - 9070KCal / Hr (3.0 TR)
ISEER Rating - 3 Star / 2018-2019 as per BEE/BIS
IS compliance - IS 1391
Refrigerant - R410A/R32
Compressor - Rotary / Scroll
Evaporator & Condensor Coil : Copper
Operating Outdoor Temparature = 50ºC and above
Power Supply - 415V,50Hz (+Tolerrance as per applicable standard)
PCB should be enclosed in metal enclosure
[Make: Mitsubishi Electric / O-General / BLUESTAR]
3
-
-
Installation, Testing & Commissioning of Indoor & Outdoor unit of above Hi wall split AC machine after making hole in wall etc as per direction of EIC including S&F of necessary fixing arrangement for indoor and outdoor unit, duly painted, laying and making connection of refrigeration pipe, power cable, drain pipe etc as per direction of the EIC.
3
-
-
S&F of following items for complete installation and commissioning of aboove AC machines including Supply & Fixing of refrigerant pipe with insulation nitrile rubber insulation tube of minimum thickness 9mm (Make: Accoflex/Armaflex) (as requisite dia) including wrapping insulation and copper wire with GKB Gold wrapping tape & 3 core PVC insulated FRLSZH grade copper cable (Make : Finolex / Havells / Polycab)
12
-
-
Supply & fixing of PVC drain pipe as of required size for split type and mega type split ac machine.(make approved by EIC).
15
-
-
Copper refrigeration pipe line for liquid and suction line with hard drawn copper piping with supports & brackets
-
-
-
Cu. Pipes Suction line 28.5 mm ( 5/8") dia and 15.88 mm (1 / 1/8 ") dia with nitrile rubber insulation.
20
-
-
Supply and fixing of necessary electrical arrangements of Air Conditioning Units, PVC insulated FRLS grade Copper cable for connection betweeen indoor and outdoor units, 1.1 KV grade.
-
-
-
3 core x 2.5 mm² (Make- Polycab/ Haavells/Gloster/KEI/RR).
20
-
-
SITC of Fabricated G.I Sheet Metal Square Air Duct complete with Class ' O' 9 mm thick Nitrile Rubber, Angle, Fastner, supports, dampers etc. as per specifications & site requirement.
-
-
-
For 24 SWG
100
-
-
For 22 SWG
28
-
-
Supplying, fabrication & fixing 03 Nos. M.S. Angle/M.S C chanel of size (75 mm x 75 mmx6mm) for placing the outdoor unit of ductable split AC incl. drilling 05 nos holes in each Angle including cutting holes into the wall & grouting the same (1:1 ½ :3) etc for rest of Outdoor units of 9.0TR, 12 TR. Air Conditioning Machine.
150
-
-
Supply & Fixing of IDU & Duct Covered with 3mm thick ACP Board (Make: Aludecor /Protap Bond) Complete with linkages, levers, fittings, supports, all accessories also Tap door making arrangements and any other item required to make the system complete as per direction of E.I.C. (AL 33R)
105
-
-