Public Works Department Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Public Works Department - PWD Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date10 Jan 2025
Closing Date29 Jan 2025
Tender Amount₹ 11,71,131 
Notes
Download

Costs

Summary

Wbpwd/kshd/ee/nit-42 Of 2024-2025_sl.02

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Taking out existing partition/ceiling of particle board, masonite board, ply board, soft board etc. of any thickness and refixing same in new position with necessary clamps making holes in walls, floor, roof and mending damages if any.

24.3

55

1337

... More
Brick work with 1st class bricks in cement mortar (1:6) (b) In superstructure, 2nd floor

1.91

5813

11120

... More
3rd floor

1.91

5924

11333

... More
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. 2nd floor

2.7

752

2032

... More
3rd floor

2.7

764

2064

... More
M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968 & IS: 1161- 1998 cnnected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816- 1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. i) For trusses spanning up to 12.00 m 2nd floor

1.44

74045

106773

... More
M.S. works in brackets made from flats, angles, tees etc. to sizes specialy bent, twisted, forged; making holes drilled and fitted to rafter of trusses with necessary bolts, nuts, washer or screws etc.

3.65

9984

36392

... More
Welding in M.S. structural work with gas or electric: (a) Tack weld

280

9

2520

... More
(b) Continuous weld.

240

9

2160

... More
Supplying ready mixed concrete of M 25 Grade with well graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu.m of wet concrete produced in computerised batching plant under controlled condition using approved super plastisizer, designing concrete mix following I.S. 10262 and I.S. 456, transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required levels of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification & direction of the Engineer-in-charge including computerised batching plant transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. ii) With approved concrete pump 1st floor

1.62

7504

12157

... More
2nd floor

1.62

7524

12189

... More
3rd floor

1.62

7544

12222

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in 2nd floor as per relevant IS codes. a) Pakur Variety

0.68

5466

3717

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6 mm nominal size) excluding shuttering and reinforcement,if any, in 2nd floor as per relevant IS codes. a) Pakur Variety

0.12

5461

666

... More
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in 2nd floor as per relevant IS codes. (i) Pakur Variety

0.3

5962

1771

... More
3rd floor

0.3

6007

1784

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. 2nd floor

4.55

371

1688

... More
3rd floor

4.55

389

1770

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of 1st floor/upto 4 m (i) Tor steel/Mild Steel I. SAIL/ TATA/RINL

0.25

55420

13855

... More
2nd floor

0.3

55900

16826

... More
3rd floor

0.3

56380

16970

... More
Supplying and application of chemical for post Installed rebar connection by using ETA approved for seismic criteria In rebar connection, Including drill/ng hole to the required depth by rotary hammer drill, cleonlng with brush &jet of clean air, /ill/ng chemical usIng serrated noule to eliminate mIxIng error and in a voldless manner IncludIng charges for all tools & plants. Application to be designed for post· Installed rebars as per ECZ/TR023 or relevant tested and accepted design guidelines and the design document to be furnished by the manufacturer. The chemical should have ETA apprOVal for seIsmIc criteria of rebar fixing whIch should be furnished by manufacturer. The installation and the setting instructions should be strIctly followed as per manufacturer's specl/icatlons as approved by EICprior to drlll/ng along with post· Installed rebar embedment design report. The existing concrete member should be scanned using rebar scanner to avoid hitting existing reinforcement in concrete during drilling. iii) Cost of post Installed rebaring application with chemical as specified for 12 mm dia per cm of depth.

12000

21

252000

... More
iv) Cost of post Installed rebaring application with chemical as specified for 16 mm dia per cm of depth.

3600

27

97200

... More
Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy.

80

102

8160

... More
e) Extra for staging beyond 4 m in any floor (Mode of measurement: area in plan x mean height of staging upto soffit of shuttering above initial 4 m)

468

61

28548

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (2nd floor). (i) With 1:6 cement mortar (b) 15 mm thick plaster

162

156

25361

... More
Supplying, fitting, fixing marble slab/tiles, 15 mm. to 18 mm. thick in dado / wall in 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks applying white cement slurry @ 4.4 kg/ sq.m at the back side of marble & pointing in cement mortar (1:2) (1 cement, 2 marble dust) with admixture of pigment matching the stone shades including polishing all complete as per direction of the Engineer-in-charge including cost of materials, labours, scaffolding, staging, curing complete. (b) With Chawk Doongri (iii) Area of each tile exceeding 0.6 sq.m but not excedding 1 sq.m. 2nd floor

9.48

2741

25986

... More
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. B) Wall With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of each tile above 0.09 Sq.m (i) Coloured decorative 2nd floor

7.71

1112

8577

... More
3rd floor

7.71

1117

8615

... More
Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brand conforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) ≤ 0.08 %] in floor, skirting etc. using polymerised adhesive of 6mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course and joints grouted with admixture of white epoxy grout materials of approved brand including spacer -2mm as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges complete as per direction of Engineerin-Charge.(Note: This work should not be executed without specific permission of Superintending Engineer) (b) gr Floor :(a) ln 1st floor FIoor:(size not Iess than 600mmX 600 mm X 9.5 mm thick)

8.1

1498

12137

... More
2nd floor

8.1

1510

12234

... More
3rd floor

8.1

1522

12332

... More
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (a) 1st class Best Indian teak. 2nd floor

0.15

148944

22193

... More
Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. In 1st floor. (i) 50 mm thick shutters with 25mm thick panel of size 30 to 45 cm. (a) 1st class Best Indian teak 2nd floor

8.32

7299

60728

... More
Supplying solid flush type doors of deluxe decorative (both side) quality, conforming to I:S 2202 timber frame consisting of top and bottom rail and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 27.5mm wide battens places both ways in order to made the door of solid core and internal lipping with teak, mahogony or rose wood approved decorative veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing the shutters in position but excluding the cost of hinges and other fittings in 2nd floor: (a) 35mm thick shutters (single leaf)

6.47

2687

17385

... More
(B) Dressed wood work in post , plate , battens . etc. fitted & fixed complete (i) Sal : Siliguri. 2nd floor

0.09

103273

9398

... More
Scantling upto 50mm wide and 12mm thick (chamfering or rounding) for ceiling/partion battens including fitting, fixing in position with washers, coach screws etc. complete.: (a) Ordinary teak

91.88

104

9556

... More
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (a) 40mm X 6mm, 250mm Length

12

29

348

... More
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISImark. (viii) 100mm. X 75mm. X 3.50mm.

16

66

1056

... More
(b) Supplying 'Godrej' mortice lock chromium plated with keys 6 levers including fitting & fixing complete.

2

1954

3908

... More
(i) Door stopper.(Brass)

4

117

468

... More
ii) Godrej Hydraulic door closer fitted and fixed complete. (a) Heavy type

4

2064

8256

... More
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: 300mm long x 12mm dia. bolt.

4

151

604

... More
Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete. (iii) 300mm x 16mm dia. bolt.

4

231

924

... More
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: (a) With continuous plate base (Hexagonal/ Round rod) (vi) 150 mm grip x 10 mm dia rod.

8

97

776

... More
Supplying, fitting and fixing of false ceiling framework with powder coated exposed G.I. grid suspension system (E-Grid U-1520 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins/ soffit all complete as per the drawing & directions of Engineer-in-charge.

24.3

467

11348

... More
B. Concealed False-ceiling Work -- (c) Supplying, fitting & fixing High Pressure steam Cured Non Asbestos fibre cement designer ceiling board (Density 1300Kg per Cu.m. ) of size595mm X595mm conforming IS 14862 and type B, catagory III of ISO 8336, tested as per AS-1530 Part 3 and BS-476 Part 4,5,6,7 & 8, should be placed in the Grid module to form a false ceiling. All complete as per drawing & direction of Engineer - in- Charge. (Jointing should be done by Elasto jointing compound and top finished with putty as specified by manufacturer.) False ceiling with (ii) 6mm thick Fibre Cement Designer ceiling board.

24.3

469

11397

... More
Supplying, fitting and fixing boiling water proof ply conforming to IS: 710-1977 bonded with phenol formaldehyde synthetic resin conforming to IS: 848-1974 of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in-Charge. (ii) 6 mm 2nd floor

5.05

1150

5808

... More
Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-incharge. In 2nd floor. Glossy/Matt/Suede excluding surface texture or metallic lustre.(i) Thickness of laminate 1.5 mm

8.13

830

6748

... More
(b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.

18.71

38

711

... More
A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. Including using of approved putty etc. on the surface, if necessary : a) On timber or plastered surface : With super gloss (hi-gloss) - (ii) Two coats (white in shade)

13.6

78

1061

... More
Painting with ready mixed red lead paint of approved make and brand : (b) Two coats

73.89

55

4064

... More
Polyurethane Polishing to woodwork with required colour as approved by Engineer-in-Charge with preparing surface including scaffolding and hire charges of compressor machine including cost of filler and hardener material such as P. U. Sealing, P. U. Top coat (Matt/Glossy), Thinner, Spirit etc. and inclusive of all operation, material and labour complete as per direction of Engineer-in- Charge.

13.6

837

11383

... More
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge

100

166

16600

... More
Add GST @ 18% on Rs. 982658.00 i.e total amount over item no. 1 to 42

982658

18

176878

... More
Add Labour Welfare Cess @ 1% on Rs.1159536.00

1159536

1

11595



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.