Public Works Department Tender
... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Public Works Department - PWD Tender
Civil And Construction
Building Construction
Eprocure
Opening Date30 Jan 2025
Closing Soon26 Feb 2025
Tender AmountRefer Documents
Costs
EMD
₹ 5,20,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_WBPWD_809042_1Tender No
WBPWD/CEC/NIT/04/Q/24-25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://wbpwd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Design, Supply, Installation,Testing & Commissioning of HVAC Electrical Control Panel with Microprocessor Controller - 1 No. There should be provision for Integrated Electrical distribution system for power circuit & control circuit with MCCBs for Compressors & water pumps, Starters with push button (start & stop ), Bus Bar arrangement (Cu.), control copper wiring and inter connections. Customer will provide Single Point Electrical Power Source to HVAC Panel. Bidder should design & supply the HVAC Panel accordingly. The Panel should have one incomer and three sets of separate outgoing circuits for three chillers and pump motors (having electrical interlocking between Chiller & Chiller pump). Cu. Tubing & placement of instrument like Pressure Gauge of Refregerant System, Supply of Heater for Compressor, Compressor oil, Oil Pressure Indicator, Trip arrangement for High Pressure & Low Pressure Cut Off, Anti-freezing Cut Off, Reversal of Phases & Phase failure Cut Off, Flow Switch Cut Off, Automatic Chilled Water Bypass System in case of partial load condition.
1
-
-
... More
CHILLED WATER PUMP
Supply, erection, testing & commissioning of Chilled water duty, end suction back pull out type centrifugal pumpset at (having Bronze/CI Impeller) with TEFC, IP-55, Class F insulated Sq. cage induction motor, complete with common base frame, spring vibration isolators, coupling and coupling guard for the following duty & including items as specified below : (Make - Kirloskar/ Grundfoss/ xylem/ Armstrong/ Flowmore/ KSB)
Rated Flow 240 USGPM or higher at required water column head as per site condition (2 W + 1 S)
3
-
-
... More
SITC of Following sizes valves incl. necessary fixing materials as required. 150 mm dia Sluice Valve (Make - Honeywell/ Advance/ Oswal/ Kirloskar/ audco/ zoloto/sant/C &R)(Outgoing Header & Return)
2
-
-
... More
125/150 mm dia Check Valve/NRV (Make - Honeywell/ Advance/ Oswal/ Kirloskar/ audco /zoloto/sant/C &R) (Installed at Outlet of each pump)
3
-
-
... More
125/150 mm dia Sluice Valve (Make - Honeywell/ Advance/ Oswal/ Kirloskar/ audco/ zoloto/sant/C &R)(Installed at inlet & outlet of each pump)
6
-
-
... More
150 mm dia butterfly Valve (Make - Honeywell/ Advance/ Oswal/ Kirloskar/ audco/ zoloto/sant/C &R)(Installed at inlet & outlet of each pump)
3
-
-
... More
100 mm dia butterfly Valve (Make - Honeywell/ Advance/ Oswal/ Kirloskar/ audco/ zoloto /sant/C &R)(Installed at inlet & outlet of each pump)
3
-
-
... More
SITC of 125/150mm dia Y Strainer (Make - Honeywell/ Advance/ Oswal/ Kirloskar/ audco/zoloto/sant/C &R) (Installed at Inlet of each pump to isolate the perticals from system)
3
-
-
... More
4" Dial SS Pressure Gauge complete with syphon and isolation gauge cock.(Make - HGURU/ Tameson/ Equivalent) ( Installed at Inlet & Outlet of each pump to monitor pressure)
6
-
-
... More
25 mm NB Ball Valve For drain (Make - Honeywell/ Advance/ Oswal/ Kirloskar/ audco/zoloto/sant/C &R) ( to drain out water during maintenance)
3
-
-
... More
SITC of Purgeing Valve/Auto air vent with 15 mm Ball valve (Installed at each Room branch header & main headers) (Make - Honeywell/ Advance/ Oswal/ Kirloskar/ audco/zoloto/sant/C &R)
20
-
-
... More
Supply, Erection, Testing & Commissioning of MS ERW Chilled Water (Supply & Return) Piping (Class C) complete with flange , Tee, bend & other necessary fittings including weilding joints & MS supports and TF quality thermocol density 16kg/cum insulation with chicken wire mesh sand cement plaster (Pipes upto 150 NB shall be Heavy Grade as per IS: 1239 Part I and from 200 NB & above Pipes shall be as per IS: 3589 of specified thickness.) (Make-Tata/ Jindal/ SAIL) 150mm NB (Insulation 50 mm thick)
140
-
-
... More
100mm NB (Insulation 50 mm thick)
360
-
-
... More
80 mm NB (Insulation 50 mm thick)
360
-
-
... More
65 mm NB (Insulation 50 mm thick)
360
-
-
... More
50mm NB (Insulation 50 mm thick)
70
-
-
... More
32mm NB (Insulation 50 mm thick)
265
-
-
... More
25 mm NB (Insulation 50 mm thick)
180
-
-
... More
Floor Mounted Outdoor type Air Handling Unit - SITC of site assembled type modular double skinned construction with continuous insulation with thermal break. The AHU enclosure's outer & inner Skin layer of 0.6 mm or higher & outer skin has to be polymer coated and insulation panel should be made of thermal break profile - PUF insulation with thickness of at least 40mm or better. The AHU should have heat recovary ventilator or exchanger for extrating @ 400 CFM stale air with the arrangement of VCD and injection of fresh air @ 360 CFM with VCD and mixing chamber for balance return air and fresh air with 02 (Two) stage filtration system (Prefilter having efficiency (EU - 4/MERV7) 90% down to10 micron & Fine Filter having efficiency 95% down to 5 micron (MERV-14) (Make - FMI/ Spectrum/ Thermi) including UV lamp of suitable rating for each of the air-suction & discharge of condition space as well as injection of fresh air and emmission of stale air as per direction of EIC). The AHU Coil to be with hydrofolic coating. The addon suitable gadgets shall be a set of butterfly, balancing & control valve with pressure gauge & temparature gauge each AHU.
-
-
-
... More
The AHU Fan assembly should be either motor directly coupled with Impeller or Belt driven as per OEM standard suitable for air velocity range 7.3 - 8.2 ft./Sec through the multi-layer (6-8 row)12 mm - 19 mm dia Copper tubes with Alluminium Fins (as per OEM standard). There should be AHU fans of Forward/ Backward Curve, with discharge not less than 3400 CFM, compatable for 415V, 50 Hz supply continuous duty Class IE 1 (Make for Fan Unit - Nicotra/ Kruger/ Caryaire) (Make for Motor - Crompton / Kirloskar/ NEC/ ABB/ Siemens).External Static pressure shall be within 10 - 20 mm Wg +obstruction to overcome hepa filter at laminer bench. There should be electrical interlocking/switching arrangement for running the system in possitive or negetive pressure mode as per requirement. (Make : Zeco / System Air/ Edgetech/Daikin/Jaypee/Carrier India) (AHRI/EUROVENT CERTIFIED) --For OT-2
1
-
-
... More
SITC of site assembled type modular Single skinned construction with continuous insulation with thermal break. Outer skin has to be polymer coated and insulation panel should be made of thermal break profile - PUF insulation with thickness of at least 40mm or better. The AHU should have heat recovary ventilator or exchanger for extrating @ 400 CFM stale air with the arrangement of VCD and injection of fresh air @ 360 CFM with VCD and mixing chamber for balance return air and fresh air with 02 (Two) stage filtration system (Prefilter having efficiency (EU - 4/MERV7) 90% down to10 micron & Fine Filter having efficiency 95% down to 5 micron (MERV-14) (Make - FMI/ Spectrum/ Thermi) including UV lamp of suitable rating for each of the air-suction & discharge of condition space as well as injection of fresh air and emmission of stale air as per direction of EIC). The AHU Coil to be with hydrofolic coating. The addon suitable gadgets shall be a set of butterfly, balancing & control valve with pressure gauge & Water Bypass system in case of partial load condition.
-
-
-
... More
The AHU Fan assembly should be either motor directly coupled with Impeller or Belt driven as per OEM standard suitable for air velocity range 7.3 - 8.2 ft./Sec through the multi-layer (6-8 row)12 mm - 19 mm dia Copper tubes with Alluminium Fins (as per OEM standard). There should be AHU fans of Forward/ Backward Curve, with discharge not less than 3400 CFM, compatable for 415V, 50 Hz supply continuous duty Class IE 1 (Make for Fan Unit - Nicotra/ Kruger/ Caryaire) (Make for Motor - Crompton / Kirloskar/ NEC/ ABB/ Siemens).External Static pressure shall be within 10 - 20 mm Wg +obstruction to overcome hepa filter at laminer bench. There should be electrical interlocking/switching arrangement for running the system in possitive or negetive pressure mode as per requirement. (Make : Zeco / System Air/ Edgetech/Daikin/Jaypee/Carrier India) (AHRI/EUROVENT CERTIFIED) --For OT-1
1
-
-
... More
SITC of site assembled type modular Single skinned construction with continuous insulation with thermal break. Outer skin has to be polymer coated and insulation panel should be made of thermal break profile - PUF insulation with thickness of at least 40mm or better. The AHU should have Heat Recovery ventilator or exchanger for extrating @ 940 CFM stale air with the arrangement of VCD and injection of fresh air @ 850 CFM with VCD and mixing chamber for return air and fresh air with 03 (Three) stage filtration system (Prefilter having efficiency (EU - 4/MERV7) 90% down to10 micron, Fine Filter having efficiency 99% down to 0.3 micron (MERV-14 (Make - FMI/ Spectrum/ Thermi) and HEFA filter MERV-17 0.3 micron for both Inlet & Outlet including UV lamp of suitable rating for each of the air-suction & discharge of condition space as well as injection of fresh air and emmission of stale air as per direction of EIC).The AHU Coil to be with hydrofolic coating. The addon suitable gadgets shall be a set of butterfly, Water Bypass System in case of partial load condition
-
-
-
... More
The AHU Fan assembly should be either motor directly coupled with Impeller or Belt driven as per OEM standard suitable for air velocity range 7.3 - 8.2 ft./Sec through the multi-layer (6-8 row)12 mm - 19 mm dia Copper tubes with Alluminium Fins (as per OEM standard). The AHU shall consist of 1 no. Centrifugal Blower with 2 nos. (I W + lS) TEFC Squirell cage induction motor with Supply Air Damper. There should be AHU fans of Forward/ Backward Curve, with discharge not less than 10000 CFM, compatable for 415V, 50 Hz supply continuous duty Class IE 1 (Make for Fan Unit - Nicotra/ Kruger/ Caryaire) (Make for Motor - Crompton / Kirloskar/ NEC/ ABB/ Siemens).External Static pressure will be within 10 - 20 mm Wg. There should be electrical interlocking/switching arrangement for running the system in possitive or negetive pressure mode as per requirement.(Make : Zeco / System Air/ Edgetech/Daikin/Jaypee/Carrier India) (AHRI/EUROVENT CERTIFIED) --For ICU & HDU
2
-
-
... More
SITC of site assembled type modular Single skinned construction with continuous insulation with thermal break. Outer skin has to be polymer coated and insulation panel should be made of thermal break profile - PUF insulation with thickness of at least 40mm or better. The AHU should have Heat Recovery ventilator or exchanger for extrating @ 960 CFM stale air with the arrangement of VCD and injection of fresh air @ 960 CFM with VCD and mixing chamber for return air and fresh air with 02 (Two) stage filtration system (Prefilter having efficiency (EU - 4/MERV7) 90% down to10 micron, Fine Filter having efficiency 95% down to 5 micron (MERV-14 (Make - FMI/ Spectrum/ Thermi) for both Inlet & Outlet including UV lamp of suitable rating for each of the air-suction & discharge of condition space as well as injection of fresh air and emmission of stale air as per direction of EIC).The AHU Coil to be with hydrofolic coating. The addon suitable gadgets shall be a set of butterfly, balancing & control valve with pressure Water Bypass System in case of partial load condition.
-
-
-
... More
The AHU Fan assembly should be either motor directly coupled with Impeller or Belt driven as per OEM standard suitable for air velocity range 7.3 - 8.2 ft./Sec through the multi-layer (6-8 row)12 mm - 19 mm dia Copper tubes with Alluminium Fins (as per OEM standard). The AHU shall consist of 1 no. Centrifugal Blower with 2 nos. (I W + lS) TEFC Squirell cage induction motor with Supply Air Damper. There should be AHU fans of Forward/ Backward Curve, with discharge not less than 10000 CFM, compatable for 415V, 50 Hz supply continuous duty Class IE 1 (Make for Fan Unit - Nicotra/ Kruger/ Caryaire) (Make for Motor - Crompton / Kirloskar/ NEC/ ABB/ Siemens).External Static pressure will be within 10 - 20 mm Wg. There should be electrical interlocking/switching arrangement for running the system in possitive or negetive pressure mode as per requirement.(Make : Zeco / System Air/ Edgetech/Daikin/Jaypee/Carrier India) (AHRI/EUROVENT CERTIFIED) --For 24 Bed Ward
1
-
-
... More
Ceiling Suspended Indoor type Air Handling Unit - SITC of site assembled type modular single skinned construction with continuous insulation with thermal break. The AHU enclosure's outer skin has to be polymer coated and insulation panel should be made of thermal break profile - PUF insulation with thickness of at least 40mm or better. Extrating stale air @ 100 CFM with the arrangement of VCD and injection of fresh air @ 90 CFM with VCD and mixing chamber for return air and fresh air with 03 (Three) stage filtration system (Prefilter having efficiency (EU - 4/MERV7) 90% down to10 micron, Fine Filter having efficiency 95% down to 5 micron (MERV-14) & Hepa filer 99% down to 0.3 micron (Make - FMI/ Spectrum/ Thermi). The addon suitable gadgets shall be a set of butterfly, balancing & control valve with pressure gauge & temparature gauge each AHU.
-
-
-
... More
The AHU Coil to be with hydrofolic coating. The AHU Fan assembly should be either motor directly coupled with Impeller or Belt driven as per OEM standard suitable for air velocity range 7.3 - 8.2 ft./Sec through the multi-layer 12 mm - 19 mm dia Copper tubes with Alluminium Fins (as per OEM standard). There should be AHU fans of Forward/ Backward Curve, with discharge not less than 2000 CFM, compatable for 415V, 50 Hz supply continuous duty Class IE 1 (Make for Fan Unit - Nicotra/ Kruger/ Caryaire) (Make for Motor - Crompton / Kirloskar/ NEC/ ABB/ Siemens). External Static pressure will be within 10 - 20 mm Wg. (Make : Zeco / System Air/ Edgetech/Daikin/Jaypee/Carrier India) (AHRI/EUROVENT CERTIFIED)
(--For Isolation Room 1 & 2)
2
-
-
... More
Ceiling Suspended Indoor type Air Handling Unit SITC of site assembled type modular double skinned construction with continuous insulation with thermal break. The AHU enclosure's outer & inner Skin layer of 0.6 mm or higher & outer skin has to be polymer coated and insulation panel should be made of thermal break profile - PUF insulation with thickness of at least 40mm or better. Extrating stale air @ 350 CFM with the arrangement of VCD and injection of fresh air @ 350 CFM with VCD and mixing chamber for return air and fresh air with 02 (Two) stage filtration system (Prefilter having efficiency (EU - 4/MERV7) 90% down to10 micron & Fine Filter having efficiency 95% down to 5 micron (MERV-14) (Make - FMI/ Spectrum/ Thermi). The addon suitable gadgets shall be a set of butterfly, balancing & control valve with pressure gauge & temparature gauge each AHU.
-
-
-
... More
The AHU Coil to be with hydrofolic coating. The AHU Fan assembly should be either motor directly coupled with Impeller or Belt driven as per OEM standard suitable for air velocity range 7.3 - 8.2 ft./Sec through the multi-layer 12 mm - 19 mm dia Copper tubes with Alluminium Fins (as per OEM standard). There should be AHU fans of Forward/ Backward Curve, with discharge not less than 3400 CFM, compatable for 415V, 50 Hz supply continuous duty Class IE 1 (Make for Fan Unit - Nicotra/ Kruger/ Caryaire) (Make for Motor - Crompton / Kirloskar/ NEC/ ABB/ Siemens). External Static pressure will be within 10 - 20 mm Wg. (Make : Zeco / System Air/ Edgetech/Daikin/Jaypee/Carrier India) (AHRI/EUROVENT CERTIFIED)
(--For Pre & Post OT)
1
-
-
... More
SITC of UVC Emitter for the above AHU'S for prevention of fungus in the child water coolong coils. The minimum UV intensity in in the coils should be greater than 1000 UW-SEC/CM2 for Ots. The unit shall be UL Listed(UL-1995)(Make-Alfa)
2
-
-
... More
SITC of Aluminium laminar bench with perforated sheet cover to accommodate inside HEPA filter bank along with necessary support as per standard of minimum 6 ft X 8ft dimension for OT Area as per approved drawing necessary flange joints of air duct shall have to be fixed with sealant adhesive to prevent leakage.
2
-
-
... More
Chilled water In-duct type Indoor FCU units with compact 3 Row Cu. cooling coil, multi-speed fan motor, the blower shall be dynamicaly balanced and designed for silent operation, the filters shall be washable synthetic media type arranged for convenient cleaning and replacement and inbuilt drain pump. The Unit should be equipped with Ball Valves / Stainer & Actuator as required. The unit is to be supplied with chorded remote controller. 2.5 TR (Make - Daikin/ Johnson Control/ EdgeTech/ Zeco/ VTS/ Citizen/Jaypee /Carrier India) (Allocation- LDR - 1&2-2 no each, Point Care Lab, USG, Doctor Room-GF, Proc. Room-1&2-1st Fl, Dialysis Room-2no, Doctors Room-1st Fl, Proc. Room-2nd Fl, Doc. Room-2nd Fl)
14
-
-
... More
2 TR (Make - Daikin/ Johnson Control/ EdgeTech/ Zeco/ VTS/ Citizen/Jaypee /Carrier India) (Allocation- Procedure Room- 2nd Fl)
2
-
-
... More
1.5 TR (Make - Daikin/ Johnson Control/ EdgeTech/ Zeco/ VTS/ Citizen/Jaypee /Carrier India) (Allocation- Minor Proc. Room, Radiology-2no.,)
4
-
-
... More
Supply, erection, testing & commissioning of 2000 litre capacity PVC double-layer expansion / cushion tank, insulated with cover of thermocol, sand, cement plaster as per chilled water piping (Make - Syntex/ Patton/ Supreme), provision of make up water inlet, overflow outlet, Air release vent, etc.
1
-
-
... More
Supply and Laying of Rigid PVC Drain Pipe (Medium Class)with respective fittings ,proper supports at 5 feet interval and duly insulated with 6 mm thick closed cell nitrile rubber insulation. (Make : Oriplast/ Supreme/ Filolex/ Ashirbad/ Astral)
20 mm NB
60
-
-
... More
32 mm NB
60
-
-
... More
40 mm NB
30
-
-
... More
Supply and fixing of Flexible double Canvas connection in between each FCU & Al. Supply Air grill mounted on Gypsum Boxing cover. (Custom Make or Asper direction of EIC)
28
-
-
... More
Supply & fixing of Al Powder coated extruded Alluminium return air grilles (Make : Premier/ Systemair/ Caryaire/ Air Enterprise) without volume control dampers.
40
-
-
... More
Supply & fixing of Al powder coated extruded Alluminium Supply air grilles (Make : Premier/ Systemair/ Caryaire/ Air Enterprise) with alluminium volume control damper.
25
-
-
... More
Major & minor civil works required to execute before and after the HVAC works for mending good damages to original finish painting.
1
-
-
... More
SITC of GI DU CT of Class - VIII grade for supply/ return air duct along with pre fabricated plenum for supply and return air with necessary supports, flanges etc. as required and as per IS 655 and IS -277 standards of following gauges. (Make- Sail/Jindal/Tata))
24 SWG thick
950
-
-
... More
22 SWG thick
200
-
-
... More
Supplying,fitting & fixing in position suspended boxing for (concentric) return and supply air arrangement for ducting incl false ceiling for boxing of IDU with frame work of aluminium hollow section of size 50mm X 25mm (2.0mm thickness) combined with aluminium corners of size 38mm X 25mm, suspended by aluminium hollow tube section of size 38mm X 25mm having size as suitable with aluminium composit panels (ACP) - Interior grade of thickness 3.0 mm comprising of proctective film, polyester coating, primer, aluminium coil, adhesive film, polyethylene core again with one layer adhesive film, aluminium bottom coating and finally service coating as per manufacturer's specification finished with aluminium screw and silicon sealent incl.suitable arrangement of grill fixing complete in all respect including all incidental charges etc. as per direction of EIC.
120
-
-
... More
Supply and fixing acoustic lining of supply air duct and plenum with 13 mm thick open cell Nitrile rubber (Class-O) of density 140Kg/cum-160Kg/cum insulation with cadmium plated nuts, bolts, stick pins, CPRX compound etc. completed as per direction of EIC (Make-Accroflex/ K-flex/Armacell).
166
-
-
... More
Supply and fixing Heat Retardant closed cell Class'O' 50 mm thick Nitrile Rubber insulation with AI Foil Faced Outside Supply Air duct. (Make-Armacell/K-flex /Accroflex)
1066
-
-
... More
Supply & Fixing of underdeck insulation with 50mm thick TF quality Expanded polysterene slab(Make-Thermowell/ Board sell)
250
-
-
... More
Supply & Fixing of Motorised Fire Damper, Galvanized Steel Sheet with 125 GSM Zink Coated, Certified by CBRI ( U-555, 1995) with minimum fire rating not less than 120 min, must be Fusiable Link Spring with 74°C Temerature rating Ul Listed with actuator as per requirement. (Make-Greenheck/Systemair/Air master/Caryaire)
8
-
-
... More
SITC of heavy duty anti vibrational pad to protect the system from any kind of unwanted vibration.
8
-
-
... More
S & Laying of 1.1 KV Grade PVC/ XLPE insulated, PVC sheathed cable, copper unmoured control cable incl. to laid on wall surface by suitable clamping, proper glanding & finishing the cable ends with solderless sockets for following cables(Make-Gloster/Polycab/Havells)
7 Core 1.5 Sq. Sq.mm XLPE round copper Cable
500
-
-
... More
4 Core 2.5 Sq. Sq.mm XLPE copper Cable
45
-
-
... More
4 Core 16 Sq.mm XLPE Al. Armoured Cable
100
-
-
... More
4 Core 10 Sq.mm XLPE Al. Armoured Cable
150
-
-
... More
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. (i) With 25x25x3mm angle iron support
200x50x1.25mm (18SWG)
300
-
-
... More
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
20
-
-
... More
SITC of wall mounted AHU Electric control panel, having rigid and self supporting structure fabricated with 14 SWG CRCA sheet with M.S. angle iron frame (main frame with 25 x 25 x 5 mm MS )angle.The panel is to be properly gasketed to prevent the dust & vermin. The panel consist of following accessories.
-
-
-
... More
i)32A FP MCB- 1No. (L&T/ABB/Siemens) As incomer
Bus Bar: 63 A Aluminium Bus bar -1 Set Out Going: i)25A FP MCB- 1No. (L&T/ABB/Siemens) ii) 6 A SP MCB -1No. (L&T/ABB/Siemens) iii) DOL Starter-1No. (L&T/ABB/Siemens) iv) 4Pole Power contactor-1 No. (L&T/ABB/Siemens) v) On delay timer-1no. (L&T/ABB/Siemens) vi) ON/OFF Push Button- 1 Set (L&T/ABB/Siemens) vii) LED indicationg Lamp ON/OFF-1Set
5
-
-
... More
SITC of wall mounted AHU Electric control panel, having rigid and self supporting structure fabricated with 14 SWG CRCA sheet with M.S. angle iron frame (main frame with 25 x 25 x 5 mm MS )angle.The panel is to be properly gasketed to prevent the dust & vermin. The panel consist of following accessories.
-
-
-
... More
i)63A FP MCB- 1No. (L&T/ABB/Siemens) As incomer
Bus Bar: 100 A Aluminium Bus bar -1 Set Out Going: i)63A FP MCB- 1No. (L&T/ABB/Siemens) ii) 6 A SP MCB -1No. (L&T/ABB/Siemens) iii) DOL Starter-1No. (L&T/ABB/Siemens) iv) 4Pole Power contactor-1 No. (L&T/ABB/Siemens) v) On delay timer-1no. (L&T/ABB/Siemens) vi) ON/OFF Push Button- 1 Set (L&T/ABB/Siemens) vii) LED indicationg Lamp ON/OFF-1Set
3
-
-
... More
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with
bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:
(a) By ISI-Medium GI pipe
2
-
-
... More
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.
Solid GI wire No. 4 SWG
30
-
-
... More
N.B. : 1) Any other minor item or items left out due to inadvertance should be deemed to be included in the scope of work. Bidders are advised to physically visit the site in accordance with the building drawing to be provided by the Tender Inviting Authority and quote the price accordingly.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%