Public Works Department Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Public Works Department - PWD Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date20 Aug 2024
Closing Date11 Sep 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Busbar section: 500V, 800 Amp capacity 99.9% – 99.5% electrolytic tinned 4 bar Copper bus bar mounted on non-hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification - 1 set. The busbar is to be rigidly supported on suitable non-hygroscopic insulating materials of robust ration to with stand electromechanical stress in the event of earth fault. All connection to bus to made by suitable nuts & bolts. The busbar is too wrapped with coloured PVC (Red. Yellow, Blue & Black) for colour identifications.

-

-

-

... More
Outgoing arrangement: a) 415 V, 250 Amps TPN SFU units with HRC fuses (Make:- L&T/Siemens/ABB/ Schneider) in open exexution.---- 03 nos. b) 415 V 125 Amps TPN SFU units with HRC fuses (Make:- L&T / Siemens/ABB/ Schneider) in open exexution.---- 01 no. c) E.I. Danger Board of suitable size ------- 1 no.

-

-

-

... More
Metering panel: a) Multipurpose Meter Digital Type Load Monitor ( Make L&T/SIEMENS/ABB/ SCHNEIDER) - 1 no. b) Indicating LED Lamp with colour glasses showing (Red/Yellow/Blue/Amber) (Make: Siemens /L&T/ABB/ SCHNEIDER) - 3 sets. (R, Y - 2 sets & R, Y, Amber for ACB On/Off/Trip) c)630/5 Amp ratio C.T (Kappa or equivalent) --- 3 nos. d) Supplying & Fixing 6 Amp SP MCB ---- 9 nos.

-

-

-

... More
Interconnection: All interconnection between incoming main to busbar are to be made with suitable size electrolytic tinned Copper bars or equivalent flexible pve insulated multistranded single core Aluminium cable and the same between busbar to each outgoing mains and & for metering arrangements are to be made by suitable size of Copper with proper socketing of the end of each wire leads.

-

-

-

... More
Earthing: A separate continuous GI earth busbar of size 50mm x 6mm is to be placed at the inside bottom of the panel and run across the full length of the panel board atleast extended for 75 mm at both side end of panel and should have drill hole to fit in 12x50mm GI nut bolt for earth strip connection. The complete panel board is to be spray painted after required surface treatment by 7 tanks process / sand blasting with 2 coat of red oxide primer & 2 coat of finished paint over dried or powder coating.

-

-

-

... More
Installation: The complete panel board is to be installed on suitable brick padestal as directed by the E.I.C. All incoming/outgoing switches is to be properly lebeled on Acrylic sheet as per direction of EIC.

-

-

-

... More
Supplying & fixing 415 V, 415 A TPN SFU with sheet steel enclosure (Make: L&T/Siemens/ABB) on angle iron frame on wall with nuts, bolts etc. incl. S & F 3 nos. DIN type HRC fuse as per rating.

1

-

-

... More
Supply & delivery of following size of 1.1 KV grade, XLPE/PVC insulated Al armoured cable. (Make: Gloster/Polycab/RR Kabel) 4 core 185 sq. mm

85

-

-

... More
4 core 150 sq. mm

175

-

-

... More
4 core 95 sq. mm

50

-

-

... More
Laying of 4 core 185, 150 & 95 sq. mm Al armoured cable in underground trench 460 mm wide x 760 mm average depth with brick protection on the top of the cable with 08 (eight) nos. bricks per mtr. including filling the space between the bricks and cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. [185 for meter room to ACB (85 mtr.), 150 for emergency loads at Old & Annex buildings (205 mtr.) & 95 for ACB to CT scan (25 mtr.)]

260

-

-

... More
Supplying & fixing 100 mm dia medium gauge GI Pipe (ISI-Medium) protection with necessary fittings and jointing metarials as required.

10

-

-

... More
Laying of 4 core 185 sq. mm cable through floor/pavement/wall after cutting floor/pavement/wall and making holes including embedding the cable at an average depth of 100 mm and mending good the damages to original finish including removing the rubbish.

5

-

-

... More
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of following size of XLPE/PVC Al armoured cable. 4 core 185 sq. mm

4

-

-

... More
4 core 150 sq. mm

28

-

-

... More
4 core 95 sq. mm

4

-

-

... More
Finishing the end of following Al armoured XLPE/PVC cable by crimping method incl. supplying and fixing solderless socket (Make: Dowels), tapes, anticorrosive paste & jointing materials. 4 core 185 sq. mm

4

-

-

... More
4 core 150 sq. mm

28

-

-

... More
4 core 95 sq. mm

4

-

-

... More
Laying of 150 & 95 sq. mm cable on wall/surface including S & F MS clamps with earthing attachment in 2 x 10 SWG GI (Hot dip) wire, making holes etc. as necessary, mending good damages and painting. (150 cable - 25 mtr. & 95 cable - 25 mtr.)

45

-

-

... More
Supplying & fixing sheet metal (16 SWG) Iron clad busbar chambers of the sizes: 4 bars, 415 V, 600 A, Dimension of Cu bars (850 mm long) - 4 x (2 x 40 x 5) mm, Dimension of sheet metal box- (500 x 150) mm on angle iron frame on wall, incl. earthing attachment and painting as required. (As per drawing no.- 470 of PWD Specification Book- May, 1991)

0.6

-

-

... More
Supplying and fixing 415 V, 200 A, TPN on load front operated changeover switch (Make: L & T/Siemens/ABB) with sheet steel enclosure on angle iron frame on wall with nuts, bolts etc.

4

-

-

... More
Supplying & fixing 415 V, 200 A TPN SFU with sheet steel enclosure (Make: L&T) on angle iron frame on wall with nuts, bolts etc. including S & F 3 nos. DIN type HRC fuse as per rating.

7

-

-

... More
Supplying & fixing 415 V, 250 A TPN SFU with sheet steel enclosure (Make: L&T) on angle iron frame on wall with nuts, bolts etc. including S & F 3 nos. DIN type HRC fuse as per rating.

1

-

-

... More
Excavation of soil for installation of earth electrode and filling & ramming. (For soft soil)

2

-

-

... More
Earthing with 50 mm dia ISI-Medium GI pipe 3.64 mm thick x 3.04 mtr. long and 1 x 4 SWG GI (Hot dip) wire (4 mtr. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 mtr. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 mtr. below the ground level.

6

-

-

... More
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work (1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe.

6

-

-

... More
Supplying & fixing earth busbar of galvanized (Hot dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.

6

-

-

... More
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.

124

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.