Public Works Department Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Public Works Department - PWD Tender

Works
Security and Emergency Services
Eprocure
Opening Date14 Dec 2023
Closing Date31 Jan 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
SITC of addressable aspirating smoke detector (ASD) EN54 standard & VDS/UL approved having dual-wavelength technology to trigger an alarm at the earliest possible moment, designed to protect small and mediumsized business-critical environments for monitoring areas of min 800 m2, USB interface to configure the detector,display that contains clear, comprehensible bar graphs for smoke and airflow, as well as an alarm indicator, an error indicator, and a dust indicator, operating temperature -20...+60 °C, Minimum pipe length - Single/Dual 100 mtr. with min 1000 event memories and IP30 rating. (Approved make : Siemens/Honeywell/ Extralis / Securiton/Carrier) NB.1) Agency Should visit the site before participation 2.) As per design based on room the calculation agency should provide suitable capacity panel

5

-

-

... More
SITC of standalone power supply to external devices and components as per EN 54-4 and VDS/UL with operating and fault indicator, shown via a green and a yellow LED with potential-free relay contacts for fault messages, additional installation of an I/O module possible, uninterruptible power supply with battery charging and batteries / integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 60 minutes during Emergency condition, with integral battery charger complete in all respect as required. (Approved make : Siemens/Honeywell/ Extralis / Securiton/Carrier)

14

-

-

... More
SITC of air intake pipe, exhaust UPVC pipe having Outer Ø 25 mm & Inner Ø 21 mm with fabricated ASD holes with sampling tube for air suction with mecessary joints, tee and clamps and necessary civil works if required.

1500

-

-

... More
SITC of IP Addressable Manual call point ( VDS, EN,UL & FM approved ) with in built short circuit fault isolator as per NFPA style 7 wiring. (Approved make : Siemens/Honeywell/ Extralis / Securiton/Carrier)

14

-

-

... More
SITC of Addressable Hooter-cum-Strobe ( VDS, EN,UL & FM approved ) (sound output of minimum 90 db) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. (Approved make : Siemens/Honeywell/ Extralis / Securiton/Carrier)

14

-

-

... More
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make : Finolex / Havells / RR Kabel /Gloster/ Polycab/KEI) with 20mm NB PVC 'FR' rigid conduit pipe (Red Colour) on the surface of the wall. (Make : Polycab/Presto/AKG/Precision-Medium).

1000

-

-

... More
Supply & Fixing 240 V, 3 nos. 20A plug socket with separate 3 nos. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 300x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required .(E-8 / 30)

1

-

-

... More
SITC of Microprocessor based addressable fully networkable,expandable fire alarm control panel ( VDS, EN with UL & FM approved ) suitable for the devices as stated in thefollowing items of this BOQ along with 20% spare capacity with each loop loading not exceeding 80% of the full capacity of detectors and devices taken together, complying to IS 2189:2008 or its latest amendments, and with VGA display.Thc panel shall be soft addressable type and shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches with help monitor module whenever any alarm is triggered. The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards. The panel should have extra loop card slot for expansion of capcity twice.

-

-

-

... More
The panel shall have in built rectifier, provision for external & internal printer ( if required ), Loop cards, LCD unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 60 minutes during Emergency condition, with integral battery charger complete in all respect as required.

-

-

-

... More
The FACP shall be capable of being networked ( future expansion ) with other similar FACP located at different part of the premises through single RS 485 modbus. The FACP shall have provision for interfacing with the public address system, remote computer and BMS interface.The system must be preloaded with licenced software. (Approved make : Siemens/Honeywell/ Extralis / Securiton/Carrier)

1

-

-

... More
N.B. i) The DLP period is of 12 Months from the date of Final bill.

-

-

-

... More
ii) Rates should be quoted with minor Civil works. Wall cutting and mending good the damages to the original finish.

-

-

-

... More
Terms and Conditions i) The Agency must procure the materials from the Manufacturer / OEM or from their authorise sales channel so that the standard warranty / Supportof of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. ii) Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution of work /submission of bill iii) If any refurbished material is supplied and installed penal action will be taken as per existing rules.

-

-

-

... More
[ Rates should be Quotated inclusive of all taxes & duities applicable as per Govt. rules & regulations]

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.