Public Works Department Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Public Works Department - PWD Tender
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date19 Nov 2024
Closing Date10 Dec 2024
Tender AmountRefer Documents
Costs
EMD
₹ 36,375Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WBPWD_770888_1Tender No
WBPWD/EE/S24PED/eNIT80_2nd Call/24-25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://keralapwd.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Engine Type : 4 Stroke Diesel Engine
-
-
-
RPM : 1500
-
-
-
Rated Output : 125 ВНР or Higher
-
-
-
Duty : PRIME rating 80 kWe
-
-
-
Cooling : Water cooled with radiator
-
-
-
Cylinder : 6
-
-
-
Aspiration : Turbo Charged
-
-
-
Type of Govemer : Electronic
-
-
-
Fuel Tank Capacity : Minimum capacity 290 Ltrs.
-
-
-
Fuel Consumption at 75% rated Load with Radiator or Fan : 18.4 Ltr./ Hr. or Less
-
-
-
Fuel Consumption at 100% rated Load with Radiator or Fan : 24.4 Ltr./ Hr. or Less
-
-
-
Overload Capacity : 10% overload for one hour for every 12 hours continuous running at full load or better.
-
-
-
Engine instrument Panel : Consisting of starting switch with key, lube oil indicator, water temperature indicator, RPM indicator and hour meter. Having indication/LCD display for lub oil pressure, battery voltage, engine rpm, fuel level in the day tank, engine running hrs. indication, AC current, AC Voltage, AC frequency, AC power metering with suitable CTs for dispalying the electrical parameters.
Safety alarms for high engine temperature, low lub oil pressure, low raditor water level, low fuel level, battery high voltage, under/over speed along with safety trips for high engine temperature, low lube oil.
-
-
-
Safety Controls: Emergency Stop, Low lube oil pressure warning/ Shutdown, High water temp, warning/ Shutdown, Sensor failure indicator, Engine over speed indicator, Battery charging and low battery indicator.
-
-
-
Exhaust Silencer : Residential Type.
-
-
-
Starting system: 12V/24V starting system complete with starter motor, charging alternator with rectifier and Cutout as per manufacturer standard.
-
-
-
Battery : Lead Acid, Low Maintenance or SMF and conforming to relevant IS Specification with Low/High Battery Voltage and Weak Battery warning
-
-
-
ALTERNATOR
-
-
-
Make : STAMFORD / KIRLOSKAR GREEN / GREAVES POWER / MAHINDRA / LEROY SOMER / LEY POWER / VOLVO
-
-
-
Rating : 415V, 3Ph, 50 Hz,100 KVA, 1500 rpm
-
-
-
Type : Brushless, self excited and self regulated
-
-
-
Insulation : Class H
-
-
-
Protection : screen-protected drip proof with min. IP-23 degree of protection
-
-
-
RPM : 1500
-
-
-
Voltage Regulation (max) : ±1%
-
-
-
Winding connection : Star with Neutral
-
-
-
Total Distortion factor : Less than 3%
-
-
-
Total Harmonic distortion in output waveform : 5%
-
-
-
Should have provision for Neutral Grounding.
-
-
-
ACOUSTIC ENCLOSURE
-
-
-
The DG set should have integrated acoustic enclosure at the manufacturing state itself. High quality acoustict enclosure must be certified as per CPCB-III norms.
-
-
-
BASE FRAME
-
-
-
Common iron channel fabricated base frame containing the engine and alternator, mounted on AVM pads and having provision for lifting Hook.
-
-
-
TERMS & CONDITIONS
-
-
-
Rate should be quoted inclusive of all applicable taxes and Duty etc.
-
-
-
All materials, equipments & accessories must conform to relevant IS /IЕС specifications. The DG Set to be supplied must be from the authorized OEM of the respective Engine Manufacturer.
-
-
-
Necessary manufacturer's test certificate for Diesel Engine, Alternator etc. Will have to submit in triplicate copy during delivery of the equipment.
-
-
-
Copy of "Type Approval Certificate" and Certificate of "COP" must be produced at the time of delivery issued from competent Authority (As per CPCB-IV+).
-
-
-
Circuit Diagram for AMF Panel must be submitted from the Manufacturer / OEM.
-
-
-
The entire set must be warranted at least 15 months from the date of Delivery/12 months/ 5000 Hrs from the date of Commissioning whichever is earlier. However Engine & Alternator should be warranted of 2 years/5000 Hrs, whichever is earlier. Necessary spare/lubricant incl. necessary service as per OEM standard should be provided by the agency during the warranty period.
-
-
-
AMF PANEL
-
-
-
Cubical type floor mounted AMF panel made from 16 SWG Sheet Steel, duly pretreated, powder coated painted and aesthetically finished, suitable for controlling of 100KVA DG set having following specification/features.
-
-
-
415V, 160A, 4P, 36kA MCCB with adjustable O/L, S/C, E/F protection release - 2 sets (Make - ABB / Siemens / L&T).
-
-
-
415V, 160A, 4P, AC/DC operated contactor with suitable nos. of NO & NC contacts -2 sets (Make - ABB / Siemens / L&T).
-
-
-
In Built By-Pass switch (415V, 160A, 4P Change Over) for rated capacity (Make - ABB / Siemens / L&T).
-
-
-
On - delay timer for load change over (Make - ABB / Siemens / L&T).
-
-
-
On - delay timer for engine shut off (Make - ABB / Siemens / L&T).
-
-
-
Engine On-Off switch (Push button type) (Make - ABB / Siemens / L&T).
-
-
-
Battery charger complete with voltage regulator, booster selector switch, on-off switch, voltmeter and ammeter for charging the battery from mains. This will be in addition to the battery charging alternator fitted on the engine.
-
-
-
Minimum five number indicating lamps to indicate 'Mains ON', 'Load on Mains', 'DG set Running', 'Load on DG set' and 'Battery Charger ON'.
-
-
-
Audio visual alarm for 'Low lubricating oil pressure', 'High water temperature, Start failure', and DG over load'.
-
-
-
Mode selector for setting the panel on Auto/ Mannual/Test Mode
-
-
-
Microprocessor based relay with composite meter for digital display of following - Generator voltage/AC Mains voltage, Current in all phases, Frequency, Powwer Factor, Energy.
-
-
-
Running time indications number of hours of operation and service intervals, service due indications.
-
-
-
The AMF panel must be designed to ensure trouble free performance and ensure switching over Electrical Load to DG within 15 (fifteen) second from the instant of mains failure.
-
-
-
SUPPLY & INSTALLATION EXHAUST STACK
-
-
-
Exhaust Pipe Extn. Work by building wall support with 4" pipe including Thermal insulation (Cladding) by Mineral wool, Aluminium sheet etc.
8
-
-
Exhaust Pipe Extn. Work by building wall support with 6" pipe including Thermal insulation (Cladding) by Mineral wool, Aluminium sheet etc.
10
-
-
DG Silencer Cladding work with mineral wool, Aluminium sheet etc.
1
-
-
Supply & fixing of Iron angle for holding the above exhaust pipe.
100
-
-
S&F rain protection pipe.
1
-
-
SUPPLY & LAYING OF CABLE
-
-
-
Supply & Delivery 1.1KV grade Al/XLPE/SWA/PVC cable as per choice of EIC.
a) 4C × 70 sqmm (M/S to AMF Panel & AMF Panel to Change over)
230
-
-
Laying only Cable above 50 sqmm but not exceeding 400 sqmm through existing RCC/ Hume/GI Pipe/open masonary trench for single, 2, 3, 3½ and 4 core.
30
-
-
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
200
-
-
S&F compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
-
-
-
4 Core 70 Sq.mm
10
-
-
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket, tapes, anticorrosive paste & jointing materials.
-
-
-
4 Core 70 Sq.mm
10
-
-
Supplying & fixing medium gauge GI Pipe (ISI-Medium) Protection with necessary fittings and jointing metarials as required
-
-
-
80 mm dia GI pipe
30
-
-
Supply & laying of 1.1 KV grade 7 core 2.5 sq.mm. PVC copper conductor control cable partly recessed and partly by shaddle on wall to interconnect DG set with AMF panel. (Make - RR Kable/Finolex/Havells)
20
-
-
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
2.5 sqmm
7
-
-
EARTHING
-
-
-
Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S&F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts (2 nos. for DG neutral & 2 nos. for DG body earthing).
4
-
-
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work (1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
4
-
-
Extra for treatment of soil by using salt & charcoal or coke for plate electrode.
4
-
-
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
2
-
-
Supply & laying 1.1kV grade ISI marked 25 sqmm single core standard copper wire for DG neutral earth (Make: Finolex / Havells/ RR Kable)
5
-
-
Connecting the equipments body to earth busbar including S&F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
10
-
-
Supplying and fixing 415V, 160A TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc.(MAKE-L&T/HPL/Havells)
2
-
-
NOTES: 1. The Agency must procure the materials from the manufacture / OEM or from their authorised sales channel so that the standard warranty/support of the manufacture / OEM becomes applicable to the products to be delivered and installed by them.
2. Documents that authenticates such procurement from the manufacture / OEM or from their authorised sales channel and standard warranty/support should be sent from the e-mail of the manufacture / OEM / authorised sales channel to the e-mail of Engineer-in-charge and hard copy of it to be submitted during execution of work/submission of Bill.
3. If any refurbished material is supplied and installed, Penal action will be will be taken as per existing rules.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%