Public Works Department Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Public Works Department - PWD Tender
Electrical and Electronics
Eprocure
Opening Date11 Nov 2024
Closing Soon26 Nov 2024
Tender AmountRefer Documents
Costs
EMD
₹ 37,897Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Supply Installation Of Flood Light For Illumination Of Sea Side In Front Of Sea Beach At Digha
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WBPWD_768252_1Tender No
WBPWD/EE/PMED/NIQ-65/2024-25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://wbpwd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Erection of HDG Octagonal pole muffing with cement concrete square foundation made with stone chips, PCC-100mm(1:3:6) of base block RCC(1:1.5:3), size (0.609×0.609×0.461mtr) below ground level. And upper portion size 0.406×0.406×1.22mtr. The hole concrete foundation made with 10mm dia, TMT Bar 0.15mtr apart(Horizontally & Vertically) cage structure. The muffing should be 0.304mtr above the ground level incl. 1.5mm thick neat cement finish upto 0.762mtr. from top level. 04 nos. 20/25mm dia 1.67mtr. length GI FDN Bolts with Nuts inside the muffing with 10mm thick base plate by welding accordingly matching with the HDG pole base plate hole. incl. 02nos 30mm dia polythene pipe inside the center of muffing for passing 02 nos cables.
6
-
-
Supply of 500 W Led Flood Light Lumen Efficacy
130, CRI70, CCT-5700K, IP- 66, IK-08, Aluminum Dia
Cast Housing, with secondary Lens9Beam angle (25 degree +- 10 %), Toughened Glass, Potted driver. Inbuild Surge Protection 4kv Internal & 10 kv external LM 79 Report shall be provided from manufactures own NABL Lab and LM 80 from Nichia/Osram/Seoul/Bridge Lux 5 Years Warranty
Make – Bajaj /Phillips(Signify)/Lighting Technology (LT)
32
-
-
Supply & Fixing of outdoor type feeder pillar Box with concrete foundation 2.5ft (above GL) and 1ft (below GL), made of 5mm (4 SWG) hot dip galvanized GI Sheet coated with permanent gray paint and suitable size, double door on both side with hinged operation & locking arrangement with proper ventilation and the provision for suitable fixing arrengement & connection with suitable size Cu wire as reqd. of the following: INCOMER: (a) S&F of 415V, 125A TPN SFUwith sheet steel enclosure on flat iron/angle iron frame with nuts bolts etc incl. S & F 3 nos. 200A DIN type HRC fuse as per rating.l (MakeL & T ) (MakeL & T )-1no. (b) 500V 300A capacity 4 bar copper busber chamber made of 16 SWG CRCA sheet compring with 4 nos 300A capacity eletrolytic tinned copper ber supported on nonhygroscopic insulating chair.-1 set. OUTGOING
(a) S&F of 415V 63A TPN SFU with sheet steel enclosure on flat iron/angle iron frame with nuts bolts etc incl. S & F 3 nos. 63A DIN type HRC fuse as per rating.l (MakeL & T ).-2 no. (b) 4 pole 63 A power contactor- 1 no.
(c) Time Switch L&T ASTRO Mini- 1 no. d)415V DIGITAL VOLTMETER WITH SELECTOR SWITCH- - 1 set . e)415V DIGITAL AMMETER WITH SELECTOR SWITCH- 1 set f) 100/5 A CT- 3 nos. g) 63A 415V AUTO MANUAL SELECTOR SWITCH- - 1 set
(h) S&F 230V R,Y,B LED indicator lamp with 6A MCB on din rail. (i)E.I danger board-1no.
1
-
-
Supplying of 1.1 KV Grade XLPE Aluminium conductor, PVC sheathed, armoured cable conforming to IS 7098, of earthed system of following size. [ Make : Polycab / Havells / RR Kabel ]
-
-
-
4 core 16 sqmm
600
-
-
Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core
600
-
-
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 4 core 16 sqmm
12
-
-
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 4 core 16 sqmm
12
-
-
Cement Concrete road cutting avg. dept. 1.5 ft x avg. width. 1.5ft including mending finishing good damages to original finish concrete floor by net cement concrete.
600
-
-
Inter connection of compound light fittings by 4 x 4 Sq. mm. PVC insulated copper wire ( Finolex/Polycab/Havells)from loop box inside the pole to light fittings through pole & bracket with Pricision MMS PVC pipes as per direction of EIC
100
-
-
Supply & fixing 80 mm dia HDPE and laying along the pavement as per direction of E.I.C.
600
-
-
Earthing with 50 mm dia GI pipe (ISI-Medium)x 3.0 Mts. long and 1 No. 65 mm x 8 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 80 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
10
-
-
Connecting the equipments body to earth busbar incl. S & F 25 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc.
30
-
-
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil
30
-
-
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
-
-
-
Solid GI wire No 4 S.W.G wire
50
-
-
masonery enclosure on the top of the earth chamber of overall size 600 mm x 600 mm x 300 mm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cement cover of size 600 mm x 600 mm x60mm.
10
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%