Public Works Department Tender
... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Public Works Department - PWD Tender
Civil And Construction
Building Construction
Eprocure
Opening Date6 Feb 2025
Closing Date19 Feb 2025
Tender Amount₹ 1,39,070
Costs
EMD
₹ 2,781Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Wbpwd/skhsd-i/ae/enit-16 Of 2024-2025
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_WBPWD_811842_9Bid Award Id
ViewTender No
WBPWD/SKHSD-I/AE/eNIT-16 OF 2024-2025Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://wbtenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Cement concrete (1:1.5:3) with graded stone chips 5.6 mm size with
hexagonal square mesh wire netting, I.R.C. fabric mesh or X.P. M. fitted and fixed after tying the existing reinforcement on concrete without distributing the same and with proper scarping and cleaning the reinforcement and disturbed concrete with wire brush etc. after applying a coat of cement including the cost of wire netting I.R.C or X. P. M. & cost of all handling and scaffolding complete as per direction of Engineer-in -charge.
c) 37.5mm thick
6.1
696
4247.31
... More
Applying epoxy based reactive joining agent for joining the old concrete with fresh concrete to be applied within manufacturer's specified time as per manufacturers specification. (0.4 Kg / m² of concrete surface).
6.1
368
2246.39
... More
(a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification
12.84
104
1346.53
... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes.
Pakur variety
0.26
6180
1606.8
... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]
(i) With 1:6 cement mortar
(b) 20 mm thick plaster
12.84
209
2689.21
... More
(ii) With 1:4 cement mortar
(c) 10 mm thick plaster
6.1
160
978.14
... More
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic
adhesive & grout materials etc.
B) Wall
With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.
(b) Area of each tile above 0.09 Sq.m
(i) Coloured decorative
13.02
1319
17184.32
... More
Labour for Chipping of concrete surface before taking up
Plastering work.
29.49
25
737.84
... More
(a)Cleaning the walls and ceiling by scraping, sand papering and
smoothening down the surface including putting.
10.55
20
213.74
... More
Rendering the Surface of walls and ceiling with White Cement base
WATER PROOF wall putty of approved make & brand.(1.5 mm thick)
29.49
145
4287.85
... More
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor)
(a) One Coat
ii) Solvent based interior grade Acrylic Primer
67.84
4016
2724.71
... More
Applying Acrylic Emulsion Paint of approved make and brand on walls
and ceiling including sand papering in intermediate coats including putty
(to be done under specific instruction of Superintending Engineer) :
(Two coats)
ii) Luxury Quality
67.84
83
5659.89
... More
Supplying solid flush type doors of deluxe decorative (both side) quality,
conforming to I:S 2202 timber frame consisting of top and bottom rail and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 27.5mm wide battens places both ways in order to made the door of solid core and internal lipping with teak, mahogony or rose wood approved decorative veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing the shutters in position but excluding the cost of hinges and other fittings in
ground floor:
(a) 35mm thick shutters (single leaf)
5.7
4713
26867.35
... More
Partition of teak veneer [1 mm] as per design fitted and fixed complete (excluding the supporting frame work & necessary teak wood battens):
In ground floor
(i) 4mm thick commercial quality
11.4
570
6507.92
... More
French polishing to wood work including preparing surface (ordinary
gloss)
(a) On new wood work
14.82
556
8248.37
... More
(b) On old French polished surface including complete removal of the old
polish.
7.44
641
4770.45
... More
(b) Priming one coat on timber or plastered surface with synthetic oil
bound primer of approved quality including smoothening surfaces by sand papering etc.
8
45
362.32
... More
A) Painting with best quality synthetic enamel paint of approved make
and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :
(a) On timber or plastered surface :
With super gloss (hi-gloss) -
(iv) Two coats (with any shade except white)
8
96
772.32
... More
Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized
(with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding &
casement windows, partitions, formed of basic sections of any ISI
embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work).
(A) In 10-12 Micron thickness Annodizing film
I) Natural white
g) Fixed glazing.
i) Top, bottom and side member.
18.6
382
7115.62
... More
ii) Mullion.
3.8
404
1535.2
... More
iii) Glazing clip.
13.08
59
779.44
... More
Supplying bubble free float glass of approved make and brand
conforming to IS: 2835-1987.
iv) 5mm thick coloured / tinted / smoke glass.
3.24
697
2258.93
... More
Providing and fixing exterior quality Aluminium Composite Panel (ACP)
wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP)
(b) 4mm thick (0.50mm Al.+3.0mm LDPE +0.50mm Al. PVDF coating)
1.2
3430
4116
... More
Supplying, fitting and fixing of false ceiling framework with powder coated exposed G.I. grid suspension system (E-Grid U-1520 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c.
The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins/ soffit all complete as per the drawing & directions of Engineer-in-charge.
26.55
556
14776.93
... More
(c) Supplying, fitting & fixing High Pressure steam Cured Non Asbestos fibre cement designer ceiling board (Density 1300Kg per Cu.m. ) of size595mm X595mm conforming IS 14862 and type B, catagory III of ISO 8336, tested as per AS-1530 Part 3 and BS-476 Part 4,5,6,7 & 8, should be placed in the Grid module to form a false ceiling all complete as per drawing & direction of Engineer - in- Charge.
False ceiling with
(ii) 6mm thick Fibre Cement Designer ceiling board.
26.55
469
12466.82
... More
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal /
Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
10
197
1978.3