Public Health Engineering Department Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Public Health Engineering Department - PHED Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date27 Jul 2024
Closing Date17 Aug 2024
Tender Amount₹ 15,44,520 
Notes
Download

Costs

Summary

Wbphed/ee/jd/e-nit- 07/2024-25 (sl.no.12)

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

41.9

13575

324

... More
(II) Cement concrete with 30 mm down graded shingles excluding shuttering. N.B. Variety a) 1:3:6 proportion

4.35

14185

3261.06

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.

3.76

14362

3819.92

... More
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.

12.3

55388

4503.1

... More
Reinforcement for reinforced concrete work in all sorts of structure including distribution bars, stirrups, binders etc. initial straightening and removal of loose rust (if necessary) cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16G black annealed wire at every intersction, complete as per drawing and direction. (i) Ground floor upto 4 m from G.L.(i) Tor steel/Mild Steel II. JSW/JSPL/SHYAM/ SRMB/BMASL/ ELECROSTEEL/SSL

1.25

108732

86986.14

... More
Hire and labour charge for shuttering with centering and necessary staging upto 4m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slab, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto the roof of ground floor) (f) 25 mm to 30 mm shuttering without staging in foundation.

28.45

5832

205

... More
(a) 25mm to 30 mm thick wooden shuttering as per decision & direction of Eng-in - Charge. G.Floor above P.L.

127.06

41675

328

... More
Brick work with 1st class bricks in cement mortar (1:4) (b) In superstructure, ground floor

4.23

22523

5324.8

... More
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.

28.76

19161

666.27

... More
(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)

6.47

3371

521.07

... More
Supplying fitting approved type ventilator in position after cutting holes in walls setting in cement mortar mending damages to wall and plaster and two coats of paint of approved brand of any shade. Payment of mending good damages of wall & plaster and painting to be made separately. (b) R.C.C ventilator of 20 mm. thick (i) Upto 0.10 sq.m. area

5

540

108

... More
Plaster (to wall, floor, ceiling etc) with sand - cement-morter including rounding off and chamfering corners as directed and racking out joints including throating, noising and drip course, scaffolding / staging where necessary ( Ground floor) (excluding cost of chipping over concrete surface ) i)With ( 1:6 ) Plaster c) 15mm thick

76.72

10622

138.46

... More
i)With ( 1:6 ) Plaster c) 20 mm thick, In ground floor

61.9

9756

157.62

... More
ii) With (1:4) Cement morter c) 10 mm thick plaster

77.65

9586

123.46

... More
Neat cement plunning about 1.5mm thick in wall dado, window sills, floors, drains etc. using cement @ .152 cu m/100 sq m

22.59

738

32.71

... More
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement (ii) 25 mm. thick

17.44

4582

262.76

... More
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (d) Sal : Local.

0.14

10138

71907

... More
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) (a) 40mm X 6mm, 250mm Length

20

580

29

... More
Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. In ground floor. (In case of non-supply of single plank, penal rate of reduction of 20% will be made) (iii) 35mm thick shutters with 19mm thick panel of size 30 to 45 cm. (b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak.

3.99

11122

2789

... More
Supplying, Fitting & Fixing 30 mm thick Factory made moulded Door shutter, wood free consisting of frame made out of 25 mm, M.S. tube, M.S. frame shall have a coat of steel primer. The inner panel shall consist of 25 mm thick High Density EPS. With 2 mm thick termite proof, water proof and fire resistant moulded PVC sheet with raised panel design in different plain and /or prelam colours after routing the moulded design on one side & 2 mm plain and/ or prelam PVC sheet on other side of the EPS. The edge of Panel to be sealed with lipping of 10 mm wide P.V.C. sheet batten made by sticking 2 Nos P.V.C. rigid foam sheet of 5 mm thickness using P.V.C. solvent cement and style sides 25 mm [5x5 mm] th. and 30 mm with PVC sheet fitted along M.S. tube for lock provision and for lock height 5 mm thick PVC sheet [150 mmx100 mm] fixed with upper and lower face of inner side of EPS Panel etc. complete excluding hardwares as necessary as per direction of Engineer-in-Charge and Manufacturer‟s Specification. In ground floor. (a) Moulded door using 2 mm moulded PVC sheet or 2 mm etched moulded PVC sheet on one side & 2 mm PVC sheet on other side.

1.33

3539

2655

... More
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. (vii) 100mm. X 58mm. X 1.90mm.

6

282

47

... More
(iv) 75mm. X 47mm. X 1.70mm.

11

341

31

... More
i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. (c) 300mm long.

1

166

166

... More
Iron socket bolt of approved quality fitted and fixed complete. (b) 100mm long x 10mm dia bolt.

2

80

40

... More
(a) 75mm long x 10mm dia bolt.

6

204

34

... More
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: (a) With continuous plate base (Hexagonal/ Round rod) (ii) 100 mm grip x 10 mm dia rod.

8

552

69

... More
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (ii) Grill weighing above 16 Kg./sq.mtr and above

0.38

3685

9827

... More
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor: (b) Two Coats.

114.17

5149

45.1

... More
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) c) Normal Acrylic Emulsion.

114.17

7649

67

... More
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.

3.47

100

29

... More
(b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.

13.14

499

38

... More
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white

3.47

274

79

... More
(a) On timber or plastered surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)

13.14

1064

81

... More
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and\ brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section,\ consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural\ members only in finished work as per IS specified weight. \Payment for gusset, bracket, cleat, rivets, bolts and nuts may be make by adding the actual weight of such items with the weight of finished structural members or 7% of weight for finished structural members weighing not less than 22.5 Kg. / m. or 15 % of weight for finished structal members weighing less than 22.5 Kg. / m. may be increased allow for bracket, cleat, rivet, bolts and nuts etc. and no separate payment being made for these items, as per direction of Engineer In Charge. The rates are considered for a height of erection 8m. / 2nd floor level from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initiial 8m. or part thereof. I) For structural members of specified sections weighing less than 22.5 Kg./m

0.12

8948

74571

... More
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. ii) With Bazree (N.B Varity) (JSW/JSP/SHYAM/SRMB/BMASL/ELECTROSTEEL/SSL).

1

6451

6451

... More
Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,Part- I.Payment will be made separetly on the basis of actual height based on relevant I.S.Code. (i) For 10 users B)WithBazree(N.BVarity)(SW/JSPL/SHYAM/SRMB/BMASL/ELECTROSTEEL/SSL)

1

33410

33410

... More
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. JSW/JSPL/SHYAM/SRMB/BMASL/ELECTROSTEEL/SSL)

1

15556

15556

... More
Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding 'P' or 'S' trap (excluding cost of concrete for fixing). (i) 580 mm X 440 mm

1

1613

1613

... More
Supplying,fitting and fixing cast iron 'P' or 'S' trap conformimg to I.S. 3989/ 2009 and 1729/ 2002 including lead caulked joints and painting two coats to the exposed surface. (Painting to be paid seperately). (A) 'P' Trap (iii) 100 mm

1

948

948

... More
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.

1

1015

1015

... More
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (iii) Single Socketed 1.8 Meter Length (b) 110 mm

5.4

1582

293

... More
Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin- charge. (Payment will be made on centre line measurement of the total pipeline including specials. (A) Above ground (ii) 110 mm dia.

2.4

136

57

... More
(B) Under ground (ii) 110 mm dia.

3

252

84

... More
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (a) 500 litre capacity

1

2584

2584

... More
Labour for hoisting plastic water storage tank. (i) Upto 1500 litre capacity. (a) Upto 1st story from G.L.

1

96

96

... More
Labour for punching hole in plastic water storage tank upto 50 mm dia.

3

57

19

... More
Supplying, fitting and fixing bib cock or stop cock. (f) (ii) Polythene Bib Cock / Stop Cock with plastic inlet (EMCO / ATLAS or equivalent) 15 mm

2

178

89

... More
Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007 (Q) Ball Valve (Dia) 25 mm

2

586

293

... More
15 mm

1

99

99

... More
Supplying, fitting and fixing towel rail with two brackets. (a) C.P. over brass (i) 25 mm dia. and 450 mm long

1

384

384

... More
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. (i) 450 mm X 300 mm size

1

1979

1979

... More
Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia(ii) 450 mm long

1

82

82

... More
Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps.(i) 600 mm long

1

47

47

... More
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) For Exposed Work PVC Pipes (Dia) 15 mm

3

303

101

... More
25 mm

18

3186

177

... More
Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in-Charge prior to execution will be necessary). (Payment to be made on area cleared)

340

3740

11

... More
TUBE WELL

-

-

-

... More
Site Preparation, Temporary Latrine, Placement & levelling of Rig Machine, Mast hoisting and Casing drilling (Upto 6 mtr.) Placement of Casing with all allied works necessary to commence drilling woks and wind up of all machineries after completion of Drilling.

1

64146

64146

... More
Drilling by Reverse Rotary method of drilling using 9 7/8” dia.bit for pilot bore follwed by subsequently reaming using 12 1/4” dia. ,15 " dia. and 17.5" dia. Rock Roller Bits/ Drag Bits in consolidated, semi consolidated and soft formation up to required depth including casing boring and casing lowering as required including cost of fuels and lubricants etc. as required for drilling. Note: 1)Rate only for pilot drilling will be @ 50%. of item rate. 2)Rate for reaming by 12 1/4 " dia. bit will be @ 14% of item rate. 3)Rate for reaming by 15 " dia. bit will be @ 16% of item rate. 4)Rate for reaming by 17.5 " dia. bit will be @ 20% of item rate. a) From 6 Mtr. to 60 Mtr.

54

43011

796.5

... More
b) From 60 Mtr. to 90 Mtr.

30

26298

876.6

... More
c) From 90 Mtr. to 120 Mtr.

30

28917

963.9

... More
d) From 120 Mtr. to 150 Mtr.

9

9541

1060.2

... More
Lowering the tube well assembly (UPVC Casing pipe ,well pipe, strainer along with UPVC accessories) vertically in a position with proper lowering arrangement by applying necessary jointing compound including labour cost for subsequent gravel packing and machine operation cost etc.

1

26571

26571

... More
Cost of Consumables for drilling rigs and machineries.

1

22077

22077

... More
Development (Min. 8 Hr. continuous) of tube well by using suitable air compressor (Min. Capacity: 600CFM & operating Pressure 14 Bar) followed by yield testing with BHT pump (Head :45 to 50mtr.,Discharge :1100 to 1000 LPM and 25 BHP engine) all complete including To & Fro Transportation cost and Cost of fuels, lubricants & Labour etc.

1

56908

56908

... More
Water sample collection and chemical test including Arsenic Test.

1

2425

2425

... More
Transportation cost of drilling equipment and accessories rig machine etc. including cost of fuel,Lubricant & loading unloading the materials from store/stack yard /suppliers godown and unloading /stacking the same at site.

1

59786

59786

... More
Supply and delivery of UPVC pipe (CM) conforming to IS 12818:2010. (CIPET Certified) c) 200 mm dia.

36

80928

2248

... More
d) 150 mm dia.

63

77931

1237

... More
Supply and delivery of UPVC Medium Well Screen (RMS) Pipes with Ribs conforming to IS 12818:2010. (CIPET Certified) b) 150 mm dia.

30

53790

1793

... More
Supply and delivery of UPVC Reducer d) 200mmx 150 mm dia.

1

1213

1213

... More
Supply and delivery of UPVC Cap c) 200 mm dia.

1

1372

1372

... More
Supply and delivery of MS Center Guide

1

950

950

... More
Supply and delivery of M.S. Housing clamp 250 mm dia.

1

3252

3252

... More
Supply and delivery of Washed gravels size ranging from 1.80 mm to 4.74 mm. conforming to IS 4097 : 1967.

25

95250

3810

... More
Supply and delivery of Bentonite Powder conforming to IS 6186 : 1986.

0.25

3490

13963

... More
Electro-logging charge.

1

15715

15715

... More
Rising Line

-

-

-

... More
Carrying CI/DI pipes with specials and valves and lowering placing in position and laying carefully inside the trenches in proper alignment and gradient etc. including earth work in excavation of adequate width as per specification having min. clear cover from top of pipe is 1.10mtr. below existing ground level in any kind of soil including mixed with boulder, road sub-grade and its flank,but excluding moorum and laterite and stone etc.without damaging the exisiting telephone/electric cable etc.(in case of damaged if any type of cable line during excecution , necessary damaged charges as applicable by the respective authority will be borne by the agency in his own cost) preparing the bottom surface for continuous bedding of pipe line and laying pipes, fitting, fixing specials and valves with bailing out water if any including carriage of pipes, specials and valves from local deptt. store within 8KM and back filling the trenches with excavated earth in layers to original condition as per specification and direction of EIC. The surplus materials after execution of work are to be return to the deptt. store. N.B: i) Any deviation from required clear cover of 1.10mtr., due to site adverse condition, prior permission is to be obtained from the EIC in exceptional situation and payment will be made on prorate basis over the rate of entire item ii) No payment will be made without hydraulic test of the pipe line either part or full iii) The pipes, specials and valves , rubber gasket will be supplied deptt. free of cost.

-

-

-

... More
150 mm dia. (K-9)

100

11200

112

... More
Making rubber gasket joint to CI/DI pipes maintaining proper alignment level etc. by mechanical arrangement with or without using mobile cranes where necessary and with help of all other equipments tools and tackles etc. as required providing lubricants of approved quality and direction of EIC. (rubber gasket will be supplied deptt. free of cost)

-

-

-

... More
150 mm dia.

19

722

38

... More
Carriage of different type of departmental pipes from Divisional/Sub-divisional store to the work site by truck including loading, unloading, stacking etc. including cost of fuel, lubricant and also cost of driver, helper etc. and all other taxes and charges as applicable as per direction of EIC

-

-

-

... More
e) Above 30 Km upto 40 Km

1

3213

3213

... More
Filling the pipe line with water, testing hydraulically as per I.S 3114-1965 (Article-6) in section of a length not exceeding 500mtr. for head of pressure as per specification including supplying installing and fixing all equipments such as diesel pump set, blank flange, pressure gauge, valve, pressure pump and all other tools and plants including drilling topping and plugging of necessary holes to pipes, blocking ends providing temporary thrust block and subsequent blocking of holes and other jointing materials and dismantling and removal of the same including disposal of water etc. all complete as per specification and direction of EIC. The rate is inclusive of cost of requisite water to be arranged by the contractor (Recovery rate of water @ Rs.10.00/m3, if contractor used water from deptt. source).

-

-

-

... More
A) For CI/DI pipe

-

-

-

... More
150 mm dia.

100

420

4.2

... More
Cleaning thoroughly the inner surface of pipe line including specials and valves by flushing with water and subsequently disinfection of the same pipe line by flushing again with water containing bleaching powder resulting in residual chlorine not less than 15mg/ltrs. after 24hrs. of such filling including laboratory testing of water samples obtain from the disinfested pipe line and disposal of water from the pipe line after completion of the work. The rates including of cost of requisite water to be arranged by the contractor) (The rate of water @Rs. 10/m3 may be recovered, if the contractor used water from deptt. source).

-

-

-

... More
A) For CI/DI pipe

-

-

-

... More
150 mm dia.

100

154

1.54

... More
Supply and delivery of CIDF sluice valve (Special type) PW-1.00 of different dia make with CI double flanged non rusting spindle sluice valves conforming to IS 14846 -2000 with latest emended having body dome/bonnet and cover of C.I.Gr-F.G 210mtr. spindle of IS-6603 G.R- 12/Gr-13 non-magnetic, nuts seat rings are of Gunonetal as per IS:318 LTB-2 flanges and drilled to IS:1538 Part IV & VI valves are suitable for max. working pressure of 10kg/cm2(seat test) and body tested to 15kg/cm2.N.B: The above item should be procured from the reputed manufactures as per deptt. approved vender list

-

-

-

... More
150 mm dia.

3

27522

9174

... More
Making flange joint to CIDF pipe, specials, valves etc.with supply of necessary nuts and bolts, rubber insertion of 6kg/m2 (3mm gauge) and materials required including dewatering if any tools and plants, labour cost etc. as per specification and direction of EIC (Nut and bolts shall be of TATA/GKW make) for

-

-

-

... More
80 mm dia.

3

717

239

... More
100 mm dia.

4

1596

399

... More
150 mm dia.

8

3448

431

... More
Supply of CI Jeffy coupling as per IS specification.

-

-

-

... More
150 mm dia.

8

13016

1627

... More
Labour charges for Jeffy joint of all diameter.

8

678

84.75

... More
Supply at site/local store CIPE and CISS specials as per relevant IS specification with latest smendments including cost of loading, carring, unloading, stacking peoperly and sales tax & all other charges etc. complete as per direction of EIC (Mode of measurement will be on book weight) & specials.

115

10876

94.58

... More
Supply the following materials for connection of inlet, outlet, overflow, washout of OHR as per deptt. Drawings. (A) CIDF pipe Class-B as per I.S. 7181-1986 with latest revision.

224.8

21468

95.5

... More
Supply the following materials for connection of inlet, outlet, overflow, washout of OHR as per deptt. Drawings. (B) CIDF Duck foot bend as per I.S. 1538 1976 with latest revision. (C) CIDF Bell mouth pes. with puddle collar as per ISI 1538-1976 with latest revision (D) C.I.D.F 90˚ Bend as per I.S.1538 (Part-XXI)-1976 with latest amended.

120

11460

95.5

... More
Labour for horizontal boring under pacca road etc. for laying of GI/CI/DI pipeline thorugh horizontal boring including all labour tools and plants and all incidental charges complete as per direction of EIC.

5

1101

220.34

... More
Construction of different dia Sluice valve /Air valve /Washout chamber in different sizes for village road where light traffic run and for main road where heavy traffic run as deptt.approved drawing with 25cm thick brick work (1:6) over cement concrete (4:2:1) over a single B/F soling over150mm.thick sand filling in foundation including earth work in excavation and disposal of excess earth from work site with RCC (1:1.5:3) cover slab 100mm / 150mm thick slab on top of chamber with 1% reinforcement in RCC cover slab with necessary opening for operation of valve all complete including cost of labour & materials as per Departmental Dwg. [Reinforcement type:- Other manufactuerers not specified]

-

-

-

... More
80 mm to 150 mm dia pipe

3

35505

11835

... More
Chamfering the spigot end of all type/class of DI pipe for proper using of push joint by means of grinder set at site for proper joint etc. all complete as per direction of EIC.

-

-

-

... More
150 mm dia.

8

864

108

... More
Cutting DI pipe (all class & type) to required length with cutting device etc. and grinding the cutting portion with file as per direction and satisfaction of EIC.

-

-

-

... More
150 mm dia. to 200 mm dia pipe

8

1128

141

... More
Bituminous pucca road (approx. 450mm depth) cutting by using gaiti, chisel, hammer etc. and picking uip the withdrawing excavated materials and remove the same within distance of 30mtr. at least all complete for fixing/crossing all dia of pipe line as per direction of EIC

1

1023

1023

... More
Making holes in two sides of wall of culvert/drain or any other structures in any places for laying any dia pipe line within structures intwo sides of wall of culvert /drain /any structure at any places and mending good damages all complete as per direction of EIC.

2

1136

568

... More
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof. (a) upto 150 mm. thick

2

1878

939

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. (b) River bazree

2

7639

3819.92

... More
Submission of complete detailed drawing of distribution system, rising main etc. after execution of work showing position of different types of valves, fittings/specials sluice valve chamber with location, node to node wise in the sanctioned drawing as completion drawing of the water supply scheme as per direction and satisfaction of EIC. The list of dia wise fitting/specials, different pipes ;of valve used in the rising main should be shown in the completion drawing (not separate) with verified by SAE & AE in-charge of the scheme. The above drawing will be submitted in 5 copies.

100

38

0.38

... More
Add GST @ 18%

1

233272

233272.05

... More
Add Labour Welfare Cess @1%

1

15292

15292.28



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.