Public Health Engineering Department Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Public Health Engineering Department - PHED Tender

Works
Electrical Generators And Transformers
Machinery and Tools
Electrical and Electronics
Electrical Works
Eprocure
Opening Date16 Jul 2024
Closing Date16 Aug 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Wbphed/ae/bmsd/niet- 4 Of 2024-2025/3

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Gland packing

4

-

-

... More
Shaft for pump (S.S.) suitable for DSM 65/32A Kirloskar pump

2

-

-

... More
Impeller (CI) for above pump as per sample

1

-

-

... More
Gasket

2

-

-

... More
O-Ring

2

-

-

... More
Impeller lock nut

2

-

-

... More
Bearing in existing size(pump-model no-6306, SKF)

4

-

-

... More
Assembling above 15 HP centrifugal pump set part by part with the above materials including supplying necessary materials ie grease, nut bolt etc as per direction of EIC

2

-

-

... More
Reinstallation the complete centrifugal pump motor set carefully and fitting fixing the above same on the base frame with proper alignment reconnection of power line , pipe line, earthing connection, valve etc jointing coupling and necessary repairing including labour charge as per direction of EIC.

2

-

-

... More
CIDF non-rising Sluice Valve (P.N-1.0) generally conforming to IS 14846 and as per technical Specification given in NIT i) DN – 80mm (for Individual delivery line)

4

-

-

... More
Supplying and fixing Sheet steel Main Switches side handle operated on angle iron frame on wall. A. 100A, 50Hz, 415V.

1

-

-

... More
Fault finding and rectification of 15hp dol starter with all switch gear items and replace damage items, wire eic. by engaging skilled technician all complete as per Technical specification and upto entire satisfaction of EIC.

1

-

-

... More
Supply and delivery of 3 pole contactor 415v, 50/60Hz (CAT no-cs94100 dooo)

1

-

-

... More
Supply and delivery of Thermal over load relay Range 24-40A, 415V (CAT NO- SS94145 OOFO).

1

-

-

... More
S&D of Star Delta timer (1 to 30)Sec. (CAT NO- ST80328OOOO)

1

-

-

... More
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. to light/fan/call bell point with Modular type switch (Brand approved by EIC) fixed on Modular GI / PVC switch board with top cover plate on wall incl. mending good damages to original finish. [PVC casingcapping and Switch board both on surface] a. Average run 8 mtr

5

-

-

... More
supply delivery and fitting fixing of 9W LED lamp 3 star as per direction of EIC.

3

-

-

... More
supply delivery and fitting fixing of LED battan 20W tube light on wall as per direction of EIC.

2

-

-

... More
Add: 18% GST

1

-

-

... More
Add: 1% Cess

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.