Public Health Engineering Department Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Public Health Engineering Department - PHED Tender
Civil And Construction
Eprocure
Opening Date12 Jun 2024
Closing Date3 Jul 2024
Tender Amount₹ 91,20,489
Costs
EMD
₹ 1,82,410Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PHED_692512_11Bid Award Id
ViewTender No
WBPHED/EE/NIeT-03/AD/2024-2025Tender Authority
Public Health Engineering Department ViewPurchaser Address
-Website
http://https://www.wbphed.gov.in/en/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Making plain cement concrete (1:2:4) block of 100 mm dia. and 900mm long (0.6m below G.L. and 0.3m above G.L.) for supporting and fixing 15 mm dia. G.I. Pipe for FHTC or as per direction of Engineer in Charge.
1206
183529
152.18
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety
80
492922
6161.53
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth
5
27065
5413
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
480
173280
361
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
100
73600
736
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement (ii) 25 mm. thick.
120
32760
273
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc.
80
2720
34
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]
-
-
-
(i) With 1:6 cement mortar
-
-
-
(b) 20 mm thick plaster
160
28000
175
(c) 15 mm thick plaster
240
36240
151
(ii) With 1:4 cement mortar (b) 10 mm thick plaster
280
37240
133
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (d) Sal : Local
1
77671
77671
Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings.
In ground floor. (iii) 35mm thick shutters with 19mm thick panel of size 30 to 45 cm. (b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak.
4.8
14150
2948
Shutters of 2/3rd panel and 1/3rd glazed of doors and windows as per design (each panel consisting of a single plank without joint and with ordinary glass of 7.4kg. Per sq.m./3mm thick) fitted with putty bed and teak wood beads and nails including fitting and fixing shutters in position but excluding the cost of glass, putty, teak bead, nails, hinges etc. and other fittings, in ground floor. (iv) 25mm thick shutters with 12mm thick panel. (b) Sishu, Gamar, Champ, Badam, Bhola, Mogra, Hallak.
7
17913
2559
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.
4
39552
9888
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (a) One Coat (i) Water based inerior grade Acrylic Primer
800
24640
3080
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface.
Two Coats
800
56000
70
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor (a) One Coat
3000
94200
3140
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground Floor (Two Coat) a) Normal Acrylic Emulsion
3000
201000
67
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
120
3480
29
(b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
120
4560
38
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :
-
-
-
(a) On timber or plastered surface : With other than hi-gloss of approved quality- (iv) Two coats (with any shade except white)
120
9000
75
(b) On steel or other metal surface : With other than hi-gloss of approved quality- (iv) Two coats (with any shade except white)
120
8640
72
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) (b) 40mm X 6mm, 200mm Length
20
500
25
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.
-
-
-
(iv) 75mm. X 47mm. X 1.70mm.
20
620
31
(vii) 100mm. X 58mm. X 1.90mm.
12
564
47
(A) Iron door ring of approved quality fitted and fixed with nut and washer complete. (i) 50mm dia.
12
204
17
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:
-
-
-
(iv) 150mm long x 10mm dia. bolt.
6
378
63
(vii) 225mm long x 10mm dia. bolt.
4
336
84
i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. (b) 250mm long.
12
1908
159
Iron catch hook of approved quality fitted and fixed to shutter and chowkat. (b) 6mm dia x 225mm long.
10
640
64
Supplying, fitting and fixing hinge cleat in position excluding the cost hinge and other fiffitngs. b) with 75mm iron Butt-hinge ii) Sal : Malayasian
10
370
37
Renewing 125mm long wooden buffer block ii) With Sal : Malayasian
10
550
55
(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
100
93621
93621
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety.
60
398148
6635.8
Supplying, laying, fiting, fixing and jointing of UPVC pipes conforming to IS:4985-2000 with latest revision and amendments, if any, with necessary UPVC/CI specials, CIDF sluice valves, as per relevant I.S. specification including labour charges for earth work in excavation in any kind of soil including mixed soil with boulder ,road sub-grade and its flanks but excluding moorum and laterite or sand stonehard arock including cutting of brick payment without damaging the existing telephone/electrical cable line etc.(in case of damage of any type of cable line during excavation, necessary damaged charges as applicable by the respaective authority will be borne by the agency in his own cost. Loading, unloading, carrying of pipes, specials, valves from the local store to work site and lowering laying of pipes specials valves carefully in trenches maintaining proper levels and alignment ,jointing the pipe and specials including supplying of good quality/approved brand solvent cement (as per IS:14182-1994 including cost of all fabricated PVC fitting i.e. tees,bend, reducers, adopter etc.as per IS:101-1988 and making flange joints including supplying required quantity of nuts, bolts and rubber insertion (CIDF sluice valves will be supplied by the department free of cost) as required at site by adopting suitable method so as to facilate the maintenance of pipe line locally as per conventional method including back filling the trenches with good earth obtained from excavation of trenches including consolidation with watering in layer not exceeding 150mm thk. with maintaining an average depth of cushion of 1.10mtr. from the top of pipe line including making interconnection with distribution pipes etc. all complete as per drawing direction and satisfaction of the E.I.C.
-
-
-
N.B. i) Manufacturer’s test certificate for UPVC pipe & specials to be produced before laying of pipe line. ii) 3rd party inspection of UPVC pipe & specials to be done by CEPET or (India) SGS/NTH Kolkata or as per direction of EIC as per approved vender list. iii)No part payment at any stage on account of supply of materials shall be entertained. iv) Payment will be made on actual consumption of materials. v) UPVC pipes for the works to be supplied as per approved vendor list and as per direction & satisfaction of EIC. No pipes will be allowed beyond recommendated vendor list. vi) Submission of drawing of pipe line with statement of materials consumed between node to node points against each R.A. & final bill.if so. vii) Any deviation from required clear cover of 1.10mtr.due to site adverse condition, prior permission is to be obtained from EIC and payment for such work will be made on prorate basis over the rate of entire item. viii)All pipe connection shall be completed in all respect and as per directionof EIC. Decision of EIC in this respect is final & binding. In case of any deviation/or any left out pipe connections an amount of Rs.10,000.00 for each pipe connection will be realized/recovered from the bill. (A) Pressure Rating : Class - III (ii) Laying of pipe line including cost of pipe & fittings/specials but excluding cost of valves.
-
-
-
a) 90mm dia.
300
102600
342
b) 63 mm dia.
600
121200
202
Filling the pipe line with water, testing hydraulically as per I.S 3114-1965 (Article-6) in section of a length not exceeding 500mtr. for head of pressure as per specification including supplying installing and fixing all equipments such as diesel pump set, blank flange, pressure gauge, valve, pressure pump and all other tools and plants including drilling topping and plugging of necessary holes to pipes, blocking ends providing temporary thrust block and subsequent blocking of holes and other jointing materials and dismantling and removal of the same including disposal of water etc. all complete as per specification and direction of EIC. The rate is inclusive of cost of requisite water to be arranged by the contractor (Recovery rate of water @ Rs.10.00/m3, if contractor used water from deptt. source). B) For UPVC/HDPE Pipe
-
-
-
a) 90mm dia.
300
1080
3.6
b) 63 mm dia.
600
1878
3.13
Cleaning thoroughly the inner surface of pipe line including specials and valves by flushing with water and subsequently disinfection of the same pipe line by flushing again with water containing bleaching powder resulting in residual chlorine not less than 15mg/ltrs. after 24hrs. of such filling including laboratory testing of water samples obtain from the disinfested pipe line and disposal of water from the pipe line after completion of the work. The rates including of cost of requisite water to be arranged by the contractor) (The rate of water @Rs. 10/m3 may be recovered, if the contractor used water from deptt. source). B) For UPVC/HDPE Pipe
-
-
-
a) 90mm dia.
300
264
0.88
b) 63 mm dia.
600
372
0.62
Submission of complete detailed drawing of distribution system, rising main etc. after execution of work showing position of different types of valves, fittings/specials sluice valve chamber with location, node to node wise in the sanctioned drawing as completion drawing of the water supply scheme as per direction and satisfaction of EIC. The list of dia wise fitting/specials, different pipes ;of valve used in the rising main should be shown in the completion drawing (not separate) with verified by SAE & AE in-charge of the scheme. The above drawing will be submitted in 5 copies.
900
342
0.38
Labour for digging concrete Y shape post made by Cement Concrete at different places in the PWSS (Ordinary Mazdoor)
20
5390
269.5
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.
20
6700
335
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel I. SAIL/ TATA/RINL
1
96997
96997.1
Providing 10 mm NB Gunmetal ferrule conforming to IS 2692 : 1989 on the existing CI/DI/uPVC/HDPE/GI/AC distribution pipe line with supply, fitting & fixing of all other accessories likes saddle piece of required size to fit the existing distribution pipe line, specials, nut & bolts, rubber sheet, washers etc, including cutting trences in all sorts of soil and filling up trenches as per direction of the Engineer in charge.
1206
1111932
922
Supply of G. I. pipes of TATA make (Medium quality) including necessary sockets a) 15 mm dia.
1420
191700
135
(A) Labour for fitting and fixing G.I. pipes above ground (exposed) in structures with holder bat clamps including cost of jointing materials, holder bat clamps etc.,as necessary, including cutting pipe, making threads etc. complete in all respect with two coats of painting with approved paint any height. (Payment will be made on the centre line measurement of the total pipeline including specials. Payment of painting will be paid seperately) (i) 15 mm dia.
1420
65320
46
Supplying, fitting and fixing bib cock or stop cock.
(g) Supplying, fitting and fixing alloy iron with brass spindle bib cock/stop cock of approved brand and make, spray painted and tested to 21 kg per sq. cm.
(i) 15 mm
800
135200
169
Add riverine @ 30% on all item except item no.3,30,33,34,35,36&37 on Rs.5661172.90
1
1698351
1698351.87
Add GST @ 18% on all item . Rs.7652700.85
1
1377486
1377486.15
Add Welfare Cess @ 1 % i.e. on Rs.9030187
1
90301
90301.87
Evaluation Notes How It Works ?