Public Works Department Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Public Works Department - PWD Tender
Security and Emergency Services
Eprocure
Opening Date8 Jan 2025
Closing Soon21 Jan 2025
Tender Amount₹ 6,00,000
Costs
EMD
₹ 12,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_WBPWD_797227_1Tender No
WBPWD/EE/KNHED/e-NIQ-143/24-25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://wbpwd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply, Installation,Testing & Commisioning of Micropresssor controlled IP Addressable multisensor detector IP 54 ( VDS / UL approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. (Approved Make : ( (Bosch/Siemens-/ Johnson Controls / Edward /Securiton/Honeywell)
30
-
-
... More
Supply, Installation,Testing & Commisioning of IP Addressable Manual Call Point ( VDS / UL approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required. (( (Bosch/Siemens/ Johnson Controls / Edward /Securiton/Honeywell)
4
-
-
... More
Supply, Installation, Testing & Commissioning of IP Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. Degree of protection IP65 ( VDS / UL approved) approved. (Approved Make: (Bosch/Siemens/ Johnson Controls / Edward /Securiton/Honeywell )
4
-
-
... More
Supply, Installation,Testing & Commisioning of Micropresssor controlled IP Addressable Heat detector IP 54 ( VDS / ULapproved ) with combination of fixed type & Rate of Rise of Temperature feature. Detector shall have maimum triggering temperature programmable from 60 deg. C to 80 deg. C., having high level of immunity to electromagnetic influances and show alarm signal limit temperature is reached. Detector shall have inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. (Approved Make : (Bosch/Siemens-/ Johnson Controls / Edward /Securiton/Honeywell )
4
-
-
... More
Supplying, installation, testing and commissioning of LED type Response Indicator ( VDS / UL approved) having 2 Nos. red coloured LED lamps including connections etc. (Approved Make : ( (Bosch/Siemens/ Johnson Controls / Edward /Securiton/Honeywell )
10
-
-
... More
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/RR Kable/Polycab ) through 19 mm dia PVC 'FR' type Rigid Conduit pipe with necessary arrangement as per G.S. (Make : Precision/ AKG/ Universal/ Polycab) on the surface of the wall.
400
-
-
... More
Checking & Testing of necessary cable and conduiting work for installed at CCU 3rd Floor G bldg. campus of ID & BG Hospital, Kolkata, as per latest Fire alarm guide line (IS2189/NBC/NFPA72).
1
-
-
... More
Dismantling existing FDA sytem Panel, Detector, MCP & Hooter and shifting to sectional store.
1
-
-
... More
Supply, Installation,Testing & Commisioning of Micropresssor controlled IP Addressable multisensor detector Complete with Mounting Base IP 54 ( VDS / UL approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. Make :Siemens/ Approved by EIC ( for the existing system)
40
-
-
... More
NOTE :- 1) The Fire Alarm system shall comply with latest requirements of --
(i) National Fire Protection Association (NFPA) Standards, (ii) IS 2189 ,
(iii) NFPA 70 National Electric Code, (iv) NFPA 72 National Fire Alarm & Signaling Code , (v) Local Statutory Regulations , (vi) Manufacturer Recommendation. vii) System should be integrated with the components like FACP, Detectors, MCP, Hooter, Monitor Module, Relay Module, etc. and all these components should be of same brand.
-
-
-
... More
(Rate should be quotated all taxes and duties, GST)
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%