Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Public Works Department - PWD Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date29 Oct 2024
Closing Date22 Nov 2024
Tender Amount₹ 7,22,142
Costs
EMD
₹ 14,443Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Wbpwd/ee/hed/nit- 190 Of 2024-2025
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WBPWD_765993_1Tender No
WBPWD/EE/HED/NIT- 190 of 2024-2025Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://wbpwd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Incomer:-
415V 250 Amp TPN SFU units with 03 nos DIN type HRC fuses in open exexution.---- 1 No.
-
-
-
Metering & Indication:- a) Digital Multifunction Meter - 01 No. b) 230V R.Y.B. LED indicator lamp ---- 3 nos.
c) 100/5 Amp ratio C.T (Kappa/Pragati/AE or equivalent make as approved by EIC) --- 3 nos.
d) S & F 6 Amp SPMCB---4 nos.
-
-
-
Busbar:-
415V, 315 Amp capacity 99.5% – 99.9% electrolytic tinned 4 bar copper bus bar [size of flat 4x40 mm x 5 mm ] of length 1.5 Mtr., mounted on non-hygroscopic FRP/SMC/DMC insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification - 1 set.
-
-
-
The busbar is to be rigidly supported on suitable non-hygroscopic insulating materials of robust ration to with stand electromechanical stress in the event of earth fault. All connection to bus to made by suitable nuts & bolts. The busbar is too wrapped with coloured PVC (Red. Yellow, Blue & Black) for colour identifications.
-
-
-
Outgoings:-
-
-
-
(i) 415V 200 Amps TPN SFU units with 03nos DIN type HRC fuses in open exexution.---- 2 No.
-
-
-
(i) 415V 63 Amps TPN SFU units with 03nos DIN type HRC fuses in open exexution.----2 No.
-
-
-
(i) 415V 32 Amps TPN SFU units with 03 nos DIN type HRC fuses in open exexution.---- 1 No.
-
-
-
Interconnection :-
All interconnection between incoming main to Busbar are to be made with suitable size electrolytic tinned copper bars or equivalent flexible pvc insulated multistranded single core Cu cable as directed by E.I.C and the same between busbar to each outgoing mains and & for metering arrangements are to be made by suitable size of Copper with proper socketing of the end of each wire leads.
-
-
-
Earthing :-
A separate continuous aluminum earth busbar of size 50mm x 6mm shall run across the full length of the panel board . All electrical equipment are to be properly earthed with suitable size G.I. wire.
-
-
-
The complete panel board is to be coated paint.
-
-
-
Installation :-
The complete panel board is to be installed on suitable brick padestal as directed by the E.I.C.
All incoming/outgoing switches is to be properly lebeled on Acrylic sheet as per direction of EIC. [NS]
-
-
-
Sub-RAW Panel
-
-
-
Supply and installation of L.T. cubical type fully compartmentalized distribution panel board, having rigid and self supporting structure fabricated with 14 SWG CRCA sheet with M.S. angle iron frame (40 x 40x6 mm MS angle iron). The base of panel should be made with 75mm x 40mm x 4.4 mm M.S. channel. [Manufacturer/Fabricator having Test Certificates from CPRI]. An Auto Cad Drawing of the panel has to approved by EIC before making of panel..(OEM Make:Legrand/L&T/ABB/Siemens)
1
49464
49464
Metering & Indication:- a) Digital Multifunction Meter - 01 No. b) 230V R.Y.B. LED indicator lamp ---- 3 nos.
c) 100/5 Amp ratio C.T (Kappa/Pragati/AE or equivalent make as approved by EIC) --- 3 nos.
d) S & F 6 Amp SPMCB---4 nos.
-
-
-
Busbar:-
415V, 250 Amp capacity 99.5% – 99.9% electrolytic tinned 4 bar copper bus bar [size of flat 4x25 mm x 6 mm ] of length 1.5 Mtr., mounted on non-hygroscopic FRP/SMC/DMC insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification - 1 set.
-
-
-
The busbar is to be rigidly supported on suitable non-hygroscopic insulating materials of robust ration to with stand electromechanical stress in the event of earth fault. All connection to bus to made by suitable nuts & bolts. The busbar is too wrapped with coloured PVC (Red. Yellow, Blue & Black) for colour identifications.
-
-
-
Outgoings:-
-
-
-
(i) 415 V, 40-63A FP MCB of Breaking capacity 10kA & C characteristics on din rail ---- 10 Nos.
-
-
-
Interconnection :-
All interconnection between incoming main to Busbar are to be made with suitable size electrolytic tinned copper bars or equivalent flexible pvc insulated multistranded single core Cu cable as directed by E.I.C and the same between busbar to each outgoing mains and & for metering arrangements are to be made by suitable size of Copper with proper socketing of the end of each wire leads.
-
-
-
Earthing :-
A separate continuous aluminum earth busbar of size 50mm x 6mm shall run across the full length of the panel board . All electrical equipment are to be properly earthed with suitable size G.I. wire.
-
-
-
The complete panel board is to be powder coated painted.
-
-
-
Installation :-
The complete panel board is to be installed on wall by grouted suitable iron fram made by 50x50x5mm MS Angle & Flat as directed by the E.I.C.
All incoming/outgoing switches is to be properly lebeled on Acrylic sheet as per direction of EIC.[NS]
-
-
-
Emergency Panel
-
-
-
Supply and installation of L.T. cubical type fully compartmentalized distribution panel board, having rigid and self supporting structure fabricated with 14 SWG CRCA sheet with M.S. angle iron frame (main frame with 50 x 50 x 6 mm angle and each vertical compartment with 40 x 40x6 mm MS angle iron). The base of panel should be made with 75mm x 40mm x 4.4 mm M.S. channel. [Manufacturer/Fabricator having Test Certificates from CPRI]. An Auto Cad Drawing of the panel has to approved by EIC before making of panel..(OEM Make:Legrand/L&^T/ABB/Siemens)
1
51818
51818
Incomer:-
415 V, 125A Four Pole MCCB of Breaking capacity 25kA/35kA on din rail in open exexution.---- 1 No.
-
-
-
Metering & Indication:- a) Digital Multifunction Meter - 01 No. b) 230V R.Y.B. LED indicator lamp ---- 3 nos.
c) 100/5 Amp ratio C.T (Kappa/Pragati/AE or equivalent make as approved by EIC) --- 3 nos.
d) S & F 6 Amp SPMCB---4 nos.
-
-
-
Busbar:-
415V, 250 Amp capacity 99.5% – 99.9% electrolytic tinned 4 bar copper bus bar [size of flat 4x25 mm x 6 mm ] of length 1.5 Mtr., mounted on non-hygroscopic FRP/SMC/DMC insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification - 1 set.
-
-
-
The busbar is to be rigidly supported on suitable non-hygroscopic insulating materials of robust ration to with stand electromechanical stress in the event of earth fault. All connection to bus to made by suitable nuts & bolts. The busbar is too wrapped with coloured PVC (Red. Yellow, Blue & Black) for colour identifications.
-
-
-
Outgoings:-
-
-
-
(i) 415 V, 40-63A FP MCB of Breaking capacity 10kA & C characteristics on din rail in open exexution.---- 10 Nos.
-
-
-
Interconnection :-
All interconnection between incoming main to Busbar are to be made with suitable size electrolytic tinned copper bars or equivalent flexible pvc insulated multistranded single core Cu cable as directed by E.I.C and the same between busbar to each outgoing mains and & for metering arrangements are to be made by suitable size of Copper with proper socketing of the end of each wire leads.
-
-
-
Earthing :-
A separate continuous aluminum earth busbar of size 50mm x 6mm shall run across the full length of the panel board . All electrical equipment are to be properly earthed with suitable size G.I. wire.
-
-
-
The complete panel board is to be spray painted after required surface treatment by 9 tanks process / sand blasting with 2 coat of red oxide primer & 2 coat of finished paint over dried or powder coating.
-
-
-
Installation :-
The complete panel board is to be powder coating painted.[NS]
-
-
-
Supplying and fixing of 415V,125A on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc (L&T) (For Generator Panel) [D-2/3a]
1
8739
8739
Supplying and fixing 415V, 100A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.(Make:L&T) (For BPHU Building) [D-3/4a]
1
6449
6449
Supplying & fixing 415 V, 100/125 A sheet metal (16 SWG) Iron Clad Cu Busbar chambers of 4 x 15x3mm on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991)(For BPHU Building)[D-12/19(b)]
1
2701
2701
Supply & Delivery of 1.1 KV XLPE Insulated & Sheathed Armoured Aluminium power cables [ Make Gloster /Polycab /Havells/Mescab/Finolex/RR Kabel] as per choice of EIC. [NS]
-
-
-
i) 4 Core 95 Sq. mm [from Kiosk room to Main Panel ]
15
698
10470
ii) 4 Core 70 Sq. mm [from LT main panel to Hospital IPD panel below stair case existing 200A main swich]
110
551
60610
iii) 2 Core 6 Sq. mm [from BPHU building to store and group D quarter ms]
230
104
23920
iv) 4 Core 35 Sq. mm [from BPHU building to doctor quarter ms]
85
313
26605
v) 4 Core 16 Sq. mm
80
194
15520
Laying of cable upto 2 core 6 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting. [F-1/2a]
10
58
580
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting. [F-1/2b]
80
61
4880
Laying of cable above 4 core 35 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. As necy., mending good damages and painting.[F-1/2d]
25
85
2125
Laying of cable 4 Core 70 Sq. mm, on existing Cable Tray and binding with suitable size GI wire.[F-3/6ii]
110
15
1650
Laying of one No. cable 2 core 6 sqmm & 4 core 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.[F-2/1a]
280
168
47040
Supplying & fixing 40 mm dia medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. [F-6/11c]
10
251
2510
Supply & Delivery of 1.1 KV Aluminium Aerial Bunched cable [ Make Gloster /Polycab /Havells/Mescab/Finolex/RR Kabel] as per choice of EIC. [NS]
-
-
-
3c x 50 +1c x16 +1cx35(bare conductor)
105
201
21123.9
Supplying and fixing compression type gland complete with brass
gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE /PVC armoured cables as below :[F-4/7]
-
-
-
i) 4 Core 95 Sq. mm
2
239
478
ii) 4 Core 70 Sq. mm
4
216
864
iii) 2 Core 6 Sq. mm
8
69
552
iv) 4 Core 35 Sq. mm
4
165
660
v) 4 Core 16 Sq. mm (existing cable)
40
135
5400
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials .[F-5/8]
-
-
-
i) 4 Core 95 Sq. mm
2
316
632
ii) 4 Core 70 Sq. mm
4
268
1072
iii) 2 Core 6 Sq. mm
8
33
264
iv) 4 Core 35 Sq. mm
4
161
644
v) 4 Core 16 Sq. mm
40
97
3880
vi) 3c x 50 +1c x16 +1cx35
2
213
426
Supply & Delivery of 9 Mtr. Steel Tubular Pole (Zindal/Bansal/Subham) as per specification Type 410-SP-28 as overall length 9 mtr. (Bottom- 5 mtr., Middle & Top- 2 mtr. long), weight 113 kg. & having diamentions are- Out side dia & thickness of the Bottom section ( 139.7x4.50) mm; Middle section (114.3x3.65) mm, Top Section (88.9x3.25) mm with fixing the base plate and GI earth bolt after making drilled holes etc. on pole as per direction of EIC.[NS]
3
8313
24939
Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly [H-1/1(a)]
-
-
-
Upto 9.0 mtr. Size 0.6x0.6x1.70 mts
3
2892
8676
Extra on items above, for providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, as per GS .[3 (b)(i)/ H- 1 ]
3
1060
3180
Painting of Steel Tubular Pole of following lengths and 2 nos. of aluminium coats of paint over 1 coat of RO priming with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint
-
-
-
Upto 9 mtr. long pole
3
336
1008
Supply of MS Channel of dimension, h=100 mm,b=50 mm,t=8.5 mm 7 s=6 mm @ 7.13 kg/mtr, for horizontal arm on pole incl making holes for bolting as required. [7 (a)(i)/ H- 2 ]
-
-
-
Each of length-0.8 mtr
3
600
1800
Supply of MS Channel of dimension, h=100 mm,b=50 mm,t=8.5 mm 7 s=6 mm @ 7.13 kg/mtr, for vertical support of AB cable at substation building wall.[NS]
-
-
-
Each of length-3.0 mtr ( 1 mtr to be fixed on wall & 2 mtr will be above roof) [NS]
1
1977
1977
Supply of Galv Iron dead end clamp bracket. [NS]
18
450
8100
Suspension clamp for hanging AB Cable from pole. [NS]
18
450
8100
Supply of 7/10 stranded GI conductor as catennary wire from pole to pole incl binding materials as required.[@ 0.486 Kg/mtr] [NS]
105
37
3885
Supply & fixing of 40 mm x 40 mm x6 mm MS "L" shaped angle bracket of length 0.75 mtr with bi-farketed legs for grouting in the wall incl grouting of MS angles with cement morter,labour etc as required.(for laying of cables inside of the building.[NS]
1
175
175
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support.With 25x25x3mm angle iron support[D-14/34-a-ii]
-
-
-
200x50x1.25mm (18SWG)
110
293
32230
Supply & Fixing of perforated GI cable tray bend with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. [D-15/34(b)]
-
-
-
200x50x1.25mm (18SWG)
4
458
1832
Supplying and fixing Sheet steel Main Switches on flat iron frame on wall 240V DP with fuse on L&N .(For store and kitchen) [D-1/1a]
4
588
2352
Supplying & Fixing MS looping cable box size 250x150x100 mm deep having 4 mm thick comprising of 4 x 25x5mm alluminium bars., earthing terminal with lug, on angle iron frame on wall, incl. earthing attachment and painting as required. [D-12/19a]
0.5
2532
1266
Supply and fixing of MS Angle iron frame(50mmX50mmX3mm )ladder for carrying the cable of 35 sq mm in overhead from one building to another building(BPHU to Doctor quarter) by grouting the frame in wall.(approx length 4 mtr & 2.3kg /m) [84 of 96 of 3rd CORRIGENDA & ADDENDA FOR SCHEDULE OF RATES OF PWD (W.B) wef 01.11.2017]
0.1
72603
7260.3
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint. [F-5/5]
10
467
4670
Excavation of soil for installation of Earth Electrode and filling & ramming.[G-1/1a]
-
-
-
For Soft Soil
20
219
4380
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: [G-1/2a]
-
-
-
By ISI-Medium GI pipe
10
1396
13960
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.[G-2/4a]
1
159
159
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.[G-2/5a]
-
-
-
No. 10 SWG
92
6
552
Supply & Delivery 240 Volt, 50Hz, 4 ft long, Max 20 Watt, efficacy-100lm/w, PC body, Al housing Single LED Tube Light fittings complete with all accessories including LED Tube. [Make: Philips/Crompton/Wipro or Manufacturer with own NABL accredited lab with valid test certificate] as per direction of EIC.
16
491
7856
Supply & Delivery of 240 Volt, 50Hz 65W 200CMM 400RPM 1200mm (48”) sweep ac ceiling fan, BEE star rated (Make –Crompton, Orient, Polar) as per direction of EIC.
10
1678
16780
Add GSt @ 18 %
1
109066
109066.56
Add LWC @ 1%
1
7149
7149.92
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%