Public Works Department Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Public Works Department - PWD Tender
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date28 Feb 2024
Closing Date19 Mar 2024
Tender Amount₹ 12,90,021 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 25,940Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Sitc Of New Lt Distribution Panel
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WBPWD_675836_1Bid Award Id
ViewTender No
WBPWD/EE/DDED/e-NIQ-39 of 2023-24Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://wbpwd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make- Legrand/Seimens/Schneider)
-
-
-
i) 2+8 way Enclosure (607711)
1
-
-
Supplying and fixing 240V SP MCB of Breaking apacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (Make- Legrand/Seimens/Schneider)
-
-
-
i) 6-16 A
8
-
-
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the 20mm/25mm size PVC rigid conduit FR(Precision make) incl. Necy fittings as required
-
-
-
ii)2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
40
-
-
iii)2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
35
-
-
iv)2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC
35
-
-
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes
-
-
-
i) 2.5 sq mm
10
-
-
ii) 4 sq mm
10
-
-
iii) 6 sq mm
10
-
-
Supply & Fixing 240 V, 20A, plug socket with separate 20 APiano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F150 x 100 x 65mm MS (16SWG) switch board and bakelite /perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
4
-
-
Supply & Fixing Socket type fan regulator (Step type) (Anchor) on existing sheet metal switch board with bakelite/ perspex top cover by screw incl. making necy. connections etc. as per G.S.
4
-
-
Supplying and fixing 4 core compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
-
-
-
a) 4 core 16sqmm
2
-
-
c) 4 core X 50 sq.mm
8
-
-
e) 4 core X 95 sq.mm
6
-
-
f) 4 core X 120 sq.mm
16
-
-
h) 4 core X 240 sq.mm
2
-
-
Finishing of the XLPE/PVC insulated armoured cable ends by crimping method with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc.
-
-
-
a) 4 core 16sqmm
2
-
-
c) 4 core X 50 sq.mm
8
-
-
e) 4 core X 95 sq.mm
6
-
-
f) 4 core X 120 sq.mm
16
-
-
h) 4 core X 240 sq.mm
2
-
-
S & D of 1.1 KV. Gr. armored XLPE/A Al. LT cable of following [Make: Policab/Gloster/Havells/RR] KEI
-
-
-
a) 4 core 16sqmm.
110
-
-
b) 4 core X 50 sq.mm.
260
-
-
c) 4 core X 95 sq.mm.
65
-
-
d) 4 core X 120 sq.mm.
80
-
-
d) 4 core X 240 sq.mm.
110
-
-
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
110
-
-
Laying of one No. cable above 35 sqmm and upto 185 sqmm in
underground trench 460mm wide x 760mm average depth, with
brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
405
-
-
Laying of one No. cable above 185 sqmm in underground trench
460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
110
-
-
Fixing only single/Twin fluorescent/LED light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length.
4
-
-
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
4
-
-
Supply & Delivery of 4 feet single commercial LED type light fittings complete with all accessories with 1 x 18 Wt.Master LED Tube lamp similar to Philips make cat No. TMC-501 P1xTLED 22 WP3241 corresponding to Wipro / Bajaj / Crompton.
6
-
-
Supply & Delivery 240V 50 Hz 48" sweep (1200 mm) AC ceiling fan complete with down rod , Canopy, fork etc. with out regulator, (Make- Usha striker Plus/ Crompton Greaves/ Orient )as per direction of EIC
4
-
-
Earthing with Copper plate (610x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) & 1 no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt. long) to be fillied with bitumen, partly under the ground level & partly above ground level to an average depth of 3.65 Mts.
below the ground level and restoring the surface duly rammed incl. providing 3.0 mt long, 25 mm dia GI pipe (ISI-Medium) for periodic treatment, incl. providing masonery enclosure on the top of the earth electrode of overall size 86.36x86.36x46cm deep (below Ground level) complete with cemented brick work (1:6) of 25 cm width, duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56x35.56cm with locking arrangement, GI reducer and treatment of soil by using salt & charcoal or coke for plate electrode.
2
-
-
Extra for connecting the neutral of DG/Earth busbar to earth electrode including S & F Galvanized (Hot Dip) Steel strip 65 mm x 8 mm on wall/floor with GI saddles & insulating the same by one layer of PVC strip over one layer of ampere tape.
10
-
-
Excavation of soil for installation of Earth Electrode and filling
& ramming. (a) For Soft Soil
15
-
-
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed. a)By- ISI-Medium GI pipe as to GS.
5
-
-
Connecting the equipments to earth busbar including S & F 25x6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages as to GS.
75
-
-
Supply,Installation,Testing & commissioning of cubical type panel,compartmentalized wall mounted indoor type dust and vermin proof powder coated panel panel board ,suitable for 415V 3phase ,4wire ,50HZ ,ac supply of suitable size made out of 2mm thick MS sheet so as accommodate the following mounting complete with copper busbar of 415A capacity ,detachable gland plate,with suitable size 4mm thick MS channel frame at the bottom,with adequate size cu wire ,copper bar ,cu link cable connector etc along with necy nuts,bolts,clamps,grounting bolts incl providing and fixing the following accessoried etc complete as required .(all make L&T) DG Incommer Panel incomer--
i) S/F of 415 Volts 315A SFU with 3Nos DIN type HRC
fuse as per rating (Make-L&T)-- 02 Nos ii) S/F of 415 Volts 315 A On-load Changeover (Mk. L&T)-- 01 Nos Outgoing-- i) S/F of 415 Volts 200A SFU with 3Nos DIN type HRC
fuse as per rating (Make-L&T)-- 02 Nos ii) S/F of 415 Volts 125A SFU with 3Nos DIN type HRC
fuse as per rating (Make-L&T)-- 02 Nos BUS BAR c) do-do 415 Amp capacity 4 bar electrolytic tinned copper bus bar mounted on non-hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification --- 01 Set METERING
a)0-500V digital volt meter----1no.
b)0-600A flush mounting digital ammeter(AE) with selector switch—1no.
c) 600/5A ratio C.T's----6nos.
d)250V LED(RYB) source indicating lamps with sliding control fuses and selector swithches-----1 SET
e) EI danger board----1Nos
f) Proper earthing arrangement
1
-
-
Supply,Installation,Testing & commissioning of cubical type panel,compartmentalized wall mounted indoor type dust and vermin proof powder coated panel panel board ,suitable for 415V 3phase ,4wire ,50HZ ,ac supply of suitable size made out of 2mm thick MS sheet so as accommodate the following mounting complete with copper busbar of 415A capacity ,detachable gland plate,with suitable size 4mm thick MS channel frame at the bottom,with adequate size cu wire ,copper bar ,cu link cable connector etc along with necy nuts,bolts,clamps,grounting bolts incl providing and fixing the following accessoried etc complete as required .(All make L&T) DG-I OUTPUT Panel incomer--
i) S/F of 415 Volts 250A SFU with 3Nos DIN type HRC
fuse as per rating (Make-L&T)-- 02 Nos ii) S/F of 415 Volts 250 A On-load Changeover. (Mk. L&T)-- 01 Nos Outgoing-- i) S/F of 415 Volts 200A SFU with 3Nos DIN type HRC
fuse as per rating (Make-L&T)-- 02 Nos ii) S/F of 415 Volts 150A SFU with 3Nos DIN type HRC
fuse as per rating (Make-L&T)-- 01 Nos iii) S/F of 415 Volts 63A SFU with 3Nos DIN type HRC
fuse as per rating (Make-L&T)-- 02 Nos BUS BAR c) do-do 315 Amp capacity 4 bar electrolytic tinned copper bus bar mounted on non-hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification --- 01 Set METERING
a)0-500V digital volt meter----1no.
b)0-600A flush mounting digital ammeter(AE) with selector switch—1no.
c) 600/5A ratio C.T's----6nos.
d)250V LED(RYB) source indicating lamps with sliding control fuses and selector swithches-----1 SET
e) EI danger board-1Nos
f) Proper earthing arrangement
1
-
-
Supply,Installation,Testing & commissioning of cubical type panel,compartmentalized wall mounted indoor type dust and vermin proof powder coated panel panel board ,suitable for 415V 3phase ,4wire ,50HZ ,ac supply of suitable size made out of 2mm thick MS sheet so as accommodate the following mounting complete with copper busbar of 415A capacity ,detachable gland plate,with suitable size 4mm thick MS channel frame at the bottom,with adequate size cu wire ,copper bar ,cu link cable connector etc along with necy nuts,bolts,clamps,grounting bolts incl providing and fixing the following accessoried etc complete as required .(All make L&T) DG-2 Output Panel Incomer--
i) S/F of 415 Volts 250A SFU with 3Nos DIN type HRC
fuse as per rating (Make-L&T)-- 02 Nos ii) S/F of 415 Volts 250 A On-load Changeover. (Mk. L&T)-- 01 Nos Outgoing-- i) S/F of 415 Volts 250A SFU with 3Nos DIN type HRC
fuse as per rating (Make-L&T)-- 01 Nos ii) S/F of 415 Volts 200A SFU with 3Nos DIN type HRC
fuse as per rating (Make-L&T)-- 02 Nos iii) S/F of 415 Volts 125A SFU with 3Nos DIN type HRC
fuse as per rating (Make-L&T)-- 03 Nos iii) S/F of 415 Volts 63A SFU with 3Nos DIN type HRC
fuse as per rating (Make-L&T)-- 02 Nos BUS BAR c) do-do 315 Amp capacity 4 bar electrolytic tinned copper bus bar mounted on non-hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification --- 01 Set METERING
a)0-500V digital volt meter----1no.
b)0-600A flush mounting digital ammeter(AE) with selector switch—1no.
c) 600/5A ratio C.T's----6nos.
d)250V LED(RYB) source indicating lamps with sliding control fuses and selector swithches-----1 SET
e) EI danger board-1Nos
f) Proper earthing arrangement
1
-
-
The Rates to be quoted by all the bidders should be Inclusive of all taxes and duties including GST and LWC.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements