Public Works Department Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Public Works Department - PWD Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date13 Aug 2024
Closing Date29 Aug 2024
Tender AmountRefer Documents
Costs
EMD
₹ 23,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WBPWD_733756_1Bid Award Id
ViewTender No
WBPWD/EE-KED/eNIQ-22Q/24-25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://wbpwd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Providing on hire basis 415V, 100 A TPN SFU in SS enclosure with Rewirable / HRC fuses on wooden plank board or suitable angle iron frame incl. Providing interconnection wiring with socketing, earthing attachment etc. and dismentaling at the of end function (with PWD / E.I.C.approved materials)(Hiring upto 20 days)
1
-
-
Providing on hire basis 415V, bus bar chamber comprising of 4 nos. copper bars of 500 A capacity, fixed on angle iron frame including necessary interconnection wiring along with termination by socketing the cable/wire ends and 2 nos earthing attachment and dismantling the same after completion of the programme..(with PWD / E.I.C. approved materials)(Hiring upto 20 days)
1
-
-
Providing on hire basis 415V, bus bar chamber comprising of 4 nos. copper bars of 200 A capacity, fixed on angle iron frame including necessary interconnection wiring along with termination by socketing the cable/wire ends and 2 nos earthing attachment and dismantling the same after completion of the programme..(with PWD / E.I.C. approved materials)(Hiring upto 20 days)
1
-
-
Providing on hire basis 415V, Upto 8 Way 100 amp,VTPNDB With 100 amp MCCB As Incoming 8 No. - 63 amp FPMCB as Outgoing including necssary interconnection wiring in a outdoor type pillar box along with necessary termination by socketing the cable/wire ends including 2 nos earthing attachment and dismantling the same after completion of the programme.(with PWD / E.I.C. approved materials)(Hiring upto 20 days)
12
-
-
Providing on hire basis 415V, Upto 6 Way TPNBDB With 1 No. - 63 amp FPMCB as Incoming & 18 No. 6-32 amp SPMCB as Outgoing including necssary interconnection wiring in a outdoor type pillar box along with necessary termination by socketing the cable/wire ends including 2 nos earthing attachment and dismantling the same after completion of the programme.(with PWD / E.I.C. approved materials)(Hiring upto 20 days)
16
-
-
Providing on hire main wiring with 1.1 KV grade Aluminium Conductor PVC / XLPE armoured cable of following sizes including laying in trench (at least 230 mm below ground) including dismantling the same and mending good the damages.(Hiring upto 20 days)
-
-
-
4 core 16 sq mm
600
-
-
4 core 50 sq mm
350
-
-
Supplying & Drawing on Hire Basis following size single core PVC insulated, unsheathed, multistrand copper/Al wire including necessary termination by socketing the wire ends & dismantling the same after completion of the program.(with PWD / E.I.C. approved materials)(Hiring upto 20 days)
-
-
-
7/0.064(7/16) Single Core
18000
-
-
7/0.036(7/20) single core
12000
-
-
Providing and Fixing on hire basis following LED Flood light fittings complete with bracket & clamp on the pole incl. accessories and dismantling as directed by EIC after the programme(Hiring upto 20 days)
-
-
-
Minimum 200 Watt LED Flood fittings. (Crompon/Philips/Bajaj/Nordusk)
500
-
-
Supplying & providing on Hire basis 1 no Seperate 6 amp plug and Switch with 150X100X65mm MS/TW switch Board including necy. wiring in 3 x1.5 sq mm single core PVC insulated, unsheathed, multistrand copper wire (avg. Length 5 mtr) & dismantling the same after completion of the program.(Hiring upto 20 days)
200
-
-
Supplying & providing on Hire basis 1 no Seperate 20 amp plug and Switch with 150X100X65mm MS/TW switch Board including necy. wiring in 3 x2.5 sq mm single core PVC insulated, unsheathed, multistrand copper wire (avg. Length 5 mtr) & dismantling the same after completion of the program.(Hiring upto 20 days)
20
-
-
Supplying & providing on hire basis 1200mm sweep ceiling fan complete set with hanging arrangement incl.3 x 1.5 sqmm copper wire connection & dismantling the same after completion of the program.(Hiring upto 20 days) (PWD/EIC approved materials)
20
-
-
Supplying & providing on hire basis 40V A. C. 600 mm / 24" sweep Air Circulater Pedestal Fan with 3 pin plug top and dismantling the same(Hiring upto 20 days) (PWD/EIC approved materials)
30
-
-
Supply & Providing Earthing on hire basis with 50 mm dia GI Pipe 2.5 to 3 mtrs. Long and 6/8 SWG GI wire with galvanized nuts and bolts washer etc. below ground level on hire basis and dismantling the same.(Hiring upto 20 days)
120
-
-
Supplying & providing on hire basis following items for 01 Day with carrying cost at the sites including necessary connecting cables.(Make: Crown/Crest Audio/Equivalent of same specification)
-
-
-
Speaker box of 1000 Watt (Make: Crown/Crest Audio/Equivalent of same specification)
6
-
-
Power Amplifier system for the speakers and microphones.The agency needs to provide the amplifiers as required at site.(Make: Crown/Crest Audio/Equivalent of same specification)
3
-
-
S & D Cordless Microphone (Make: Shure/Samson/Equivalent of same specification)
8
-
-
S & D of Corded gooseneck Microphone (Make: Shure/Samson/Equivalent of same specification)
2
-
-
Deployment of 03 no. Skilled Technician & 03 no. Helper per shift per day (i.e. Total 9 nos Electrician & 9 nos Helper per day for 24 Hrs) for carring out all kind of EI maintenance ,DG operations including PA system & proper upkeepment and preventing any unwanted incidents like theft, willful damage etc.
(no additional charge will be paid for any unwanted incidents)
20
-
-
Supplying & providing on hire basis CPCB approved following ratings soundless Diesel Generator Set (DG set Without diesel) with mobil including one operator, appropriate size of cable upto 120 Mtrs including necessary interconnection, socketing & dismantling as directed by EIC after the program.If the DGs are not placed at site on time, pro rata rate will be reduced from bill.
-
-
-
62.5 kVA 1 Set
20
-
-
25 kVA 1 Set
20
-
-
Supply & Pouring of HSD for the hired DG set incl handling cost.(the measurement will be done after considering all technical aspect, original invoice & log book)
4080
-
-
Special Terms and conditions for Temporary E.I. Work -
1) Earthing should conform to IS specification. Earth Continuity wire should not be broken / Jointed. Single Earth continuity wire should be used from Earth Bus-Bar to the installation.
2) Main Electrical Panel Should be earthed by two nos. of separate earthing.
3) MCB / Rewirable Fuse type Distrubution Board should be installed with proper Trip Current setting / fuse wires. However, MCB type DBs are preferable.
4) No Part of the Electrical Circuit in the pandal / Structure shall be within 12 inches of any decorative cloth / paper.
5) Ordinary Flexible wires should not be used. Only new PVC insulated & sheathed wires (Bearing ISI mark) or PVC insulated wires of FRLS (Fire Resistant Low Smoke) type (ISI Marked) are allowed.
6) All cable ends should be properly sockedted.
7) All joints shall be made with porceline insulated connectors. Twisted & lapped joints shall be avoide. But Joints are strictly not allowed in the dias.
8) Cables / Wires should run along outside the Dias.
9) Ceiling fan (s) / Electrical fittings must not be suspended from the ceiling of Dias. Pedestal fans are not allowed on the Dias. However, Pedestal fans may be installed outside dias, but the body of the fan must be properly earthed.
-
-
-
10) T/L fittings shall be of box type (Indoor commercial type). Any kind of open type fittings must be avoided.
11) Each A.C. Machine should be connected with a separate circuit and earthing should be provided by separate single earth contunuity wire from Earth Bus-bar.
12) P.A. System and Microphone shoud be earthed.
13) Sufficient quantity of Fire Extinguishers and First Aid Box should be provided.
14) If the DGs are not placed at site on time pro rata rate will be reduced from bill.
15) No additional charges will be paid for any unwanted incidents like theft, willfull damage etc.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements