Public Works Department Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Public Works Department - PWD Tender
Electrical and Electronics
Eprocure
Opening Date12 Dec 2023
Closing DateCancelled
Tender AmountRefer Documents
Costs
EMD
₹ 19,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Wbpwd/ee-i/ckhed/nit-53/ 2023-24
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_WBPWD_621116_1Tender No
WBPWD/EE-I/CKHED/NIT-53/ 2023-24Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://wbpwd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Laying of cable above 3½ core 90 sqmm and upto 3½ core 150 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting [F1:2e]
170
-
-
... More
Laying of cable above 95 sq, mm. after cutting floor/pavement/ wall/ and making holes incl., embedding the cable at an average depth of 100mm as below and mending good the damages to original finish incl. removing the rubbish. [F3:5iii]
20
-
-
... More
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender,bolts & nuts, steel fastener etc. as required
of the following size. Incl. Al painting of MS support.
(ii) With 25x25x3mm angle iron support
300x50x1.25mm (18SWG). [D14:34a(ii)]
100
-
-
... More
Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire. From 70sqmm to 150sqmm. [F3:6(ii)]
100
-
-
... More
Supplying and fixing 160A, 415V, TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.[L&T] [D3:4a]
1
-
-
... More
Supply Suitable size fabricated MS box having 4-bar copper bus of length 8" each suitable for 300A current capacity inc. S&F three nos. 6A Siemense MCB for metering ckt, R-Y-B LED indicator and the box should fix on wall & above the cable entry of VTPN.
1
-
-
... More
Supply and fixing double door Vertical-TPN-MCB DB housing for MCCB incomer and TP-MCBs as outgoing with IP-43 protection, concealed in wall after cutting the wall & mending good the damages to original finish & necy. wall matching paint as required or total establishment on angle iron frame on wall incl. inter connection with suitable size of copper wire and neutral link & provision for earthing attachment require. [D11:15] LEGRAND EKINOX : Upto 250A,Enclosure (607724)-12-way
4
-
-
... More
Supplying and fixing double door Horizontal-TPN-MCB DB housing Enclosure only suitable for FP-MCB as incomer and DP-MCBs /SP-MCBs ('C'-curve,10kA,16-32A), as 2 nutral-bar,2 earth-bar and cable ties for cable/wire management as with IP-43 protection, concealed in wall after cutting the wall & mending good the damages to the original finish & necy. wall matching putty & paint as required or total establishment on angle iron frame (25mmX6mm)on wall incl. inter connection with suitable size of copper wire as required inside the box. [D10:14]
LEGRAND EKINOX : 6Way Enclosure (607716).
1
-
-
... More
Supply and fixing 415V/240V, of following rating "C"-curve MCBs (10kA)/MCCBs(35kA)(Legrand Make) on din rail in existing VTPNDB/TPN-DBs/SPN-DBs and necy. connection as required.
-
-
-
... More
i). 160A(35kA)FP MCCBs. [D8:10]
4
-
-
... More
ii). 63A (10kA) TP MCBs.
48
-
-
... More
iii). 6-32A (10kA) SP MCBs. [D6:07]
6
-
-
... More
iii). 6-32A (10kA) DP MCBs. [D6:07]
6
-
-
... More
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (RR/Havells/Finolex) in 20mm/25/35mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required(E-14/1,)
-
-
-
... More
i). 4 x 84/0.3 (6 sqmm) + 2 x 56/0.3 (4 sqmm) ECC.
170
-
-
... More
iii). 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC
100
-
-
... More
iv)2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC.#
60
-
-
... More
Finishing of the PVC insulated wire ends by socketing with pin/ ring type copper sockets and insulated tapes etc.,including supplying sockets, tapes.
-
-
-
... More
i)6sq mm. [F5:9(iii)]
476
-
-
... More
ii)4sq mm. [F5:9(ii)]
300
-
-
... More
iii)2.5sq mm. [F5:9(i)]
80
-
-
... More
Supply & Fixing Moisture proof,water-proof (outdoor type IP-65) PVC (Sintex-3020)looping cable box size 300x250x150mm deep having 2/3 mm thick body enclosure , with 4way copper terminal and having lined with rubber gasketed top cover should be fixed on wall by screws,nuts,washers etc, necy. socketting, rubber gasketted entry and exit as mending the good damages as original with proper finishing at terminal is required.
i). comprising of one no.415 V,63Amp FP Isolator on din channel ('C'-curve,legrand make)
17
-
-
... More
Supply and fixing 4-way MCB SS enclosure (indoor type) with IK-08 protection, [Legrand 507793] powder coated & S&F of 40/63 A,4pole MCB in DIN channel, concealed in wall after cutting the wall or mount it on the wall surface & mending good the damages to the original finish or total establishment on flat iron frame in wall incl. inter-connection with suitable size of copper wire, necy. painting,& provision for earthing attachment etc. as required.
17
-
-
... More
Supply and fixing 2-way MCB SS enclosure (indoor type) with IK-08 protection, [Legrand 507791] powder coated & S&F of 40 A,2pole MCB in DIN channel, concealed in wall after cutting the wall or mount it on the wall surface & mending good the damages to the original finish or total establishment on flat iron frame in wall incl. inter-connection with suitable size of copper wire, necy. painting,& provision for earthing attachment etc. as required.
10
-
-
... More
Supply & Fixing 240 V, 20A, plug socket without switch and with 25A,top on sheetmetal switch board embedded in wall or mount it on the wall surface incl. S & F 150x100x65mm MS (16SWG) switch board andbakelite/perspex top cover of 3mm thick by Brass screws aftermaking housing for switch by cutting bakelite/perspex coverincl S&F 25A top with indicator (Anchor) and making necessary connections as required. [PWD/GS Page: E-5 Item No.: 15&NS]
10
-
-
... More
Supplying & fixing of 415V, Timer DB Fixed on Wall by Angle frame or as per direction of EIC .
The Box should comprising following accessories.........
A).Double-door SPN-MCB Distribution Board with IP-42/43 protection 2+12 way as to GS[ make Legrand/simens].
B). 1No. 250V ,50Hz,16 Amp Digital daily & weekly time switches(Make L&T-67DDT0/Eqv. legrand)
C)1No 415V,40A FP-Contractor(Make-L&T/Eqv. legrand). D)1No. 415V,40A FP-MCB(Make-L&T/Eqv. legrand). E)1 No.I Toggle Switch inside the box, if required based on site conditions or project-specific needs.
F)1Nos LED Indication Lamp for running condition. G)The complete arrangement must be wiring by suitable size of PVC insulated Cu wire with suitable socket/lugs as per requirement & direction by EIC.
17
-
-
... More
Supplying & fixing of 230V, Timer DB Fixed on Wall by flat iron/Angle frame or as per direction of EIC .
The Box should comprising following accessories.........
A).Double-door SPN-MCB Distribution Board with IP-42/43 protection 2+8 way as to GS[ make Legrand/simens].
B). 1No. 250V ,50Hz,16 Amp Digital daily & weekly time switches(Make L&T-67DDT0/Eqv. legrand)
C)1No 415V,25A DP-Contractor(Make-L&T/Eqv. legrand). D)1No. 415V,25A DP-MCB(Make-L&T/Eqv. legrand). E)1 No.I Toggle Switch inside the box, if required based on site conditions or project-specific needs.
F)1Nos LED Indication Lamp for running condition. G)The complete arrangement must be wiring by suitable size of PVC insulated Cu wire with suitable socket/lugs as per requirement & direction by EIC.
5
-
-
... More
Rate should be quoted incl. of all taxes and cess.
-
-
-
... More
Defect Liability period : 1 year
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements