Public Works Department Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date5 Sep 2024
Closing Date30 Sep 2024
Tender Amount₹ 97,02,919 
Notes
Download

Costs

Summary

Medical College And Hospital, Kolkata Necessary Civil Work For Setting Up Of Skill Lab At 1st And 2nd Floor Of Academy Building

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Applying epoxy based reactive joining agent for joining the old concrete with fresh concrete to be applied within manufacturer's specified time as per manufacturers specification. (0.4 Kg / m² of concrete surface).

53

19518

368.27

... More
Cleaning the exposed reinforcement preferably upto full diameter by wire brush, applying two coats of polymer based rust removing compound left for 24 hours, removing the coating and then applying two (2) coats of polymer modified anti corrosive protective coating formulated to inhibit the corrosion of reinforcement as per manufacturer's specification] [Mode of measurement:The affected surface area of reinforcement shall be considered for payment]

13.25

12349

931.99

... More
Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department]

406.4

42424

104.39

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] With 1:6 cement mortar 20 mm thick plaster 1st floor

178.45

37375

209.44

... More
2nd Floor

238.7

51130

214.2

... More
With 1:4 cement mortar 10 mm thick plaster 1st floor

97.54

15642

160.36

... More
2nd Floor

114.17

18852

165.12

... More
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick)

817.52

118867

145.4

... More
Taking out existing partition/ceiling of particle board, masonite board, ply board, soft board etc. of any thickness and refixing same in new position with necessary clamps making holes in walls, floor, roof and mending damages if any. 2nd Floor

1031.35

67605

65.55

... More
Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system ( T-Grid, load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins / soffit. 6 mm thick High Pressure Steam Cured Non Asbestos Fibre Cement Standard Ceiling Board (Density 1300 Kg/m3) of size 595 mm X 595 mm, conforming IS 14862 & Type B Category III of ISO 8336, tested as per AS-1530 part 3 & BS-476 Part 4,5,6,7 & 8, should be placed in the Grid module to form a False Ceiling. All complete as per the drawing & directions of Engineer-in-charge. In ground floor. False Ceiling (with 6mm thick Fibre Cement Designer Board and E-Grid T- 2430). 2nd Floor

854.72

727324

850.95

... More
Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system (E-Grid U-1520 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins / soffit. 15mm thick OW Acoustic Board (Mineral Fiber Acoustic Ceiling Tiles) of approved patern and size 595mm X 595mm with NRC value 0.65 should be placed in the Grid module to form a False Ceiling. All complete as per the drawing & directions of Engineer-in-charge. Acoustic False Ceiling (with 15mm thick OW Acoustic Board and E-Grid U- 1520). 2nd Floor

176.63

291553

1650.64

... More
Thermal insulation of ceiling with single layer Expanded polystyrene having density more than 20 Kg/m3 fixed with suitable metallic fastener and / or synthetic resin adhesive as per the direction of the Engineer-In-Charge. With Type N- Normal 50 mm thick of density 20 Kg /m3 In ceiling (for AC zone) 2nd Floor

1031.35

395100

383.09

... More
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Malayasian 1st floor

0.27

27240

99417.57

... More
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. 35 mm thick shutters (single leaf) 1st Floor

4.05

12902

3185.68

... More
2nd Floor

11.25

36027

3202.37

... More
Supplying, fitting & fixing of Aluminium fixed partion wall of all aluminium sections viz top, bottom and side member, intermediate member, glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868- 1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium fixed partition wall with glass / panel board all complete as per architectural drawings and direction of Engineer-in-charge. (Excluding cost of glass/ panel board, 10-12 Micron thickness Annodizing film. Natural white. a) for unsupported length of vertical member upto 1.50m. height of both ends of vertical member restrained but panel with in 0.90 sqm 2nd Floor

4146.3

1932135

465.99

... More
Supplying and fitting in all places of wall panelling to all heights and fixing on pre- framed existing frame work grid with glass wool of 50mm thick having density of 48 Kg per cum. to be inserted into the pre - fabricated slot covered the glass wool by marking cloths treated with Naptha @ 0.07 Ltr.per Sq.m. of cloths. Finally 12.5mm thick gypsum Fulton board having size 595mmX595mm fitted & fixed into the pre-fabricated grid and covered the all perifirial gaps of fulton board by self additive fibre tape with necessary filler if required, complete in all respect as per direction of the Engineer-in-charge. 2nd Floor

313.74

441969

1408.71

... More
Supplying fitting & fixing in position 9 mm thick Heavy Duty Cement board - Type- A (High Pressure steam cured, tested as per AS-1530 part 3 & BS-476 Part 4,5,6,7 & 8, density 1450kg/m3, Bond strength 15 N/sqmm fire resistant, termite proof, moisture resistant) reinforced with cellulose fibre manufactured through autoclaving process as per IS : 14862 & ISO 8336, with fibre cement screws in partition excluding cost of supporting structure as per drawings and direction of Engineer-in-Charge complete. 2nd Floor

1279.11

966496

755.6

... More
Supplying, fitting and fixing boiling water resistant ply conforming to IS: 303-1989 bonded with phenol formaldehyde synthetic resin of approved make andbrand fitted and fixed as per design as per approval and direction of Engineer-in-Charge.[excluding the cost of supporting frame work and teak woodbatten/Lipping] 19mm 2nd Floor

70.65

159897

2263.23

... More
12mm 2nd Floor

28

43982

1570.79

... More
Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with propernclipping the sides for better attachment as per direction of Engineer-incharge.The rate includes the cost of labour, adhesive and all incidental charges thereof. In ground floor Glossy/Matt/Suede excluding surface texture or metallic lustre. (i) Thickness of laminate 1.5mm 2nd Floor

1475.52

1459570

989.19

... More
Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white 2nd Floor

213.84

114176

533.93

... More
Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units:- Partly glazed partly panelled or fully glazed single leaf alunminium swing door made of extruded and annodized alloy aluminium sections, fabrication including cutting to proper shape and size, drilling and aligning, fitted with heavy duty hydraulic action floor sping placed in the floor with mending damages,with top pin assembly of approve make and brand, fitted with in built locking arrangement, flush bolt, glazing clips and all other necessary fittings, fixtures, adhesives and joineries, cutting glass of approved make to requisite shape and size fitting with dry set neoprene or EPDM gasketing, cutting to requisite shape and size panel board (prelaminated particle block) fixing them with glazing clips as per drawing, specification and direction of Engineer in charge. 2nd Floor

36

55991

1555.3

... More
Godrej Hydraulic door closer fitted and fixed complete. Heavy type

15

36898

2459.88

... More
Supplying 'Godrej' mortice lock chromium plated with keys 6 levers including fitting & fixing complete.

55

128083

2328.78

... More
Supplying, fitting & fixing Stainless Steel 'D' or 'H' type of size 300 mm x 19 mmtubular Handle with Grade 304, CE certified, marked & conforming to EN -1154, of approved quality of reputed brand as per direction of Eingineer-in-Charge fitted and fixed complete including all incidental charges.

20

37446

1872.32

... More
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987; coloured, toughened glass conforming to IS: 2553-1992 (part-II) 6mm thick

112.22

143507

1278.8

... More
Supplying, fitting and fixing 8mm thick Laminated wooden Flooring Work conforming to EN13329:2006 with plank size not Iess than 1200mmX 190 mm (with unilin/tongue-groove locking arrangement) having 0.2mm thk top abrasive layer over a decorative layer followed by a High-density fibreboard (HDF) having density 940 kg/m3 substrate core over a rasin saturated backing layer and installing through unilin or tongue- groove system (having locking strength not less than 1000 kg/m) over a 2 mm thk underlayer polyurethene foam on polythene sheet 250 micron, over a smooth, flat, hard subfloor free from moisture ( 8%), grease etc. complete in all respect with requisite accessories like end profile, transition profile, reducer 'T' profile etc. wherever required and preparation of base including all other incidental works as per direction & satisfaction of Engineer in charge. Cost of Laminate Floor Accessories only (Skirting,End edge, T- moulding,Reducer )shall have to be added separately, wherever required. (Note: This work should not be executed without specific permission of Superintending Engineer). 2nd Floor

361.13

559083

1548.15

... More
Supplying Laminate Floor Accessories (Skirting, End edge, Tmoulding, Reducer ) to 8mm thick Laminated wooden Flooring Work conforming to EN13329:2006 with plank size not Iess than 1200mmX 190 mm (with unilin/tongue-groove locking arrangement) having 0.2mm thk top abrasive layer over a decorative layer followed by a High-density fibreboard (HDF) having density 840 kg/m3 substrate core over a rasin saturated backing layer and installing through unilin or tongue- groove system (having locking strength not less than 1000 kg/m) over a 2 mm thk underlayer polyurethene foam on polythene sheet 250 micron, over a smooth, flat, hard subfloor free from moisture ( 8%), grease etc. complete in all respect as per direction & satisfaction of Engineer in charge. Cost of labour charge for fitting & fixing of Laminate Floor Accessories only (Skirting,End edge, T- moulding,Reducer )shall have to be added separately, wherever required. (Note: This work should not be executed without specific permission of Superintending Engineer). 2nd Floor

203.1

78669

387.34

... More
Supplying, fitting and fixing boiling water resistant ply conforming to IS: 303-1989 bonded with phenol formaldehyde synthetic resin of approved make andbrand fitted and fixed as per design as per approval and direction of Engineer-in-Charge.[excluding the cost of supporting frame work and teak woodbatten/Lipping] 19 mm 2nd Floor

211

477542

2263.23

... More
Scantling upto 50mm wide and 12mm thick (chamfering or rounding) for ceiling/partion battens including fitting, fixing in position with washers, coach screws etc. complete.: (a) Ordinary teak 2nd Floor

138.25

17136

123.95

... More
Renewing wood moulding (50mm x 37.5m) of panel partition or panel door. (a) With 1st class Best Indian teak. 2nd Floor

90

31428

349.2

... More
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. 100mm. X 75mm. X 3.50mm.

170

13372

78.66

... More
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) 40mm X 6mm, 200mm Length

24

715

29.8

... More
Anodised aluminium skeleton bolt of approved quality manufactured from extruded section conforming to I.S: specification (I.S: 204/74) fitted and fixed with cadmiim plated screws: 450mm long x 10mm dia. bolt.

85

14487

170.43

... More
Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete. 300mm x 16mm dia. bolt.

16

4405

275.31

... More
Anodised aluminium grip handle with base plate of approved quality fitted and fixed complete. With base plate. 300mm grip x 20mm dia rod x 50mm plate x 3.2mm thick.

24

5949

247.89

... More
Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. 300mm long.

20

3957

197.84

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) When the height of a particular floor is more than 4 m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (e) for every 4 m or part thereof) Extra for staging beyond 4 m in any floor (Mode of measurement: area in plan x mean height of staging upto soffit of shuttering above initial 4 m) Front Lobby and Auditorium have double height roof

252.84

18381

72.7

... More
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. (Add extra @ 1% for each addl. floor upto 4th floor and @ 1.25% for each addl. floor above 4th floor) In ground floor.

9.1

46960

5160.49

... More
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor Two Coats Solvent based interior grade Acrylic Primer 1st Floor

5365.78

310154

5780.23

... More
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : Two coats Luxury Quality

5365.78

447667

83.43

... More
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.

189.54

8584

45.29

... More
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : On timber or plastered surface : With super gloss (hi-gloss) - Two coats (with any shade except white)

189.54

18298

96.54

... More
Taking out Mirzapur or glazed porcelain tiles carefully by chiselling from walls or floor including stacking serviceable material as directed.

111.6

14098

126.33

... More
Supplying, fitting & fixing 1st quality Ceramic tiles in WALLS to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile, setting the tiles with 2 mm thick spacer & finishing the joints with 100% stain free, chemical and temperature resistant, anti-becterial and anti-fungal epory grout with approved manufacture to match the colour oftiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m , including spacer- 2mm & finishing the joints with epory grout . (FOR TOTLET WALL OF HOSP|TATS) Area of each tile above 0.09 Sq.m Coloured decorative 1st F Toilet Zone

23.4

33884

1448.04

... More
2nd F Toilet zone

32.4

47110

1454

... More
Supplying, fitting & fixing 1st quality Ceramic tiles in FLOORS to match with the existing work & 4 nos. of keystones (10mm) fixed with araldite at the back of each tile, setting the tiles with 2 mm thick spacer & finishing the joints with 100% stain free, chemical and temperature resistant, anti-becterial and anti-fungal epoxy Brout with approved manufacturer to match the colour of tiles including roughening of concrete surface, if necessary including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-i n-Charge. With Sand Cement Mortar (1: ) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ Z.9LKClSq.m, including spacer- 2 mm & finishing the joints with epoxy Srout . (FOR TOILET FLOOR OF HOSPITALS) Area of each tile above 0.09 Sq.m Coloured decorative 1st F Toilet Zone

27

32951

1220.4

... More
2nd F Toilet zone

28.8

35319

1226.36

... More
Cutting joints of existiall (Granite/ Marble/ Tiles etc,) by 3 mm wide x 7 mm deep & filling the joints with 100 % stain free etc etc epoxy grout etc.

336

32740

97.44

... More
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge

16.41

3247

197.84



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.