Public Works Department Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date26 Sep 2024
Closing Date30 Oct 2024
Tender Amount₹ 16,76,068 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Post Constructional Measures :

-

-

-

... More
Post Constructional Measures : Anti-termite treatment to the outside of foundations with chemical emulsion by admixing Imidacloprid emulsifiable concentrates (62ml in 28.5 litre) with includingm cutting shallow channel by excavating soil along and close to the wall face ensuring uniform dispersal of the chemical emulsion to a depth of 300mm. from the ground level by rodding with 12mm. dia. M.S. rod at 150mm.interval in the channel. 1.75 litres of chemical emulsion per metre length shall be used and a balance quantity of 0.5 litres of the chemical emulsion per running metre shall then be used to treat the back fill earth by directing the spray of the imulsion towards the wall surface. The entire work is to be carried out as per specification laid down in para 5.3.1.1 of code IS-6313 (Part-III) 2013

70

4550

65

... More
Anti-termic treatment to the soil under floor with chemical emulsion by admixing Imidacloprid emulsifiable concentrates (72 ml in 34 liters) with water by weight includibg drilling vertically 12mm dia holes at the junction of floor and wall at 30mm interval to reach the soil below using hand operated prresure pump to squirt chemical emulsion into the pump to squirt chemical emulsion into the holes at the rate of one litre per hole. The holes shall be sealed after operation to match with the existing floor. The entire work is to be carried out as per specification laid down at table 1 & in para 5.3.1.3. of Code I.S.-6313 (Part-III)-2023

165.67

12093

73

... More
(d) Anti-termic treatment to the junction of wood work and masonry walls with chemical emulsion by admixing Imidacloprid emulsifiable concentrates (42ml in 20 liters) with water by weight including spraying at the points of contact with the adjoining masonry by drilling 6m dia holes at a downward angle of about 45 degree at the junction of wood work and masonry and squirting chemical emulsion into these holes at tech rate of half litre per hole. The entire work is to be carried out as per specification of in table 1 & para 5.3.1.3 of Code I.S.-6313 (Part-III)-2023. The shutters are to be sprayed with emulsion on both side. All wooden fixtures like almirahs, racks etc. are also to be throughly sprayed with chemical emulsion.

74.89

3744

50

... More
Labour for taking out door and window frame including shutter for repair or replacement of different parts of the frame & refixing the same including mending good all damaes complete. (Concrete and brick work for mending damage will be paid separately) (a) Upto area 2.5 Sq.m

25.46

3029

119

... More
Taking out shutter of door and window, dismantling by parts (for repair or replacement of damaged parts) , reassembling and refitting and rehanging same with old fittings but with new screws as necessary. (Where different parts of same shutter are renewed under different item, payment under item 73 will be made once only).

22.91

2886

126

... More
Taking out heavy iron grated door or window (jail pattern or existing) with locking arrangement after cutting out from walls and refixing the same including mending all damages.[Mending charges to be paid separately]

10.56

2397

227

... More
Taking out heavy iron grated door or window (jail pattern or existing) with locking arrangement after cutting out from walls and refixing the same including mending all damages.[Mending charges to be paid separately]

14.17

5682

401

... More
Easing, oiling and adjusting the steel shutters including scraping all members and fitting so as to make the shutters easily operable (no extra payment will be made for taking out and fixing glass, if necessary).

12

504

42

... More
Renewing knobs of steel window frames including fixing with steel casement by welding or riveting as directed including painting complete

10

330

33

... More
Renewing one point steel (oxidised) handle of steel door and windows as directed including painting complete

10

610

61

... More
Renewing two point steel plated or oxidised handle of steel doors and windows as directed including painting complete

10

660

66

... More
Renewing hinge of steel shutter including taking out old one by cutting and fixing new hinges by welding and mending good damages complete

24

4560

190

... More
Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. (Add extra @ 1.2 % for each additional floors upto 4th floor and @ 1.5% for each addl. Floor above 4th floor.) In Ground floor Flash butt welded windows and ventilators (No shop priming will be allowed to facilitate inspection of workmanship) Without integrated grills.

-

-

-

... More
(b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only]

9.31

20472

2199

... More
(c ) Extra over item no. 33 (a) and (b) for, (iv) Two point nose steel handle including fitting and fixing.

8

400

50

... More
(c ) Extra over item no. 33 (a) and (b) for, (vi) steel peg stay 300 mm long including fitting and fixing.

8

280

35

... More
Taking out M.S. or W.I. Grills from wooden frame including cutting lugs from masonry wall and refitting the same and mending good damages after repairs. (Excluding the cost of necessary repair of damages) or doing any other necessary works

15

1485

99

... More
Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof.

49.7

2485

50

... More
Labour for Chipping of concrete surface before taking up Plastering work

202.64

4255

21

... More
Cleaning the exposed reinforcement preferably upto full diameter by wire brush, applying two coats of polymer based rust removing compound left for 24 hours, removing the coating and then applying two (2) coats of polymer modified anti corrosive protective coating formulated to inhibit the corrosion of reinforcement as per manufacturer's specification] [Mode of measurement:The affected surface area of reinforcement shall be considered for payment]

12.7

9969

785

... More
Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed

1041.81

19794

19

... More
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm

18.34

2186

11927

... More
(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity).

4.91

2911

59257

... More
Cutting chase upto 125 x 150 mm. and subsequent mending of damages. (a) in brick wall [Cement-3.6 Kg/Mtr]

94.2

8101

86

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. a) Pakur Variety

6

30844

5140.77

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (When the height of a particular floor is more than 4 m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (e) for every 4 m or part thereof)

-

-

-

... More
(c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work

92.74

33108

357

... More
f) 25 mm to 30 mm shuttering without staging in foundation

6.54

1327

203

... More
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] M 25 Grade (i) Pakur Variety

29.52

166483

5639.88

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel II. Other than SAIL/ TATA/RINL

1.76

97353

55251.63

... More
Brick work with 1st class bricks in cement mortar (1:6) (b) In superstructure, ground floor

8.73

40883

4683.06

... More
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor

19.96

12325

617.53

... More
Extra for using approved H.B netting in every third layer in 16 & 17 of subhead A above in any floor

19.96

818

41

... More
Removing corroded worn out portion of reinforcement (when the area of bar is damaged by more than 25%) by cutting and replacing the same by a new plain round bar of requisite diameter by binding with required lap / welding with old bar, including cost of reinforcement, complete in all respect including removing unserviceable materials from site as per direction of the Engineer - in - charge. Note : Payment on weight (Kg.) of new reinforcement.

30

2610

87

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]

-

-

-

... More
(i) With 1:6 cement mortar (b) 20 mm thick plaster

558.45

83616

149.73

... More
(i) With 1:6 cement mortar (c) 15 mm thick plaster

436.06

57799

132.55

... More
ii) With 1:4 cement mortar (c) 10 mm thick plaster

165.67

19805

119.55

... More
Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in-Charge prior to execution will be necessary). (Payment to be made on area cleared)

292

3212

11

... More
Cleaning the concrete surface by removing dirt and debris, marking defective locations and removing loose concrete by careful stripping untill hard surface is exposed, cutting the concrete to regular shape, wire brushing the exposed surface and removing debris from site complete as per direction of the Engineer - in - Charge

215.46

19391

90

... More
Applying epoxy based reactive joining agent for joining the old concrete with fresh concrete to be applied within manufacturer's specified time as per manufacturers specification. (0.4 Kg / m² of concrete surface).

63.48

19615

309

... More
a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department]

215.46

18960

88

... More
Polymer concrete made with water resistant bonding agent of synthetic rubber emulsion as per manufacturer's specification excluding the cost of cement concrete (2.75 Kg / bag of cement) Note : Payment on volume of (1 : 1½ : 3) Concrete.

14.56

64098

4403

... More
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats

825.94

57815

70

... More
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor: (a) One Coat

436.06

13692

3140

... More
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) b) Premium 100% Acrylic Emulsion

436.06

36629

84

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes. Pakur variety

1.27

5969

4702.23

... More
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches

49.13

1179

24

... More
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.

139.51

4570

32.76

... More
M.S. works in framed gratings of window etc.made of round or square bars and frame work or M.S. flats (with the bars securely fixed to the flat bar frame) with or without intermediate flat bar stiffener and fixed with necessary screws etc. complete, as directed. In ground floor

1.83

16181

8823

... More
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials

8.75

11410

1304

... More
(A) Supplying fitting and fixing door frame with M.S. angle as per drawing & direction of required section.The holes for counter sunk machine screw & nuts will be such as to fit 8 to 10 mm Iron screw. The counter sunk nut to be welded . The nuts are to be welded after careful checking with screw.All welding spots should be properly filed or rounded smooth including cost of welding hinges for hinge cleats , lugs for hasp bolt, socket bolt etc. and necessary M.S. clamps of 25mm x 6mm flat 225mm long as per direction welded to the frame fitted and fixed in position excluding cost of concrete

175.28

13846

79

... More
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (d) Sal : Local.

0.38

27649

72954

... More
Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. In ground floor. (In case of non-supply of single plank, penal rate of reduction of 20% will be made) (iii) 35mm thick shutters with 19mm thick panel of size 30 to 45 cm. (b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak.

11.55

32212

2789

... More
Styles and rails of wooden shutters fitted and fixed complete. (Payment to be made on area of new work only). In Ground Floor: (ii) 35mm Thick shutter. (b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak

3.56

7753

2178

... More
Panel (made of single plank) of door and window shutters to design as directed: In Ground Floor (Payment to be made on area of exposed new work). (In case of non-supply of single plank penal rate of reduction to a maximum of 30% will be made). (ii) 19mm thick panel of 30cm to 45cm width (b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak.

4.31

4818

1118

... More
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.

105.06

3046

29

... More
(b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc

95.9

3644

38

... More
A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :

-

-

-

... More
(b) On steel or other metal surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)

105.06

8299

79

... More
(a) On timber or plastered surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)

95.9

7767

81

... More
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.

-

-

-

... More
(A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (b) Area of each tile upto 0.09 Sq.m (ii) Other than Coloured decorative including white

182.23

124359

682.43

... More
B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a) Area of each tile upto 0.09 Sq.m (i) Coloured decorative

43.68

31905

730.43

... More
Welding in M.S. structural work with gas or electric:

-

-

-

... More
(a) Tack weld

120

1080

9

... More
(b) Continuous weld.

395.64

3560

9

... More
Iron parliamentary hinges conforming to IS 362-1982 fitted and fixed complete with steel screws. (c) 75mm. X 100mm. X 20mm. X 2.24mm

36

2916

81

... More
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.

-

-

-

... More
(v) 75mm. X 60mm. X 3.15mm.

32

1504

47

... More
(viii) 100mm. X 75mm. X 3.50mm

40

2640

66

... More
Renewing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. In cement concrete(1:2:4) including cutting of brick work/concrete work as per direction. (Cost of concrete will be paid separately ) (c) 40mm X 6mm, 125mm Length

112

4256

38

... More
Iron socket bolt of approved quality fitted and fixed complete

-

-

-

... More
(e) 300mm long x 10mm dia bolt.

12

1140

95

... More
c) 150mm long x 10mm dia bolt.

24

1512

63

... More
A) Iron door ring of approved quality fitted and fixed with nut and washer complete. (ii) 75mm dia.

24

672

28

... More
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: (a) With continuous plate base (Hexagonal/ Round rod) (vii) 150 mm grip x 12 mm dia rod.

8

888

111

... More
Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria.. (i) 66mm x 90mm

19.8

9840

497

... More
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. In ground floor. (i) 32 mm thick

2.4

6631

2763

... More
Supplying, fitting and fixing hinge cleat in position excluding the cost hinge and other fiffitngs. b) with 75mm iron Butt-hinge ii) Sal : Malayasian

24

864

36

... More
Renewing 125mm long wooden buffer block ii) With Sal : Malayasian

24

1224

51

... More
i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. (c) 300mm long.

10

1660

166

... More
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge

48.1

7983

166

... More
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.

-

-

-

... More
A) UPVC Pipes (ii) 110 mm. Dia.

7

1757

251

... More
B) UPVC Fittings: a) Plain Tee (ii) 110 mm. Dia.

2

344

172

... More
B) UPVC Fittings: c) Bend 87.5 degree (ii) 110 mm. Dia.

2

320

160

... More
B) UPVC Fittings: d) Shoe (ii) 110 mm. Dia.

2

222

111

... More
Uprooting and removing plants from the surface of walls parapet etc and making good damages. (Repairing of damages to be paid separately).

-

-

-

... More
(a) Small plant

25

1250

50

... More
(b) Medium size plant

7

420

60

... More
Sanitary & Plumbing Works:- Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. (i) 450 mm X 300 mm size

2

3958

1979

... More
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately). (a) For Exposed Work PVC Pipes

-

-

-

... More
(Dia) 15 mm

8

808

101

... More
(Dia) 25 mm

20

3540

177

... More
(Dia) 32 mm

28

6608

236

... More
(Dia) 40 mm

7

2044

292

... More
Supplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreous china ware of approved make complete in position with necessary bolts, nuts etc. (a) With 'P' trap (with vent)

1

3104

3104

... More
Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding 'P' or 'S' trap (excluding cost of concrete for fixing). (i) 580 mm X 440 mm

3

4839

1613

... More
Supplying, fitting and fixing Squating plate with integral flushing in white vitreous chinaware of approved make in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid seperately). (i) 450 mm X 350 mm

1

881

881

... More
Supplying, fitting and fixing shower of approved brand and make

-

-

-

... More
(f) Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar).

2

2502

1251

... More
(g) PTMT overhead shower ( Prayag or equivalent) (ii) 150 mm round

2

680

340

... More
Supplying, fitting and fixing bib cock or stop cock. e) PTMT (Polytetra Bib Cock / Stop Cock ( Prayag or equivalent) 15 mm

20

3080

154

... More
Supplying, fitting and fixing towel rail with two brackets. (a) C.P. over brass (ii) 25 mm dia. and 600 mm long

4

1720

430

... More
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992

-

-

-

... More
(A) (i) Single Socketed 3 Meter Length (b) 110 mm

20

5840

292

... More
(B) Fittings (ii) Plain Tee (b) 110 mm

2

170

85

... More
(B) Fittings v) Plain Y (b) 110 mm

2

412

206

... More
(B) Fittings vi) Door Y (LH) & (RH) (b) 110 mm

2

552

276

... More
(B) Fittings xvi) Pipe Clip (b) 110 mm

2

42

21

... More
(B) Fittings xv) Vent Cowl (b) 110 mm

2

66

33

... More
Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin-charge. (Payment will be made on centre line measurement of the total pipeline including specials. (B) Under ground (ii) 110 mm dia.

20

1680

84

... More
Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia (iii) 600 mm long

6

642

107

... More
Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete. i) Polythene Flush Pipe

4

620

155

... More
Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm

2

1226

613

... More
Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. (a) E.W.C. (b) Anglo Indian (ii) Plastic (hallow type) white

1

485

485

... More
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only).

-

-

-

... More
(vi) 32 mm dia

2

2320

1160

... More
(vii) 25 mm dia

2

1556

778

... More
Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007 (A)(I) CPVC Pipes Class-1,SDR-11

-

-

-

... More
(Q) Ball Valve (Dia) 20 mm

2

304

152

... More
(Q) Ball Valve (Dia) 25 mm

2

478

239

... More
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc

4

4060

1015

... More
Supplying, fitting and fixing pillar cock of approved make b) PTMT Pillar Cock - 15 mm. (Prayag or equivalent).

2

444

222

... More
Supplying, fitting and fixing C.I. bracket including two coats of painting e) Aluminium brackets

4

312

78

... More
Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps. (iii) 900 mm long

2

150

75

... More
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (b) 1000 litre capacity

1

5128

5128

... More
Labour for hoisting plastic water storage tank (i) Upto 1500 litre capacity. (a) Upto 1st story from G.L

1

96

96

... More
Labour for punching hole in plastic water storage tank upto 50 mm dia.

3

57

19

... More
Dismantling Indian W.C. including taking out base concrete as necessary

3

135

45

... More
Supplying, fitting and fixing in position R.C.C. Manhole/ pit cover of approved make with rim of approved make (Heavy type) (ii) 560 mm dia.

4

1352

338

... More
Cleaning silt of inspection pit.

2

308

154

... More
Removing sludge from septic tank, soak well etc. by methor labour including disposal of the same outside the compound as directed. (a) Upto 20 users:-(ii) Beyond a lead of 150 metre and outside the Municipal limit

2

4318

2159

... More
Cleaning soak pit by removing the top slab and replacing inner filling with jhama bats and repairing the pit as necessary including fitting the slab.

2

2694

1347

... More
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. i) With Pakur variety Other manufacturing

2

12756

6378.01

... More
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia

1

14461

14461.75

... More
Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,Part- I.Payment will be made separetly on the basis of actual height based on relevant I.S.Code

1

43274

43274.45

... More
Sub Total for item no. 1 to 98

1

1406333

1

... More
Add 18% extra in respect of GST on all items on Sub-Total

1406333.2

253140

18

... More
Add 1% extra in respect of Labour Welfare Cess on (sub total + GST 12%)

1659473.2

16595

1



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.