Public Works Department Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Public Works Department - PWD Tender
Electrical and Electronics
Eprocure
Opening Date18 Jul 2024
Closing Date31 Jul 2024
Tender AmountRefer Documents
Costs
EMD
₹ 55,961Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Wbpwdte/ee/bed/niq_102/q Of 2024-25
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WBPWD_716455_1Bid Award Id
ViewTender No
WBPWDTE/EE/BED/NIQ_102/Q of 2024-25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://wbpwd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Avg run 3 mtr
4
-
-
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles.
900
-
-
Cutting Channel of size (31 mm x 31 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 13 mm dia 3 mm thick polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles.
600
-
-
Supplying and Drawing 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS. 3 x (1.5 sqmm)
200
-
-
2x(2.5 sqmm)+1x(1.5 sqmm)
1100
-
-
2x(4 sqmm)+1x (2.5 sqmm)
200
-
-
2x (6 sqmm) + 1x (4 sqmm)
300
-
-
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wall as per GS 200 x 150 x 65
20
-
-
SUB-HEAD --BDB,PDB,VTPN ETC Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. 2+12 Way [Make-Legrand/ L&T/ABB or as per direction of EIC ]
12
-
-
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS. Make - [Make-Legrand/ L&T/ABB or as per direction of EIC ] 6 Way
4
-
-
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS. Make - [Make-Legrand/ L&T/ABB or as per direction of EIC ] 8 Way
4
-
-
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall as per GS [Make-Legrand/ L&T/ABB or as per direction of EIC ] 8 Way ( Up to 160 A )
1
-
-
4 Way ( Up to 160 A ) for lift
1
-
-
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall as per GS [Make-Legrand/ L&T/ABB or as per direction of EIC ] 12 Way ( Up to 160 A )
1
-
-
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS Make - [Make-Legrand/ L&T/ABB or as per direction of EIC ] 40 A DP
12
-
-
63 A FP
8
-
-
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS Make - [Make-Legrand/ L&T/ABB or as per direction of EIC ] 6-32 SP
312
-
-
63 A TP
20
-
-
32 A TP
4
-
-
S & F 32 A 4 Pole 300 mA RCCB with 4 way MCCB Enclosure by cutting wall & mending good the damages as per G.S [Make-Legrand/ L&T/ABB or as per direction of EIC ]
1
-
-
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA in existing Vertical DBs including necessary connection as per GS [Make-Legrand/ L&T/ABB or as per direction of EIC ] 160 A FP
2
-
-
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA in existing Vertical DBs including necessary connection as per GS Make - [Make-Legrand/ L&T/ABB or as per direction of EIC ] 100 A FP
1
-
-
Supplying and fixing 415V, FP Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc as per GS [Make L &T/Havells/Standard] 160 A
1
-
-
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on angle iron frame on wall as per GS.[Make-Legrand/ L&T/ABB or as per direction of EIC ] 315/320 A
1
-
-
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB vertical enclosure with IP-42/43 as per GS [Make-Legrand/ L&T/ABB or as per direction of EIC ] 4/6 /8 /12Way
6
-
-
SUB-HEAD -- SUPPLY & LAYING OF CABLES Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes. Make-RR Kabel / Havells /Gloster or as per direction of EIC 4Core 35 Sq. mm ( for RAW POWER TPN DB & Lift)
240
-
-
4Core 25 Sq. mm ( for Emergency TPN DB & Lift)
160
-
-
4Core 70 Sq. mm
60
-
-
4Core 120 Sq. mm
20
-
-
Laying of cable after cutting floor/pavement/wall as per GS for the following Sizes. 2.5 to 35 Sq. mm
400
-
-
Above 35 sqmm to 95 sqmm
60
-
-
Above 95 sqmm
20
-
-
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. 4Core 35 Sq. mm
12
-
-
4Core 25 Sq. mm
8
-
-
4Core 70 Sq. mm
6
-
-
4Cor 120 Sq. mm
4
-
-
SUB-HEAD -- PLUGS & SOCKETS Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 6 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. as per G.S
20
-
-
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch, 16A Modular switch type MCB as per GS
35
-
-
Supply & Fixing 240 V, 2 nos. 5 A, 3 pin Modular type plug socket with 2 nos. 5 A Modular type switch (Brand approved by EIC), Indicator without plug top on GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc, with connector as per G.S.
8
-
-
SUB-HEAD -FIXING OF LIGHT FITTINGS Fixing only florescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports etc as per G.S
85
-
-
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit as per GS
40
-
-
SUB-HEAD - SUPPLY OF LIGHT FITTINGS Supply of 4 Ft. single/twin LED light fitting for indoor application,complete with all accessories & LED tubes having following Model / Cat No.( Make -Philips / Crompton Greaves / Wipro / Surya or as per direction of EIC aTMC 502 P1xT-LED 22w with 18 master tube.
40
-
-
aTMC 502 P2xT-LED 22w with 2 nos 18 master tube.
45
-
-
S&F 9 W LED light fitting. Make Philips/Crompton/Wipro.
25
-
-
S&F bulkhead light make - vistaglow WT140W LED7S CW PSU S1 PC Make -Philips / Crompton Greaves / Wipro / Surya or as per direction of EIC
10
-
-
SUB-HEAD -- FIXING OF FANS Supply & Fixing 240 V Modular Socket type fan regulator (Step type)(Brand approved by EIC) on existing sheet metal switch board as per GS
40
-
-
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS
40
-
-
Fixing only exhaust fan after making holes in wall as per GS (12")
18
-
-
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall as per GS (12")
18
-
-
Supply & Fixing of 200mm dia PVC decorative ceiling cover plate for ceiling fans
40
-
-
SUB-HEAD -- SUPPLY OF FANS Supply of ceiling fans complete with all accessories having the following Model / Cat No. ( Make -Usha / Crompton Greaves / Orient or as per direction of EIC) a. 1400 mm Sweep (Model- USHA STRIKER)
40
-
-
Supply of Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC/ Orient ) 12"( 300mm ) Speed 920 RPM
18
-
-
S & F 450 mm Wall Fan Tornado Wall II Make -Orient/Usha/Crompton
4
-
-
SUB-HEAD -- MISCELENEOUS S&F OLP-3 incorporated in a box having a 20amp MCB SPN ,compsit flash type 250 V. 6 pin 25 Amp. Plug socket with 25Amp MCB. in the box made of 16 SWG CRC sheet with bakelite top cover and earthing attachment in conceal in wall as per G.S.
10
-
-
S&F sheet metal 2 module Anodised box in conceal in wall incl S & Fbase & top incl S & F 25A capacity 5 pin base & Top North Make and earthing attachment as per G.S.
10
-
-
SUB-HEAD -- EARTHING Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS
18
-
-
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS 4SWG
60
-
-
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS
18
-
-
S & F sheet metal 16 SWG iron clad Busbar chamber on angle iron frame on wall incl earthing attachment as per G.S 4 bar 415V 415 A
1
-
-
Supplly & fixing Medium gauge GI pipe (ISI -Medium) Protection With Necy fitting and jointing materials as required
20
-
-
Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall as per GS
70
-
-
Supply & fixing of GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on wall not exceeding 1100 mm as per GS
360
-
-
S & F Lightning Conductor Air Terminal made of 15 mm dia 1500 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI
(Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. complete duly grouted on the parapet etc. in CC mortar ( 4:2:1)
12
-
-
Making soldered joints between conductor/ conductor & air terminals for 4 SWG stranded GI (Hot Dip) wire incl. supply of jointing materials & painting with 2 (two) coats of Bituminous paint.
12
-
-
Making soldered joints between conductor/ down pipes / other metallic objects for 14 SWG GI (Hot Dip) wire incl. supply of jointing materials & painting with 2 (two) coats of Binous paint .
30
-
-
Supply & Fixing of Testing Joints by 20 mm x 3 mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S&F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as required
12
-
-
Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works. Length upto 0.5 Mtr
12
-
-
Length above 0.5 Mtr
12
-
-
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run
36
-
-
Excavation of soil for installation of Earth Electrode and filling& ramming. For Soft Soil
12
-
-
For Morrum Soil
12
-
-
PART-:- water cooler cum purifier SITC OF GREEN MODEL COOLER CUM PURIFIER WITH EXTERNAL DIAMENSIONS (WxDxH)- 640 X450 X 1350, OPERATING POWER SUPPLY-230 ± 10 % V AC, 50 HZ, RUNNING CURRENT IN AMPS (MAX)-3.2 ± 10 %,POWER IN WATTS-625 ± 10 %,WATER STORAGE TANK CAPACITY-80 LTR,CAPACITY WITH COMFORT LEVEL WATER OUTLET TEMPERATURE AT 17 DEG C-60 LPH,REFRIGENT-R134 22,COMPRESSOR MAKE- EMERSON,THERMAL INSULATION FOR STORAGE TANK-PUF,TOTAL NO. OF FAUCETS-02 (1 NORMAL+1 COLD),WITH 80 LTRS STORAGE CAPACITY, RECOMMENDD MAX WATER FLOW RATE THROUGH THE FAUCETS IN LPM-1.5,NO OF STAGES FOR FILTER CUM PURIIER-03,NO OF PURIFIER CIRCUITS-03,PURIFIER FAULT INDICATION (BUZZER),VISUAL CONTROL (LEDS),WATER FLOW SWITH,10 MINUTES UV AUTO SHUT OFF,STORGE TANK MATERIAL & BODY MATERIAL- FRONT SS 304 & REST PRE COATED STEEL,WORKING WITH -0.4 KG/CC MIN. WATER INPUT PRESSURE AND 2 KG/CC OF MAX. WATER INPUT PRESSURE, INTEGRATED WATER COOLER CUM PURIFIER WITH ENDPOINT PURIFICATION TECHNOLOGY, INCLUDING 1 YEAR WARRENTY AS PER CONDITION. MAKE-EUREKA FORBES/KENT
1
-
-
S & F Iron Guard for water purifier
1
-
-
S & F angle Iron Structure of Suitable Dimension for Fixing 80 ltr water cooler cum purifier on angle iron structure. The height of the angle iron structure must be 1 ft from level
1
-
-
PART-:- Led Flood Light and Allied Works S& F GI water Proof lopping cable box having hinged Gi top cover having 4 mm thick with rubber gasket lining railway type mechanical locking arrange ment earthing terminal with lug etc of the follwing size having of one no 250 v 15A kit kat fuse unit one nl on porcelain insulator where necy. incl painting 200 x 150 x 100 mm
8
-
-
S & F of Led flood lighting luminaire with single die ceramic base high power LED , LED , PDC Housing and Unique flood Optics (NB) to Ensure uniform distribution , maintenance free system, ideal for area lighting Model No- BVP192 LED145 CW NB FG GR PSU Make - Philips / Crompton Greaves / Wipro / Surya or as per direction of EIC
6
-
-
Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make-RR Kabel / Havells /Gloster or as per direction of EIC] 4 Core 10 Sq. mm
30
-
-
4 Core 6 Sq. mm
80
-
-
Laying of cable after cutting floor/pavement/wall as per GS for the following Sizes. 2.5 to 35 Sq. mm
110
-
-
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. 4Core 6 Sq. mm
12
-
-
4Core 10 Sq. mm
4
-
-
Supplying and fixing Timer panel in 2+ 12 way SPN DB . Enclosure The Box shuld comprising following accessorise. A) 230 V , 50 Hz ,16 Amp Single dial 1 x 24 Hrs.Timer ( Microrex QT31 ) of quartz driven running reserve Day dial back up by nickle cadmium battery (Make - GEC / Legrand ) – 1 no B) One no. ML-3 conctractor,(L&T make) with ( 2 NO or 1 NO + 1 NC Aux. Contract ) ( Make - Legrand / L & T ) – 1 no C) 4 pole 32 Amps MCB ( L & T / Ligrand ) - 1 no D) Auto / Manual By pass Toggle Switch arrangement – 1 no. E) 250 V , Diode type neon Indicator lamp ( Make - Legrand / L & T ) – 1 no F) Bakelite base with FP bolt type stud / Terminal block incl S & F Neutral Bar , with spring washer ,nuts etc with this box for termination of power to complete arrangement must be wiring by 4 Sq mm PVC insulated Cu wire with suitable length incl socketing /lugs etc as per requirement & direction of EIC (for controlling outdoor street light fitting fittings)
1
-
-
"Supply and fixing of special type Imported acrylic Letter approx. 50mm thickness flushed in ACP Board made of imported Acrylic ACAST sheet.enclosed . The facia should be made of imported Acrylic ACAST sheet . provision should be as such that Inside each letterHeat sinkable LED lights will glow throughout the letter. S/F of 12'x6'x10"" ACP sheet of 4mm thickness fixed on iron frame, on which the letters will be fixed.The remaining five sides of board also shall be covered with ACP Sheet. The Letters will be as follows:- (matter taken from authority in later)
Installation of the above mention board by expert labour on the suitable size angle grouted in the parapit with suitable size angle iron frame iron angle. Additional arrangement to support the board by iron structure grouted on roof and internal wiring connection as per direction of E.I.C Transportation of the above board ( Kolkata to site location ) incl. unloading and placed to site properly. (NS)
80
-
-
Supplying & Fixing 240V AC/DC Superior Type Ding Dong Call Bell (anchor) on HW Board incl. S&F HW Board
10
-
-
Evaluation Notes How It Works ?
Potential Partner