Public Works Department Tender

... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Public Works Department - PWD Tender

Works
Electrical and Electronics
Eprocure
Opening Date19 Feb 2025
Closing Date10 Mar 2025
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
No. of phase: Three Phase

-

-

-

... More
Rated capacity of Engine: minimum 80.2 BHP

-

-

-

... More
Rated Engine power: 100 % of the required powered at STP(Standard Temperature Pressure) i.e. equal to (Nominal Rated Capacity (KVA) of power generator + Any Auxilary power Consumption by the Power generator) x Power factor(0.8) /Alternator efficiency

-

-

-

... More
Type of engine cooling: Liquid cooled

-

-

-

... More
Type of Governor : Electronic

-

-

-

... More
No. of Cylinders: 4

-

-

-

... More
No. of Strokes: 4

-

-

-

... More
Rated RPM of Engine:1500

-

-

-

... More
Fuel Type : High Speed Diesel(HSD)

-

-

-

... More
Over load capacity: Engine is capable of delivering an output of 10% in excess of rated KVA for a period of one hour in any period of 12 hours continous running.

-

-

-

... More
Specific fuel consumption: 8.772 L/H

-

-

-

... More
Starting voltage: 12V

-

-

-

... More
Salient futures of engine: Turbo charged Engine, Direct injection Fuel System.

-

-

-

... More
GOVERNING CLASS

-

-

-

... More
Class of Governor : A2 or better

-

-

-

... More
Maximum Change of Speed as a Percentage of Rated Speed on suddenly taking-off the rated load (Transient) : 15

-

-

-

... More
Maximum Recovery Time in Seconds on suddenly taking-off the rated load(Transient) : 15 second

-

-

-

... More
Maximum Change of Speed as a Percentage of Rated Speed on suddenly taking-off the rated load (Permanent): 5

-

-

-

... More
Maximum Change of Speed as a Percentage of Rated Speed On a change of load, both on and off , by all steps of 25 percent of the rated load (Transient): 4

-

-

-

... More
Maximum RecoveryTime in Seconds on a change of load, both on and off , by all steps of 25 percent of the rated load (Transient) : 5 second

-

-

-

... More
Maximum Change of Speed as a Percentageof Rated Speed On a change of load, both on and off , by all steps of 25 percent of the rated load (Permanent): 1.5

-

-

-

... More
ALTERNATOR Make: Koel Green/Stamford/Leroy Somer/ Crompton Greaves/ABB/Alstom.

-

-

-

... More
Rating of AC generator : 50 KVA

-

-

-

... More
Alternator Voltage Rating : 415V

-

-

-

... More
Rated Power Factor : 0.8

-

-

-

... More
Efficiency at rated power factor at 75% of full load: 90.2 percent

-

-

-

... More
The alternator should conform to IS 13364(part 2) or any latest standard

-

-

-

... More
Type of Alternator : Brushless

-

-

-

... More
Voltage regulation : VG 3

-

-

-

... More
Class of Protection : IP 23

-

-

-

... More
Class of Insulation: H

-

-

-

... More
CONTROL PANEL

-

-

-

... More
Type: AMF Control Panel

-

-

-

... More
Location: Inside the canopy.

-

-

-

... More
IP Rating of control panel: IP-53

-

-

-

... More
Display meters in the control panel: Multifunctional Digital Display meter(displaying voltage,current,Frequency,power factor)

-

-

-

... More
Displayed Parameters Features: Control panel shall have displayed parameters of Engine Speed, Lube oil pressure, Coolant/cylinder head Temperature,Engine running hours, Engine battery voltage, Engine Running status, Generator Voltage (Ph-Ph),Generator Voltage (Ph-N), Generator apparent Power(kVA), Generator active Power(kW), Power factor, Frequency, Fuel level, Event log, Control supply Voltage.

-

-

-

... More
Other Devices in the control panel: Required switches and cutout, MCB, Battery charger of appropriate rating shall be provided in the control panel.

-

-

-

... More
Indicators: Low lub oil pressure, High water/coolant/Cylinder head temperature, low fuel level, over speed.

-

-

-

... More
ACOUSTIC ENCLOSURE

-

-

-

... More
Acoustic Enclosure: Inclusive in the scope of supply

-

-

-

... More
Sheet Thickness:1.6 mm

-

-

-

... More
Thickness of Insulatin: 40mm

-

-

-

... More
Density of insulation: Minimum 32 kg/cubic mtr

-

-

-

... More
Noise Level : 75dB

-

-

-

... More
FUEL TANK

-

-

-

... More
Fuel Tank capacity : Minimum 150 Ltrs.

-

-

-

... More
Number of Fuel Tank: 01

-

-

-

... More
Fuel Tank Sheet Material Thickness: 2 mm

-

-

-

... More
Fuel Tank Fabricated Material : MS sheet

-

-

-

... More
Fuel Tank Features: Fuel Tank capacity is sufficient for 8 hrs of running at full load

-

-

-

... More
BATTERY

-

-

-

... More
Battery Type & specification: low maintenance free to IS:14257 for high cranking performance Battery shall be provided .

-

-

-

... More
Number of Batteries: 01

-

-

-

... More
Battery Capacity (AH): 90AH

-

-

-

... More
Salient Feature of power generator: Glass window on Acoustic enclosure in front of the control, Emergency stop outside the Acoustic Enclosure.

-

-

-

... More
TRAILER: Not Applicable

-

-

-

... More
General Technical Requirements (GTR)

-

-

-

... More
Power Generator shall be complete with Diesel Engine, Alternator and AMF Control Panel along with Acoustic Enclosure. Diesel engine and alternator shall be closely coupled or provided with flexible coupling and mounted on a base plate / M.S. frame of robust in construction.

-

-

-

... More
Anti-Vibration mountings shall be provided for complete Power Generator in case of flexible couplinIg. In case of direct coupling Anti-Vibration mountings shall be provided for the Engine as well as the alternator.

-

-

-

... More
Power Generator should have protection against under voltage, over voltage, under frequency, over frequency, low battery voltage, over current, earth-fault, short circuit, phase sequence change etc.

-

-

-

... More
Automatic Mains Failure (AMF) control panel, shall be able to start up the Power Generator and transfer the load on to the Power Generator on mains failure without requiring any human intervention. Similarly on restoration of mains supply, it shall be able to transfer the load to mains supply and switch off the Power Generator automatically

-

-

-

... More
Control Panel , shall be equipped with suitableVoltmeter, Ammeter, Frequency meter, power factor meter (these items can be alternatively supplied in one multifunctional digital display meter), battery charger, indicators, various switches and cutout / MCB / MCCB / Contactor / Circuit breaker for the DG output of appropriate rating and accuracy class as per trade practice for better utility.

-

-

-

... More
Acoustic Enclosure shall be made of Pre-treated and Powder coated CRCA Sheet. The sheet shall be Pre-treated and Powder coated with weather-proof paint. The Acoustic Enclosure shall be vermin proof. The enclosure shall accommodate the fuel tank of the Power Generator to make the system compact.

-

-

-

... More
Power Generators shall meet the requirements of Environmental (Protection) Rules 1986 as laid down by Ministry of Environment & Forests read with GSR 371 (E) dated 17.5.2002,GSR520(E) dated 1.7.2003 , No.448 (E)dated 12.07.2004 , GSR 771(E) dated 11.12.2013 GSR232(E)dated 31.03.2014, Gazette Notification No.167 dated. 31.03.2014 and Gazette Notification No. 578 dated. 11.11.2014 in respect of noise and emission norms. The latest amendments to above GSRs shall be applicable as amended by Ministry of Environment and Forest.

-

-

-

... More
Standard set of Supply, Installation, Commissioning & Testing of 50 kVA, 3 Phase Diesel Generator Set with AMF Control Panel and its connected accessories at HVF Estate as per Technical Specifications- Qty- 1 No.s consisting of a set of 3 spanners, one screw driver, one standard plier and one nose plier of appropriate size shall be provided along with each Power Generator.

-

-

-

... More
Supply of Fuel tank of suitable capacity, sufficient for minimum 8 hours running the Power Generator, is inclusive in the scope of supply. Fuel Tank shall be complete with fuel piping (between fuel tank and diesel engine), valves, level indications and all standard accessories. MS pipes, heavy class of suitable dia conforming to IS 1239 (Part-1) - latest shall be used for fuel piping.

-

-

-

... More
Scope of Installation

-

-

-

... More
Installation: With Installation inclusive in the scope of supply

-

-

-

... More
Installation of Power Generators shall be done by the seller. The installation work of Power Generator and its constituent parts shall be generally conforming to CPWD General Specifi cation for Electrical Works, Part - VII - latest. b) Foundation shall be constructed by the seller. Foundation shall be of PCC type with the ratio of 4:2:1. The length and breadth of the foundation shall be 300mm more from the respective length and breadth of the Power Generator. The height of the foundation shall be 400 mm, i.e., 200 mm below and 200 mm above the ground level. All the materials / labour required for foundation work shall be supplied by the seller.

-

-

-

... More
Supply, laying and termination of inter connecting power and control cable shall be done by the seller. The cable supplied shall be ISI marked heavy duty PVC insulated, armoured cable, with PVC outer Sheath , with aluminium conductor having insulation of PVC compound type -C, suitable for rated voltage upto and including 1100 volts and conforming to IS: 1554 (Part-1) latest. Total length of the cable supplied by the seller shall be 60 metres of minimum 3.5CX70 sqmm for each Power Generator.

-

-

-

... More
Construction of suitable earthing station and necessary connections shall be done by the seller. All the materials / labour required for construction of earthing station shall be supplied by the seller. The total number of earthing pits/stations shall be 4, i.e., 2 for neutral and 2 for body- earthing for each generator. Neutral earthing shall be done with copper Plate and Body earthing shall be done with G.I. plate / Copper. The consignee should choose installation site in such a way that the earthing stations can be made within 10 metres of the Power Generator. Earthing station shall be typically constructed as per prevalent standard practices and shall be generally conforming to CPWD General specification for Electrical Works.Installation of fuel tank including foundation/stand shall be done by the seller.

-

-

-

... More
Supply & delivery of 100 Ltr of Diesel for testing and commissioning purpose.

-

-

-

... More
DG SET 2 - Supply, Installation, Commissioning & Testing of 30 kVA, 3 Phase Diesel Generator Set with AMF Control Panel ,CPCB-IV+ Approved engine and its connected accessories at HVF Estate as per Technical Specifications-

1

-

-

... More
DIESEL ENGINE Make: Cummins/Mahindra/Koel Green/Greaves/Volvo/Parkins/ Ashok Layland/Eicher.

-

-

-

... More
Rated Capacity in KVA : 30 KVA

-

-

-

... More
No. of phase: Three Phase

-

-

-

... More
Rated capacity of Engine: minimum 42 BHP

-

-

-

... More
Rated Engine power: 100 % of the required powered at STP(Standard Temperature Pressure) i.e. equal to (Nominal Rated Capacity (KVA) of power generator + Any Auxilary power Consumption by the Power generator) x Power factor(0.8) /Alternator efficiency

-

-

-

... More
Type of engine cooling: Liquid cooled

-

-

-

... More
Type of Governor : Electronic

-

-

-

... More
No. of Cylinders: 4

-

-

-

... More
No. of Strokes: 4

-

-

-

... More
Rated RPM of Engine:1500

-

-

-

... More
Fuel Type : High Speed Diesel(HSD)

-

-

-

... More
Over load capacity: Engine is capable of delivering an output of 10% in excess of rated KVA for a period of one hour in any period of 12 hours continous running.

-

-

-

... More
Specific fuel consumption: 6.9 l/h

-

-

-

... More
Starting voltage: 12V

-

-

-

... More
Salient futures of engine: Turbo charged Engine, Direct injection Fuel System.

-

-

-

... More
GOVERNING CLASS

-

-

-

... More
Class of Governor : A2 or better

-

-

-

... More
Maximum Change of Speed as a Percentage of Rated Speed on suddenly taking-off the rated load (Transient) : 15

-

-

-

... More
Maximum Recovery Time in Seconds on suddenly taking-off the rated load(Transient) : 15 second

-

-

-

... More
Maximum Change of Speed as a Percentage of Rated Speed on suddenly taking-off the rated load (Permanent): 5

-

-

-

... More
Maximum Change of Speed as a Percentage of Rated Speed On a change of load, both on and off , by all steps of 25 percent of the rated load (Transient): 4

-

-

-

... More
Maximum RecoveryTime in Seconds on a change of load, both on and off , by all steps of 25 percent of the rated load (Transient) : 5 second

-

-

-

... More
Maximum Change of Speed as a Percentageof Rated Speed On a change of load, both on and off , by all steps of 25 percent of the rated load (Permanent): 1.5

-

-

-

... More
ALTERNATOR Make: Koel Green/Stamford/Leroy Somer/ Crompton Greaves/ABB/Alstom.

-

-

-

... More
Rating of AC generator : 30 KVA

-

-

-

... More
Alternator Voltage Rating : 415V

-

-

-

... More
Rated Power Factor : 0.8

-

-

-

... More
Efficiency at rated power factor at 75% of full load: 90.2 percent

-

-

-

... More
The alternator should conform to IS 13364(part 2) or any latest standard

-

-

-

... More
Type of Alternator : Brushless

-

-

-

... More
Voltage regulation : VG 3

-

-

-

... More
Class of Protection : IP 23

-

-

-

... More
Class of Insulation: H

-

-

-

... More
CONTROL PANEL

-

-

-

... More
Type: AMF Control Panel

-

-

-

... More
Location: Inside the canopy.

-

-

-

... More
IP Rating of control panel: IP-53

-

-

-

... More
Display meters in the control panel: Multifunctional Digital Display meter(displaying voltage,current,Frequency,power factor)

-

-

-

... More
Displayed Parameters Features: Control panel shall have displayed parameters of Engine Speed, Lube oil pressure, Coolant/cylinder head Temperature,Engine running hours, Engine battery voltage, Engine Running status, Generator Voltage (Ph-Ph),Generator Voltage (Ph-N), Generator apparent Power(kVA), Generator active Power(kW), Power factor, Frequency, Fuel level, Event log, Control supply Voltage.

-

-

-

... More
Other Devices in the control panel: Required switches and cutout, MCB, Battery charger of appropriate rating shall be provided in the control panel.

-

-

-

... More
Indicators: Low lub oil pressure, High water/coolant/Cylinder head temperature, low fuel level, over speed.

-

-

-

... More
ACOUSTIC ENCLOSURE

-

-

-

... More
Acoustic Enclosure: Inclusive in the scope of supply

-

-

-

... More
Sheet Thickness:1.6 mm

-

-

-

... More
Thickness of Insulatin: 40mm

-

-

-

... More
Density of insulation: Minimum 32 kg/cubic mtr

-

-

-

... More
Noise Level : 75dB

-

-

-

... More
FUEL TANK

-

-

-

... More
Fuel Tank capacity : Minimum 75 Ltrs.

-

-

-

... More
Number of Fuel Tank: 01

-

-

-

... More
Fuel Tank Sheet Material Thickness: 2 mm

-

-

-

... More
Fuel Tank Fabricated Material : MS sheet

-

-

-

... More
Fuel Tank Features: Fuel Tank capacity is sufficient for 8 hrs of running at full load

-

-

-

... More
BATTERY

-

-

-

... More
Battery Type & specification: low maintenance free to IS:14257 for high cranking performance Battery shall be provided .

-

-

-

... More
Number of Batteries: 01

-

-

-

... More
Battery Capacity (AH): 90AH

-

-

-

... More
Salient Feature of power generator: Glass window on Acoustic enclosure in front of the control, Emergency stop outside the Acoustic Enclosure.

-

-

-

... More
TRAILER: Not Applicable

-

-

-

... More
General Technical Requirements (GTR)

-

-

-

... More
Power Generator shall be complete with Diesel Engine, Alternator and AMF Control Panel along with Acoustic Enclosure. Diesel engine and alternator shall be closely coupled or provided with flexible coupling and mounted on a base plate / M.S. frame of robust in construction.

-

-

-

... More
Anti-Vibration mountings shall be provided for complete Power Generator in case of flexible couplinIg. In case of direct coupling Anti-Vibration mountings shall be provided for the Engine as well as the alternator.

-

-

-

... More
Power Generator should have protection against under voltage, over voltage, under frequency, over frequency, low battery voltage, over current, earth-fault, short circuit, phase sequence change etc.

-

-

-

... More
Automatic Mains Failure (AMF) control panel, shall be able to start up the Power Generator and transfer the load on to the Power Generator on mains failure without requiring any human intervention. Similarly on restoration of mains supply, it shall be able to transfer the load to mains supply and switch off the Power Generator automatically

-

-

-

... More
Control Panel , shall be equipped with suitableVoltmeter, Ammeter, Frequency meter, power factor meter (these items can be alternatively supplied in one multifunctional digital display meter), battery charger, indicators, various switches and cutout / MCB / MCCB / Contactor / Circuit breaker for the DG output of appropriate rating and accuracy class as per trade practice for better utility.

-

-

-

... More
Acoustic Enclosure shall be made of Pre-treated and Powder coated CRCA Sheet. The sheet shall be Pre-treated and Powder coated with weather-proof paint. The Acoustic Enclosure shall be vermin proof. The enclosure shall accommodate the fuel tank of the Power Generator to make the system compact.

-

-

-

... More
Power Generators shall meet the requirements of Environmental (Protection) Rules 1986 as laid down by Ministry of Environment & Forests read with GSR 371 (E) dated 17.5.2002,GSR520(E) dated 1.7.2003 , No.448 (E)dated 12.07.2004 , GSR 771(E) dated 11.12.2013 GSR232(E)dated 31.03.2014, Gazette Notification No.167 dated. 31.03.2014 and Gazette Notification No. 578 dated. 11.11.2014 in respect of noise and emission norms. The latest amendments to above GSRs shall be applicable as amended by Ministry of Environment and Forest.

-

-

-

... More
Standard set of Supply, Installation, Commissioning & Testing of 50 kVA, 3 Phase Diesel Generator Set with AMF Control Panel and its connected accessories at HVF Estate as per Technical Specifications- Qty- 1 No.s consisting of a set of 3 spanners, one screw driver, one standard plier and one nose plier of appropriate size shall be provided along with each Power Generator.

-

-

-

... More
Supply of Fuel tank of suitable capacity, sufficient for minimum 8 hours running the Power Generator, is inclusive in the scope of supply. Fuel Tank shall be complete with fuel piping (between fuel tank and diesel engine), valves, level indications and all standard accessories. MS pipes, heavy class of suitable dia conforming to IS 1239 (Part-1) - latest shall be used for fuel piping.

-

-

-

... More
Scope of Installation

-

-

-

... More
Installation: With Installation inclusive in the scope of supply

-

-

-

... More
Installation of Power Generators shall be done by the seller. The installation work of Power Generator and its constituent parts shall be generally conforming to CPWD General Specifi cation for Electrical Works, Part - VII - latest. b) Foundation shall be constructed by the seller. Foundation shall be of PCC type with the ratio of 4:2:1. The length and breadth of the foundation shall be 300mm more from the respective length and breadth of the Power Generator. The height of the foundation shall be 400 mm, i.e., 200 mm below and 200 mm above the ground level. All the materials / labour required for foundation work shall be supplied by the seller.

-

-

-

... More
Supply, laying and termination of inter connecting power and control cable shall be done by the seller. The cable supplied shall be ISI marked heavy duty PVC insulated, armoured cable, with PVC outer Sheath , with aluminium conductor having insulation of PVC compound type -C, suitable for rated voltage upto and including 1100 volts and conforming to IS: 1554 (Part-1) latest. Total length of the cable supplied by the seller shall be 60 metres of minimum 3.5CX35 sqmm for each Power Generator.

-

-

-

... More
Construction of suitable earthing station and necessary connections shall be done by the seller. All the materials / labour required for construction of earthing station shall be supplied by the seller. The total number of earthing pits/stations shall be 4, i.e., 2 for neutral and 2 for body- earthing for each generator. Neutral earthing shall be done with copper Plate and Body earthing shall be done with G.I. plate / Copper. The consignee should choose installation site in such a way that the earthing stations can be made within 10 metres of the Power Generator. Earthing station shall be typically constructed as per prevalent standard practices and shall be generally conforming to CPWD General specification for Electrical Works.Installation of fuel tank including foundation/stand shall be done by the seller.

-

-

-

... More
Supply & delivery of 100 Ltr of Diesel for testing and commissioning purpose.

-

-

-

... More
Supplying and fixing 415V, 63 A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.[make-L&T/ Siemens/ABB]

1

-

-

... More
Supplying and fixing 415V, 100 A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.[make-L&T/ Siemens/ABB]

1

-

-

... More
Supplying and fixing 415V, 63 A Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc[make-L&T/ Siemens/ABB]

1

-

-

... More
Supplying and fixing 415V, 100 A Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc[make-L&T/ Siemens/ABB]

1

-

-

... More
Supplying & Erection of big size feeder pillar box of Size (1372 x 914 x 607 mm) made up of 3.15 mm thick MS Plate along with suitable M.S. Angle. The P.B. have double hinge door at the front & back with suitable locking arrangement. The box will be painted by 2 cores of aluminiam paint over 1 coat of red oxide paint. Suitable arrangement should be provided for fixing of Timer unit, fuse unit & other accessories. Leg of the pillar box will be 900 mm in length by made up of (35x35x3 mm MS Angle with suitable base Plate. Legs of the Pillar box will be erected at 300 mm below the ground level with cement concrete (6:3:1). Rest portion coverd by 5" Brick Wall with plastering & net cement & bottom portion filled with silver sand as drawing & direction of E.I.C.

1

-

-

... More
Supply & Delivery of PVC/XLPE Insulated & Sheathed Armoured Aluminium Conductor Cables for Working Voltage up to 1100 Volts of following sizes. [ Make - Polycab/Gloster/RR ]

-

-

-

... More
a) 3.5 Core 70 Sqmm

40

-

-

... More
b) 3.5 Core 50 Sqmm

40

-

-

... More
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed

80

-

-

... More
S&F of compression type gland complete with brass gland, rubber rings for dust & moisture proof entry of PVC armoured cables as below as per G.S. [F4/7c]

-

-

-

... More
a) 3.5 Core 70 Sqmm

7

-

-

... More
b) 3.5 Core 50 Sqmm

7

-

-

... More
Finishing the ends of following cables by crimping method including S/F dowells solderless sockets, tapes and jointing materials etc. as per G.S.[F5/8b]

-

-

-

... More
a) 3.5 Core 70 Sqmm

7

-

-

... More
b) 3.5 Core 50 Sqmm

7

-

-

... More
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled withbitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: (a) By TATA-Medium GI pipe

4

-

-

... More
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe

4

-

-

... More
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required

1

-

-

... More
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.

25

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.