Public Works Department Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Public Works Department - PWD Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date27 Dec 2023
Closing Date15 Jan 2024
Tender AmountRefer Documents
Costs
EMD
₹ 40,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_WBPWD_632271_1Bid Award Id
ViewTender No
WBPWD/EE-I/KSHED/Q62/23-24(2nd Call)Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://wbpwd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Average run 10 mtr
124
-
-
Average run 12 mtr
85
-
-
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Make - Legrand Myrius/Arteor L&T - Entice/Englaze, Schneider - Unica Pure), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
54
-
-
Supply & Fixing 240 V, 2 x 6 A, Modular type plug socket with separate 2 x 6 A Modular type switch (Make - Legrand Myrius/Arteor L&T - Entice/Englaze, Schneider - Unica Pure) on 6 Module switch board having 6 Module top cover plate flushed in wall incl. making necy. connections with PVC Cu wire and earth continuity wire etc.
30
-
-
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Make - Legrand Myrius/Arteor L&T - Entice/Englaze, Schneider - Unica Pure) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
77
-
-
Taking out the existing timer DB for AC & refixing thr same incl. Interconnection after civil renovation works as per direction of EIC
16
-
-
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles - 19 mm dia 3 mm thick polythene pipe without earth continuity wire
1808
-
-
Supplying and Drawing 1.1 KV single core stranded 'FRLSH' PVC insulated & unsheathed single core stranded copper wire (Finolex/Havells/Gloster/Polycab) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required
-
-
-
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC for sep.
1310
-
-
2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
300
-
-
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC
170
-
-
Distribution wiring in 1.1 KV single core stranded 'FRLSH' PVC insulated & unsheathed copper wire (Finolex/Havells/Gloster/Polycab) in 25mm size PVC rigid conduit 'FR' (Precision/Polycab make) incl. necy. fittings as required for 3-ph Tower A.C
-
-
-
4 x 56/0.3 (4 sqmm) + 2 x 36/0.3 (2.5 sqmm) ECC
198
-
-
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
-
-
-
6 way Enclosure (Legrand) (607716)
2
-
-
4 way Enclosure (Legrand) (607716)
4
-
-
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. Legrand FP 63 A
6
-
-
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection
-
-
-
6-32 A SP (Legrand)
60
-
-
16/32 A FP (Legrand)
8
-
-
Supply of 18 W or 20 W LED tubelight having polycarbonate body (Philips MAS LED 18 W PC body/Wipro/Osram)
40
-
-
Supply & laying of 1.1 kV gr XLPE Armoured Alu cable 4 core 25 sqmm (Havells/KEI/Polycab) on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting (Panel to VTPN)
228
-
-
Supply & laying of 1.1 kV gr XLPE Armoured Alu cable 4 core 25 sqmm (Havells/Gloster/Polycab) on existing cable tray incl. mending good damages and painting (Panel to VTPN)
98
-
-
Supply & laying of 1.1 kV gr XLPE Armoured Alu cable 4 core 16 sqmm (Havells/Gloster/Polycab) on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting (VTPN to Power DB)
185
-
-
Supply & laying of 1.1 kV gr XLPE Armoured Alu cable 2 core 6 sqmm (Havells/Gloster/Polycab) on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting (Compound lighting)
75
-
-
Distribution wiring in 1.1 KV single core stranded 'FRLSH' PVC insulated & unsheathed copper wire (Finolex/Havells/Gloster/Polycab) in 25mm size PVC rigid conduit 'FR' (Precision/Polycab make) incl. necy. fittings as required (power DB to SPN DB)
-
-
-
2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC
353
-
-
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. 200x50x1.25mm (18SWG) With 25x25x3mm angle iron support
98
-
-
Fixing only exhaust fan by suitable fastner incl. providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 30 cm (12")
10
-
-
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Make - Legrand Myrius/Arteor L&T - Entice/Englaze, Schneider - Unica Pure) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
40
-
-
Supply & Fixing Socket type fan regulator (Step type) (Anchor) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
100
-
-
Supply & Fixing 1200 mm sweep AC Ceiling Fan (Crompton HS+ / Orient Summercool) with all accessories & engraving & painting the Departmental Number upto 15 digit on fan body & making necessary interconnection as required with 2.5 MFD burstproof P2/S2 type capacitor (EPCOS/Tibcon/Universal)
28
-
-
Engraving the deptt. number with 10 mm lettering on the body of fan upto 10 letters incl. hifen, stroke or stop
30
-
-
Extra for additional one letter incl. hifen, stroke and stop
100
-
-
Painting upto 10 letters of the engraved number with approved black /red paint as required
30
-
-
Extra painting for additional one letter of the engraved number with hifen, stroke etc. with black or red paint
100
-
-
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
-
-
-
4 core 25 sq mm
10
-
-
4 core 16 sq mm
16
-
-
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
-
-
-
4 core 25 sq mm
10
-
-
4 core 16 sq mm
16
-
-
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
-
-
-
2.5sqmm
676
-
-
4 sqmm
114
-
-
6 sqmm
100
-
-
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe
4
-
-
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. As required
1
-
-
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages - No. 6 SWG
30
-
-
Supply & Installation of 5/8" & 1/4" copper pipes, insulation tape etc for above AC machine as per direction of EIC
120
-
-
Supply & Filing of R-32/R - 410 A refrigerant
30
-
-
Supply & Installation L type of Heavy Duty split AC stand for outdoor unit (Mounting bracket) size 40 cm x 40 cm x 5 cm with suitable fasteners on wall as per direction of EIC
15
-
-
Supply & fixing of 3 core 2.5 sq mm unarmoured copper cable (Make - Gloster/RR Kabel/Havells)
180
-
-
Testing, checking, cleaning & overhauling of split AC machine as per direction of EIC
16
-
-
Installation Charge for AC machine both indoor & outdoor unit & mending good damages
16
-
-
Refixing the street light fittings on wall incl. Interconnection as per direction of EIC
3
-
-
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint
3
-
-
Supply & Laying of cable 1.1 KV Gr. 2 core 6 sqmm Al/Ar Cable (Gloster/Havells/Polycab) in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
106
-
-
Supply and Fixing SMC Junction Boxes of dimention (250x200x105) mm with IP 67 protection (Sintex)make for compound light. With 4 pole terminal stud and 6A 10KA C curve SP MCB Legrand make - Mounted directly on pole by MS clamp
12
-
-
S/F post top lantern [Make - crompton Model No: Heritage LPTH-20-CDL or Philips/Bajaj having similar specifications] having IP 65 protection to be fixed directly on pole incl. Interconnection as to GS.
12
-
-
Supply of 1420 RPM, 300 mm sweep exhaust fan full metal body with blades, motor unit, p2 type capacitor complete [make - EPC]
11
-
-
Defect Liabibility Period 1 (One) year
-
-
-
Make & model of each and every material to be approved by EIC
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements