Public Works Department Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Public Works Department - PWD Tender
Civil And Construction
Building Construction
Eprocure
Opening Date28 Aug 2024
Closing Date9 Sep 2024
Tender AmountRefer Documents
Costs
EMD
₹ 60,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Wbpwd/sewec /bed /niq-57/2024-25
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WBPWD_740164_1Tender No
WBPWD/SEWEC /BED /NIQ-57/2024-25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://wbpwd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Load : 8 Passenger / 544 Kg
-
-
-
... More
Control: Microprocessor based with AC variable voltage & variable frequency ( VVVF)Simplex Collective Control
-
-
-
... More
Machine:- Energy efficient machine, Gearless Machine Room
-
-
-
... More
Position of Machine Room: Directly above the Lift shaft
-
-
-
... More
Speed: 1 Mtrs./ Sec
-
-
-
... More
Floor served: Ground Floor to 3rd Floor ( G,1,2 3) 4 Stops, 4 Levels, 4 Openings
-
-
-
... More
Landing: 4, all on same side
-
-
-
... More
Total Rise : 13.80 Mtr (Approx) (Bidder should visit the site)
-
-
-
... More
Signals:- Digital car position indicator,car travels direction indicator in car & at all landing with call registration indicator. COP & LOP must have stainless steel face plate silver brushed with surface mounted button with braille.
Button : All buttons on car & landing shall be luminous & encoded with braille on/off switch for Lift, fan, light, toggle switch or key switch for automatic/attendent mode of operation.
Display type: Monochrome/Colour LCD/Segmented LCD/ Scroll.
Operation Push Buttom for lift maintenance & service should be on top of the car.
-
-
-
... More
Leveling accuracy:±5 mm(Micro levelling arrangement)
-
-
-
... More
CAR
-
-
-
... More
Car inside :1200 mm Wide x 1400 mm Deep x 2200 mm Height or As per manufacturer's standard conforming to IS
-
-
-
... More
Car Entrance : clear inside1200 mm Wide x 1400 mm Deep x 2200 mm Height protected with car door
-
-
-
... More
Car Enclosure: Stainless Steel sheet (20 SWG) with Hairline finish with hand rail.Mirror Finish & Rear side Glass.
-
-
-
... More
Lighting: LED Lighting Inside the Car
-
-
-
... More
Car Ventilation: Pressure fan with anodised aluminium grill.
-
-
-
... More
Car Flooring : Car flooring : Decorative granite flooring (As per direcion of EIC and according to this Department's Order).
-
-
-
... More
Car Door: Stainless Steel centre opening automatic door provided with V3F controlled door drive system
-
-
-
... More
Landing Door: Stainless steel centre opening automatic door provided with V3F controlled door drive system
-
-
-
... More
Door Opening: Automatic power oprated door with full length Photocell assembly light curtain sensor
-
-
-
... More
Indicators: Car & Landings: Direction & Position Indicator Display
-
-
-
... More
PROTECTIVE DEVICES & OTHER ACESSORIES
-
-
-
... More
ARD: Automatic rescue device complete with dry maintenance free batteries as required.for automatic evacuation to the nearest floor in case of power failure / single phasing/others.
-
-
-
... More
Overload Protection:Fully loaded with overload protection.On overloading the lift car will not start with door remaining open and give audio display indication
-
-
-
... More
Emergency lighting in car: Battery operated emergency lighting in the lift car.
-
-
-
... More
Intercom system: Battery operated intercom system in Lift Car, Machine Room & Control Room
-
-
-
... More
Emergency Alarm: Battery operated alarm bell system in lift car and control room
-
-
-
... More
Fireman switch:Fireman switch at main landing terminal.
-
-
-
... More
Voice Synthesizer: Voice announcement system (Voice Synthesizer) in the car to announce the position of the elevator in the hoist way as the car passes or stops at a floor served by the elevator.
-
-
-
... More
Main rope - Belt Type or As per manufactures's standard conforming to IS.
-
-
-
... More
DIMENSION OF SHAFT & POWER SUPPLY
-
-
-
... More
Available Shaft Dimension: 2750(W) mmX 1750 (D)mm
-
-
-
... More
Pit Depth : 1600 mm (Bidder should visit the site)
-
-
-
... More
Overhead : 4500 mm (Bidder should visit the site)
-
-
-
... More
Electric power supply: AC 415 Volt 3phase, 50 Hz, terminated in machine room as per IS
-
-
-
... More
8 Person Passenger Lift with Machine room and having specification same as above with additional features as per PWD Act 1995 ( As per attach Annexure-I)
2
-
-
... More
N.B. Bidder should see the "actual physical well size '' and no extra cost will be paid for additional fabrication of angle iron structure, iron clamp or any other mechanical works. Rates should be quoted with Minor Civil work (i.e Chieseling inside the lift well ,necessary pocket cutting, making hole on machine room floor etc. incl mending good the damages should be made by the respective agency.
-
-
-