Public Works Department Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Security and Emergency Services
Eprocure
Opening Date28 Jun 2024
Closing DateCancelled
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Wbpwd/sewec /hed /niq-26 /2024-25

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. as per G.S. [16/C-2]

27

-

-

... More
S&F of 240V, 60W LED street light with IP65 protection complete with all accessories ( Make:- Surya Lexon/Benlo ultima/ Orient FIESTA PLUS PC) . [With 5 years on site warrenty]

8

-

-

... More
S & F mini pole on roof top by 80 mm dia., 2 Mtr. Long GI(M) pipe medium quality (Bansal/Jindal make) incl. making cc (6:2:1) muffing 600x600x750 mm in size with 3 mm thick neatly finished cement plaster incl. S & F 8”x6”x4” C.I. looping cable box incl. S & F 40 mm. dia. G.I.(M) 1.5 Mtr. Long arm bracket for fixing flood light & neccy connection by 2x 1.5 sq mm Cu wire. This is incl. painting as per GS.

8

-

-

... More
S&F of 250V single timer DB (equivalent to 10 way SPNDB in size) with double acrylic door sheet steel enclosure, neutral bar, din rail, with lP43 protection comprises with 32A DP MCB(C-curve 10ka) and 1 no 24 hr digital time switch and 1 no. 25A modular type power contactor complete with internal wiring with suitable size of copper wire includ LED indicator and earthing attachment as per direction of EIC. [NS]

1

-

-

... More
SUB-HEAD 2 - SUPPLY OF LIGHT FITTINGS

-

-

-

... More
Supply of single 4ft LED box type batten complete with all accessories as per direction of EIC. [ Make: Surya/ Orient/Benlo]. [With 3 years on site warrenty]

37

-

-

... More
Supply of Dual 4ft LED box type batten complete with all accessories . [ Make: Surya/ Orient/Crompton]. [With 3 years on site warrenty]

52

-

-

... More
Supply of Dual 4ft LED water proof industrial luminaries with batten with polycarbonate housingand diffuesr with IP66 protection complete with all accessories. [ Make: Surya/ Orient/Crompton]. ]. [With 3 years on site warrenty]

12

-

-

... More
Supply of Single 4ft LED water proof industrial luminaries with batten with polycarbonate housingand diffuesr with IP66 protection complete with all accessories . [ Make: Surya/ Orient/Crompton]. [With 3 years on site warrenty]

5

-

-

... More
S&F 20/18W LED T-8 lamp with polycarbonate diffuser and metal heat sink. [ Make: Surya/ Orient/Crompton]. [With 3 years on site warrenty]

155

-

-

... More
SUB-HEAD 3 -- FIXING OF FANS

-

-

-

... More
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush and making necessary connection as required by 2x1.5 sqmm flexible copper wire. etc as per GS [ 21 (a) / C-3 ]

40

-

-

... More
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter as per GS.

-

-

-

... More
(9") [ 28(a)/C-4 ]

9

-

-

... More
(12") [ 28(b)/C-4 ]

12

-

-

... More
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long)as per GS

-

-

-

... More
(12") [ 33/D-14 ]

21

-

-

... More
Fixing only cabin/Wall fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length as per GS.(29/C-4)

10

-

-

... More
SUB-HEAD 4 -- SUPPLY OF FANS

-

-

-

... More
Supply and delivery of 230V 1200mm sweep ceiling fan [Make: Usha Model: Striker 1200 of equivelent model of CG/Orient] as per direction of EIC.

40

-

-

... More
Supply of Exhaust fans of following diameter complete with all accessories as per direction of EIC. ( Make -EPC/Crompton/Usha )

-

-

-

... More
9"( 230mm ) Speed 1370 RPM [NS]

9

-

-

... More
12"( 300mm ) Speed 1420 RPM [NS]

12

-

-

... More
Supply of 450mm sweep High Thrust wall fan(high speed) with metal body, canopy & blades(Orient - Wall AC18 or equivalent model of CG/EPC/Cinni) with necessary nuts, bolts, washer etc. as per direction of EIC.

10

-

-

... More
SUB-HEAD 5 -- Glow Sign Board

-

-

-

... More
Supply & delivery of LED Tube illuminated sign board fabricated by 10''(L)x4'(H)x10"(W) ACP box supported with 35 x 35 x 5 mm M.S. Angle structure all around with 40mm x40mmx 1.62 mm Al. edge angle for front portion only.The front side of the cover will be fabricated with hinges and arrangement in such a way so that it can be opened for maintenance purpose, including mechanical locking arrangement .The 3 mm ACP facial (Blue colour) should be provided with laser cutting of 6 mm laser cut Acrylic letters out of which 5 mm rising and back portion of the ACP board should be pasted with 2mm thick Clear Acrylic Sheet of same size as ACP facial as per the direction of EIC.The sign board should be illuminated by 18W LED Tube lamps (10 nos.) (Type- MAS LED Tube lamp 18 W 2100 lm) with Tube fittings (Phillips make) to be fixed by hooking arrangement with iron stucture fabricated for fixing purpose. Distribution wiring for power supply to LED fittings to be done by PVC rigid conduit, necessary clamps, cable tie etc. Back side of the of the board should be covered with 20 SWG G.I. sheet to protect rain water. The matter to be displayed will be finalised by authority and to be given later.This fabricated display structure is to be fixed on the top of prefabricated iron structure as per direction of EIC.

1

-

-

... More
Fixing of glowsign bloard directly on wall using 3 nos. 4 ft height 50x50x6 mm MS Angle fabricate as C type. Both the end of MS angle should be grouted on wall by using cement concerete & mending the damages incl painting of the iron frame. The glowsing board fixed of the iron structure at the height between 12 to 24 feet from GL by suitable size of nut & bolt incl. hiring of welding machine, manpower & crane if required as per direction of EIC.

1

-

-

... More
SUB-HEAD 6 -CABLE, LAYING, GLAND & SOCKET

-

-

-

... More
Supply of XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make:- RR/KEI /Polycab] [NS]

-

-

-

... More
2 Core 10 Sqmm

150

-

-

... More
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting as per GS. [2(a)/F-1]

150

-

-

... More
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below as per GS.

-

-

-

... More
2 Core 10 Sqmm [7©/F-4]

19

-

-

... More
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials as per GS.

-

-

-

... More
2 Core 10 Sqmm [8(b)/F-5]

19

-

-

... More
Supply, delivery and laying underground XLPE Insulated & Sheathed Armoured Aluminium Conductor cables 4 Core 150 Sqmm [ Make:- RR/KEI /Polycab]

120

-

-

... More
Installation of FDA System

-

-

-

... More
Supply, Installation, Testing & Commissioning of Microprocessor controlled. IP Addressable Multi-sensor detector (VDS / UL /ERTL/ LPCB / FM approved) with inbuilt optical smoke Sensors and heat detector sensor with inbuilt short circuit fault Isolator as per NFPA style 7 wiring complete with base (Note Detectors without built-in fault isolator is also acceptable Provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. Thedetector should have 360 degree optical view with single/ multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors as per direction of EIC. (Make Esser by Honeywell / Secutron / Securiton/Johnson Control/ Cerberus Pro By Siemens /GST / Miacom)

68.4

-

-

... More
Supply, Installation, Testing & Commissioning of Microprocessor controlled IP Addressable Heat detector( VDS / UL/ ERTL / LPCB / FM approved ) with combination of fixed type & Rate of Rise of Temperature feature. Detector shall have minimum triggering temperature programmable from 60 deg. C to 880 degree. CC.., Having high lleevveel oof immunity to electromagnetic influences and show alarm signal limit temperature is reached. Detector shall have inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator as per direction of EIC.(Make Esser by Honeywell / Secutron / Securiton/Johnson Control/ Cerberus Pro By Siemens /GST / Miacom)

4

-

-

... More
Supply, Installation,Testing & Commisioning of IP Addressable Manual Call Point ( VDS / UL / ERTL / LPCB / FM approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required as per direction of EIC. (Make Esser by Honeywell / Secutron / Securiton/Johnson Control/ Cerberus Pro By Siemens /GST / Miacom)

4

-

-

... More
Supply, Installation, Testing & Commissioning of IP Addressable Loop Powered Hooter (sound output of minimum 80 db ) cum strobe (strength of iight 10 cd) complete with inbuilt short circuit fault isolator. (VDS / UL / ERTL / LPCB / FM approved) approved as per direction of EIC. (Make Esser by Honeywell / Secutron / Securiton/Johnson Control/ Cerberus Pro By Siemens /GST / Miacom)

4

-

-

... More
Supply, Installation, Testing & Commissioning of Loop Isolator Modules ( VDS / UL /ERTL/ LPCB / FM approved ) Loop Isolator can isolate the shorted circuit from the whole system to ensure normal operation of other devices and locate the devices in fault. After the short circuit fault is cleared, those devices will be re-introduced into the system with degree of protection IP 30 as per direction of EIC. (Make Esser by Honeywell / Secutron / Securiton/Johnson Control/ Cerberus Pro By Siemens /GST / Miacom)

2

-

-

... More
Supply, Installation, Testing & Commissioning of Microprocessor based addressable fully networkable 2 loop fire alarm control panel (VDS / UL/ERTL/ LPCB/ FM approved) suitable for the devices as stated in the previous items of this BOQ along with 20% spare capacity with each loop loading not exceeding 80 % of the full capacity of detectors and devices taken together, complying to IS 2189:2008 or its latest amendments, and with minimum 600 character alpha - numeric liquid crystal display with CAN networking,The panel shall be soft addressable type and shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches with help monitor module whenever any alarm is triggered. The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards.

1

-

-

... More
The panel should have extra loop card slot for expansion of capacity twice. The panel shall have in built rectifier, provision for external & internal printer ( if required ), Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, inbuilt Surge protection facility, integral SMF lead acid batteries with sealed cells of 24V capable of running for 24 hours normal working and then be capable of operating the system for 60 minutes during Emergency condition, with integral battery charger complete in all respect as required. The FACP shall be capable of being networked (future expansion) with other similar FACP located at different part of the premises through single RS 485 modbus. The FACP shall have provision for interfacing with the public address system, remote computer and BMS interface. The system must be preloaded with licensed software as per direction of EIC. (Make Esser by Honeywell / Secutron / Securiton/Johnson Control/ Cerberus Pro By Siemens /GST / Miacom)

-

-

-

... More
NOTE :- 1) The Fire Alarm system shall comply with latest requirements of -- (i) National Fire Protection Association (NFPA) standards, (ii) IS 2189 (iii) NFPA 7O National Electric Code, (iv) NFPA 72 National Fire Alarm & Signaling Code (v) Local Statutory Regulations , (vi) Manufacturer Recommendation vii) System should be integrated with the components like FACP, Detectors, MCP, Hooter, Monitor Module, Relay Module, etc. and all these components should be of same brand.

-

-

-

... More
TESTS :- 1) The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system. 2) Before energizing the cables and wires, inspection and check for correct connections, and test for short circuits, ground faults, continuity, and insulation and other tests as per applicable Indian/International standards must be done.

-

-

-

... More
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required as per GS.

-

-

-

... More
2 x 22/0.3 (1.5 sqmm) [1(a)/E-9]

1036

-

-

... More
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works as per GS.

-

-

-

... More
20mm size [7(a)/E-16]

1036

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.