Public Works Department Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Public Works Department - PWD Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date14 Aug 2024
Closing Date5 Sep 2024
Tender AmountRefer Documents
Costs
EMD
₹ 19,800Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WBPWD_734584_1Bid Award Id
ViewTender No
WBPWD/EE-KED/eNIQ-23Q/24-25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://wbpwd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Providing on hire basis main wiring with 1.1 KV grade Aluminium Conductor PVC / XLPE armoured cable of following size including laying in trench (at least 230 mm below ground) including socketing and necessary finishing as required and dismantling the same and mending good the damages.((Hiring upto 45 days)
-
-
-
4C X 50 Sqmm cable
900
-
-
4C X 16 Sqmm cable
2700
-
-
Providing on Hire basis 500V TPN MS with rewirable fuse/HRC fuse fixed on angle iron frame incl providing necy inter connection wiring, 2 nos of earthing attachment and dismantling as directed by EIC after the programme (Hiring upto 45 days)
-
-
-
440V, 100 A
25
-
-
Providing on hire basis 500 V , 100Amp 4 Pole MCB isolator as incomer with 32Amp or 16 Amp per way, 6 Way TPNMCBDB with all arrangement in a outdoor type pillar box incl interconnection wiring , 2 nos of earthing attachmentwith proper socketing and dismantling as direcyted by EIC after the programme(Hiring upto 45 days)
30
-
-
Providing on hire basis 500V, 100A on load change over switch on angle iron frame erected on the ground / wall with necessary support incl. interconnection wiring,2 nos of earthing attachment socketing,& dismantling the same after completion of the program.(with PWD / E.I.C. approved materials)(For 03 days)
11
-
-
Providing and Fixing on hire basis following LED Flood light fittings complete with all accessories and dismantling as directed by EIC after the programme.(Hiring upto 45 days)
-
-
-
Minimum 200 Watt LED Flood fittings.(Crompton/Philips/Bajaj/Opple/Nordusk)
750
-
-
Supplying & providing on Hire basis 1 no Seperate 6 amp plug and Switch with 150X100X65mm MS/TW switch Board including necy. wiring in 3 x1.5 sq mm single core PVC insulated, unsheathed, multistrand copper wire (avg. Length 5 mtr) & dismantling the same after completion of the program.
70
-
-
Supplying & providing on Hire basis 1 no Seperate 20 amp plug and Switch with 150X100X65mm MS/TW switch Board including necy. wiring in 3 x 2.5 sq mm single core PVC insulated, unsheathed, multistrand copper wire (avg. Length 5 mtr) & dismantling the same after completion of the program.
20
-
-
Supplying & Providing on hire basis 415V, 3 Phase CPCB approved soundless diesel generator set for prime/standby operation with mobil incl. transportation ,one operator & appropriate size of cable upto 120 Mtrs including necessary interconnection, socketing & dismantling as directed by EIC after the program. If the DGs are not placed at site on time , pro rata rate will be reduced from bill.
-
-
-
25 KVA-10 Sets
3
-
-
Supply and pouring of HSD for the hired DG set incl. handing cost.(The measurement will be done after considering all technical aspect,orginal invoice & log book)
880
-
-
Supply & providing on hire basis Earthing with 50 mm dia GI pipe 2.5 to 3 mtrs long and 6/8 SWG GI wire with galvanized nut and bolts washer etc. below the ground level & dismantling the same.((Hiring upto 45 days)
80
-
-
Deployment of 1 no. Skilled Electrician, & 1 no. Helper per shift per day (for 2 shift per day i.e. Total 2 nos Electrician & 2 nos Helper per day for 2 PM to 6 AM Hrs) for carrying out all kind of EI operation, maintenance & proper upkeepment
45
-
-
Transportation charge for the materials from Company's godown to Site and return back to godown after use.
1
-
-
Special Terms and conditions for Temporary E.I. Work - 1) Earthing should conform to IS specification. Earth Continuity wire should not be broken / Jointed. Single Earth continuity wire should be used from Earth Bus-Bar to the installation.
2) Main Electrical Panel Should be earthed by two nos. of separate earthing.
3) MCB / Rewirable Fuse type Distrubution Board should be installed with proper Trip Current setting / fuse wires. However, MCB type DBs are preferable.
4) No Part of the Electrical Circuit in the pandal / Structure shall be within 12 inches of any decorative cloth / paper.
5) Ordinary Flexible wires should not be used. Only new PVC insulated & sheathed wires (Bearing ISI mark) or PVC insulated wires of FRLS (Fire Resistant Low Smoke) type (ISI Marked) are allowed.
6) All cable ends should be properly sockedted.
7) All joints shall be made with porceline insulated connectors. Twisted & lapped joints shall be avoide. But Joints are strictly not allowed in the dias.
8) Cables / Wires should run along outside the Dias.
9) Ceiling fan (s) / Electrical fittings must not be suspended from the ceiling of Dias. Pedestal fans are not allowed on the Dias. However, Pedestal fans may be installed outside dias, but the body of the fan must be properly earthed.
-
-
-
10) T/L fittings shall be of box type (Indoor commercial type). Any kind of open type fittings must be avoided.
11) Each A.C. Machine should be connected with a separate circuit and earthing should be provided by separate single earth contunuity wire from Earth Bus-bar.
12) P.A. System and Microphone shoud be earthed.
13) Sufficient quantity of Fire Extinguishers and First Aid Box should be provided.
14) If the DGs are not placed at site on time pro rata rate will be reduced from bill.
15) The guarding /security arrangement of all the hired products /installation has to be made by the successful bidder at his/their own cost and responsibility. No additional charge will be paid for any unwanted incidents like theft, damage due to natural calamities or any other reasons whatsoever.
16) During entire hiring period any fault to the hired installation shall be rectified/faulty items replaced, at the cost of agency. Suitable man power for attending and rectification/replacement of damaged items has to be provided by the agency at their own cost. Rectification time is 1 hour for the event day and upto 2hrs for other days.
17) A test certificate cum safety certificate is to be provided by the agency, duly signed by the Supervisor of the agency after completion of installation.
18) A performance guarantee of hired DG sets and AC machines has to be provided by the agency after completion.
-
-
-