Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Public Health Engineering Department - PHED Tender
Civil And Construction
Eprocure
Opening Date4 Oct 2024
Closing Date22 Nov 2024
Tender Amount₹ 7,05,542
Costs
EMD
₹ 14,111Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Wbphed/ee/maad/niet _03 Of 2024-2025 Sl No.09
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PHED_761890_9Tender No
WBPHED/EE/MAAD/NIeT _03 of 2024-2025Tender Authority
Public Health Engineering Department ViewPurchaser Address
-Website
http://https://www.wbphed.gov.in/en/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
(a) 20 mm. thick plaster (1:4)
-
-
-
(i) Beyond 16 M upto 20 M from GL
27
5237
193.97
(ii) 20 M & Above
180
35814
198.97
(b). (a) 10 mm. thick plaster (1:3)
-
-
-
(i) Beyond 16 M upto 20 M from GL
21
3079
146.65
(ii) 20 M & Above
75
11373
151.65
Cleaning the exposed reinforcement preferably upto full diameter by wire brush, applying two coats of polymer based rust removing compound left for 24 hours, removing the coating and then applying two (2) coats of polymer modified anti corrosive protective coating formulated to inhibit the corrosion of reinforcement as per manufacturer's specification] [Mode of measurement:The affected surface area of reinforcement shall be considered for payment]
2.5
1962
785
Cleaning the concrete surface by removing dirt and debris, marking defective locations and removing loose concrete by careful stripping untill hard surface is exposed, cutting the concrete to regular shape, wire brushing the exposed surface and removing debris from site complete as per direction of the Engineer - in - Charge.
90.9
8181
90
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per 1:456 and relevant special publications submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in-charge Consumption of cement will be less than 300 Kg. of controlled concrete but actual consumption will be determined on the basis of preminary test and job mix foumula. In ground floor and foundation.
[using concrete mixture]
M 25 Grade (Rate Analysis)
-
-
-
i) Pakur Variety
-
-
-
Add extra over the rate of ground floor for basement and each additional floor above ground floor for items 4 to 10
i. Upto 4th floor - 58.88
ii. Above 4th floor - 71.44
note : Floor height as top of the bracing
-
-
-
i. Upto 4 M from GL
0.25
1422
5690.7
ii. Beyond 4 M upto 8 M from GL
0.25
1446
5785.7
iii. Beyond 8 M upto 12 M from GL
0.25
1470
5880.7
iv. Beyond 12 M upto 16 M from GL
0.25
1493
5975.7
v. Beyond 16 M upto 20 M from GL
0.25
1517
6070.7
vi. 20 M & Above upto top of OHR (Landing, Step, Roof Dome, walk way, Platform etc.)
1
6186
6186.7
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per 1:456 and relevant special publications submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in-charge Consumption of cement will be less than 300 Kg. of controlled concrete but actual consumption will be determined on the basis of preminary test and job mix foumula. In ground floor and foundation.
[using concrete mixture]
M 30 Grade (Rate Analysis).
0.75
4772
6363.83
Applying epoxy based reactive joining agent for joining the old concrete with fresh concrete to be applied within manufacturer's specified time as per manufacturers specification. (0.4 Kg / m² of concrete surface).
34.25
10583
309
Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturer's specified rate) for concrete of various grades
2.7
321
119
Removing loose scales, blisters etc. from old painted surface and thoroughly smoothening the surface to make the same suitable for receiving fresh coat of paint.
1072
22512
21
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC.
-
-
-
Ground floor, Two coats upto 4mtr. from G.L.
-
-
-
Add extra for each adding floor over the rate for ground
-
-
-
i. Upto 4 M from GL
140
4396
31.4
ii. Beyond 4 M upto 8 M from GL
140
4495
32.11
iii. Beyond 8 M upto 12 M from GL
140
4594
32.82
iv. Beyond 12 M upto 16 M from GL
140
4694
33.53
v. Beyond 16 M upto 20 M from GL
215
7361
34.24
vi. 20 M & Above upto top of OHR (Landing, Step, Roof Dome, walk way, Platform etc.)
600
21036
35.06
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.
-
-
-
In Ground floor (Two Coat) a) Normal Acrylic Emulsion
-
-
-
Add extra for each adding floor over the rate for ground
-
-
-
i. Upto 4 M from GL
140
13580
97
ii. Beyond 4 M upto 8 M from GL
140
13679
97.71
iii. Beyond 8 M upto 12 M from GL
140
13778
98.42
iv. Beyond 12 M upto 16 M from GL
140
13878
99.13
v. Beyond 16 M upto 20 M from GL
215
21465
99.84
vi. 20 M & Above upto top of OHR (Landing, Step, Roof Dome, walk way, Platform etc.)
600
60396
100.66
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
4.98
144
29
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :
-
-
-
(b) On steel or other metal surface : With super gloss (hi-gloss) -
-
-
-
(iv) Two coats (with any shade except white)
4.98
393
79
Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy.
20
2040
102
Sealing of cracks / porous concrete by injection process through nipples/Grouting complete as per Technical specification.
-
-
-
Cement mortar (1:1) Grouting
100
13900
139
Supplying mosquito proof net made of polythene (NETLON) size 75cm. X 75cm. for ventilator including fitting, fixing in the best sal wood frame of 8cm. X 5cm. cross section with necessary wooden batten fixing the assembly with necessary MS clamp in RCC wall at the lantern.
2.99
5026
1681
Supplying at site hoisting, fitting, fixing erecting and building in position where necessary 450mm.wide ladder as per design consisting of 2nos. M.S.Plate of 8mm.thick with necessary base plate 60mm wide; and 16mm.dia M.S.round or square bar as steeps placed @ 300 c/c including fabrication, welding drilling etc. as per drawing and direction and finished with two coats of synthetic enamel painting over a coat of red lead primer etc. all complete as per ;direction of the EIC
15
16005
1067
Construction of masonry drain 300 mm X 250 mm inner section with 1st class 250 mm th. Brick work in cement mortar(1:4) over a layer of single brick flat soling , sand filling 100mm th. and 100 mm th. weak cement concrete(6:3:1) with graded stone ballast pakur variety (40mm size) including earth work in excavation , 15mm th. Cement plaster(4:1) and neat cement punning all rounding the drain etc. all complete as per approved design , drawing and direction of the Engineer in-charge.
80
137440
1718
Add GST @ 18%
591997.04
106559
0.18
Add Labour Welfare Cess @ 1%
698556.51
6985
0.01