Public Health Engineering Department Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Public Health Engineering Department - PHED Tender
Civil And Construction
Pipe Line Project
Eprocure
Opening Date6 Dec 2024
Closing Soon18 Dec 2024
Tender Amount₹ 5,74,484
Costs
EMD
₹ 11,490Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Operation - Maintenance Pipeline And Allied Works Of Bahira W-s Scheme Etc.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PHED_780194_3Tender No
WBPHED/EE/BArD/NIeT-19/2024-25Tender Authority
Public Health Engineering Department ViewPurchaser Address
-Website
http://https://www.wbphed.gov.in/en/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Labour charges for repairing of UPVC Pipe by using UPVC socket and solvent cement including earth work in excavation with clewatering and necessary tracing out the actual position of brusting / leakage, cutting the pipe to required length in the trenches and replacing the same with new pipe (as per required length) including fitting, fixing after roughing the UPVC surface & supplying and applying solvent cement, back filling the trenches with excavated earth upto the same as per direction of EIC all complete (UPVC pipes and specials, solvent cement to be supplied by the Agency). Unserviceable broken withdrawan surplus materials are to be deposited to the Deptt. Store.
-
-
-
a) 75 mm dia
10
603
6030
b) 90 mm dia
50
653
32650
c) 110 mm dia
15
736
11040
d) 125 mm dia
6
819
4914
e) 140 mm dia
8
1202
9616
f) 160 mm dia
5
1345
6725
g) 180 mm dia
3
1493
4479
h) 200 mm dia
7
1714
11998
Extra repairing charges for changing of gland packing of sluice valve/ air valve with supplying of gland packing grease etc bailing out of water including removing the top cover slab of valve chamber and refixing the same after completion of work as per direction of E.I.C.
a) 80 mm dia to 125 mm dia
12
230
2760
b) 150 mm dia. To 250 mm dia
8
322
2576
c) 300 mm dia. To 350 mm dia
5
488
2440
Repairing of air valves by changing the ball with changing the requisite nuts and bolts and rubber insertion all complete as per direction of EIC.
2
260
520
Making barricading for protecting the trench to avoid any accident including making arrangement of road light during the night.
10
962
9620
Repairing of flange joint after dismantling the joints, removing the unserviceable rubber insertion and supply new rubber insertion and supply upto 50 % of new nuts and bolts all complete including necessary earth work dewatering & supply of washer etc. all complete as per direction of EIC
-
-
-
a) 80 mm dia. to 100 mm dia. 311.00 Each
6
311
1866
b) 125 mm dia. to 200 mm dia. 545.00 Each
4
545
2180
c) 250 mm dia to 350 mm dia. 744.00 Each
2
744
1488
Opening the cap / plug of washout point and opening sluice valve to clean the pipe, cleaning the cap / plug and sluice valve after completion of the work including earth work in excavation and refilling the same, draining out washed water etc. as per direction of ElC and replacing RCC Top slab cover where necessary including refixing the opened cap/plug in position complete.
a) Cap Opening.
5
410
2050
Dewatering from the excavated trenches for repairing any type of pipe line including Hire Charge of pump / carriage / Fuel & lubricant / Operator etc. for big dia pipes more, than 200
mrn dia all complete as per direction of EIC.
(This item will be executed after the permission of E.l.C.)
5
931
4655
Cleaning the chokage of AC/DI/CI / UPVC Pipes in the existing line by split bamboo passing through the new pit on the line and cleaning silt, bats or any obstructed materials in the line and cleaning by washed water. (Work to be executed as per prior approval and direction of EIC).
30
84
2520
Withdrawing and relaying of DI/CI pipes / AC pipe after excavation of earth and with the help of chain pully derrick etc. by dismantling & jointing by rubber gasket joint or lead joint or flange joint and stacking the withdrawn pipes and specials at site store /road flank, godown etc. all complete in the excavated same trench & as per direction of EIC.
-
-
-
a) 80 mm dia to 125 mm dia
15
144
2160
b) 150 mm dia to 200 mm dia
10
147
1470
Cleaning silt (every month) from the over head reservoir, cleaning washing and disinfecting the same with bleaching powder, including machinery, tools and plants as per direction of EIC complete (Bleaching powder will be supplied by the agency).
-
-
-
a) Upto 1.50 lakh gallon capacity OHR.
2
2408
4816
Supplying Bleaching Powder of approved brand (DCM/Modi/Kanoria) including all charges and free delivery at site.
30
50
1500
Supplying of UPVC Coupler 6Kg., class – III conforming to IS : 4985 – 2000 with latest revision and amendments ( This item is applicable for maintenance/ repairing work of pipe line only).
-
-
-
a) 63 mm dia ( OD )
1
35
35
b) 75 mm dia ( OD )
1
48
48
c) 90 mm dia ( OD )
1
67
67
d) 110 mm dia ( OD )
1
99
99
e) 140 mm dia ( OD )
1
185
185
f) 160 mm dia ( OD )
1
347
347
Supplying, laying, fiting, fixing and jointing of UPVC pipes conforming to IS:4985-2000 with latest revision and amendments, if any, with necessary UPVC/CI specials, CIDF sluice valves, as per relevant I.S. specification including labour charges for earth work in excavation in any kind of soil including mixed soil with boulder ,road sub-grade and its flanks but excluding moorum and laterite or sand stonehard arock including cutting of brick payment without damaging the existing telephone/electrical cable line etc.(in case of damage of any type of cable line during excavation, necessary damaged charges as applicable by the respaective authority will be borne by the agency in his own cost. Loading, unloading, carrying of pipes, specials, valves from the local store to work site and lowering laying of pipes specials valves carefully in trenches maintaining proper levels and alignment ,jointing the pipe and specials including supplying of good quality/approved brand solvent cement (as per IS:14182-1994 including cost of all fabricated PVC fitting i.e. tees,bend, reducers, adopter etc.as per IS:101-1988 and making flange joints including supplying required quantity of nuts, bolts and rubber insertion (CIDF sluice valves will be supplied by the department free of cost) as required at site by adopting suitable method so as to facilate the maintenance of pipe line locally as per conventional method including back filling the trenches with good earth obtained from excavation of trenches including consolidation with watering in layer not exceeding 150mm thk. with maintaining an average depth of cushion of 1.10mtr. from the top of pipe line including making interconnection with distribution pipes etc. all complete as per drawing direction and satisfaction of the E.I.C.
N.B. i) Manufacturer’s test certificate for UPVC pipe & specials to be produced before laying of pipe line.
(A) Pressure Rating : Class - III
(i) Laying of pipe line including cost of pipe only excluding cost of specials/fittings & valves.
-
-
-
b) 75 mm dia
6
258
1548
c) 90 mm dia
12
342
4104
d) 110 mm dia
5
471
2355
e) 125 mm Dia
4
643
2572
f) 140 mm dia
4
785
3140
g) 160 mm dia
3
974
2922
h) 200 mm dia
3
1544
4632
Filling the pipe line with water, testing hydraulically as per I.S 3114-1965 (Article-6) in section of a length not exceeding 500mtr. for head of pressure as per specification including supplying installing and fixing all equipments such as diesel pump set, blank flange, pressure gauge, valve, pressure pump and all other tools and plants including drilling topping and plugging of necessary holes to pipes, blocking ends providing temporary thrust block and subsequent blocking of holes and other jointing materials and dismantling and removal of the same including disposal of water etc. all complete as per specification and direction of EIC. The rate is inclusive of cost of requisite water to be arranged by the contractor (Recovery rate of water @ Rs.10.00/m3, if contractor used water from deptt. source).
-
-
-
b) 75 mm dia
6
3
18.9
c) 90 mm dia
12
3
43.2
d) 110 mm dia
5
3
18.9
e) 125 mm Dia
4
3
15.28
f) 140 mm dia
4
4
16.96
g) 160 mm dia
3
4
14.34
h) 200 mm dia
3
5
16.92
Cleaning thoroughly the inner surface of pipe line including specials and valves by flushing with water and subsequently disinfection of the same pipe line by flushing again with water containing bleaching powder resulting in residual chlorine not less than 15mg/ltrs. after 24hrs. of such filling including laboratory testing of water samples obtain from the disinfested pipe line and disposal of water from the pipe line after completion of the work. The rates including of cost of requisite water to be arranged by the contractor) (The rate of water @Rs. 10/m3 may be recovered, if the contractor used water from deptt. source).
-
-
-
b) 75 mm dia
6
-
4.14
c) 90 mm dia
12
-
10.56
d) 110 mm dia
5
1
5.4
e) 125 mm Dia
4
1
4.96
f) 140 mm dia
4
1
5.76
g) 160 mm dia
3
1
5.19
h) 200 mm dia
3
2
7.26
For Existing FHTC with ferrule connection, Refixing of existing ferrule with fittings in the proposed distribution pipeline and supply, fitting & fixing of all other accessories like saddle piece of required size to fit the proposed pipeline, specials, nut & bolts, rubber sheet, washers etc, including cutting trenches in all sorts of soll and filling up trenches as per direction of the Engineer-in charge.
75
476
35700
Dismantling all type of plain cement concrete works, stacking serviceable materials of site and removing rubbish as directed within a lead of 75mtr. for laying all dia pipe line in ground floor, upto 150mm thick
1
939
939
Providing and fixing 3 layer OO-R (Poly Propylene Random Copopolymer) pipes conforming to IS : 15801 UV stabilized & anti- microbial fusion welded , having thermal stability for hot & cold water supply, including all PP-R plain & brass threaded polypropylene random fittigs , including trenching, refilling & testing of joints complete as per direction of E-I-C. (A) External work( CLASS SD R.4/PN-16) 20 MM DIA (OD)
75
117
8775
Clearing compound premises of shrubs, plants, jungles etc. by cutting & removing as directed (specific permission of engineer incharge prior to execution will necessary). (Payment to be made on area cleared).
550
11
6050
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.
i) Pakur Variety
1
5357
5357.65
Labour for dismantling G.I. pipe with fittings.
(i) 15 mm
75
6
450
Refixing G.I. pipe with fittings after cleaning where necessary.
(i) 15 mm
75
6
450
Dismantling and refixing bib cock or stop cock.
(i) 15 mm
35
12
420
Rewashering stop cock/ bib cock/ push cock/ pillar cock including gland
35
13
455
Supplying, fitting and fixing in position G.I. pipes of TATA make for underground works with all necessary accessories, specials viz.socket, bend, tee, union, cross, elbow, nipple, short piece etc.including cost of all materials,jointing materials ,cutting pipes,making threads,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed with two coats of painting on G.I. pipes and specials with bituminous paint complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.Payment for painting will be made seperately)
(i) 15 mm dia. medium quality
16
214
3424
Providing and fixing service saddle suitable for portable uses including supply of all materials and labours etc.
-
-
-
63 mm X 20mm/25 mm
4
101
407.32
75 mm X 20mm/25 mm
8
113
905.12
90 mm X 20mm/25 mm
12
113
1357.68
GST @18% on all the above items.
1
86765
86765.5
Labour Welfare Cess @1% on all the above items.
1
5687
5687.96
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%