Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Public Works Department - PWD Tender
Civil And Construction
Building Construction
Eprocure
Opening Date16 Dec 2024
Closing Date4 Jan 2025
Tender Amount₹ 16,32,436
Costs
EMD
₹ 32,649Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WBPWD_785676_2Bid Award Id
ViewTender No
WBPWD/BSTD/EE/NIT58e/24-25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://wbpwd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
(a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water
in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department]
158.12
88
13915
... More
(b) Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4
cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. (No Departmental Cement is required)
754.51
258
194664
... More
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed.......
(a) Depth of excavation not exceeding 1,500 mm.
31.5
119
3757
... More
(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with
water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
(B) Do - by fine sand
3.38
1317
4445
... More
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
45
361
16245
... More
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
45
24
1080
... More
(I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor
(A) [Pakur Variety] (a) 1:3:6 proportion
4.5
5248
23618
... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 (a) For works in foundation and upto roof of ground floor/upto 4 m
II. Other than
SAIL/ TATA/RINL
0.49
54547
26837
... More
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor
as per relevant IS codes.
(i) Pakur Variety
54.85
6087
333908
... More
Labour for Chipping of concrete surface before taking up Plastering work.
754.51
21
15845
... More
Taking out old damaged tarfelt from the roof, parapet etc. preparing the roof surfaces by removing all spoils, blisters, moss etc. from the working site and disposal of the same beyond the compound and cleaning the site in all respect as
per direction of Engineer-in-Charge.
754.51
12
9054
... More
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
12.78
728
9311
... More
Brick work with 1st class bricks in cement mortar (1:6)
(b) In superstructure, ground floor
33.31
5591
186238
... More
Cement concrete (1:1.5:3) with graded stone chips 5.6 mm size with hexagonal square mesh wire netting, I.R.C. fabric mesh or X.P. M. fitted and fixed after tying the existing reinforcement on concrete without distributing
a) 20 mm thick
26.26
491
12894
... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:4 cement mortar (a) 20 mm thick plaster
75.77
189
14328
... More
(b) 15 mm thick plaster
304.27
163
49672
... More
(c) 10 mm thick plaster
117.83
130
15383
... More
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc.
NOTE:Cement 0.152 cu.m per100 sq.m.
85
32
2785
... More
Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using (I) With application slurry @1.75 kg/ Sq.m, 20 mm sand
cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment.
(A) Deep Colour & White
50.65
1696
85924
... More
Supplying, fitting & fixing best quality digital printed Ceramic tiles in coloured decorative on walls and floors to match with the existing work & 4 nos. key stones (10mm) fixed with adhesive 4.5 mm thick at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. With polymerised adhesive and epoxy grout pointing including spacer - 2mm (When tiles are laid over existing hard ready surface) all complete as per direction of Engineer-in-charge.
60.15
1060
63759
... More
18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m]
41.21
1016
41893
... More
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly,complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor:
(a) One Coat
349.05
31
10960
... More
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.
In Ground floor (Two Coat) b) Premium 100% Acrylic Emulsion
349.05
84
29320
... More
Applying Interior grade Acrylic Primer of approved quality and brand
on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (a) One Coat i) Water based interior grade Acrylic Primer
278.35
30
8573
... More
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) ii) Luxury Quality
278.35
70
19485
... More
Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall)
(i) 3 mm thick (weighing 7.4 kg/Sq.m)
4.4
477
2099
... More
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. (a) For Exposed Work PVC Pipes
(Dia) 15 mm
23
101
2323
... More
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer
2
5128
10256
... More
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes,
fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in (a) For Exposed Work
(i) CPVC Pipes Class-1, SDR-11
40
106
4240
... More
PVC Door Shutter-37 mm thick:
Supplying fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C. multicavity hollow chamber of suitable size and section with 2.0 mm (+/-0.2 mm)wall thickness, the section will have 2nos. built in beads, horizontal & vertical section shall be fixed to each other by self tapping screws and 2 nos. of solid plastic or M.S. tubular galvanised brackets of length 200mmx80mm and
other100mmx100mm both 1.20 mm in each corner of the shutter frame for placing hinges. Polymer based multicavity hollow section of 105 mm x37mm with 2.0 mm (+/- 0.2 mm) wall thickness will In ground floor
2.85
2287
6518
... More
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal
Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx)
5.1
9077
46293
... More
Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm (i) In Roof:-
a) With 0.5 mm thick sheet
4.02
787
3164
... More
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame
exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (d) Sal : Local.
0.08
77671
6214
... More
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately)
(c) 40mm X 6mm, 125mm Length
6
20
120
... More
Supplying, fitting and fixing bib cock or stop cock. (e) PTMT (Polytetra Bib Cock / Stop Cock ( Prayag or equivalent) 15 mm
10
154
1540
... More
A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :
(a) On timber or plastered surface : With other than hi-gloss of approved quality- (iv) Two coats (with any shade except white)
34.13
75
2560
... More
(b) On steel or other metal surface :
With other than hi-gloss of approved quality-
(iv) Two coats (with any shade except white)
34.08
72
2454
... More
Partition of teak veneer [1 mm] as per design fitted and fixed complete (excluding the supporting frame work & necessary teak wood battens): In ground floor
(i) 4mm thick commercial quality
7.6
465
3534
... More
Supplying, fitting and fixing boiling water proof ply conforming to IS: 710-1977 bonded with phenol formaldehyde synthetic resin conforming to IS: 848-1974 of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in Charge. [excluding the cost of supporting frame work and teak wood batten/Lipping] In Ground Floor (iv) 12mm
7.6
1709
12988
... More
Wall panelling / partition with Melamine faced 3 layered flat pressed wood particle board of approved make and brand as per direction of Engineer - in -Charge of requisite grade bonded with phenol formaldehyde synthetic resin conforming to IS: 848 - 1974 (excluding the cost of supporting frame work and teak wood battens / lipping)In Ground Floor (B) Prelaminated particle board conforming to IS: 3087 - 1985 and IS 12823 -1990.
i) One side decorative laminated
a) Exterior grade 12mm thick
7.6
1070
8132
... More
Polyurethane Polishing to woodwork with required colour as approved byEngineer-in-Charge with preparing surface including scaffolding and hire charges of compressor machine including cost of filler and hardenermaterial such as P. U. Sealing, P. U. Top coat (Matt/Glossy), Thinner, Spirit etc. and inclusive of all operation, material and labour complete as
per direction of Engineer-in- Charge.
7.6
837
6361
... More
Ceiling with 12mm thick wooden planks fitted and fixed complete (excluding the supporting framework) as per direction of the Engineer-in-charge. In Ground Floor
(a) Ordinary Teak
7.6
1457
11073
... More
Supplying solid flush type doors of deluxe decorative (both side) quality, conforming to I:S 2202 timber frame consisting of top and bottom rail and side
styles of well seasoned timber 65mm wide each and the entire frame fitted with
27.5mm wide battens places both ways in order to made the door of solid core
and internal lipping with teak, mahogony or rose wood approved decorative veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing
the shutters in position but excluding the cost of hinges and other fittings in ground floor:
(a) 35mm thick shutters (single leaf
5.25
3955
20764
... More
(b) Supplying 'Godrej' mortice lock chromium plated with keys 6 levers including
fitting & fixing complete.
1
1954
1954
... More
Taking out shutter of door and window, dismantling by parts (for repair or replacement of damaged parts) , reassembling and refitting and rehanging same with old fittings but with new screws as necessary. (Where different parts of same shutter are renewed under different item, payment under item 73 will be
made once only).
5.04
126
635
... More
ii) Godrej Hydraulic door closer fitted and fixed complete.
(a) Heavy type
3
2064
6192
... More
(ii) Door stopper (Anodised aluminium)
3
70
210
... More
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. (vii) 100mm. X 58mm. X 1.90mm.
20
47
940
... More
Anodised aluminium barrel / tower / socket bolt (full covered) of approved
manufactured from extruded section conforming to I.S. 204/74 fitted and fixed
with cadmium plated screws:
(vi) 200mm long x 10mm dia. Bolt
10
78
780
... More
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. A) UPVC Pipes: (ii) 110 mm. Dia.
25
251
6275
... More
c) Bend 87.5 degree (ii) 110 mm. Dia.
5
140
700
... More
d) Shoe (ii) 110 mm. Dia.
5
111
555
... More
Add: SGST 9 % + CGST 9% = 18 %
1
246550
246550
... More
Labour Wellfare Cess 1%
1
16162
16163