Public Works Department Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Public Works Department - PWD Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date22 Nov 2024
Closing Date11 Dec 2024
Tender AmountRefer Documents
Costs
EMD
₹ 29,500Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WBPWD_772463_1Tender No
WBPWD/EE/AED /eNIQ-83/2024-25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://wbpwd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
12
-
-
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [For AC]
12
-
-
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch with indicator & 20A Switch type MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240 x 200 x 65 mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required ( Computer Board ).
6
-
-
Supply & Fixing 240 V, 2 x 6A, plug socket with separate 2 x 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240 x 200 x 65 mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
18
-
-
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS.
2+12Way[ Legrand/ABB/L&T ]
6
-
-
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-[ Legrand/ABB/L&T ] 40 A DP
6
-
-
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Legrand/ABB/L&T ] 6-32 A SP
72
-
-
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required incl. necy. fittings as required as per GS.
2 x 1.5 sqmm + 1 x 1.5sqmm
550
-
-
2x(2.5 sqmm)+1x(1.5 sqmm).
840
-
-
2x(4 sqmm)+1x (2.5 sqmm).
650
-
-
2x (6 sqmm) + 1x (4 sqmm).
112
-
-
Cutting Channel of size (31 mm x 31 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 13 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools
and tackles
13 mm dia 3 mm thick polythene pipe without earth continuity wire
2040
-
-
Making holes on RCC ceiling 125 mm depth having dia of following sizes : 125 mm depth, 50 mm dia.
8
-
-
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
2.5sqmm.
250
-
-
1.5 sqmm.
250
-
-
4 sqmm.
100
-
-
Supply of 2/4 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make MESCAB/RR/Gloster]
2Core 10 Sq. mm
345
-
-
4Core 6 Sq. mm
315
-
-
4Core 35 Sq. mm
65
-
-
Laying of cable upto 35 sqmm in underground trench as per GS for the following numbers of Cables.
65
-
-
Laying of cable after cutting floor/pavement/wall as per GS for the following Sizes.as per GS upto 35 sq.mm
345
-
-
Laying of cable upto 2/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting.
315
-
-
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. 6 Sq. mm
12
-
-
35 Sq. mm
2
-
-
10 Sq. mm
14
-
-
Fixing only single/twin LED light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
24
-
-
Fixing only LED lamp.
46
-
-
Fixing only outdoor / street light type fluorescent light fitting or MVlight fitting complete with all accessories to be fixed /projectedfrom the wall of the building incl. making holes/providing clampingarrangement & necy. GI reducer as required. S&F 40 mm GI pipe(ISI-Medium) quality 1.5 mts. average length having suitable bendS&F necy. length of 1.5 sqmm PVC insulated single core strandedannealed copper wire and making connections as required andmending good damages to wall incl. painting etc.
6
-
-
Supply of 230V 50HZ Single 4ft pc body LED light fittings with Led tube (20W) incl. other accessories - Single (Philips cat no.TMC 502 1xT-LED/ crompton greaves/Havells/Bajaj).
With 2 yrs warranty.
24
-
-
S&F 90W LED out door luminaire on arm bracket. [Make- Phillips BRP265 LED 106CW M2FGPSUGRELP/ CROMPTON GREAVES/BAJAJ]. With 3 yrs warranty.
2
-
-
Supply & Delivery of minimum 70 Watt or higher (Minimum lumen efficacy- 110 Lumen/Watt) Street Light with fittings & fixures (for street light) (Make: Crompton / Wipro/ Bajaj / Havells ) as per direction of EIC. [Phillips BRP062 LED 80 CWSLC AISI PSU/CROMPTON GREAVES/HAVELLS].
With 3 yrs warranty.
6
-
-
Supply 9W LED lamp to the lamp point incl angular batten Holder. [PHILIPS/Havells/Crompton] .
46
-
-
Inter connection between Loop Box to fittings by 1.1 KV 3 x 2.5 sqmm single core stranded 'FRLS' PVC insulated & unsheathed copper wire (make-Finolex/Havells/KEI) through 19 mm size PVC pipe incl. necy. fittings as required as per direction of EIC
30
-
-
Supplying & Fixing of PVC water proof type Loop box (Make-Sintex) of size 8"x 10" comprising of 4 way 100 Amp. Capacity brass stud/terminal make- AC /DC.,having hinged PVC top cover & 4 mm thick with rubber gasket lining,railway type mechanical locking arrangement,comprising of one 250V,15A kit-kat fuse unit,one NL on porcelain insulator etc. conceal in wall as per direction of EIC.
6
-
-
Supplying and fixing Timer panel M S Box with hing type front open door and threathed locking arrangement in one side made of 18 SWG CRCA MS Sheet of size 500 x 300 x 200 mm. fixed in wall on flate iron frame as per direction EIC.The Box shuld comprising following accessorise. A) 230 V , 50 Hz ,16 Amp Single dial 1 x 24 Hrs.Timer back up by nickle cadmium battery (Make - GEC / Legrand ) – 1 no B) One no. ML-3 conctractor with ( 2 NO or 1 NO + 1 NC Aux. Contract ) ( Make - Legrand / L & T ) – 1 no C) 4 pole 32 Amps MCB ( L & T / Legrand ) - 1 no D) Auto / Manual By pass Toggle Switch arrangement – 1 no. E) 250 V , Diode type neon Indicator lamp ( Make - Legrand/ PWD Appvd ) – 1 no F) Bakelite base with FP bolt type stud / Terminal block incl S & F Neutral Bar , with spring washer ,nuts etc with this box for termination of power to complete arrangement must be wiring by 4 Sq mm PVC insulated 'FRLS' Cu wire with suitable length incl socketing /lugs etc as per requirement & direction of EIC (for controlling outdoor street light fittings)
1
-
-
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
18
-
-
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991).
10
-
-
Fixing only exhaust fan after making holes in wall as per GS. (9") .
12
-
-
Supply & Fixing louver shutter ( Aluminum)on wall with necy. bolts & nuts (6 mm dia x 62 mm long) as per GS. (9")
12
-
-
Providing CC (6:3:1) muffing 450x450x600 mm in size or equivalent size of cylindrical muffing above ground level around the pole base complete with 3 mm thick neatly finished cementplaster all round after dismantling the unserviceable muffing if any incl. fixing only loop box if necessary, without Loop Box.
2
-
-
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand aper/emery paper, cleaning etc. for receiving fresh coat of paint (Upto 9.0 mtr. long pole)
1st coat of aluminium paint over 1 coat of RO priming
10
-
-
2nd coat
10
-
-
Dismentling the existing meter room Electrical accessories by Co's own tools & tackles by maintening normalcy as far as possible as per direction of EIC. and the agency have to refixing that electrical meterials after civil works done by their own arrangements.
1
-
-
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) as per GS
6
-
-
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings as per GS.
40 mm dia
10
-
-
Supplying and fixing 415V, 100A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.(approved make, as per choice of EIC).
1
-
-
Supplying and fixing 415V, 63A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (approved make, as per choice of EIC).
1
-
-
Supplying and fixing 240V, 32A DP Main Switches on flat iron frame on wall with suitable size angle iron frame.(approved make, as per choice of EIC).
6
-
-
S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered/ welded with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. complete duly grouted on the parapet etc. in CC mortar ( 4:2:1), including thimble joints of 7/16 SWG wire and (25 x 6) mm GI strip with SS nuts, bolts & washers.
4
-
-
Supply & fixing of 25 mm x 6 mm thick GI (Hot Dip) flat / strips for Horizontal & Vertical run on wall / floor with GI shaddles as required including drilling holes, bolts, nuts, washers, etc./ and mending good the damages to building works .
55
-
-
Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works: i) Length upto 0.5 Mtr
4
-
-
ii) Length above 0.5 Mtr
12
-
-
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run.
16
-
-
Supply & Fixing of Testing Joints by 25 mm x 6 mm thick GI (Hot Dip) strip 125 mm long on wall after making suitable arrangement to establish a clearance of 50mm from wall for making junction connection with vertical conductor and conductor from earth electrode complete with S & F GI bolts, nuts, check-nuts, spring washers etc. as required. (Rate arrived from G.S.
4
-
-
Earthing with 65 mm dia GI pipe (TATA-Medium) 3.0 Mts. long with welded 2 nos. half circle bracket made of GI strip (65 x 8) mm. with two holes on extended portion of the each strip of length min. 250 mm , and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts.
4
-
-
Excavation of soil for installation of Earth Electrode and filling & ramming as to GS. (For morum soil).
8
-
-
Supply, Laying & Fixing of 50mm x 6mm galvanized (Hot Dip) steel strip in underground trench for interconnection between the Earth Points by joining (As per item no 11).
40
-
-
Jointing for Horijontal & vertical run of GI strip through welded joint of (25 x 6) mm or (50 x 6) mm GI Strip to Lap joints/ 'T' joints, etc. and painting the joints with 2 (two) coats of bituminous paint.
26
-
-
Supplying & fixing earth busbar including Connecting the equipments of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS.
1
-
-
Excavation of soil for installation of Earth Electrode and filling & ramming as to GS. For morrum soil
4
-
-
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With ISI-Medium GI pipe as per GS
2
-
-
Connecting the equipment’s body to earth bus bar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipment’s incl. drilling holes, with bolts, nuts, washers etc.
12
-
-
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire 6 SWG size on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.
350
-
-
Add GST @18% On total from item no 1 to 55.
1
-
-
Add LWC @1% On total from item no 1 to 56.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%