Public Works Department Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Public Works Department - PWD Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date17 Jan 2025
Closing Date11 Feb 2025
Tender AmountRefer Documents
Costs
EMD
₹ 22,158Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Wbpwd/ee-i/ckhed/enit79(r )/24-25
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_WBPWD_797010_1Tender No
WBPWD/EE-I/CKHED/eNIT79(R )/24-25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://wbpwd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Make:- Legrand, Model- Arteor or Myrius/ Anchor, Model- Woods/ Havells, Model- Oro Series), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy.connections with PVC Cu wire and earth continuity wire etc. (For computer board) [Ref.- E-18/12]
2
-
-
... More
Supply & Fixing 240 V, 2 nos. 6 A, 3 pin Modular type plug socket with 2 nos. 6A Modular type switch (Make:- Make:- Legrand, Model- Arteor or Myrius/ Anchor, Model- Woods/ Havells, Model- Oro Series), without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy.connections with PVC Cu wire and earth continuity wire etc.(For mobile charging point and water purifier point) [Ref.- E-17/1(b)+3(a)+4(a)]
2
-
-
... More
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Make:- Make:- Legrand, Model- Arteor or Myrius/ Anchor, Model- Woods/ Havells, Model- Oro Series) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [Ref.- E-18/9(a)]
10
-
-
... More
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket with 16A Modular type switch (Make:- Make:- Legrand, Model- Arteor or Myrius/ Anchor, Model- Woods/ Havells, Model- Oro Series), without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [Ref.- E-18/9(b)]
4
-
-
... More
C. Distribution Wiring & Point Wiring
-
-
-
... More
Distn. wiring in 3 x 1.5 sq. mm single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make:- Finolex/ Havells/ Polycab/ RR Kabel/ Gloster) in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Make:- Make:- Legrand, Model- Arteor or Myrius/ Anchor, Model- Woods/ Havells, Model- Oro Series) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish. 2 x 1.5 (Ph. & N) and 1 x 1.5 as ECC. [Ref.- E-20/1]
-
-
-
... More
Average run 6 mtr
75
-
-
... More
Averag run - 8 Mtr.
75
-
-
... More
Distn. wiring in 3 x 1.5 sq. mm single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make:- Finolex/ Havells/ Polycab/ RR Kabel/ Gloster) in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6 A 3 pin Modular type plug socket & Modular type switch (Make:- Make:- Legrand, Model- Arteor or Myrius/ Anchor, Model- Woods/ Havells, Model- Oro Series) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish. [Ref.- E-20/3]
-
-
-
... More
On Board
26
-
-
... More
Average run 4.5 mtr
5
-
-
... More
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make:- Finolex/RR Kabel/PolyCab / Gloster/ Havells) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required [Ref : E-9/1]
-
-
-
... More
3x22/0.3 (1.5 sqmm)
1018
-
-
... More
2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
450
-
-
... More
2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC
200
-
-
... More
4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC
70
-
-
... More
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles. [Ref : E-3/6(a)]
-
-
-
... More
19 mm dia 3 mm thick polythene pipe without earth continuity wire
1738
-
-
... More
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works. [Ref : E-4/11(b)(c)]
-
-
-
... More
150 mm x 100 mm x 65 mm
10
-
-
... More
175 mm x 100 mm x 65 mm
5
-
-
... More
Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required. [Ref : E-4/12(b)(c)]
-
-
-
... More
150 mm x 100 mm x 65 mm
10
-
-
... More
175 mm x 100 mm x 65 mm
5
-
-
... More
Supply & Fixing 240 V 6 A Piano key type switch (Make:- Anchor/ Havells/ ABB) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. [Ref : E-5/14(a)]
25
-
-
... More
Supply & Fixing 240 V, 6A plug socket (Make:- Anchor/ Havells/ ABB), without switch & plug top, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for plug by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc. [Ref : E-5/15(a)]
25
-
-
... More
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [Ref : F-5/9]
-
-
-
... More
3 x 1.5 sq. mm
60
-
-
... More
2 x 2.5 sq. mm + 1 x 1.5 sq. mm
40
-
-
... More
2 x 6 sq. mm + 1 x 4 sq. mm
30
-
-
... More
4 x 10 sq. mm + 2 x 6 sq. mm
10
-
-
... More
D. Cable
-
-
-
... More
Supply of following size 1.1 kV (1100V) grade Multi-Stranded, XLPE/PVC insulated, Armoured Al. LT cable. (Make:- Finolex/RR Kabel/PolyCab / Gloster/ Havells /KEI)
-
-
-
... More
4 Core 50 Sqmm
40
-
-
... More
Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting. [Ref: F-1/2(c)]
10
-
-
... More
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish. [Ref : F-3/5]
-
-
-
... More
Above 35 sqmm to 95 sqmm at an average depth of 100 mm in
floor/pavement/wall etc.
30
-
-
... More
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below [Ref : F-4/7(c)]
-
-
-
... More
For 4 Core upto 50 Sqmm
2
-
-
... More
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. [Ref : F-5/8(b)]
-
-
-
... More
For 4 Core upto 50 Sqmm
2
-
-
... More
E. Indoor Lighting
-
-
-
... More
S&D of 240V,1-Ph.,50Hz, 4' (feet) long Single LED T8 Tube light batten fitting along with 1 no. LED T8 Tube light (Polycarbonate Body) having efficacy of =100 lumen/watt incl. end cap and complete with all accessories. [Make:- Philips, Batten Cat No.- TMC100 1xTLED 13-20w WH & Tube light Cat No.- Mas LED Tube 1200mm 18W 865 T8 I – 2100lm or Crompton, Batten Cat. No.- IGP161LT8-16 1 x T8 & Tube light Cat No.- LTB-20-865-(2)]
4
-
-
... More
S&D of 240V,1-Ph.,50Hz, 4' (feet) long Twin LED T8 Tube light batten fitting along with 2 nos. LED T8 Tube light (Polycarbonate Body) having efficacy of =100 lumen/watt incl. end cap and complete with all accessories. [Make:- Philips, Batten Cat No.- TMC100 2xTLED 13-20w WH & Tube light Cat No.- Mas LED Tube 1200mm 18W 865 T8 I – 2100lm or Crompton, Batten Cat. No.- IGP162 LT8-16 2 x T8 & Tube light Cat No.- LTB-20-865-(2)]
30
-
-
... More
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [Ref : C-2/17]
14
-
-
... More
Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener. [Ref.- C-2/14(b)]
20
-
-
... More
F. Outdoor Lighting
-
-
-
... More
S&D of 240V,1-Ph.,50Hz, LED flood light delivering minimum 120 lumen/watt including IP66 & 10kV Surge Protection Device and complete with all accessories.
-
-
-
... More
70W [Make:- Philips Field Star, Cat No.- BVP281 LED085 CW FG SY5WB 70W SPD V1 or Cromptom Profile Neo, Cat No.- LFL-70-CDL/60-M]
8
-
-
... More
100W [Make:- Philips Field Star, Cat No.- BVP282 LED120 CW FG SY5WB 100W SPD V1 or Cromptom Rover Plus, Cat No.- TFS-504-100-57-60D-HL2-GL-NSG]
8
-
-
... More
Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. [Ref : C-3/18]
16
-
-
... More
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint. [Ref : H-5/5]
16
-
-
... More
Supply and fixing of 1 phase timer control box for controlling Compound Light made following accessories with IP - 42/43 protection with front door locking arrangement with all connection on angel iron frame on wall as per instruction of EIC.
1
-
-
... More
a) 2+10 way size double door SPN MCBDB--1 No. (L&T)
-
-
-
... More
b) 240/415V, AC 32A, 2P Power contactor type MNX22-2P (Make-L&T) - 1 No.
-
-
-
... More
c) Daily & weekly programmable basis Digital Timer Switch, min switching time 1 min, ON/OFF programs- 1 no.(L & T Cat no. - 67DDT0)
-
-
-
... More
d) 240/415V, 40A, DP MCB Isolator (Make:Legrand) 1 no
-
-
-
... More
e) 3 way Auto manual toggle switch--1 no.
-
-
-
... More
f) ON/OFF LED indicator - 1 set
-
-
-
... More
g) ON/OFF push button - 1 set.
-
-
-
... More
h) Interconnection by 2.5 sqmm Cu wire--3 mtr.
-
-
-
... More
Supply of following size 1.1 kV (1100V) grade Multi-Stranded, XLPE/PVC insulated, Armoured Al. LT cable. (Make:- Finolex/RR Kabel/PolyCab / Gloster/ Havells /KEI)
-
-
-
... More
2 Core 10 Sqmm
400
-
-
... More
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting. [Ref : F-1/2(a)]
400
-
-
... More
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below [Ref : F-4/7(a)]
-
-
-
... More
For 2 Core upto 10 Sqmm
32
-
-
... More
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials [Ref : F-5/8(b)]
-
-
-
... More
2 core 10 sqmm cable
32
-
-
... More
Supply, febrication ,welding and painting of (900mm x 400 mm x 250 mm) MS Cage for outdoor compound light including making housing fot 40mm dia for single arm bracket with (20mmx3 mm) MS flat should be fanced by 14 SWG MS Chicken Mesh net guard (1 square inch shape hole ) to cover up the entire cage rigidly wilded wth (20 mm x 20 mm x 3 mm ) MS equal angle channel.
112
-
-
... More
G. Ceiling Fan, Exhaust Fan, Air Circular Fan etc.
-
-
-
... More
Supply of 240V,1-Ph., 48" (1200mm) sweep, high speed AC ceiling fan, the capacitor of fan must be P-2 type brust proof & must have safety wire directly linked from fan hook to stator of fan. including safety wire and complete with all accessories like blades, canopy, fork, rubber bush, downrod etc. (Make:- Crompton Riviera Hi Speed/ Orient-Quassar/ CG Aura metallic) Colour:- Brown/ Metallic Ivory Cherry.
30
-
-
... More
Supplying & Fixing MS fan clamp of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991) [Ref : D-14/29]
30
-
-
... More
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Make:- Legrand, Model- Arteor or Myrius/ Anchor, Model- Woods/ Havells, Model- Oro Series) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. [Ref : E-18/10]
30
-
-
... More
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. [Ref : C-3/21(a)]
30
-
-
... More
Engraving the deptt. number with 10 mm lettering on the body of fan upto 10 letters incl. hifen, stroke or stop. [Ref : C-3/24(a)]
30
-
-
... More
Extra for additional one letter incl. hifen, stroke and stop. [Ref: C-3/24(b)]
90
-
-
... More
Painting upto 10 letters of the engraved number with approved black /red paint as required. [Ref : C-3/26(a)]
30
-
-
... More
Extra painting for additional one letter of the engraved number with hifen, stroke etc. with black or red paint. [Ref : C-3/26(b)]
90
-
-
... More
Supply of 240V,1-Ph.,50Hz, full metal body with metal blades heavy duty AC Exhaust Fan complete with all accessories. [Make:- Crompton/ EPC/ Usha/ Orient]
-
-
-
... More
12'' (30cm or 300mm) [80Watt, 1420RPM]
10
-
-
... More
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: [Ref : C-4/28]
-
-
-
... More
12'' (30cm or 300mm)
10
-
-
... More
Supply & Fixing Al. louver shutter for the exhaust fan on wall with necy. bolts & nuts (6 mm dia x 62 mm long) [Ref : D-14/32(a)]
-
-
-
... More
12'' (30cm or 300mm)
10
-
-
... More
H. Earthing by GI Pipe Electrode
-
-
-
... More
Excavation of soil for installation of Earth Electrode and filling & ramming. [Ref.: G-1/1]
-
-
-
... More
For Morrum Soil
6
-
-
... More
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: [Ref.: G-1/2(a)]
-
-
-
... More
By TATA-Medium GI pipe
2
-
-
... More
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [Ref.: G-2/3(a)]
2
-
-
... More
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. [Ref.: G-2/4(c)]
2
-
-
... More
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. [Ref.: G-3/5(d)]
30
-
-
... More
Rate should be quoted incl. of all taxes and cess.
-
-
-
... More
Defect Liability period : 1 year
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%