Public Health Engineering Department Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Public Health Engineering Department - PHED Tender
Civil And Construction
Eprocure
Opening Date19 Sep 2024
Closing Date21 Oct 2024
Tender Amount₹ 10,60,365
Costs
EMD
₹ 21,207Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PHED_752909_4Bid Award Id
ViewTender No
WB/PHED/AE/HSD/NIET-18/HSD OF 2024-25Tender Authority
Public Health Engineering Department ViewPurchaser Address
-Website
http://https://wbphed.gov.in/en/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Brick Work with 1st class brick in cement mortar (1:6)
10.43
56457
5413
b) In Super Structure ground floor (6:1)
13.6
76649
5636
125 mm. th. Brick work with 1st class bricks in cement morter (4:1) in ground floor.
6.49
4776
736
40 mm. thick damp proof course with cement concrete (1:1.5:3) (with graded stone chips 20 mm nominal size) with water proofing compound of approved brand @ 0.2% weight of cement including cost of materials over two coats of non toxic acrylic polymer modified cementitious waterproofing slurry coat complete [cost of water proofing compound and non toxic paint to be paid seperately) for underground water retaining structures.[water proofing as per item no 60 and non toxic paint as per item NO 59 (b) of Section'C' ]
4.78
1419
297
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by through saturation with water ramming complete including the cost of supply of sand. (Payment to be made on the basis of measurment to finished quality work)
8.75
8191
936.21
Ordinery cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement any, in ground floor as per relevant IS codes. (a) Pakur Variety
4.13
25948
6282.95
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.(a) Pakur Variety
5.59
32427
5800.9
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-ln-Charge.
35.22
11798
335
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge-black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation, basement and upto roof of ground floor/upto 4 m(i) Tor steel/Mild Steel II) JSW/JSPL/SHYAM/SRMB/BMASL/ELECTROSTEEL/SSL
0.35
29201
83433.15
Plaster (to wall, floor, ceiling etc.) with sand and cement morter including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scafolding/staging where necessary (ground floor). [Excluding cost of chipping over concrete surface] (i) With 6:1 cement morter. (a) 20 mm. thick plaster (Inside)In ground floor
67.25
11768
175
(b) 15 mm. thick plaster (Outside)
90.7
13695
151
(iii) With 4:1 cement morter. (a) 10 mm. thick plaster
28.5
3790
133
Neat cement punning about 1.5 mm. thick in wall, dado, window, sills floor, drains etc.
18.45
627
34
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rouhening of concrete surface and application of cement slurry before flooring works using cement @1.75Kg/sq.m. all complete including all materials and labour.
In Ground Floor 3mm. thick topping 3mm.thick topping (high polishing grinding on this item is not permitted with ordinary cement).using grey cement(ii) 25 mm. thick
31.94
8719
273
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete. Iron Butt Hinges and M.S clamps. {The quantum should be correted upto three decimals).(e) Sal : local
0.02
1830
83218
Panel shutters of door and window, as per design (each pane consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. In ground floor. (In case of non-supply of single plank, penal rate of reduction o 20% will be made)iii) 35 mm thick shutters with 19 mm thick panel of size 30 to 45 Cm.(b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak.
1.85
5453
2948
PSupplying, fitting and fixing M.S. clamps for door and window fram made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete (1:2:4) as per direction. (Cost of concrete will be paid separately)(a) 40 mm. X 6 mm., 200 mm. length
22
550
25
Iron butt hinges of approved quality fitted and fixed with steel scrws, with ISI mark. (vii) 100 mm. X 58 mm. X 1.90 mm.
4
188
47
Iron socket bolt of approved quality fitted and fixed complete.(d) 225mm long x 10mm dia bolt.
2
154
77
Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16 mm. dia rod with centre bolt and round fitting.(b) 250 mm. long
1
159
159
Iron door ring of approved quality fitted and fixed with nut and washer complete.(ii) 75 mm. dia.
2
56
28
Number plate of building (plate size up to 225 mm x 225 mm) made of sand cement plaster (1 : 2) on face of wall or plinth with 50 mm size letters P.W.D and the number of the structure formed thereon (in sunk type) including painting the letters and the number complete as per direction.
45
5355
119
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or concrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor)(a) One Coati) Water based interior grade Acrylic Primer
74.62
2298
30.8
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer): (Two coats)(I) Standard Quality
74.62
4626
62
Applying Exterior grade Acrlic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface thoroughly, complete as per direction manufacturer's specification and as per direction of E.I.C. In ground floor (b) One Coat[This item to be done under specific instruction of the Superintending Engineer]N.B.: extra for each additional floor in external walls refer item 20.
100.13
3144
31.4
AProtective and decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.In ground floor (Two Coat) a) Normal Acrylic Emulsion
100.13
6708
67
(a)Priming one coat on timber of plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
5.46
207
38
(b) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
7.2
208
29
(A) Painting with best quality synthetic enamel paint of approved make and brand incl. smoothening surface by sand papering etc. incl. using of approved putty etc. on the surface if necessary. (a) On timber or plastered surface: with super gloss (hi-gloss) (iv) Two coats (with any shade except white).
5.46
442
81
with super gloss (hi-gloss)(iv) Two coats (with any shade except white).
7.2
568
79
Supplying fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non- friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc. including hoisting in position, straithening if required, fixing lugs in cement concrete (1:2:4) with stone chips 20mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. (Add extra @ 1.2% for each additional floors upto 4th floor and @1.5% for each additional floor above 4th floor.)b) Openable steel windows as per IS sizess with side hung shutters and horizontal glazing bars with/without fixed type ventilaors. [ The extra rate admissible for the openable portion only]
3.7
8136
2199
iv) Two point nose Alluminium handle including fitting & fixing
7
413
59
vii) Alluminium Peg stay 300m long including fitting & fixing
7
413
59
viii) M.S. Integrated Grill as per approved design integrated with steel window or ventilator, joints continuously welded with M.S flats and bars.
57.6
5414
94
Supply best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall and upto 6 m hight for external wall). ii) 4mm thick
3.34
1790
536
Supplying fitting and fixing in position approved P.V.C. door frame (Matt finish) made of extruded P.V.C. multichamber hollow section having dimensions 60mm X 50mm X 2mm (+- 0.2mm), horizontal section will be joined with vertical section by galvanised steel screws after inserting two number steel brackets as reinforcement 40mm X 20mm X 1.20mm will be inserted on one full vertical side of the frame (hinge side) as reinforcement the frame will then be fixed in the opening with the help of P.V.C. expandable fastner wooden gutties and galvanised steel screws including cost of tools and applications, carriage of all materials taxes and all other incidental charges complete.
4.95
1381
279
PVC Door Shutter -37 mm thick Supplying, Fitting & Fixing 30 mm thick Factory made solid Panel PVC Door
Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost
of steel primers of approved make and manufacture, M.S. frame covered with 5mm th. heat moulded PVC “C” channel of size 30 mm th, 70 mm width out of
which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle oneither sides forming styles; and 5 mm th. 95 mm wide PVC sheet out of which 75
mm shall be flat and 20 mm tapered in 45 degree on the inner side to form top &bottom rail and 115 mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails
shall be provided either side of the panel with 10 mm (5 mmx2) th.,20 mm widecross PVC sheet as gap insert for top rail and bottom rail. Paneling of 5 mm th.both side PVC sheet to be fitted in the M.S. frame welded/sealed to the styles
&rails with 7 mm (5 mm+2 mm) th.x15 mm wide PVC sheet beading on inner sideand joined together with solvent cement adhesive. An additional 5 mm th. PVC
strip of 20 mm which is to be stuck on the interior side of the “C” channel usingPVC solvent adhesive etc. complete excluding all necessary hardwares as perdirection of Engineer-in-Charge.In ground floor.
1.37
2661
1943
Supplying, fitting and fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of Key stones (10 mm) fixed with araldite at the back of each tiles & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles i/c roughening of concrete surface, if necessary or by synthetic adhesive & frout materials etc.(A) Floor
1.91
1442
755
With sand cement morter (1:4) 20 mm. th. & 2 mm. th. Cement sturry at back side of tiles using cement @ 2.91 Kg/sq.m. and joint filling using white cement slurry @ 0.20 Kg/sq.m.(b) Area of each tiles above 0.09 sq m. (i) coloured decorative(B) WallWith sand cement morter (1:3) 15 mm. th. & 2 mm. th. Cement slurry at back side of tiles using cement @ 2.91 Kg/sq.m. and joint filling using white cement slurry @ 0.20 Kg/sq.m.(b) Area of each tiles above 0.09 sq m. (i) coloured decorative
10.03
7592
757
Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) For Exposed WorkPVC Pipes 40 mm (For overflow) dia
3
876
292
25 mm dia
10
1770
177
20 mm dia
12
1548
129
15 mm dia
6
606
101
Supplying, fittings & fixing UPVC (pipe B) Type & fittings conforming to IS - 13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc. if necessary and mending good damages including joining with jointing materials (spun yarn, valamoid/ bitumen/ m-seal etc.) complete. i) Double socket 3 mtr. length. 110 mm.
6
1890
315
ii) Door Bend (TS) 110 mm
2
294
147
ii) Door Tee (TS) 110 mm
1
195
195
iv) Vent cowl 110 mm dia
1
33
33
Supplying fitting and fixing Peets valve fullway gunmetal standard pattern best quality of approved brand bearing ISI making with fittings (tested to 21kg per sq.cm.) viii) 20mm
1
657
657
Supplying fitting and fixing bib cock or stop cock.c) ii) Chromium plated bib cock with wall flange (equivalent to code no. 5047 & model-florentine of jaquer or similar brand).
2
1722
861
Supplying PVC water storage tank of approved quality with closed top with lid(black)-multilayer. d) 500 ltr. Capasity
1
2584
2584
Labour for hoisting plastic water storage tank.(i) Upto 1500 ltr. Capasity.(a) Upto 1st story from G.L.
1
96
96
Labour for lowering plastic water storage tank and stacking in places as directed. (i) Upto 1500 ltr. Capasity.(a) Upto 1st floor from G.L.
1
58
58
Supplying, fitting & fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm x 75 mm x 75 mm wooden blocks complete.(i) 635 mm x 395 mm x 420 mm
1
2869
2869
Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chainaware of approved make in position complete excluding 'P' or 'S' trap.i) 580 x 440 mm
1
1613
1613
Supplying fitting fixing cust iron 'P' or 'S' trap conforming to IS 3989/1970 and 1729/1964 including lead caulked joints and painting two coats to the exposed surfaced. (Painting to be paid separetly)(A) 'P' Trap
(iii) 100 mm.
1
948
948
Supplying, fitting & fixing white vitreous china best quality approved make wash basin with CI brackets on 75 mm X 75 mm wooden blocks, CP waste fitting of 32 mm. dia., one approved quality brass CP pillar cock of 15 mm. dia., CP chain with rubber plug of 30 mm. dia., approved quality PVC waste pipe with CP nut 32 mm. dia., 900 mm. long approved quality PVC connection pipe with heavy brash CP nut including mending good all damages and painting the brackets with two coats of approved paints.(ii) 550 mm. X 400 mm size
1
2208
2208
Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement morter (1:4) including two 560 mm. dia. R.C.C. manhole cover (heavy type) of approved make supplied, fitted & fixed in the 100 mm. thick R.C.C. (1:1.5:3) top slab with necessary fittings 20 mm. thick cement plaster (4:1) with neat cement finish to the internal surface & 15 mm. thick cement plaster (4:1) to out side wall up to 200 mm. below G.L. floor finished with 25 mm. thick gray artificial stone over 100 mm. thick R.C.C. (1:1.5:3) bottom slab including supplying fitting & fixing all necessary specials, fittings, S.W. tees, C.I. footrest etc. including excavating earth in all sorts of soil, shoring, bailing out & pumping out water as necessary, ramming, dressing the ded and reffing the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chember & including constructing attached inspection pit as per approved drawing & connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials.(i) For 10 users A) With Pakur variety (JSW/SSPL/SHYAM/SRMB) other than SAIL/TATA/RINL
1
36187
36187
Construction of circular soak well 2.5 m. deep in all types of sandy soils with dry brick work up to 1.6 m. from the bottom having 150 mm. intermidiate cement brick work (1:4) band allround & cement brick work (1:4) up to 0.90 m. from top with 20 mm. thick cement plastering (1:4) to insite face up to the depth of cement brick work, 15 mm thick cement plaster (1:4) on outer face from the top of the well up to G.L. & 6 mm. thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 m. of insite the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm. thick with cement concret (1:1.5:3) with stone chips with necessary rainforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type) of approved make supplied, fitted & fixed in the cover slab with necessary fittings, making necessary arrangements for pipe connections, excavation of well including shoring, dewatering & removing the excess earth from the premises as per direction complete in all respect with all cost of labour & materials.With 250 mm. thick dry brick work & 250 mm. thick cement brick work (6:1) & 1 m. insite dia. Paku variety. other than SAIL/TATA/RINL
1
16621
16621
Iron door handle of approved quality fitted and fixed complete:150mm x 5.5mm.
2
100
50
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
19.44
466
24
a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department]
21.06
1853
88
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. a) UPVC pipes 110 mm dia
6
1506
251
Earth work in filling in compound tank low land, ditches etc. with good earth in layer not exceeding 150mm. including breaking clods & consolidating the same by ramming & dressing complete.( Payment will be made on profile measurement before and after the work).With carried earth arranged by the contractor within a radius exceeding 3 km. but not exceeding 5 km. including the cost of carried earth.
1068.48
448312
419.58
Add GST@18% Rs.
1
160149
160149.16
Add Cess@1% Rs.
1
10498
10498.67
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements