Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Public Works Department - PWD Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date13 Aug 2024
Closing Date3 Sep 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Sitc Of Glow Sign Boards And Repairing Works Of Existing Internal Electrical Installation At Office Building, Hatchery Building Including E.i. Works At Newly Constructed Grower House Inside The Campus Of State Poultry Firm, Nimpith, Jaynagar-ii Bloc

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying and fixing 415V. TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc.. (L&T/ Siemens)

-

-

-

... More
160 A.

1

-

-

... More
Supplying and fixing sheet steel (16SWG) cable end box on TPN SFU enclosure/ Change Over enclosure with nuts bolts etc. incl. powder coated painting.

-

-

-

... More
200 A.

2

-

-

... More
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (L&T/ Siemens)

-

-

-

1

-

-

2

-

-

... More
Supplying and fixing of double door VTPN MCB DB with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. necy. inter-connection as per GS. 4 way- 1 no. 415 V., 63 A. FP MCCB (Input) & 3 nos. 415 V., 32 A. TP MCBs, 3 nos. 240 V., 6-32 A. SP MCBs as required (Make-Legrand). (for Office Building & Hatchery Building).

2

-

-

... More
Supplying and fixing of double door Horizontal TPN MCB DB with IP-42/43 protection, concealed in wall incl. necy. connection as per GS. 4 way- 1 no. 415 V., 32 A. FP MCB & 12 nos. 240 V., 6-32 A. SP MCBs as required (Legrand/ Siemens/ L&T).

4

-

-

... More
Supplying and fixing of double-door SPN MCB DB with IP-42/43 protection, concealed in wall incl. necy. connection as per GS. (Legrand/ Siemens/ L&T).

-

-

-

... More
2+10 way Enclosure - 1 no. 240 V., 32 A. DPMCB & 10 nos. 240 V., 6-16 A. SPMCBs as required.

6

-

-

... More
2+6 way Enclosure - 1 no. 240 V., 25 A. DPMCB & 6 nos. 240 V., 6-16 A. SPMCBs as required.

1

-

-

... More
S&F of 415 V., 40 A. DIN rail type FP MCB ("C" Curve and 10 kA breaking capacity) (L&T/ Legrand) with 32 A. Rotary type 1 pole 3 way Swlector Switch (L&T/ Legrand) on Supplying and fixing 4 Way MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. (for Freezes at Hatchery Building).

5

-

-

... More
Supplying & fixing of 0.6 mtr. long sheet metal (16 SWG) Iron Clad Busbar chambers, consisting with 4 nos. Copper Bars (15 mm x 3 mm) on suitable porcelain insulator for 125 A. current (per phase) on angle iron frame on wall, incl. earthing attachment and painting as required – (As per Drawing no. 470 of PWD Specification Book – May 1991). (for Freezes at Hatchery Building).

2

-

-

... More
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (approved make) partly in 20mm size PVC rigid conduit 'FR' (Brand approved by EIC) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed] (for new Grower House, Hatchery Building & Panel Room etc.)

-

-

-

... More
Average run 8 mtr

34

-

-

... More
Average run 10 mtr

12

-

-

... More
Distn. wiring in 3x1.5 sqmm single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to 240 V. 5A. 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish. i. On Board

9

-

-

... More
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with (Make-Legrand Myrius/Honey Well/Anchore Roma Urban) Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed] (for Office Building)

-

-

-

... More
Average run 8 mtr

62

-

-

... More
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) (Make-Legrand Myrius/Honey Well/Anchore Roma Urban) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] [For new Toilet block.]

-

-

-

... More
Average run 6 mtr

3

-

-

... More
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed] [For new portion of Office building].

-

-

-

... More
Average run 6 mtr

5

-

-

... More
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to 240 V., 6 A., 5 pin plug point incl. S&F 240 V., 6 A., 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish. On Board.

13

-

-

... More
S&F PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required as per GS.

-

-

-

... More
20 mm dia

600

-

-

... More
25 mm dia

8

-

-

... More
Cutting channel of 31 mm x 31 mm/ 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire fish wire incl. mending good damages to building works.

-

-

-

... More
13 mm dia 3 mm thick polythene pipe without earth continuity wire

70

-

-

... More
19 mm dia 3 mm thick polythene pipe without earth continuity wire

180

-

-

... More
Supplying and Laying 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid pipe and making necy. connection as required.

-

-

-

... More
3 x 1.5 sq.mm. (for Sep. 6 A. points, From Loop Boxes to LED Outdoor Light fittings & others)

140

-

-

... More
2 x 2.5 sq.mm. + 1 x 1.5 sq.mm. as ECC (for Combined Boards, Computer Boards, Sep. 16 A. Power Boards & Exhaust Fans at new Grower House)

658

-

-

... More
2 x 4 sq.mm. + 1 x 2.5 sq.mm. as ECC (For A.C. Machines)

150

-

-

... More
4 x 4 sq.mm. + 2 x 2.5 sq.mm. as ECC (For Input of Freezes at Hatchery Building).

12

-

-

... More
2 x 10 sq.mm. + 1 x 4 sq.mm. as ECC (For SPN DBs)

115

-

-

... More
4 x 10 sq.mm. + 2 x 6 sq.mm. as ECC (For TPN DBs)

70

-

-

... More
4 x 10 sq.mm. (from Main switch to TPN DB at new Grower House)

4

-

-

... More
4 x 25 sq.mm. (From Meter to Cut Outs)

4

-

-

... More
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.

-

-

-

... More
1.5 sq.mm. - N.S.

500

-

-

... More
2.5 sq.mm.

400

-

-

... More
4 sq.mm.

80

-

-

... More
6 sq.mm.

12

-

-

... More
10 sq.mm.

32

-

-

... More
25 sq.mm.

8

-

-

... More
S&F of 240 V., 6A. plug socket with Piano key type switch (Anchor-Penta) - 1 set and 240 V., 20A. plug socket with separate 20 A. Piano key type switch (Anchor-Penta) - 1 set on sheet metal switch board embedded in wall incl. S & F 200x150x65 mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.

3

-

-

... More
Supply & Fixing 240 V, 20 A Piano key type switch (Anchor-Penta) on sheet metal switch board incl. S & F 100x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. (for Exhaust Fans at new Grower House).

1

-

-

... More
Supply & Fixing 240 V, 20 A Piano key type socket (Anchor-Penta) on sheet metal switch board incl. S & F 100x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. (for Freezes at Hatchery Building).

5

-

-

... More
S&F of 240 V., 20A., plug socket with separate 20 A. Piano key type switch (Anchor-Penta) - 2 sets on sheet metal switch board embedded in wall incl. S&F 200x175x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.

4

-

-

... More
S&F of 240 V., 3 nos. 6 A. socket with 3 nos. 6 A. Piano key type switch (Anchor-Penta), switch type indicator & 10 A. switch type SP MCB (Anchor Penta) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. (Combined Board).

8

-

-

... More
Supply & Fixing 240 V., 20A. plug socket with separate 20 A. Piano key type switch (Anchor-Penta) - 1 set on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required (near Panel Area)

3

-

-

... More
Supply & Fixing 240 V., 20 A./ 25 A., Modular type starter (Brand approved by EIC) with 16-25 A. Modular switch type SP MCB (C-Curve), 1 no. Blank Plate and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall (Make-Legrand Myrius/Honey Well/Anchore Roma Urban) incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.. (for AC points at Office Building)

4

-

-

... More
Supply & Fixing 240 V., 25 A., 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall (Make-Legrand Myrius/Honey Well/Anchore Roma Urban) and making necy. connections with PVC Cu wire and earth continuity wire etc.. (for AC Machines)

6

-

-

... More
Supply & Fixing 240 V., 25 A., 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. (for AC Machines) (Make-Legrand Myrius/Honey Well/Anchore Roma Urban)

6

-

-

... More
S&F of 240 V. 6 A. 3 pin Modular type plug socket (Make-Legrand Myrius/Honey Well/Anchore Roma Urban)) with 230 V., 6 A. Modular type switch, without plug top - 2 sets on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections as per GS. (at Office Building)

4

-

-

... More
S&F 240 V., 6 A. 3 pin Modular type plug socket (Legrand-Myrius/ Cabtree) with 6A Modular type switch, without plug top - 3 sets and 240 V., 16 A. 3 pin Modular type plug socket with 16A Modular type switch (Legrand-Myrius/ Cabtree) without plug top - 1 no. and 230 V., 10 A. Modular switch type SP MCB (C-Curve) and Indicator and 4 nos. Blank Plates on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections as per GS. (Computer Board at Office Building).

14

-

-

... More
S&F 240 V., 6 A. 3 pin Modular type plug socket (Legrand-Myrius/ Cabtree) with 6A Modular type switch, without plug top - 1 set and 240 V., 16 A. 3 pin Modular type plug socket with 16A Modular type switch (Legrand-Myrius/ Cabtree) without plug top - 1 no. on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections as per GS. (Power plug point at Office Building).

4

-

-

... More
S&F sheet metal inspection box (16 SWG) of the following sizes flushed in wall after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works.

-

-

-

... More
300 mm x 200 mm x 65 mm

4

-

-

... More
240 mm x 200 mm x 65 mm

7

-

-

... More
200 mm x 150 mm x 65 mm

11

-

-

... More
175 mm x 100 mm x 65 mm

6

-

-

... More
150 mm x 100 mm x 65 mm

6

-

-

... More
Supply & Fixing bakelite / perspex top cover on existing Inspection board by Brass screws.

-

-

-

... More
300 mm x 200 mm x 65 mm

4

-

-

... More
240 mm x 200 mm x 65 mm

7

-

-

... More
200 mm x 150 mm x 65 mm

11

-

-

... More
175 mm x 100 mm x 65 mm

6

-

-

... More
150 mm x 100 mm x 65 mm

6

-

-

... More
S&D of 4' long twin LED Tube light fitting with complete accessories & 2 nos. 230V. 18 W. PC body T-LED Tubes. (Philips - TMC 501 P 2xT-LED 22W P3242 and 2 nos. Mas LEDTube 1200mm 18W865 T8 I – 2100lm/ CG - IGP162 LT8-16 2 x T8 and 2 nos. LTB-20-865-(2)/ Bajaj)) with 3 years warrenty.

30

-

-

... More
S&D of 4' long single LED Tube light fitting with complete accessories & 1 no. 230V. 18 W. PC body T-LED Tube. (Philips - TMC 501 P 1xT-LED 22W P3241 and 1 no. Mas LEDTube 1200mm 18W865 T8 I – 2100lm/ CG - IGP161LT8-16 1 x T8 and 1 no. LTB-20-865-(2)/ Bajaj)) with 3 years warrenty.

32

-

-

... More
Fixing only single/twin Tube light fitting complete with all accessories Directly on wall/ceiling with suitable size MS fastener, Ceiling plate, nipples etc. as required.

10

-

-

... More
Fixing only single/twin Tube light fitting suspended 25 cm below the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts as per GS. incl. necy. connection by 2 x 1.5sqmm. flexible copper wire of 1.10 mt. length.

52

-

-

... More
Supplying & Fixing MS fan clamp of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)

7

-

-

... More
Supply & Fixing Socket type fan regulator (Step type) (Anchor-penta make) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.

9

-

-

... More
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.

16

-

-

... More
Supply & delivery of 1200 mm sweep 230 volt AC Ceiling fan incl. Blades, canopy etc. With 18" down rod(14SWG), Fork(10SWG), Heavy type insulator, 3/8th inch bolt with nut, heavy type split pin etc.with safety wire & PS2 type capacitor, as directed by EIC. [Make-Orient - Summer cool (1200 mm Metalic Bronze Copper) or similar spec of Crompton/Usha - Striker 1 Star (Safety Wire & S3/P2 Capacitor)]

25

-

-

... More
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod and making necessary connection by 2x1.5 sqmm flexible copper wire.

25

-

-

... More
S&F of 230 V. 9 W pin type (B22) LED bulb (Philips/ CG/ Bajaj - 830052) on existing Angular Holder.

6

-

-

... More
S&D of following dia & RPM Heavy duty exhaust fan with complete accessories like blades etc. with 3 years warrenty. (Make: E.P.C./ CG).

-

-

-

... More
9" dia Exhaust Fan with 1370 RPM

4

-

-

... More
15" dia Exhaust Fan with 1420 RPM

8

-

-

... More
Fixing only following exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as required and providing necy. length of PVC insulated wire and making connection as per GS.

-

-

-

... More
9" dia Exhaust Fan

4

-

-

... More
15" dia Exhaust Fan

8

-

-

... More
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long). For Al. - 9" dia Exhaust Fan

4

-

-

... More
S&F of GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh with good quality net at bottom on wall by necy. bolts & nuts (6 mm dia x 62 mm long).

-

-

-

... More
15" dia Exhaust Fan

8

-

-

... More
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board.

2

-

-

... More
S&D of 230 V., 10 W. outdoor type LED bulkhead light fittings with 2 years warrenty. (PHILIPS - WT202W LED6S CW PSU S2 PC/ CG - LBHP-10-CDL).

1

-

-

... More
Fixing only bulk head light fitting on wall /ceiling by screws etc.

1

-

-

... More
S&D of 230 V., 10 - 14 W. LED Mirror light fittings incl. all accessories with 2 years warrenty. with 2 years warrenty. (Philips - 31165/CG - LCL-14-CDL).

2

-

-

... More
Fixing only Mirror light fitting on wall by screws etc. as required incl. necessary connection as per GS.

2

-

-

... More
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil.

14

-

-

... More
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GI pipe.

12

-

-

... More
Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts.. (For Panel Portion)

2

-

-

... More
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe

2

-

-

... More
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar as per GS.

2

-

-

... More
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required

0.6

-

-

... More
Connecting the equipments to earth busbar including S & F following size GI (Hot Dip) wire on wall/floor with staples buried and making connection to equipments as per GS.

-

-

-

40

-

-

... More
10 SWG

60

-

-

... More
Connecting the equipments body to earth busbar incl. S & F 50 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc.

10

-

-

... More
S&F of suitable size of timer box, consisting with 1 no. 230 V. 16 A. DP MCB, 2 nos. 20 A. 2 pole Power contactor, 1 no. 230 V., 6 A. SP MCB, 1 no. 10 A. toggle switch, 1 no. Digital timer clock, 1 no. 20 A. selector switch for giving output selection at the time of manual operation, 3 nos. Inditating lamps etc. incl. suitable size of interconnecting wires (power line drawn by 4 sq.mm. copper wire & control & indicating circuit drawn by 1.5 sq.mm. copper wire with copper sockets) as reqd. as per direction of E.I.C.. (for A.C. Machines at Hatchery Building with 100% back up facility & for Exhaust fans at new Grower House etc.).

2

-

-

... More
S&F of suitable size of timer box, consisting with 1 no. 415 V. 32 A. FP MCB, 1 no. 32 A. 4 pole Power contactor, 1 no. 230 V., 6 A. SP MCB, 1 no. 10 A. toggle switch, 1 no. Digital timer clock, 1 no. 20 A. push on/ off type starter for manual operation, 4 nos. Inditating lamps, 1 no. 4 pole connector etc. incl. suitable size of interconnecting wires (power line drawn by 10 sq.mm. copper wire & control & indicating circuit drawn by 1.5 sq.mm. copper wire with copper sockets) as reqd. as per direction of E.I.C.. (for Compound lighting)

1

-

-

... More
S&D of the following sizes 1.1 KV voltage grade XLPE/PVC insulated Al. Armoured Cable. (Make: Havells/ Polycab/ Finolex/Gloster):

-

-

-

... More
2 core x 6 sq.mm. (for input power of Panel Room and DG Shed area)

45

-

-

... More
4 core x 16 sq.mm. (for compound lighting & for Input power of new Grower House).

750

-

-

... More
4 core x 35 sq.mm. (for Input power of office building & Hatchery building)

95

-

-

... More
4 core x 70 sq.mm. (for Interconnection at Panel Portion)

18

-

-

... More
Laying of following cables on wall/surface incl. S & F MS saddles & earthing attachments, making holes etc. as necy. mending good damages and painting.

-

-

-

... More
2 core x 6 sq.mm. with 1 no. 10 SWG GI (Hot Dip) Wire

8

-

-

... More
4 core x 16 sq.mm. with 2 nos. 10 SWG GI (Hot Dip) Wire

140

-

-

... More
4 core x 35 sq.mm. with 2 nos. 10 SWG GI (Hot Dip) Wire

15

-

-

... More
4 core x 70 sq.mm. with 2 nos. 10 SWG GI (Hot Dip) Wire

18

-

-

... More
Laying of following cable in UG trench 460 mm wide x 760 mm average depth, with proper brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed

-

-

-

... More
2 core x 6 sq.mm.

27

-

-

... More
4 core x 16 sq.mm.

570

-

-

... More
4 core x 35 sq.mm.

60

-

-

... More
Laying only following Cable through existing GI Pipe.

-

-

-

... More
2 core x 6 sq.mm.

10

-

-

... More
4 core x 16 sq.mm.

40

-

-

... More
4 core x 35 sq.mm.

20

-

-

... More
S&F of compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC insulated Al. armoured cables as below.

-

-

-

... More
2 core x 6 sq.mm.

2

-

-

... More
4 core x 16 sq.mm.

40

-

-

... More
4 core x 35 sq.mm.

8

-

-

... More
4 core x 70 sq.mm.

10

-

-

... More
Finishing the end of following XLPE/PVC insulated Al. armoured cables by crimping method incl. S&F of solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials:

-

-

-

... More
2 core x 6 sq.mm.

2

-

-

... More
4 core x 16 sq.mm.

40

-

-

... More
4 core x 35 sq.mm.

8

-

-

... More
4 core x 70 sq.mm.

10

-

-

... More
S&D of 80 mm dia x 1.5 mts. long GI Pipe pole (ISI-Medium) with 1 no. 3 mm thick G.I sole plate incl. necy. holes on sole plate as required, welded with pipe pole and Erection the pole by providing cement concrete (6:3:1) muffing around the pole of dimension 600x600x600 mm on the roof of the building after chipping the roof and fix the pole on the position by using fust nuts incl. 3mm thick net cement finish and providing G.I. earth bolt after making hole by drilling etc. on pole incl. painting the pole by 2 coat Aluminium paint over 1 coat RO Primer after cleaning the surface by emery paper as per direction of E.I.C..

11

-

-

... More
S&F of single arm header fabricated with 100 mm dia, 3 mm thick & 10" height G.I. pipe (pole cap) welded with 1.5 mtr. long 40 mm dia. 3 mm thick G.I. pipe at an angle of 20 to 25 deg with horizontal axis by using nuts, bolts washers etc. incl. painting by 2 coat Aluminium paint over 1 coat RO Primer after cleaning the surface by emery paper as per direction of E.I.C..

11

-

-

... More
S&F of Double arm header fabricated with 100 mm dia, 3 mm thick & 10" height G.I. pipe (pole cap) welded with 2 nos. 1.5 mtr. long 40 mm dia. 3 mm thick G.I. pipe at an angle of 20 to 25 deg with horizontal axis and 180 deg. angle between two arms by using nuts, bolts washers etc. incl. painting by 2 coat Aluminium paint over 1 coat RO Primer after cleaning the surface by emery paper as per direction of E.I.C..

5

-

-

... More
S&D of 8.5 mtr. Long Swagged type ST Pole of following specifications: (Shubham/ Kolkata Poles/ Utkarsh/ Bajaj). Designation - 410-SP-23 Overall Length - 8.5 mtr. Weight - 148 kg.

5

-

-

... More
Erection of Single Steel tubular pole/ "U" Channel of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly.

-

-

-

... More
Upto 9.0 mtr. - Size 0.6x0.6x1.70 mtrs.

5

-

-

... More
Above 9.0 mtr. - Size 0.6x0.6x1.91 mts

2

-

-

... More
Extra on items 1& 2 above, for providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) suitable for alkathene/ polythene pipe entry as directed for street light wiring, incl. S & F 25cmx25cmx10cm GI Loop box, 16SWG & incl. drilled hole in pole

7

-

-

... More
S&F of GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V. 16 A. kit-kat fuse unit, one NL on porcelain insulator and earthing terminal with lug, on wall by fust nuts, washers etc. as required including painting with anticorrosive paint.

3

-

-

... More
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V. 15 A. kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint

12

-

-

... More
S&Laying of 13 mm dia 3 mm thick heavy gauge Polythene Pipe through ST poles and Mini Poles with S& Laying GI fish wire for drawing looping wires. (from Loop Box to Outdoor light fitting).

78

-

-

... More
S&Laying of 13 mm dia 3 mm thick heavy gauge Polythene Pipe on wall by using Al. Shaddle and mending good damages to building works. (from Loop Box to "L" Arm Bracket).

20

-

-

... More
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint Upto 9.0 mtr. long pole

-

-

-

... More
1st coat of aluminium paint over 1 coat of RO priming

5

-

-

... More
2nd coat of aluminium paint over 1st coat

5

-

-

... More
S&D of 230 V. 40-45 W. LED outdoor type street light fittings, made up of pressure die cast housing with toughened glass and high power LED's with secondary optics, of following specifications. i. IP66 protection ii. 10 KV SPD included iii. Efficacy ≥110/120 LPW. (Make-Philips/Havells/Crompton)

3

-

-

... More
S&D of 230 V., 90 W. LED outdoor street type light fittings, made with pressure die cast housing with toughened glass and high power LED's with secondary optics, of following specifications (Philips - BRP409 LED110 CW M2 FG PSU GR V3/ CG - TRP-411-90-57-SL-GL-NSG/ Bajaj) with 5 years warrenty. i. IP66 protection ii. 10 KV SPD included iii. Efficacy ≥110/120 LPW. (Make-Philips/Havells/Crompton)

17

-

-

... More
S&D of 230 V., following wattage LED outdoor type Flood light fitting, made up of pressure die cast aluminium housing with toughened glass and high power LED's with secondary lenses, of following specifications with 5 years warrenty. i. IP66 protection ii. 10 KV SPD included iii. Efficacy ≥110/120 LPW. iv. CCT - 5500-6000 K.

-

-

-

... More
50-55 Watt. LED Flood light fitting. (Make-Philips/CG/Havells)

2

-

-

... More
350 Watt. LED Flood light fitting. (Make-Philips/CG/Havells)

3

-

-

... More
Fixing only outdoor type LED light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 3 x 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting.

2

-

-

... More
Fixing only the LED outdoor Light fittings on pole by Co's own tools & tackles incl. necessary connection as required with earthing as per direction of E.I.C..

18

-

-

... More
Fixing only Floodlight Fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure.

3

-

-

... More
S&F of following size medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required.

-

-

-

... More
32 mm dia

50

-

-

... More
40 mm dia

20

-

-

... More
SITC of 15’ x 4' x 7” (inch) depth waterproof LED Glow Sign Board whose structure will be made by 40 x 40 mm and 3 mm thick MS hollow square pipe with opening arrangement and Locking arrangement incl. necessary painting by 2 coat Synthetic enamel paint over 1 coat of RO primer after properly rubbing the surface by emery paper as per direction of E.I.C.. Front side of Glow Sign Board will be covered by 3 mm thick good quality ACP board and 6 mm thick Acrylic letters shall be fixed on it after Laser cutting the ACP board, Letters shall be rised by 3 mm and rest 3 mm shall be embedded in ACP board as per direction of E.I.C.. Others sides of Glow Sign Board shall be covered by 3 mm thick good quality ACP board except back portion which will be covered by 10 SWG Al. sheet. Every edges shall be perfectly covered by 1"x1" Al "L" type channel, so that the Glow Sign Board is waterproof. For fixing purpose, 3 nos. 40x40x3 mm painted MS bars per side (Total 6 nos.), welded with main structure must be given. For illuminate the Glow Sign Board, 16 nos. 230 V., 18 W. PC body LED tube (Philips - Mas LEDTube 1200mm 18W865 T8 I – 2100lm/ CG - LTB-20-865-(2)) shall be given inside the Glow Sign Board incl. necessary connection as per direction of E.I.C.. The cost of transportation, loading, unloading and scaffolding charges are included with the rate. The matter of Glow Sign Board will be written as per the requirement of concern authority which will be duly signed by authority as per direction of E.I.C..

60

-

-

... More
SITC of 20’ x 4' x 7” (inch) depth waterproof LED Glow Sign Board whose structure will be made by 40 x 40 mm and 3 mm thick MS hollow square pipe with opening arrangement and Locking arrangement incl. necessary painting by 2 coat Synthetic enamel paint over 1 coat of RO primer after properly rubbing the surface by emery paper as per direction of E.I.C.. Front side of Glow Sign Board will be covered by 3 mm thick good quality ACP board and 6 mm thick Acrylic letters shall be fixed on it after Laser cutting the ACP board, Letters shall be rised by 3 mm and rest 3 mm shall be embedded in ACP board as per direction of E.I.C.. Others sides of Glow Sign Board shall be covered by 3 mm thick good quality ACP board except back portion which will be covered by 10 SWG Al. sheet. Every edges shall be perfectly covered by 1"x1" Al "L" type channel, so that the Glow Sign Board is waterproof. For fixing purpose, 3 nos. 40x40x3 mm painted MS bars per side (Total 6 nos.), welded with main structure must be given. For illuminate the Glow Sign Board, 16 nos. 230 V., 18 W. PC body LED tube (Philips - Mas LEDTube 1200mm 18W865 T8 I – 2100lm/ CG - LTB-20-865-(2)) shall be given inside the Glow Sign Board incl. necessary connection as per direction of E.I.C.. The cost of transportation, loading, unloading and scaffolding charges are included with the rate. The matter of Glow Sign Board will be written as per the requirement of concern authority which will be duly signed by authority as per direction of E.I.C..

80

-

-

... More
Making necessary arrangement for fixing the above 80 Sq.Ft LED board by making necessary supporting structure to resist storm by S&F of 2 nos 10 mtr. Long, Iron body "U" channel having dimension of 80 mm x 150 mm x 80 mm & thickness 6 mm and 50mmx50mmx5mm M.S. angle incl.making 2nos having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented, incl. all fixing accessories including providing necessary fixing materials as per drawing

1

-

-

... More
Making necessary arrangement for fixing the above 60 Sq.Ft LED board by making necessary supporting structure to resist storm by S&F of 50mmx50mmx5mm M.S. angle incl.making 6nos CC (6:3:1) base block (around the MS angle dimension 0.45x0.45x0.60 mt.above roof top, neatly cemented finish (3 mm thick), incl. all fixing accessories including providing necessary fixing materials as per drawing

1

-

-

... More
Carrying for carrying of LED board, fabricating materials, welding machines & other accessories included loading & unloading at both the ends.

1

-

-

... More
Note: 1) All the above rates should be quoted inclusive of all taxes, duties and all ancilery charges with cost of maintenance, servicing, supply & replacement of spares for 1 (One) year from the date of commissioning. 2) Total is rounded off to the nearest rupees.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.